Abstract: In this paper, we report the experimental results on using complementary Golay coded signals at 7.5 MHz to detect breast microcalcifications of 50 µm size. Simulations using complementary Golay coded signals show perfect consistence with the experimental results, confirming the improved signal to noise ratio for complementary Golay coded signals. For improving the success on detecting the microcalcifications, orthogonal complementary Golay sequences having cross-correlation for minimum interference are used as coded signals and compared to tone burst pulse of equal energy in terms of resolution under weak signal conditions. The measurements are conducted using an experimental ultrasound research scanner, Digital Phased Array System (DiPhAS) having 256 channels, a phased array transducer with 7.5 MHz center frequency and the results obtained through experiments are validated by Field-II simulation software. In addition, to investigate the superiority of coded signals in terms of resolution, multipurpose tissue equivalent phantom containing series of monofilament nylon targets, 240 µm in diameter, and cyst-like objects with attenuation of 0.5 dB/[MHz x cm] is used in the experiments. We obtained ultrasound images of monofilament nylon targets for the evaluation of resolution. Simulation and experimental results show that it is possible to differentiate closely positioned small targets with increased success by using coded excitation in very weak signal conditions.
Abstract: Computer aided diagnosis systems provide vital
opinion to radiologists in the detection of early signs of breast cancer
from mammogram images. Architectural distortions, masses and
microcalcifications are the major abnormalities. In this paper, a
computer aided diagnosis system has been proposed for
distinguishing abnormal mammograms with architectural distortion
from normal mammogram. Four types of texture features GLCM
texture, GLRLM texture, fractal texture and spectral texture features
for the regions of suspicion are extracted. Support vector machine
has been used as classifier in this study. The proposed system yielded
an overall sensitivity of 96.47% and an accuracy of 96% for
mammogram images collected from digital database for screening
mammography database.
Abstract: Mammography has been one of the most reliable
methods for early detection of breast cancer. There are different
lesions which are breast cancer characteristic such as
microcalcifications, masses, architectural distortions and bilateral
asymmetry. One of the major challenges of analysing digital
mammogram is how to extract efficient features from it for accurate
cancer classification. In this paper we proposed a hybrid feature
extraction method to detect and classify all four signs of breast
cancer. The proposed method is based on multiscale surrounding
region dependence method, Gabor filters, multi fractal analysis,
directional and morphological analysis. The extracted features are
input to self adaptive resource allocation network (SRAN) classifier
for classification. The validity of our approach is extensively
demonstrated using the two benchmark data sets Mammographic
Image Analysis Society (MIAS) and Digital Database for Screening
Mammograph (DDSM) and the results have been proved to be
progressive.
Abstract: Clusters of Microcalcifications (MCCs) are most frequent symptoms of Ductal Carcinoma in Situ (DCIS) recognized by mammography. Least-Square Support Vector Machine (LS-SVM) is a variant of the standard SVM. In the paper, LS-SVM is proposed as a classifier for classifying MCCs as benign or malignant based on relevant extracted features from enhanced mammogram. To establish the credibility of LS-SVM classifier for classifying MCCs, a comparative evaluation of the relative performance of LS-SVM classifier for different kernel functions is made. For comparative evaluation, confusion matrix and ROC analysis are used. Experiments are performed on data extracted from mammogram images of DDSM database. A total of 380 suspicious areas are collected, which contain 235 malignant and 145 benign samples, from mammogram images of DDSM database. A set of 50 features is calculated for each suspicious area. After this, an optimal subset of 23 most suitable features is selected from 50 features by Particle Swarm Optimization (PSO). The results of proposed study are quite promising.
Abstract: This paper presents an approach for early breast
cancer diagnostic by employing combination of artificial neural
networks (ANN) and multiwaveletpacket based subband image
decomposition. The microcalcifications correspond to high-frequency
components of the image spectrum, detection of microcalcifications
is achieved by decomposing the mammograms into different
frequency subbands,, reconstructing the mammograms from the
subbands containing only high frequencies. For this approach we
employed different types of multiwaveletpacket. We used the result
as an input of neural network for classification. The proposed
methodology is tested using the Nijmegen and the Mammographic
Image Analysis Society (MIAS) mammographic databases and
images collected from local hospitals. Results are presented as the
receiver operating characteristic (ROC) performance and are
quantified by the area under the ROC curve.
Abstract: Clusters of microcalcifications in mammograms are an
important sign of breast cancer. This paper presents a complete
Computer Aided Detection (CAD) scheme for automatic detection of
clustered microcalcifications in digital mammograms. The proposed
system, MammoScan μCaD, consists of three main steps. Firstly
all potential microcalcifications are detected using a a method for
feature extraction, VarMet, and adaptive thresholding. This will also
give a number of false detections. The goal of the second step,
Classifier level 1, is to remove everything but microcalcifications.
The last step, Classifier level 2, uses learned dictionaries and sparse
representations as a texture classification technique to distinguish
single, benign microcalcifications from clustered microcalcifications,
in addition to remove some remaining false detections. The system
is trained and tested on true digital data from Stavanger University
Hospital, and the results are evaluated by radiologists. The overall
results are promising, with a sensitivity > 90 % and a low false
detection rate (approx 1 unwanted pr. image, or 0.3 false pr. image).
Abstract: An effective method for the early detection of breast
cancer is the mammographic screening. One of the most important
signs of early breast cancer is the presence of microcalcifications. For
the detection of microcalcification in a mammography image, we
propose to conceive a multiagent system based on a dual irregular
pyramid.
An initial segmentation is obtained by an incremental approach;
the result represents level zero of the pyramid. The edge information
obtained by application of the Canny filter is taken into account to
affine the segmentation. The edge-agents and region-agents cooper
level by level of the pyramid by exploiting its various characteristics
to provide the segmentation process convergence.
Abstract: Texture classification is an important image processing
task with a broad application range. Many different techniques for
texture classification have been explored. Using sparse approximation
as a feature extraction method for texture classification is a relatively
new approach, and Skretting et al. recently presented the Frame
Texture Classification Method (FTCM), showing very good results on
classical texture images. As an extension of that work the FTCM is
here tested on a real world application as detection of abnormalities
in mammograms. Some extensions to the original FTCM that are
useful in some applications are implemented; two different smoothing
techniques and a vector augmentation technique. Both detection of
microcalcifications (as a primary detection technique and as a last
stage of a detection scheme), and soft tissue lesions in mammograms
are explored. All the results are interesting, and especially the results
using FTCM on regions of interest as the last stage in a detection
scheme for microcalcifications are promising.
Abstract: A mammography image is composed of low contrast area where the breast tissues and the breast abnormalities such as microcalcification can hardly be differentiated by the medical practitioner. This paper presents the application of active contour models (Snakes) for the segmentation of microcalcification in mammography images. Comparison on the microcalcifiation areas segmented by the Balloon Snake, Gradient Vector Flow (GVF) Snake, and Distance Snake is done against the true value of the microcalcification area. The true area value is the average microcalcification area in the original mammography image traced by the expert radiologists. From fifty images tested, the result obtained shows that the accuracy of the Balloon Snake, GVF Snake, and Distance Snake in segmenting boundaries of microcalcification are 96.01%, 95.74%, and 95.70% accuracy respectively. This implies that the Balloon Snake is a better segmentation method to locate the exact boundary of a microcalcification region.
Abstract: X-ray mammography is the most effective method for
the early detection of breast diseases. However, the typical diagnostic
signs such as microcalcifications and masses are difficult to detect
because mammograms are of low-contrast and noisy. In this paper, a
new algorithm for image denoising and enhancement in Orthogonal
Polynomials Transformation (OPT) is proposed for radiologists to
screen mammograms. In this method, a set of OPT edge coefficients
are scaled to a new set by a scale factor called OPT scale factor. The
new set of coefficients is then inverse transformed resulting in
contrast improved image. Applications of the proposed method to
mammograms with subtle lesions are shown. To validate the
effectiveness of the proposed method, we compare the results to
those obtained by the Histogram Equalization (HE) and the Unsharp
Masking (UM) methods. Our preliminary results strongly suggest
that the proposed method offers considerably improved enhancement
capability over the HE and UM methods.
Abstract: Breast cancer detection techniques have been reported
to aid radiologists in analyzing mammograms. We note that most
techniques are performed on uncompressed digital mammograms.
Mammogram images are huge in size necessitating the use of
compression to reduce storage/transmission requirements. In this
paper, we present an algorithm for the detection of
microcalcifications in the JPEG2000 domain. The algorithm is based
on the statistical properties of the wavelet transform that the
JPEG2000 coder employs. Simulation results were carried out at
different compression ratios. The sensitivity of this algorithm ranges
from 92% with a false positive rate of 4.7 down to 66% with a false
positive rate of 2.1 using lossless compression and lossy compression
at a compression ratio of 100:1, respectively.