Abstract: This paper investigates successful sub-bands of wave atom transform via classification of mammograms, when the coefficients of sub-bands are used as features. A computer-aided diagnosis system is constructed by using wave atom transform, support vector machine and k-nearest neighbor classifiers. Two-class classification is studied in detail using two data sets, separately. The successful sub-bands are determined according to the accuracy rates, coefficient numbers, and sensitivity rates.
Abstract: One of the significant and continual public health problems in the world is breast cancer. Early detection is very important to fight the disease, and mammography has been one of the most common and reliable methods to detect the disease in the early stages. However, it is a difficult task, and computer-aided diagnosis (CAD) systems are needed to assist radiologists in providing both accurate and uniform evaluation for mass in mammograms. In this study, a multiresolution statistical method to classify mammograms as normal and abnormal in digitized mammograms is used to construct a CAD system. The mammogram images are represented by wave atom transform, and this representation is made by certain groups of coefficients, independently. The CAD system is designed by calculating some statistical features using each group of coefficients. The classification is performed by using support vector machine (SVM).
Abstract: Cancer affects people globally with breast cancer being a leading killer. Breast cancer is due to the uncontrollable multiplication of cells resulting in a tumour or neoplasm. Tumours are called ‘benign’ when cancerous cells do not ravage other body tissues and ‘malignant’ if they do so. As mammography is an effective breast cancer detection tool at an early stage which is the most treatable stage it is the primary imaging modality for screening and diagnosis of this cancer type. This paper presents an automatic mammogram classification technique using wavelet and Gabor filter. Correlation feature selection is used to reduce the feature set and selected features are classified using different decision trees.
Abstract: Computer aided diagnosis systems provide vital
opinion to radiologists in the detection of early signs of breast cancer
from mammogram images. Architectural distortions, masses and
microcalcifications are the major abnormalities. In this paper, a
computer aided diagnosis system has been proposed for
distinguishing abnormal mammograms with architectural distortion
from normal mammogram. Four types of texture features GLCM
texture, GLRLM texture, fractal texture and spectral texture features
for the regions of suspicion are extracted. Support vector machine
has been used as classifier in this study. The proposed system yielded
an overall sensitivity of 96.47% and an accuracy of 96% for
mammogram images collected from digital database for screening
mammography database.
Abstract: Mammography is widely used technique for breast cancer
screening. There are various other techniques for breast cancer screening
but mammography is the most reliable and effective technique. The
images obtained through mammography are of low contrast which
causes problem for the radiologists to interpret. Hence, a high quality
image is mandatory for the processing of the image for extracting any
kind of information from it. Many contrast enhancement algorithms have
been developed over the years. In the present work, an efficient
morphology based technique is proposed for contrast enhancement of
masses in mammographic images. The proposed method is based on
Multiscale Morphology and it takes into consideration the scale of the
structuring element. The proposed method is compared with other stateof-
the-art techniques. The experimental results show that the proposed
method is better both qualitatively and quantitatively than the other
standard contrast enhancement techniques.
Abstract: Breast cancer is considered as a substantial health
concern and practicing mammography screening [MS] is important in
minimizing its related morbidity. So it is essential to have a better
understanding of breast cancer screening behaviors of women and
factors that influence utilization of them. The aim of this study is to
identify the factors that are linked to MS behaviors among the
Egyptian women. A cross-sectional descriptive design was carried
out to provide a snapshot of the factors that are linked to MS
behaviors. A convenience sample of 311 women was utilized and all
eligible participants admitted to the Women Imaging Unit who are 40
years of age or above, coming for mammography assessment, not
pregnant or breast feeding and who accepted to participate in the
study were included. A structured questionnaire was developed by
the researchers and contains three parts; Socio-demographic data;
Motivating factors associated with MS; and association between MS
and model of behavior change. The analyzed data indicated that most
of the participated women (66.6%) belonged to the age group of 40-
49.A high proportion of participants (58.1%) of group having
previous MS influenced by their neighbors to practice MS, whereas
32.7 % in group not having previous MS were influenced by family
members which indicated significant differences (P
Abstract: Mammography has been one of the most reliable
methods for early detection of breast cancer. There are different
lesions which are breast cancer characteristic such as
microcalcifications, masses, architectural distortions and bilateral
asymmetry. One of the major challenges of analysing digital
mammogram is how to extract efficient features from it for accurate
cancer classification. In this paper we proposed a hybrid feature
extraction method to detect and classify all four signs of breast
cancer. The proposed method is based on multiscale surrounding
region dependence method, Gabor filters, multi fractal analysis,
directional and morphological analysis. The extracted features are
input to self adaptive resource allocation network (SRAN) classifier
for classification. The validity of our approach is extensively
demonstrated using the two benchmark data sets Mammographic
Image Analysis Society (MIAS) and Digital Database for Screening
Mammograph (DDSM) and the results have been proved to be
progressive.
Abstract: Clusters of Microcalcifications (MCCs) are most frequent symptoms of Ductal Carcinoma in Situ (DCIS) recognized by mammography. Least-Square Support Vector Machine (LS-SVM) is a variant of the standard SVM. In the paper, LS-SVM is proposed as a classifier for classifying MCCs as benign or malignant based on relevant extracted features from enhanced mammogram. To establish the credibility of LS-SVM classifier for classifying MCCs, a comparative evaluation of the relative performance of LS-SVM classifier for different kernel functions is made. For comparative evaluation, confusion matrix and ROC analysis are used. Experiments are performed on data extracted from mammogram images of DDSM database. A total of 380 suspicious areas are collected, which contain 235 malignant and 145 benign samples, from mammogram images of DDSM database. A set of 50 features is calculated for each suspicious area. After this, an optimal subset of 23 most suitable features is selected from 50 features by Particle Swarm Optimization (PSO). The results of proposed study are quite promising.
Abstract: Breast region segmentation is an essential prerequisite in computerized analysis of mammograms. It aims at separating the breast tissue from the background of the mammogram and it includes two independent segmentations. The first segments the background region which usually contains annotations, labels and frames from the whole breast region, while the second removes the pectoral muscle portion (present in Medio Lateral Oblique (MLO) views) from the rest of the breast tissue. In this paper we propose hybridization of Connected Component Labeling (CCL), Fuzzy, and Straight line methods. Our proposed methods worked good for separating pectoral region. After removal pectoral muscle from the mammogram, further processing is confined to the breast region alone. To demonstrate the validity of our segmentation algorithm, it is extensively tested using over 322 mammographic images from the Mammographic Image Analysis Society (MIAS) database. The segmentation results were evaluated using a Mean Absolute Error (MAE), Hausdroff Distance (HD), Probabilistic Rand Index (PRI), Local Consistency Error (LCE) and Tanimoto Coefficient (TC). The hybridization of fuzzy with straight line method is given more than 96% of the curve segmentations to be adequate or better. In addition a comparison with similar approaches from the state of the art has been given, obtaining slightly improved results. Experimental results demonstrate the effectiveness of the proposed approach.
Abstract: The paper aims to specify and build a system, a learning support in radiology-senology (breast radiology) dedicated to help assist junior radiologists-senologists in their radiologysenology- related activity based on experience of expert radiologistssenologists. This system is named SAFRS (i.e. system supporting the training of radiologists-senologists). It is based on the exploitation of radiologic-senologic images (primarily mammograms but also echographic images or MRI) and their related clinical files. The aim of such a system is to help breast cancer screening in education. In order to acquire this expert radiologist-senologist knowledge, we have used the CBR (case-based reasoning) approach. The SAFRS system will promote the evolution of teaching in radiology-senology by offering the “junior radiologist" trainees an advanced pedagogical product. It will permit a strengthening of knowledge together with a very elaborate presentation of results. At last, the know-how will derive from all these factors.
Abstract: This paper presents an approach for early breast
cancer diagnostic by employing combination of artificial neural
networks (ANN) and multiwaveletpacket based subband image
decomposition. The microcalcifications correspond to high-frequency
components of the image spectrum, detection of microcalcifications
is achieved by decomposing the mammograms into different
frequency subbands,, reconstructing the mammograms from the
subbands containing only high frequencies. For this approach we
employed different types of multiwaveletpacket. We used the result
as an input of neural network for classification. The proposed
methodology is tested using the Nijmegen and the Mammographic
Image Analysis Society (MIAS) mammographic databases and
images collected from local hospitals. Results are presented as the
receiver operating characteristic (ROC) performance and are
quantified by the area under the ROC curve.
Abstract: Image compression is one of the most important
applications Digital Image Processing. Advanced medical imaging
requires storage of large quantities of digitized clinical data. Due to
the constrained bandwidth and storage capacity, however, a medical
image must be compressed before transmission and storage. There
are two types of compression methods, lossless and lossy. In Lossless
compression method the original image is retrieved without any
distortion. In lossy compression method, the reconstructed images
contain some distortion. Direct Cosine Transform (DCT) and Fractal
Image Compression (FIC) are types of lossy compression methods.
This work shows that lossy compression methods can be chosen for
medical image compression without significant degradation of the
image quality. In this work DCT and Fractal Compression using
Partitioned Iterated Function Systems (PIFS) are applied on different
modalities of images like CT Scan, Ultrasound, Angiogram, X-ray
and mammogram. Approximately 20 images are considered in each
modality and the average values of compression ratio and Peak
Signal to Noise Ratio (PSNR) are computed and studied. The quality
of the reconstructed image is arrived by the PSNR values. Based on
the results it can be concluded that the DCT has higher PSNR values
and FIC has higher compression ratio. Hence in medical image
compression, DCT can be used wherever picture quality is preferred
and FIC is used wherever compression of images for storage and
transmission is the priority, without loosing picture quality
diagnostically.
Abstract: Clusters of microcalcifications in mammograms are an
important sign of breast cancer. This paper presents a complete
Computer Aided Detection (CAD) scheme for automatic detection of
clustered microcalcifications in digital mammograms. The proposed
system, MammoScan μCaD, consists of three main steps. Firstly
all potential microcalcifications are detected using a a method for
feature extraction, VarMet, and adaptive thresholding. This will also
give a number of false detections. The goal of the second step,
Classifier level 1, is to remove everything but microcalcifications.
The last step, Classifier level 2, uses learned dictionaries and sparse
representations as a texture classification technique to distinguish
single, benign microcalcifications from clustered microcalcifications,
in addition to remove some remaining false detections. The system
is trained and tested on true digital data from Stavanger University
Hospital, and the results are evaluated by radiologists. The overall
results are promising, with a sensitivity > 90 % and a low false
detection rate (approx 1 unwanted pr. image, or 0.3 false pr. image).
Abstract: Breast skin-line estimation and breast segmentation is an important pre-process in mammogram image processing and computer-aided diagnosis of breast cancer. Limiting the area to be processed into a specific target region in an image would increase the accuracy and efficiency of processing algorithms. In this paper we are presenting a new algorithm for estimating skin-line and breast segmentation using fast marching algorithm. Fast marching is a partial-differential equation based numerical technique to track evolution of interfaces. We have introduced some modifications to the traditional fast marching method, specifically to improve the accuracy of skin-line estimation and breast tissue segmentation. Proposed modifications ensure that the evolving front stops near the desired boundary. We have evaluated the performance of the algorithm by using 100 mammogram images taken from mini-MIAS database. The results obtained from the experimental evaluation indicate that this algorithm explains 98.6% of the ground truth breast region and accuracy of the segmentation is 99.1%. Also this algorithm is capable of partially-extracting nipple when it is available in the profile.
Abstract: Texture classification is an important image processing
task with a broad application range. Many different techniques for
texture classification have been explored. Using sparse approximation
as a feature extraction method for texture classification is a relatively
new approach, and Skretting et al. recently presented the Frame
Texture Classification Method (FTCM), showing very good results on
classical texture images. As an extension of that work the FTCM is
here tested on a real world application as detection of abnormalities
in mammograms. Some extensions to the original FTCM that are
useful in some applications are implemented; two different smoothing
techniques and a vector augmentation technique. Both detection of
microcalcifications (as a primary detection technique and as a last
stage of a detection scheme), and soft tissue lesions in mammograms
are explored. All the results are interesting, and especially the results
using FTCM on regions of interest as the last stage in a detection
scheme for microcalcifications are promising.
Abstract: Mammographic images and data analysis to
facilitate modelling or computer aided diagnostic (CAD) software development should best be done using a common database that can handle various mammographic image file
formats and relate these to other patient information.
This would optimize the use of the data as both primary
reporting and enhanced information extraction of research data could be performed from the single dataset. One desired
improvement is the integration of DICOM file header information into the database, as an efficient and reliable source of supplementary patient information intrinsically
available in the images.
The purpose of this paper was to design a suitable database to link and integrate different types of image files and gather common information that can be further used for research
purposes. An interface was developed for accessing, adding,
updating, modifying and extracting data from the common
database, enhancing the future possible application of the data in CAD processing.
Technically, future developments envisaged include the creation of an advanced search function to selects image files
based on descriptor combinations. Results can be further used for specific CAD processing and other research. Design of a
user friendly configuration utility for importing of the required fields from the DICOM files must be done.
Abstract: A mammography image is composed of low contrast area where the breast tissues and the breast abnormalities such as microcalcification can hardly be differentiated by the medical practitioner. This paper presents the application of active contour models (Snakes) for the segmentation of microcalcification in mammography images. Comparison on the microcalcifiation areas segmented by the Balloon Snake, Gradient Vector Flow (GVF) Snake, and Distance Snake is done against the true value of the microcalcification area. The true area value is the average microcalcification area in the original mammography image traced by the expert radiologists. From fifty images tested, the result obtained shows that the accuracy of the Balloon Snake, GVF Snake, and Distance Snake in segmenting boundaries of microcalcification are 96.01%, 95.74%, and 95.70% accuracy respectively. This implies that the Balloon Snake is a better segmentation method to locate the exact boundary of a microcalcification region.
Abstract: X-ray mammography is the most effective method for
the early detection of breast diseases. However, the typical diagnostic
signs such as microcalcifications and masses are difficult to detect
because mammograms are of low-contrast and noisy. In this paper, a
new algorithm for image denoising and enhancement in Orthogonal
Polynomials Transformation (OPT) is proposed for radiologists to
screen mammograms. In this method, a set of OPT edge coefficients
are scaled to a new set by a scale factor called OPT scale factor. The
new set of coefficients is then inverse transformed resulting in
contrast improved image. Applications of the proposed method to
mammograms with subtle lesions are shown. To validate the
effectiveness of the proposed method, we compare the results to
those obtained by the Histogram Equalization (HE) and the Unsharp
Masking (UM) methods. Our preliminary results strongly suggest
that the proposed method offers considerably improved enhancement
capability over the HE and UM methods.
Abstract: An image texture analysis and target recognition approach of using an improved image texture feature coding method (TFCM) and Support Vector Machine (SVM) for target detection is presented. With our proposed target detection framework, targets of interest can be detected accurately. Cascade-Sliding-Window technique was also developed for automated target localization. Application to mammogram showed that over 88% of normal mammograms and 80% of abnormal mammograms can be correctly identified. The approach was also successfully applied to Synthetic Aperture Radar (SAR) and Ground Penetrating Radar (GPR) images for target detection.
Abstract: Mammography is the most effective procedure for an
early diagnosis of the breast cancer. Nowadays, people are trying to
find a way or method to support as much as possible to the
radiologists in diagnosis process. The most popular way is now being
developed is using Computer-Aided Detection (CAD) system to
process the digital mammograms and prompt the suspicious region to
radiologist. In this paper, an automated CAD system for detection
and classification of massive lesions in mammographic images is
presented. The system consists of three processing steps: Regions-Of-
Interest detection, feature extraction and classification. Our CAD
system was evaluated on Mini-MIAS database consisting 322
digitalized mammograms. The CAD system-s performance is
evaluated using Receiver Operating Characteristics (ROC) and Freeresponse
ROC (FROC) curves. The archived results are 3.47 false
positives per image (FPpI) and sensitivity of 85%.