Abstract: Structural performance and seismic vulnerability of
masonry buildings in Algeria are investigated in this paper. Structural
classification of such buildings is carried out regarding their
structural elements. Seismicity of Algeria is briefly discussed. Then
vulnerability of masonry buildings and their failure mechanisms in
the Boumerdes earthquake (May, 2003) are examined.
Abstract: Most buildings have been using anchor bolts
commonly for installing outdoor advertising structures. Anchor bolts
of common carbon steel are widely used and often installed
indiscriminately by inadequate installation standards. In the area
where strong winds frequently blow, falling accidents of outdoor
advertising structures can occur and cause a serious disaster, which is
very dangerous and to be prevented. In this regard, the development of
high-performance anchor bolts is urgently required. In the present
study, 25Cr-8Ni-1.5Si-1Mn-0.4C alloy was produced by traditional
vacuum induction melting (VIM) for the application of anchor bolt.
The alloy composition is revealed as a duplex microstructure from
thermodynamic phase analysis by FactSage® and confirmed by
metallographic experiment. Addition of Nitrogen to the alloy was
found to reduce the ferritic phase domain and significantly increase the
hardness and the tensile strength. Microstructure observation revealed
mixed structure of austenite and ferrite with fine carbide distributed
along the grain and phase boundaries.
Abstract: The increasing demand for sufficient and clean
energy forces industrial and service companies to align their strategies towards efficient consumption. This trend refers also to the
residential building sector. There, large amounts of energy consumption are caused by house and facility heating. Many of the
operated hot water heating systems lack hydraulic balanced working
conditions for heat distribution and –transmission and lead to
inefficient heating. Through hydraulic balancing of heating systems,
significant energy savings for primary and secondary energy can be
achieved. This paper addresses the use of KNX-technology (Smart
Buildings) in residential buildings to ensure a dynamic adaption of
hydraulic system's performance, in order to increase the heating
system's efficiency. In this paper, the procedure of heating system
segmentation into hydraulically independent units (meshes) is
presented. Within these meshes, the heating valve are addressed and
controlled by a central facility server. Feasibility criteria towards
such drivers will be named. The dynamic hydraulic balance is
achieved by positioning these valves according to heating loads, that
are generated from the temperature settings in the corresponding
rooms. The energetic advantages of single room heating control
procedures, based on the application FacilityManager, is presented.
Abstract: Three dimensional simulations are carried out to estimate the effect of wind direction, wind speed and geometry on the flow and dispersion of vehicular pollutant in a street canyon. The pollutant sources are motor vehicles passing between the two buildings. Suitable emission factors for petrol and diesel vehicles at varying vehicle speed are used for the estimation of the rate of emission from the streets. The dispersion of automobile pollutant released from the street is simulated by introducing vehicular emission source term as a fixed-flux boundary condition at the ground level over the road. The emission source term is suitably calculated by adopting emission factors from literature for varying conditions of street traffic. It is observed that increase in wind angle disturbs the symmetric pattern of pollution distribution along the street length. The concentration increases in the far end of the street as compared to the near end.
Abstract: The wide increase and diffusion on telecommunication
technologies have caused a huge spread of electromagnetic sources
in most European Countries. Since the public is continuously being
exposed to electromagnetic radiation the possible health effects have
become the focus of population concerns. As a result, electromagnetic
field monitoring stations which control field strength in commercial
frequency bands are being placed on the flat roof of many buildings.
However there is no guidance on where to place them. This paper
presents an analysis of frequency, polarization and angles of incidence
of a plane wave which impinges on a flat roof security wall and its
dependence on electromagnetic field strength meters placement.
Abstract: The building sector is the largest energy consumer and
CO2 emitter in the European Union (EU) and therefore the active
reduction of energy consumption and elimination of energy wastage
are among the main goals in it. Healthy housing and energy
efficiency are affected by many factors which set challenges to
monitoring, control and research of indoor air quality (IAQ) and
energy consumption, especially in old buildings. These challenges
include measurement and equipment costs, for example.
Additionally, the measurement results are difficult to interpret and
their usage in the ventilation control is also limited when taking into
account the energy efficiency of housing at the same time. The main
goal of this study is to develop a cost-effective building monitoring
and control system especially for old buildings. The starting point or
keyword of the development process is a wireless system; otherwise
the installation costs become too high. As the main result, this paper
describes an idea of a wireless building monitoring and control
system. The first prototype of the system has been installed in 10
residential buildings and in 10 school buildings located in the City of
Kuopio, Finland.
Abstract: Iranians- imagination of heaven, which is the reward
of a person-s good deeds during their life, has shown itself in
pleasant and green gardens where earthly gardens were made as
representations of paradise. Iranians are also quite interested in
making their earthly gardens and plantations around their buildings.
With Iran-s hot and dry climate with a lack of sufficient water for
plantation coverage, it becomes noticeable how important it is to
Iranians- art in making gardens. This study, with regard to examples,
documents and library studies, investigates the characteristics of
Persian gardens. The result shows that elements such as soil, water,
plants and layout have been used in forming a unique style of Persian
gardens. Bagh-e Shah Zadeh Mahan (Mahan prince garden) is a
typical example and has been carefully studied. In this paper I try to
investigate and evaluate the characteristics of a Persian garden by
means of a descriptive approach.
Abstract: Recordings from recent earthquakes have provided evidence that ground motions in the near field of a rupturing fault differ from ordinary ground motions, as they can contain a large energy, or “directivity" pulse. This pulse can cause considerable damage during an earthquake, especially to structures with natural periods close to those of the pulse. Failures of modern engineered structures observed within the near-fault region in recent earthquakes have revealed the vulnerability of existing RC buildings against pulse-type ground motions. This may be due to the fact that these modern structures had been designed primarily using the design spectra of available standards, which have been developed using stochastic processes with relatively long duration that characterizes more distant ground motions. Many recently designed and constructed buildings may therefore require strengthening in order to perform well when subjected to near-fault ground motions. Fiber Reinforced Polymers are considered to be a viable alternative, due to their relatively easy and quick installation, low life cycle costs and zero maintenance requirements. The objective of this paper is to investigate the adequacy of Artificial Neural Networks (ANN) to determine the three dimensional dynamic response of FRP strengthened RC buildings under the near-fault ground motions. For this purpose, one ANN model is proposed to estimate the base shear force, base bending moments and roof displacement of buildings in two directions. A training set of 168 and a validation set of 21 buildings are produced from FEA analysis results of the dynamic response of RC buildings under the near-fault earthquakes. It is demonstrated that the neural network based approach is highly successful in determining the response.
Abstract: Accurate evaluation of damping ratios involving soilstructure interaction (SSI) effects is the prerequisite for seismic design of in-situ buildings. This study proposes a combined approach to identify damping ratios of SSI systems based on ambient excitation technique. The proposed approach is illustrated with main test process, sampling principle and algorithm steps through an engineering example, as along with its feasibility and validity. The proposed approach is employed for damping ratio identification of 82 buildings in Xi-an, China. Based on the experimental data, the variation range and tendency of damping ratios of these SSI systems, along with the preliminary influence factor, are shown and discussed. In addition, a fitting curve indicates the relation between the damping ratio and fundamental natural period of SSI system.
Abstract: One of the potential and effective ways of
storing thermal energy in buildings is the integration of brick with phase change materials (PCMs). This paper presents a two-dimensional model for simulating and analyzing of PCM
in order to minimize energy consumption in the buildings. The numerical approach has been used with the real weather data of a selected city of Iran (Tehran). Two kinds of brick integrated PCM are investigated and compared base on
outdoor weather conditions and the amount of energy
consumption. The results show a significant reduction in
maximum entering heat flux to building about 32.8%
depending on PCM quantity. The results are analyzed by
various temperature contour plots. The contour plots
illustrated the time dependent mechanism of entering heat flux for a brick integrated with PCM. Further analysis is developed to investigate the effect of PCM location on the inlet heat flux. The results demonstrated that to achieve maximum performance of PCM it is better to locate PCM near the outdoor.
Abstract: A preliminary evaluation of the feasibility of installing small wind turbines on offshore oil and gas extraction platforms is presented. Some aerodynamic considerations are developed in order to determine the best rotor architecture to exploit the wind potential on such installations, assuming that wind conditions over the platforms are similar to those registered on the roofs of urban buildings. Economical considerations about both advantages and disadvantages of the exploitation of wind energy on offshore extraction platforms with respect to conventional offshore wind plants, is also presented. Finally, wind charts of European offshore winds are presented together with a map of the major offshore installations.
Abstract: Growing world population has fundamental impacts
and often catastrophic on natural habitat. The immethodical
consumption of energy, destruction of the forests and extinction of
plant and animal species are the consequence of this experience.
Urban sustainability and sustainable urban development, that is so
spoken these days, should be considered as a strategy, goal and
policy, beyond just considering environmental issues and protection.
The desert-s climate has made a bunch of problems for its residents.
Very hot and dry climate in summers of the Iranian desert areas,
when there was no access to modern energy source and mechanical
cooling systems in the past, made Iranian architects to design a
natural ventilation system in their buildings. The structure, like a
tower going upward the roof, besides its ornamental application and
giving a beautiful view to the building, was used as a spontaneous
ventilation system. In this paper, it has been tried to name the
problems of the area and it-s inconvenience, then some answers has
pointed out in order to solve the problems and as an alternative
solution BADGIR (wind-catcher) has been introduced as a solution
knowing that it has been playing a major role in dealing with the
problems.
Abstract: The unanticipated brittle fracture of connection of the
steel moment resisting frame (SMRF) occurred in 1994 the Northridge
earthquake. Since then, the researches for the vulnerability of
connection of the existing SMRF and for rehabilitation of those
buildings were conducted. This paper suggests performance-based
optimal seismic retrofit technique using connection upgrade. For
optimal design, a multi-objective genetic algorithm(NSGA-II) is used.
One of the two objective functions is to minimize initial cost and
another objective function is to minimize lifetime seismic damages
cost. The optimal algorithm proposed in this paper is performed
satisfying specified performance objective based on FEMA 356. The
nonlinear static analysis is performed for structural seismic
performance evaluation. A numerical example of SAC benchmark
SMRF is provided using the performance-based optimal seismic
retrofit technique proposed in this paper
Abstract: The proposed paper examines strategies whose aim is
to counter the all too often sighted process of abandonment that
characterizes contemporary cities. The city of Nicosia in Cyprus is
used as an indicative case study, whereby several recent projects are
presented as capitalizing on traditional cultural assets to revive the
downtown. The reuse of existing building stock as museums,
performing arts centers and theaters but also as in the form of various
housing typologies is geared to strengthen the ranks of local residents
and to spur economic growth. Unlike the examples from the 1960s,
the architecture of more recent adaptive reuse for urban regeneration
seems to be geared in reinforcing a connection to the city where the
buildings often reflect the characteristics of their urban context.
Abstract: Light is one of the most important qualitative and
symbolic factors and has a special position in architecture and urban
development in regard to practical function. The main function of
light, either natural or artificial, is lighting up the environment and
the constructional forms which is called lighting. However, light is
used to redefine the urban spaces by architectural genius with regard
to three aesthetic, conceptual and symbolic factors. In architecture
and urban development, light has a function beyond lighting up the
environment, and the designers consider it as one of the basic
components. The present research aims at studying the function of
light and color in architectural view and their effects in buildings.
Abstract: Explosions may cause intensive damage to buildings
and sometimes lead to total and progressive destruction. Pressures
induced by explosions are one of the most destructive loads a
structure may experience. While designing structures for great
explosions may be expensive and impractical, engineers are looking
for methods for preventing destructions resulted from explosions. A
favorable structural system is a system which does not disrupt totally
due to local explosion, since such structures sustain less loss in
comparison with structural ones which really bear the load and
suddenly disrupt. Designing and establishing vital and necessary
installations in a way that it is resistant against direct hit of bomb and
rocket is not practical, economical, or expedient in many cases,
because the cost of construction and installation with such
specifications is several times more than the total cost of the related
equipment.
Abstract: Several models of vulnerability assessment have been proposed. The selection of one of these models depends on the objectives of the study. The classical methodologies for seismic vulnerability analysis, as a part of seismic risk analysis, have been formulated with statistical criteria based on a rapid observation. The information relating to the buildings performance is statistically elaborated. In this paper, we use the European Macroseismic Scale EMS-98 to define the relationship between damage and macroseismic intensity to assess the seismic vulnerability. Applying to Algiers area, the first step is to identify building typologies and to assign vulnerability classes. In the second step, damages are investigated according to EMS-98.
Abstract: The benefits of rooftop greenery systems (such as
energy savings, reduction of greenhouse gas emission for mitigating
climate change and maintaining sustainable development, indoor
temperature control etc.) in buildings are well recognized, however
there remains very little research conducted for quantifying the
benefits in subtropical climates such as in Australia. This study
mainly focuses on measuring/determining temperature profile and air
conditioning energy savings by implementing rooftop greenery
systems in subtropical Central Queensland in Australia. An
experimental set-up was installed at Rockhampton campus of Central
Queensland University, where two standard shipping containers (6m
x 2.4m x 2.4m) were converted into small offices, one with green
roof and one without. These were used for temperature, humidity and
energy consumption data collection. The study found that an energy
savings of up to 11.70% and temperature difference of up to 4°C can
be achieved in March in subtropical Central Queensland climate in
Australia. It is expected that more energy can be saved in peak
summer days (December/February) as temperature difference
between green roof and non-green roof is higher in December-
February.
Abstract: Certifications such as the Passive House Standard aim to reduce the final space heating energy demand of residential buildings. Space conditioning, notably heating, is responsible for nearly 70% of final residential energy consumption in Europe. There is therefore significant scope for the reduction of energy consumption through improvements to the energy efficiency of residential buildings. However, these certifications totally overlook the energy embodied in the building materials used to achieve this greater operational energy efficiency. The large amount of insulation and the triple-glazed high efficiency windows require a significant amount of energy to manufacture. While some previous studies have assessed the life cycle energy demand of passive houses, including their embodied energy, these rely on incomplete assessment techniques which greatly underestimate embodied energy and can lead to misleading conclusions. This paper analyses the embodied and operational energy demands of a case study passive house using a comprehensive hybrid analysis technique to quantify embodied energy. Results show that the embodied energy is much more significant than previously thought. Also, compared to a standard house with the same geometry, structure, finishes and number of people, a passive house can use more energy over 80 years, mainly due to the additional materials required. Current building energy efficiency certifications should widen their system boundaries to include embodied energy in order to reduce the life cycle energy demand of residential buildings.
Abstract: This study was investigated on sampling and
analyzing water quality in water reservoir & water tower installed in
two kind of residential buildings and school facilities. Data of water
quality was collected for correlation analysis with frequency of
sanitization of water reservoir through questioning managers of
building about the inspection charts recorded on equipment for water
reservoir. Statistical software packages (SPSS) were applied to the
data of two groups (cleaning frequency and water quality) for
regression analysis to determine the optimal cleaning frequency of
sanitization. The correlation coefficient (R) in this paper represented
the degree of correlation, with values of R ranging from +1 to -1.After
investigating three categories of drinking water users; this study found
that the frequency of sanitization of water reservoir significantly
influenced the water quality of drinking water. A higher frequency of
sanitization (more than four times per 1 year) implied a higher quality
of drinking water. Results indicated that sanitizing water reservoir &
water tower should at least twice annually for achieving the aim of
safety of drinking water.