Abstract: Chevron frames (Inverted-V-braced frames or Vbraced
frames) have seismic disadvantages, such as not good exhibit force redistribution capability and compression brace buckles
immediately. Researchers developed new design provisions on
increasing both the ductility and lateral resistance of these structures
in seismic areas. One of these new methods is adding zipper columns, as proposed by Khatib et al. (1988) [2]. Zipper columns are
vertical members connecting the intersection points of the braces
above the first floor. In this paper applicability of the suspended
zipper system to Seismic Rehabilitation of Steel Structures is investigated.
The models are 3-, 6-, 9-, and 12-story Inverted-V-braced frames.
In this case, it is assumed that the structures must be rehabilitated. For rehabilitation of structures, zipper column is used. The result of
researches showed that the suspended zipper system is effective in
case of 3-, 6-, and 9-story Inverted-V-braced frames and it would
increase lateral resistance of structure up to life safety level. But in
case of high-rise buildings (such as 12 story frame), it doesn-t show
good performance. For solving this problem, the braced bay can
consist of small “units" over the height of the entire structure, which each of them is a zipper-braced bay with a few stories. By using this
method the lateral resistance of 12 story Inverted-V-braced frames is increased up to safety life level.
Abstract: As the world move to the accomplishment of Performance Based Engineering philosophies in seismic design of Civil Engineering structures, new seismic design provisions require Structural Engineers to perform both static and dynamic analysis for the design of structures. While Linear Equivalent Static Analysis is performed for regular buildings up to 90m height in zone I and II, Dynamic Analysis should be performed for regular and irregular buildings in zone IV and V. Dynamic Analysis can take the form of a dynamic Time History Analysis or a linear Response Spectrum Analysis. In present study, Multi-storey irregular buildings with 20 stories have been modeled using software packages ETABS and SAP 2000 v.15 for seismic zone V in India. This paper also deals with the effect of the variation of the building height on the structural response of the shear wall building. Dynamic responses of building under actual earthquakes, EL-CENTRO 1949 and CHI-CHI Taiwan 1999 have been investigated. This paper highlights the accuracy and exactness of Time History analysis in comparison with the most commonly adopted Response Spectrum Analysis and Equivalent Static Analysis.
Abstract: In recent years, tuned mass damper (TMD) control systems for civil engineering structures have attracted considerable attention. This paper emphasizes on the application of particle swarm application (PSO) to design and optimize the parameters of the TMD control scheme for achieving the best results in the reduction of the building response under earthquake excitations. The Integral of the Time multiplied Absolute value of the Error (ITAE) based on relative displacement of all floors in the building is taken as a performance index of the optimization criterion. The problem of robustly TMD controller design is formatted as an optimization problem based on the ITAE performance index to be solved using the PSO technique which has a story ability to find the most optimistic results. An 11- story realistic building, located in the city of Rasht, Iran is considered as a test system to demonstrate effectiveness of the proposed method. The results analysis through the time-domain simulation and some performance indices reveals that the designed PSO based TMD controller has an excellent capability in reduction of the seismically excited example building.
Abstract: Demolitions of buildings have created a lot of waste
and one of it is clay bricks. The waste clay bricks were ground to
roughly cement fineness and used to partially replaced cement at
10%, 20% and 30% with w/b ratio of 0.6 and tested at 7, 28, 60, 90
and 120 days. The result shows that the compressive strength of GCB
concrete increases over age however, decreases as the level of
replacements increases. It was also found that 10% replacement of
GCB gave the highest compressive strength, however for optimum
replacement, 30% was chosen as it still attained strength of grade 30
concrete. In terms of durability performances, results show that GCB
replacement up to 30% was found to be efficient in reducing water
absorption as well as water permeability. These studies show that
GCB has the potential to be used as partial cement replacement in
making concrete.
Abstract: We study dynamic instability in high-rise steel moment
resisting frames (SMRFs) subjected to synthetic long-period ground
motions caused by hypothetical huge subduction earthquakes. Since
long duration as well as long dominant periods is a characteristic of
long-period ground motions, interstory drifts may enter the negative
postyield stiffness range many times when high-rise buildings are
subjected to long-period ground motions. Through the case studies of
9 high-rise SMRFs designed in accordance with the Japanese design
practice in 1980s, we demonstrate that drifting, or accumulation of
interstory drifts in one direction, occurs at the lower stories of the
SMRFs, if their natural periods are close to the dominant periods of the
long-period ground motions. The drifting led to residual interstory
drift ratio over 0.01, or to collapse if the design base shear was small.
Abstract: Buildings and associated construction methods have a significant impact on the environment. As construction activity increases in Kuwait, there is a need to create design and construction strategies which will minimize the environmental impact of new buildings. Green construction is a design philosophy intended to improve the sustainability of construction by the minimization of resource depletion and CO2 emissions throughout the life cycle of buildings. This paper presents and discusses the results of a survey that was conducted in Kuwait, with the objective of investigating the awareness of developers and other stakeholders regarding their understanding and use of green construction strategies. The results of the survey demonstrate that whilst there seems to be a reasonable level of awareness amongst the stakeholders, this awareness is not currently well reflected in the design and construction practices actually being applied. It is therefore concluded is there is a pressing need for intervention from Government in order that the use of sustainable green design and construction strategies becomes the norm in Kuwait.
Abstract: The CMLP building was developed to be a model for
sustainability with strategies to reduce water, energy and pollution,
and to provide a healthy environment for the building occupants. The
aim of this paper is to investigate the environmental effects of energy
used by this building. A LCA (life cycle analysis) was led to measure
the real environmental effects produced by the use of energy. The
impact categories most affected by the energy use were found to be
the human health effects, as well as ecotoxicity. Natural gas
extraction, uranium milling for nuclear energy production, and the
blasting for mining and infrastructure construction are the processes
contributing the most to emissions in the human health effect. Data
comparing LCA results of CMLP building with a conventional
building results showed that energy used by the CMLP building has
less damage for the environment and human health than a
conventional building.
Abstract: Because of architectural condition and structure application, sometimes mass source and stiffness source are not coincidence, and the structure is irregular. The structure is also might be asymmetric as an asymmetric bracing in plan which leads to unbalance distribution of stiffness or because of unbalance distribution of the mass. Both condition lead to eccentricity and torsion in the structure. The deficiency of ordinary code to evaluate the performance of steel structures against earthquake has been caused designing based on performance level or capacity spectrum be used. By using the mentioned methods it is possible to design a structure that its behavior against different earthquakes be predictive. In this article 5- story buildings with different percentage of asymmetric which is because of stiffness changes have been designed. The static and dynamic nonlinear analysis under three acceleration recording has been done. Finally performance level of the structure has been evaluated.
Abstract: In this study, a fuzzy-logic based control system was
designed to ensure that time and energy is saved during the operation
of load elevators which are used during the construction of tall
buildings. In the control system that was devised, for the load
elevators to work more efficiently, the energy interval where the
motor worked was taken as the output variable whereas the amount
of load and the building height were taken as input variables. The
most appropriate working intervals depending on the characteristics
of these variables were defined by the help of an expert. Fuzzy expert
system software was formed using Delphi programming language. In
this design, mamdani max-min inference mechanism was used and
the centroid method was employed in the clarification procedure. In
conclusion, it is observed that the system that was designed is
feasible and this is supported by statistical analyses..
Abstract: This paper describes a prototype aircraft that can fly
slowly, safely and transmit wireless video for tasks like reconnaissance,
surveillance and target acquisition. The aircraft is designed to
fly in closed quarters like forests, buildings, caves and tunnels which
are often spacious but GPS reception is poor. Envisioned is that a
small, safe and slow flying vehicle can assist in performing dull,
dangerous and dirty tasks like disaster mitigation, search-and-rescue
and structural damage assessment.
Abstract: Natural ventilation has played an important role for
many low energy-building designs. It has been also noticed as a
essential subject to persistently bring the fresh cool air from the
outside into a building. This study carried out the computational fluid
dynamics (CFD)-based simulations to examine the natural ventilation
development of a work area in a public building. The simulated results
can be useful to better understand the indoor microclimate and the
interaction of wind with buildings. Besides, this CFD simulation
procedure can serve as an effective analysis tool to characterize the
airing performance, and thereby optimize the building ventilation for
strengthening the architects, planners and other decision makers on
improving the natural ventilation design of public buildings.
Abstract: The implementations of green roof have been widely
used in the developed countries such as Germany, United Kingdom,
United States and Canada. Green roof have many benefits such as
aesthetic and economic value, ecological gain which are optimization
of storm water management, urban heat island mitigation and energy
conservation. In term of pollution, green roof can control the air and
noise pollution in urban cities. The application of green roof in
Malaysian building has been studied with the previous work of green
roof either in Malaysia or other Asian region as like Indonesia,
Singapore, Thailand, Taiwan and several other countries that have
similar climate and environment as in Malaysia. These technologies
of adapting green roof have been compared to the Green Building
Index (GBI) of Malaysian buildings. The study has concentrated on
the technical aspect of green roof system having focused on i) waste
& recyclable materials ii) types of plants and method of planting and
iii) green roof as tool to reduce storm water runoff. The finding of
these areas will be compared to the suitability in achieving good
practice of the GBI in Malaysia. Results show that most of the
method are based on the countries own climate and environment.
This suggests that the method of using green roof must adhere to the
tropical climate of Malaysia. Suggestion of this research will be
viewed in term of the sustainability of the green roof. Further
research can be developed to implement the best method and
application in Malaysian climate especially in urban cities and
township.
Abstract: A seismic isolation pad produced by utilizing the scrap
tire rubber which contains interleaved steel reinforcing cords has been
proposed. The steel cords are expected to function similar to the steel
plates used in conventional laminated rubber bearings. The scrap tire
rubber pad (STRP) isolator is intended to be used in low rise
residential buildings of highly seismic areas of the developing
countries. Experimental investigation was conducted on unbonded
STRP isolators, and test results provided useful information including
stiffness, damping values and an eventual instability of the isolation
unit. Finite element analysis (FE analysis) of STRP isolator was
carried out on properly bonded samples. These types of isolators
provide positive incremental force resisting capacity up to shear strain
level of 155%. This paper briefly discusses the force deformation
behavior of bonded STRP isolators including stability of the isolation
unit.
Abstract: This paper explains the cause of nonlinearity in floor
attenuation hither to left unexplained. The performance degradation
occurring in air interface for GSM signals is quantitatively analysed
using the concept of Radiating Columns of buildings. The signal
levels were measured using Wireless Network Optimising Drive Test
Tool (E6474A of Agilent Technologies). The measurements were
taken in reflected signal environment under usual fading conditions
on actual GSM signals radiated from base stations. A mathematical
model is derived from the measurements to predict the GSM signal
levels in different floors. It was applied on three buildings and found
that the predicted signal levels deviated from the measured levels
with in +/- 2 dB for all floors. It is more accurate than the prediction
models based on Floor Attenuation Factor. It can be used for
planning proper indoor coverage in multi storey buildings.
Abstract: Recent years, adaptive pushover methods have been
developed for seismic analysis of structures. Herein, the accuracy of
the displacement-based adaptive pushover (DAP) method, which is
introduced by Antoniou and Pinho [2004], is evaluated for Irregular
buildings. The results are compared to the force-based procedure.
Both concrete and steel frame structures, asymmetric in plan and
elevation are analyzed and also torsional effects are taking into the
account. These analyses are performed using both near fault and far
fault records. In order to verify the results, the Incremental Dynamic
Analysis (IDA) is performed.
Abstract: Terminal localization for indoor Wireless Local Area
Networks (WLANs) is critical for the deployment of location-aware
computing inside of buildings. A major challenge is obtaining high
localization accuracy in presence of fluctuations of the received signal
strength (RSS) measurements caused by multipath fading. This paper
focuses on reducing the effect of the distance-varying noise by spatial
filtering of the measured RSS. Two different survey point geometries
are tested with the noise reduction technique: survey points arranged
in sets of clusters and survey points uniformly distributed over the
network area. The results show that the location accuracy improves
by 16% when the filter is used and by 18% when the filter is applied
to a clustered survey set as opposed to a straight-line survey set.
The estimated locations are within 2 m of the true location, which
indicates that clustering the survey points provides better localization
accuracy due to superior noise removal.
Abstract: In many buildings we rely on large footings to offer
structural stability. Designers often compensate for the lack of
knowledge available with regard to foundation-soil interaction by
furnishing structures with overly large footings. This may lead to a
significant increase in building expenditures if many large
foundations are present. This paper describes the interface material
law that governs the behavior along the contact surface of adjacent
materials, and the behavior of a large foundation under ultimate limit
loading. A case study is chosen that represents a common
foundation-soil system frequently used in general practice and
therefore relevant to other structures. Investigations include
compressing versus uplifting wind forces, alterations to the
foundation size and subgrade compositions, the role of the slab
stiffness and presence and the effect of commonly used structural
joints and connections. These investigations aim to provide the
reader with an objective design approach, efficiently preventing
structural instability.
Abstract: The purpose of this paper is to investigate the adjust-
ment of solar shading devices in office buildings in two different
seasons by occupants, and its influence on the lighting control and
indoor illuminance levels. The results show that occupants take
inappropriate measures both in reducing solar radiation in summer
and in admitting solar gains in winter, resulting in an increase in
lighting energy and a reduction in indoor illuminance. Therefore,
movable shading devices, controlled automatically, are suitable for
building applications to reduce energy consumption.
Abstract: To investigate the energy performance of solar shading devices, this paper carried out a survey on the current status of solar shading utilization in buildings in Ningbo and performed building simulations to evaluate the energy savings potential by adopting different solar shading devices. Results show that solar shading utilization in this area is not popular and effective, and should be considered firstly in the design stage since the potential for energy savings is up to 6.8% for residential buildings and 9.4% for commercial buildings.
Abstract: In this study, active tendons with Proportional Integral
Derivation type controllers were applied to a SDOF and a MDOF
building model. Physical models of buildings were constituted with
virtual springs, dampers and rigid masses. After that, equations of
motion of all degrees of freedoms were obtained. Matlab Simulink
was utilized to obtain the block diagrams for these equations of
motion. Parameters for controller actions were found by using a trial
method. After earthquake acceleration data were applied to the
systems, building characteristics such as displacements, velocities,
accelerations and transfer functions were analyzed for all degrees of
freedoms. Comparisons on displacement vs. time, velocity vs. time,
acceleration vs. time and transfer function (Db) vs. frequency (Hz)
were made for uncontrolled and controlled buildings. The results
show that the method seems feasible.