Abstract: This paper presents a resonant-based read-out circuit for capacitive pressure sensors. The proposed read-out circuit consists of an LC oscillator and a counter. The circuit detects the capacitance changes of a capacitive pressure sensor by means of frequency shifts from its nominal operation frequency. The proposed circuit is designed in 0.18m CMOS with an estimated power consumption of 43.1mW. Simulation results show that the circuit has a capacitive resolution of 8.06kHz/fF, which enables it for high resolution pressure detection.
Abstract: The interaction between respiration and low-frequency rhythms of the cardiovascular system is studied. The obtained results count in favor of the hypothesis that low-frequency rhythms in blood pressure and R-R intervals are generated in different central neural structures involved in the autonomic control of the cardiovascular systems.
Abstract: This paper presents comparison among methods of
determination of the characteristic polynomial coefficients. First, the
resultant systems from the methods are compared based on frequency
criteria such as the closed loop bandwidth, gain and phase margins.
Then the step responses of the resultant systems are compared on the
basis of the transient behavior criteria including overshoot, rise time,
settling time and error (via IAE, ITAE, ISE and ITSE integral
indices). Also relative stability of the systems is compared together.
Finally the best choices in regards to the above diverse criteria are
presented.
Abstract: Measuring the effect of perinatal lead exposure on learning ability of offspring is considered as a sensitive and selective index for providing an early marker for central nervous system damage produced by this toxic metal. A total of 35 Sprague-Dawley adult rats were used to investigate the effect of lead acetate toxicity on behavioral patterns of adult female rats and learning ability of offspring. Rats were allotted into 4 groups, group one received 1g/l lead acetate (n=10), group two received 1.5g/l lead acetate (n=10), group three received 2g/l lead acetate in drinking water (n=10) and control group did not receive lead acetate (n=5) from 8th day of pregnancy till weaning of pups.
The obtained results revealed a dose dependent increase in the feeding time, drinking frequency, licking frequency, scratching frequency, licking litters, nest building and retrieving frequencies, while standing time increased significantly in rats treated with 1.5g/l lead acetate than other treated groups and control, on contrary lying time decreased gradually in a dose dependent manner. Moreover, movement activities were higher in rats treated with 1g/l lead acetate than other treated groups and control. Furthermore, time spent in closed arms was significantly lower in rats given 2g/l lead acetate than other treated groups, while, they spent significantly much time spent in open arms than other treated groups which could be attributed to occurrence of adaptation. Furthermore, number of entries in open arms was dose dependent. However, the ratio between open/closed arms revealed a significant decrease in rats treated with 2g/l lead acetate than control group.
Abstract: This paper aims to present the design, fabrication and test of a novel piezoelectric actuated, check-valves embedded micropump having the advantages of miniature size, light weight and low power consumption. This device is designed to pump gases and liquids with the capability of performing the self-priming and bubble-tolerant work mode by maximizing the stroke volume of the membrane as well as the compression ratio via minimization of the dead volume of the micropump chamber and channel. By experiment apparatus setup, we can get the real-time values of the flow rate of micropump, the displacement of the piezoelectric actuator and the deformation of the check valve, simultaneously. The micropump with check valve 0.4 mm in thickness obtained higher output performance under the sinusoidal waveform of 120 Vpp. The micropump achieved the maximum pumping rates of 42.2 ml/min and back pressure of 14.0 kPa at the corresponding frequency of 28 and 20 Hz. The presented micropump is able to pump gases with a pumping rate of 196 ml/min at operating frequencies of 280 Hz under the sinusoidal waveform of 120 Vpp.
Abstract: Turbulence of the incoming wind field is of paramount
importance to the dynamic response of civil engineering structures. Hence reliable stochastic models of the turbulence should be available from which time series can be generated for dynamic response and
structural safety analysis. In the paper an empirical cross spectral
density function for the along-wind turbulence component over the wind field area is taken as the starting point. The spectrum is spatially
discretized in terms of a Hermitian cross-spectral density matrix for the turbulence state vector which turns out not to be positive
definite. Since the succeeding state space and ARMA modelling of
the turbulence rely on the positive definiteness of the cross-spectral
density matrix, the problem with the non-positive definiteness of such
matrices is at first addressed and suitable treatments regarding it are proposed. From the adjusted positive definite cross-spectral density
matrix a frequency response matrix is constructed which determines the turbulence vector as a linear filtration of Gaussian white noise.
Finally, an accurate state space modelling method is proposed which allows selection of an appropriate model order, and estimation of a state space model for the vector turbulence process incorporating its phase spectrum in one stage, and its results are compared with a conventional ARMA modelling method.
Abstract: Power line channel is proposed as an alternative for broadband data transmission especially in developing countries like Tanzania [1]. However the channel is affected by stochastic attenuation and deep notches which can lead to the limitation of channel capacity and achievable data rate. Various studies have characterized the channel without giving exactly the maximum performance and limitation in data transfer rate may be this is due to complexity of channel modeling being used. In this paper the channel performance of medium voltage, low voltage and indoor power line channel is presented. In the investigations orthogonal frequency division multiplexing (OFDM) with phase shift keying (PSK) as carrier modulation schemes is considered, for indoor, medium and low voltage channels with typical ten branches and also Golay coding is applied for medium voltage channel. From channels, frequency response deep notches are observed in various frequencies which can lead to reduce the achievable data rate. However, is observed that data rate up to 240Mbps is realized for a signal to noise ratio of about 50dB for indoor and low voltage channels, however for medium voltage a typical link with ten branches is affected by strong multipath and coding is required for feasible broadband data transfer.
Abstract: The purpose of this paper is to propose a text mining
approach to evaluate companies- practices on affective management.
Affective management argues that it is critical to take stakeholders-
affects into consideration during decision-making process, along with
the traditional numerical and rational indices. CSR reports published
by companies were collected as source information. Indices were
proposed based on the frequency and collocation of words relevant to
affective management concept using text mining approach to analyze
the text information of CSR reports. In addition, the relationships
between the results obtained using proposed indices and traditional
indicators of business performance were investigated using
correlation analysis. Those correlations were also compared between
manufacturing and non-manufacturing companies. The results of this
study revealed the possibility to evaluate affective management
practices of companies based on publicly available text documents.
Abstract: Multicarrier transmission system such as Orthogonal
Frequency Division Multiplexing (OFDM) is a promising technique
for high bit rate transmission in wireless communication systems.
OFDM is a spectrally efficient modulation technique that can achieve
high speed data transmission over multipath fading channels without
the need for powerful equalization techniques. A major drawback
of OFDM is the high Peak-to-Average Power Ratio (PAPR) of the
transmit signal which can significantly impact the performance of the
power amplifier. In this paper we have compared the PAPR reduction
performance of Golay and Reed-Muller coded OFDM signal. From
our simulation it has been found that the PAPR reduction performance
of Golay coded OFDM is better than the Reed-Muller coded OFDM
signal. Moreover, for the optimum PAPR reduction performance, code
configuration for Golay and Reed-Muller codes has been identified.
Abstract: This paper investigates the impact of the hand-hold
positions on both antenna performance and the specific absorption
rate (SAR) induced in the user-s head. A cellular handset with
external antenna operating at GSM-900 frequency is modeled and
simulated using a finite difference time-domain (FDTD)-based
platform SEMCAD-X. A specific anthropomorphic mannequin
(SAM) is adopted to simulate the user-s head, whereas a semirealistic
CAD-model of three-tissues is designed to simulate the
user-s hand. The results show that in case of the handset in hand close
to head at different positions; the antenna total efficiency gets
reduced to (14.5% - 5.9%) at cheek-position and to (27.5% to 11.8%)
at tilt-position. The peak averaged SAR1g values in head close to
handset without hand, are 4.67 W/Kg and 2.66 W/Kg at cheek and
tilt-position, respectively. Due to the presence of hand, the SAR1g in
head gets reduced to (3.67-3.31 W/Kg) at cheek-position and to
(1.84-1.64 W/Kg) at tilt-position, depending on the hand-hold
position.
Abstract: In this study, the performance of a high-frequency arc
welding machine including a two-switch inverter is analyzed. The
control of the system is achieved using two different control
techniques i- fuzzy logic control (FLC) ii- state space averaging
based sliding control. Fuzzy logic control does not need accurate
mathematical model of a plant and can be used in nonlinear
applications. The second method needs the mathematical model of
the system. In this method the state space equations of the system are
derived for two different “on" and “off" states of the switches. The
derived state equations are combined with the sliding control rule
considering the duty-cycle of the converter. The performance of the
system is analyzed by simulating the system using SIMULINK tool
box of MATLAB. The simulation results show that fuzzy logic
controller is more robust and less sensitive to parameter variations.
Abstract: A high-linearity and high-speed current-mode sampleand-
hold circuit is designed and simulated using a 0.25μm CMOS
technology. This circuit design is based on low voltage and it utilizes
a fully differential circuit. Due to the use of only two switches the
switch related noise has been reduced. Signal - dependent -error is
completely eliminated by a new zero voltage switching technique.
The circuit has a linearity error equal to ±0.05μa, i.e. 12-bit
accuracy with a ±160 μa differential output - input signal frequency
of 5MHZ, and sampling frequency of 100 MHZ. Third
harmonic is equal to –78dB.
Abstract: Operating a device at high power and high frequency
is a major problem because wall losses greatly reduce the efficiency
of the device. In the present communication, authors analytically
analyzed the dependence of ohmic/RF efficiency, the fraction of
output power with respect to the total power generated, of gyrotron
cavity structure on the conductivity of copper for the second
harmonic TE0,6 mode. This study shows a rapid fall in the RF
efficiency as the quality (conductivity) of copper degrades. Starting
with an RF efficiency near 40% at the conductivity of ideal copper
(5.8 x 107 S/m), the RF efficiency decreases (upto 8%) as the copper
quality degrades. Assuming conductivity half that of ideal copper the
RF efficiency as a function of diffractive quality factor, Qdiff, has
been studied. Here the RF efficiency decreases rapidly with
increasing diffractive Q. Ohmic wall losses as a function of
frequency for 460 GHz gyrotron cavity excited in TE0,6 mode has
also been analyzed. For 460 GHz cavity, the extracted power is
reduced to 32% of the generated power due to ohmic losses in the
walls of the cavity.
Abstract: The characterization and modeling of the dynamic
behavior of many built-up structures under vibration conditions is still
a subject of current research. The present study emphasizes the
theoretical investigation of slip damping in layered and jointed
welded cantilever structures using finite element approach.
Application of finite element method in damping analysis is relatively
recent, as such, some problems particularly slip damping analysis has
not received enough attention. To validate the finite element model
developed, experiments have been conducted on a number of mild
steel specimens under different initial conditions of vibration. Finite
element model developed affirms that the damping capacity of such
structures is influenced by a number of vital parameters such as;
pressure distribution, kinematic coefficient of friction and micro-slip
at the interfaces, amplitude, frequency of vibration, length and
thickness of the specimen. Finite element model developed can be
utilized effectively in the design of machine tools, automobiles,
aerodynamic and space structures, frames and machine members for
enhancing their damping capacity.
Abstract: In this work, new experimental data for slugging
frequency in inclined gas-liquid flow are reported, and a new
correlation is proposed. Scale experiments were carried out using a
mixture of air and water in a 6 m long pipe. Two different pipe
diameters were used, namely, 38 and 67 mm. The data were taken
with capacitance type sensors at a data acquisition frequency of 200
Hz over an interval of 60 seconds. For the range of flow conditions
studied, the liquid superficial velocity is observed to influence the
frequency strongly. A comparison of the present data with
correlations available in the literature reveals a lack of agreement. A
new correlation for slug frequency has been proposed for the inclined
flow, which represents the main contribution of this work.
Abstract: The impact of rain attenuation on wireless communication signals is predominant because of the used high frequency (above 10 GHz). The knowledge of statistics of attenuation is very important for planning point-to-point microwave links operating in high frequency band. Describing the statistics of attenuation is possible for instance with fade duration or level crossing rate. In our examination we determine these statistics from one year measured data for a given microwave link, and we are going to make an attempt to transform the level crossing rate statistic to fade duration statistic.
Abstract: There are multiple ways to implement a decimator
filter. This paper addresses usage of CIC (cascaded-integrator-comb)
filter and HB (half band) filter as the decimator filter to reduce the
frequency sample rate by factor of 64 and detail of the
implementation step to realize this design in hardware. Low power
design approach for CIC filter and half band filter will be discussed.
The filter design is implemented through MATLAB system
modeling, ASIC (application specific integrated circuit) design flow
and verified using a FPGA (field programmable gate array) board
and MATLAB analysis.
Abstract: Based on the sources- smoothed rank profile (SRP) and modified minimum description length (MMDL) principle, a method for estimation of the source coherency structure (SCS) and the number of wideband sources is proposed in this paper. Instead of focusing, we first use a spatial smoothing technique to pre-process the array covariance matrix of each frequency for de-correlating the sources and then use smoothed rank profile to determine the SCS and the number of wideband sources. We demonstrate the availability of the method by numerical simulations.
Abstract: This paper describes the development of a fully
automated measurement software for antenna radiation pattern
measurements in a Compact Antenna Test Range (CATR). The
CATR has a frequency range from 2-40 GHz and the measurement
hardware includes a Network Analyzer for transmitting and
Receiving the microwave signal and a Positioner controller to control
the motion of the Styrofoam column. The measurement process
includes Calibration of CATR with a Standard Gain Horn (SGH)
antenna followed by Gain versus angle measurement of the Antenna
under test (AUT). The software is designed to control a variety of
microwave transmitter / receiver and two axis Positioner controllers
through the standard General Purpose interface bus (GPIB) interface.
Addition of new Network Analyzers is supported through a slight
modification of hardware control module. Time-domain gating is
implemented to remove the unwanted signals and get the isolated
response of AUT. The gated response of the AUT is compared with
the calibration data in the frequency domain to obtain the desired
results. The data acquisition and processing is implemented in
Agilent VEE and Matlab. A variety of experimental measurements
with SGH antennas were performed to validate the accuracy of
software. A comparison of results with existing commercial
softwares is presented and the measured results are found to be
within .2 dBm.
Abstract: In this work we present a solution for DAGC (Digital
Automatic Gain Control) in WLAN receivers compatible to IEEE 802.11a/g standard. Those standards define communication in 5/2.4
GHz band using Orthogonal Frequency Division Multiplexing OFDM modulation scheme. WLAN Transceiver that we have used
enables gain control over Low Noise Amplifier (LNA) and a
Variable Gain Amplifier (VGA). The control over those signals is
performed in our digital baseband processor using dedicated hardware block DAGC. DAGC in this process is used to automatically control the VGA and LNA in order to achieve better
signal-to-noise ratio, decrease FER (Frame Error Rate) and hold the
average power of the baseband signal close to the desired set point.
DAGC function in baseband processor is done in few steps: measuring power levels of baseband samples of an RF signal,accumulating the differences between the measured power level and
actual gain setting, adjusting a gain factor of the accumulation, and
applying the adjusted gain factor the baseband values. Based on the measurement results of RSSI signal dependence to input power we have concluded that this digital AGC can be implemented applying
the simple linearization of the RSSI. This solution is very simple but also effective and reduces complexity and power consumption of the
DAGC. This DAGC is implemented and tested both in FPGA and in ASIC as a part of our WLAN baseband processor. Finally, we have integrated this circuit in a compact WLAN PCMCIA board based on MAC and baseband ASIC chips designed from us.