Abstract: Discharges in hydrogen, ignited by wire explosion, with current amplitude up to 1.5 MA were investigated. Channel diameter oscillations were observed on the photostreaks. Voltage and current curves correlated with the photostreaks. At initial gas pressure of 5-35 MPa the oscillation period was proportional to square root of atomic number of the initiating wire material. These oscillations were associated with aligned magnetic and gas-kinetic pressures. At initial pressure of 80-160 MPa acoustic pressure fluctuations on the discharge chamber wall were increased up to 150 MPa and there were the growth of voltage fluctuations on the discharge gap up to 3 kV simultaneously with it. In some experiments it was observed abrupt increase in the oscillation amplitude, which can be caused by the resonance of the acoustic oscillations in discharge chamber volume and the oscillations connected with alignment of the gaskinetic pressure and the magnetic pressure, as far as frequencies of these oscillations are close to each other in accordance with the estimates and the experimental data. Resonance of different type oscillations can produce energy density increasing in the discharge channel. Thus, the appropriate initial conditions in the experiment allow to increase the energy density in the discharge channel
Abstract: This paper aims to give a full study of the dynamic
behavior of a mono-phase active power filter. First, the principle of
the parallel active power filter will be introduced. Then, a
dimensioning procedure for all its components will be explained in
detail, such as the input filter, the current and voltage controllers.
This active power filter is simulated using OrCAD program showing
the validity of the theoretical study.
Abstract: Since large power transformers are the most
expensive and strategically important components of any power
generator and transmission system, their reliability is crucially
important for the energy system operation. Also, Circuit breakers are
very important elements in the power transmission line so monitoring
the events gives a knowledgebase to determine time to the next
maintenance. This paper deals with the introduction of the
comparative method of the state estimation of transformers and
Circuit breakers using continuous monitoring of voltage, current.
This paper gives details a new method based on wavelet to apparatus
insulation monitoring. In this paper to insulation monitoring of
transformer, a new method based on wavelet transformation and
neutral point analysis is proposed. Using the EMTP tools, fault in
transformer winding and the detailed transformer winding model
were simulated. The current of neutral point of winding was analyzed
by wavelet transformation. It is shown that the neutral current of the
transformer winding has useful information about fault in insulation
of the transformer.
Abstract: This paper discusses a new, systematic approach to
the synthesis of a NP-hard class of non-regenerative Boolean
networks, described by FON[FOFF]={mi}[{Mi}], where for every
mj[Mj]∈{mi}[{Mi}], there exists another mk[Mk]∈{mi}[{Mi}], such
that their Hamming distance HD(mj, mk)=HD(Mj, Mk)=O(n), (where
'n' represents the number of distinct primary inputs). The method
automatically ensures exact minimization for certain important selfdual
functions with 2n-1 points in its one-set. The elements meant for
grouping are determined from a newly proposed weighted incidence
matrix. Then the binary value corresponding to the candidate pair is
correlated with the proposed binary value matrix to enable direct
synthesis. We recommend algebraic factorization operations as a post
processing step to enable reduction in literal count. The algorithm
can be implemented in any high level language and achieves best
cost optimization for the problem dealt with, irrespective of the
number of inputs. For other cases, the method is iterated to
subsequently reduce it to a problem of O(n-1), O(n-2),.... and then
solved. In addition, it leads to optimal results for problems exhibiting
higher degree of adjacency, with a different interpretation of the
heuristic, and the results are comparable with other methods.
In terms of literal cost, at the technology independent stage, the
circuits synthesized using our algorithm enabled net savings over
AOI (AND-OR-Invert) logic, AND-EXOR logic (EXOR Sum-of-
Products or ESOP forms) and AND-OR-EXOR logic by 45.57%,
41.78% and 41.78% respectively for the various problems.
Circuit level simulations were performed for a wide variety of
case studies at 3.3V and 2.5V supply to validate the performance of
the proposed method and the quality of the resulting synthesized
circuits at two different voltage corners. Power estimation was
carried out for a 0.35micron TSMC CMOS process technology. In
comparison with AOI logic, the proposed method enabled mean
savings in power by 42.46%. With respect to AND-EXOR logic, the
proposed method yielded power savings to the tune of 31.88%, while
in comparison with AND-OR-EXOR level networks; average power
savings of 33.23% was obtained.
Abstract: A universal current-mode biquad is described which
represents an economical variant of well-known KHN (Kerwin,
Huelsman, Newcomb) voltage-mode filter. The circuit consists of
two multiple-output OTAs and of two grounded capacitors. Utilizing
simple splitter of the input current and a pair of jumpers, all the basic
2nd-order transfer functions can be implemented. The principle is
verified by Spice simulation on the level of a CMOS structure of
OTAs.
Abstract: The system is made with main distributed components:
First Level: Industrial Computers placed in Control Room (monitors thermal and electrical processes based on the data provided by the second level); Second Level: PLCs which collects data from process and transmits information on the first level; also takes commands from this level which are further, passed to execution elements from third
level; Third Level: field elements consisting in 3 categories: data collecting elements; data transfer elements from the third level to the second; execution elements which take commands from the second
level PLCs and executes them after which transmits the confirmation of execution to them. The purpose of the automatic functioning is the optimization of the co-generative electrical energy commissioning in the national
energy system and the commissioning of thermal energy to the consumers.
The integrated system treats the functioning of all the equipments and devices as a whole: Gas Turbine Units (GTU); MT 20kV Medium Voltage Station (MVS); 0,4 kV Low Voltage Station (LVS); Main Hot Water Boilers (MHW); Auxiliary Hot Water Boilers (AHW); Gas Compressor Unit (GCU); Thermal Agent Circulation
Pumping Unit (TPU); Water Treating Station (WTS).
Abstract: In this paper we propose a novel RF LDMOS structure which employs a thin strained silicon layer at the top of the channel and the N-Drift region. The strain is induced by a relaxed Si0.8 Ge0.2 layer which is on top of a compositionally graded SiGe buffer. We explain the underlying physics of the device and compare the proposed device with a conventional LDMOS in terms of energy band diagram and carrier concentration. Numerical simulations of the proposed strained silicon laterally diffused MOS using a 2 dimensional device simulator indicate improvements in saturation and linear transconductance, current drivability, cut off frequency and on resistance. These improvements are however accompanied with a suppression in the break down voltage.
Abstract: Nowadays, quasi-continuous wave diode lasers are
used in a widespread variety of applications. Temperature effects in
these lasers can strongly influence their performance. In this paper,
the effects of temperature have been experimentally investigated on
different features of a 60W-QCW diode laser. The obtained results
indicate that the conversion efficiency and operation voltage of diode
laser decrease with the augmentation of the working temperature
associated with a redshift in the laser peak wavelength. Experimental
results show the emission peak wavelength of laser shifts 0.26 nm
and the conversion efficiency decreases 1.76 % with the increase of
temperature from 40 to 50 ̊C. Present study also shows the slope
efficiency decreases gradually at low temperatures and rapidly at
higher temperatures. Regarding the close dependence of the
mentioned parameters to the operating temperature, it is of great
importance to carefully control the working temperature of diode
laser, particularly for medical applications.
Abstract: In this paper, the test purpose will be to assess
whether or not the accelerated model proposed by Eyring will be able
to translate results for the shape and scale parameters of an
underlying Weibull model, obtained under two accelerating using
conditions, to expected normal using condition results for these
parameters. The product being analyzed is a new type of insulate
fluid, and the accelerating factor is the voltage stresses applied to the
fluid at two different levels (30KV and 40KV). The normal operating
voltage is 25KV. In this case, it was possible to test the insulate fluid
at normal voltage using condition. Both results for the two
parameters of the Weibull model, obtained under normal using
condition and translated from accelerated using conditions to normal
conditions, will be compared to each other to assess the accuracy of
the Eyring model when the accelerating factor is only the voltage
stress.
Abstract: In this paper, the computation of the electrical field distribution around AC high-voltage lines is demonstrated. The advantages and disadvantages of two different methods are described to evaluate the electrical field quantity. The first method is a seminumerical method using the laws of electrostatic techniques to simulate the two-dimensional electric field under the high-voltage overhead line. The second method which will be discussed is the finite element method (FEM) using specific boundary conditions to compute the two- dimensional electric field distributions in an efficient way.
Abstract: This paper presents the experimental results on effect of applied voltage stress frequency to the occurrence of electrical treeing in 22 kV cross linked polyethylene (XLPE) insulated cable.Hallow disk of XLPE insulating material with thickness 5 mm taken from unused high voltage cable was used as the specimen in this study. Stainless steel needle was inserted gradually into the specimen to give a tip to earth plane electrode separation of 2.50.2 mm at elevated temperature 105-110°C. The specimen was then annealed for 5 minute to minimize any mechanical stress build up around the needle-plane region before it was cooled down to room temperature. Each specimen were subjected to the same applied voltage stress level at 8 kV AC rms, with various frequency, 50, 100, 500, 1000 and 2000 Hz. Initiation time, propagation speed and pattern of electrical treeing were examined in order to study the effect of applied voltage stress frequency. By the experimental results, initial time of visible treeing decreases with increasing in applied voltage frequency. Also, obviously, propagation speed of electrical treeing increases with increasing in applied voltage frequency.Furthermore, two types of electrical treeing, bush-like and branch-like treeing were observed.The experimental results confirmed the effect of voltage stress frequency as well.
Abstract: This paper presents features that characterize power
quality disturbances from recorded voltage waveforms using wavelet
transform. The discrete wavelet transform has been used to detect
and analyze power quality disturbances. The disturbances of interest
include sag, swell, outage and transient. A power system network has
been simulated by Electromagnetic Transients Program. Voltage
waveforms at strategic points have been obtained for analysis, which
includes different power quality disturbances. Then wavelet has been
chosen to perform feature extraction. The outputs of the feature
extraction are the wavelet coefficients representing the power quality
disturbance signal. Wavelet coefficients at different levels reveal the
time localizing information about the variation of the signal.
Abstract: The purpose of this paper is to improve electromagnetic characteristics on grounding grid by applying the conductive concrete. The conductive concrete in this study is under an extra high voltage (EHV, 345kV) system located in a high-tech industrial park or science park. Instead of surrounding soil of grounding grid, the application of conductive concrete can reduce equipment damage and body damage caused by switching surges. The focus of the two cases on the EHV distribution system in a high-tech industrial park is presented to analyze four soil material styles. By comparing several soil material styles, the study results have shown that the conductive concrete can effectively reduce the negative damages caused by electromagnetic transient. The adoption of the style of grounding grid located 1.0 (m) underground and conductive concrete located from the ground surface to 1.25 (m) underground can obviously improve the electromagnetic characteristics so as to advance protective efficiency.
Abstract: In this paper we propose the study of a centrifugal pump control system driven by a three-phase induction motor, which is supplied by a PhotoVoltaic PV generator. The system includes solar panel, a DC / DC converter equipped with its MPPT control, a voltage inverter to three-phase Pulse Width Modulation - PWM and a centrifugal pump driven by a three phase induction motor. In order to control the flow of the centrifugal pump, a Direct Torque Control - DTC of the induction machine is used. To illustrate the performances of the control, simulation results are carried out using Matlab/Simulink.
Abstract: This study describes analysis of tower grounding
resistance effected the back flashover voltage across insulator string
in a transmission system. This paper studies the 500 kV transmission
lines from Mae Moh, Lampang to Nong Chok, Bangkok, Thailand,
which is double circuit in the same steel tower with two overhead
ground wires. The factor of this study includes magnitude of
lightning stroke, and front time of lightning stroke. Steel tower uses
multistory tower model. The assumption of studies based on the
return stroke current ranged 1-200 kA, front time of lightning stroke
between 1 μs to 3 μs. The simulations study the effect of varying
tower grounding resistance that affect the lightning current.
Simulation results are analyzed lightning over voltage that causes
back flashover at insulator strings. This study helps to know causes
of problems of back flashover the transmission line system, and also
be as a guideline solving the problem for 500 kV transmission line
systems, as well.
Abstract: Static synchronous compensator (STATCOM) is a shunt connected voltage source converter (VSC), which can affect rapid control of reactive flow in the transmission line by controlling the generated a.c. voltage. The main aim of the paper is to design a power system installed with a Static synchronous compensator (STATCOM) and demonstrates the application of the linearised Phillips-heffron model in analyzing the damping effect of the STATCOM to improve power system oscillation stability. The proposed PI controller is designed to coordinate two control inputs: Voltage of the injection bus and capacitor voltage of the STATCOM, to improve the Dynamic stability of a SMIB system .The power oscillations damping (POD) control and power system stabilizer (PSS) and their coordinated action with proposed controllers are tested. The simulation result shows that the proposed damping controllers provide satisfactory performance in terms of improvements of dynamic stability of the system.
Abstract: Worldwide many electrical equipment insulation
failures have been reported caused by switching operations, while
those equipments had previously passed all the standard tests and
complied with all quality requirements. The problem is mostly
associated with high-frequency overvoltages generated during
opening or closing of a switching device. The transients generated
during switching operations in a Gas Insulated Substation (GIS) are
associated with high frequency components in the order of few tens
of MHz.
The frequency spectrum of the VFTO generated in the 220/66 kV
Wadi-Hoff GIS is analyzed using Fast Fourier Transform technique.
The main frequency with high voltage amplitude due to the operation
of disconnector (DS5) is 5 to 10 MHz, with the highest amplitude at 9
MHz. The main frequency with high voltage amplitude due to the
operation of circuit breaker (CB5) is 1 to 25 MHz, with the highest
amplitude at 2 MHz.
Mitigating techniques damped the oscillating frequencies
effectively. The using of cable terminal reduced the frequency
oscillation effectively than that of OHTL terminal. The using of a
shunt capacitance results in vanishing the high frequency
components. Ferrite rings reduces the high frequency components
effectively especially in the range 2 to 7 MHz. The using of RC and
RL filters results in vanishing the high frequency components.
Abstract: Individually Network reconfiguration or Capacitor control
perform well in minimizing power loss and improving voltage
profile of the distribution system. But for heavy reactive power loads
network reconfiguration and for heavy active power loads capacitor
placement can not effectively reduce power loss and enhance
voltage profiles in the system. In this paper, an hybrid approach
that combine network reconfiguration and capacitor placement using
Harmony Search Algorithm (HSA) is proposed to minimize power
loss reduction and improve voltage profile. The proposed approach
is tested on standard IEEE 33 and 16 bus systems. Computational
results show that the proposed hybrid approach can minimize losses
more efficiently than Network reconfiguration or Capacitor control.
The results of proposed method are also compared with results
obtained by Simulated Annealing (SA). The proposed method has
outperformed in terms of the quality of solution compared to SA.
Abstract: This paper proposes a methodology for mitigating the occurrence of cascading failure in stressed power systems. The methodology is essentially based on predicting voltage instability in the power system using a voltage stability index and then devising a corrective action in order to increase the voltage stability margin. The paper starts with a brief description of the cascading failure mechanism which is probable root cause of severe blackouts. Then, the voltage instability indices are introduced in order to evaluate stability limit. The aim of the analysis is to assure that the coordination of protection, by adopting load shedding scheme, capable of enhancing performance of the system after the major location of instability is determined. Finally, the proposed method to generate instability prediction is introduced.
Abstract: The paper presents a detailed calculation of characteristic of five different topology permanent magnet machines for high performance traction including hybrid -electric vehicles using finite element analysis (FEA) method. These machines include V-shape single layer interior PM, W-shape single-layer interior PM, Segment interior PM and surface PM on the rotor and with distributed winding on the stator. The performance characteristics which include the back-emf voltage and its harmonic, magnet mass, iron loss and ripple torque are compared and analyzed. One of a 7.5kW IPM prototype was tested and verified finite-element analysis results. The aim of the paper is given some guidance and reference for machine designer which are interested in IPM machine selection for high performance traction application.