Abstract: In contrast to conventional generators, self-excited induction generators are found to be most suitable machines for wind energy conversion in remote and windy areas due to many advantages over grid connected machines. This papers presents a Self-Excited Induction Generator (SEIG) driven by wind turbine and supplying an induction motor which is coupled to a centrifugal pump. A method to describe the steady state performance based on nodal analysis is presented. Therefore the advanced knowledge of the minimum excitation capacitor value is required. The effects of variation of excitation capacitance on system and rotor speed under different loading conditions have been analyzed and considered to optimize induction motor pump performances.
Abstract: This paper presents a robust proportionalderivative
(PD) based cerebellar model articulation
controller (CMAC) for vertical take-off and landing flight
control systems. Successful on-line training and recalling
process of CMAC accompanying the PD controller is
developed. The advantage of the proposed method is mainly
the robust tracking performance against aerodynamic
parametric variation and external wind gust. The
effectiveness of the proposed algorithm is validated through
the application of a vertical takeoff and landing aircraft
control system.
Abstract: In this article the influence of higher frequency effects
in addition to a special damper design on the electrical behavior of a
synchronous generator main exciter machine is investigated. On the
one hand these machines are often highly stressed by harmonics from
the bridge rectifier thus facing additional eddy current losses. On the
other hand the switching may cause the excitation of dangerous
voltage peaks in resonant circuits formed by the diodes of the
rectifier and the commutation reactance of the machine. Therefore
modern rotating exciters are treated like synchronous generators
usually modeled with a second order equivalent circuit. Hence the
well known Standstill Frequency Response Test (SSFR) method is
applied to a test machine in order to determine parameters for the
simulation. With these results it is clearly shown that higher
frequencies have a strong impact on the conventional equivalent
circuit model. Because of increasing field displacement effects in the
stranded armature winding the sub-transient reactance is even smaller
than the armature leakage at high frequencies. As a matter of fact this
prevents the algorithm to find an equivalent scheme. This issue is
finally solved using Laplace transfer functions fully describing the
transient behavior at the model ports.
Abstract: In this report we present a rule-based approach to
detect anomalous telephone calls. The method described here uses
subscriber usage CDR (call detail record) data sampled over two
observation periods: study period and test period. The study period
contains call records of customers- non-anomalous behaviour.
Customers are first grouped according to their similar usage
behaviour (like, average number of local calls per week, etc). For
customers in each group, we develop a probabilistic model to describe
their usage. Next, we use maximum likelihood estimation (MLE) to
estimate the parameters of the calling behaviour. Then we determine
thresholds by calculating acceptable change within a group. MLE is
used on the data in the test period to estimate the parameters of the
calling behaviour. These parameters are compared against thresholds.
Any deviation beyond the threshold is used to raise an alarm. This
method has the advantage of identifying local anomalies as compared
to techniques which identify global anomalies. The method is tested
for 90 days of study data and 10 days of test data of telecom
customers. For medium to large deviations in the data in test window,
the method is able to identify 90% of anomalous usage with less than
1% false alarm rate.
Abstract: This paper presents a new method for estimating the mean curve of impulse voltage waveforms that are recorded during impulse tests. In practice, these waveforms are distorted by noise, oscillations and overshoot. The problem is formulated as an estimation problem. Estimation of the current signal parameters is achieved using a fast and accurate technique. The method is based on discrete dynamic filtering algorithm (DDF). The main advantage of the proposed technique is its ability in producing the estimates in a very short time and at a very high degree of accuracy. The algorithm uses sets of digital samples of the recorded impulse waveform. The proposed technique has been tested using simulated data of practical waveforms. Effects of number of samples and data window size are studied. Results are reported and discussed.
Abstract: As an effort to promote wind power industry in Korea,
Korea South-East Power Corporation has been developing 22MW
YeungHeung wind farm consisting of nine 2 to 3MW wind turbines
supplied by three manufacturers. To maximize its availability and
reliability and to solve the difficulty of operating three kinds of
SCADA systems, Korea Electric Power Corporation has been
developing a condition monitoring system integrated with control
functions. This paper presents the developed condition monitoring
system and its application to YeungHeung wind test bed, and the
design of its control functions.
Abstract: Mostly the real life signals are time varying in nature. For proper characterization of such signals, time-frequency representation is required. The STFT (short-time Fourier transform) is a classical tool used for this purpose. The limitation of the STFT is its fixed time-frequency resolution. Thus, an enhanced version of the STFT, which is based on the cross-level sampling, is devised. It can adapt the sampling frequency and the window function length by following the input signal local variations. Therefore, it provides an adaptive resolution time-frequency representation of the input. The computational complexity of the proposed STFT is deduced and compared to the classical one. The results show a significant gain of the computational efficiency and hence of the processing power. The processing error of the proposed technique is also discussed.
Abstract: This paper quantifies the impact of providing a shortterm
excess active power support of a variable speed wind turbine
(VSWT) and effect of super magnetic energy storage (SMES) unit on
frequency control, particularly temporary minimum frequency (TMF)
term. To demonstrate the effect of these factors on the power system
frequency, a three-area power system is considered as a test system.
Abstract: This paper proposes the method combining artificial neural network with particle swarm optimization (PSO) to implement the maximum power point tracking (MPPT) by controlling the rotor speed of the wind generator. With the measurements of wind speed, rotor speed of wind generator and output power, the artificial neural network can be trained and the wind speed can be estimated. The proposed control system in this paper provides a manner for searching the maximum output power of wind generator even under the conditions of varying wind speed and load impedance.
Abstract: The flow field over a flat roof model building has been numerically investigated in order to determine threedimensional CFD guidelines for the calculation of the turbulent flow over a structure immersed in an atmospheric boundary layer. To this purpose, a complete validation campaign has been performed through a systematic comparison of numerical simulations with wind tunnel experimental data. Wind tunnel measurements and numerical predictions have been compared for five different vertical positions, respectively from the upstream leading edge to the downstream bottom edge of the analyzed model. Flow field characteristics in the neighborhood of the building model have been numerically investigated, allowing a quantification of the capabilities of the CFD code to predict the flow separation and the extension of the recirculation regions. The proposed calculations have allowed the development of a preliminary procedure to be used as guidance in selecting the appropriate grid configuration and corresponding turbulence model for the prediction of the flow field over a three-dimensional roof architecture dominated by flow separation.
Abstract: The winding hot-spot temperature is one of the most
critical parameters that affect the useful life of the power
transformers. The winding hot-spot temperature can be calculated as
function of the top-oil temperature that can estimated by using the
ambient temperature and transformer loading measured data. This
paper proposes the estimation of the top-oil temperature by using a
method based on Least Squares Support Vector Machines approach.
The estimated top-oil temperature is compared with measured data of
a power transformer in operation. The results are also compared with
methods based on the IEEE Standard C57.91-1995/2000 and
Artificial Neural Networks. It is shown that the Least Squares
Support Vector Machines approach presents better performance than
the methods based in the IEEE Standard C57.91-1995/2000 and
artificial neural networks.
Abstract: This paper focuses on assessment of air pollution in Umm-Alhyman, Kuwait, which is located south to oil refineries, power station, oil field, and highways. The measurements were made over a period of four days in March and July in 2001, 2004, and 2008. The measured pollutants included methanated and nonmethanated hydrocarbons (MHC, NMHC), CO, CO2, SO2, NOX, O3, and PM10. Also, meteorological parameters were measured, which includes temperature, wind speed and direction, and solar radiation. Over the study period, data analysis showed increase in measured SO2, NOX and CO by factors of 1.2, 5.5 and 2, respectively. This is explained in terms of increase in industrial activities, motor vehicle density, and power generation. Predictions of the measured data were made by the ISC-AERMOD software package and by using the ISCST3 model option. Finally, comparison was made between measured data against international standards.
Abstract: This paper proposes a direct power control for
doubly-fed induction machine for variable speed wind power
generation. It provides decoupled regulation of the primary side
active and reactive power and it is suitable for both electric energy
generation and drive applications. In order to control the power
flowing between the stator of the DFIG and the network, a decoupled
control of active and reactive power is synthesized using PI
controllers.The obtained simulation results show the feasibility
and the effectiveness of the suggested method
Abstract: The householder RLS (HRLS) algorithm is an O(N2)
algorithm which recursively updates an arbitrary square-root of the
input data correlation matrix and naturally provides the LS weight
vector. A data dependent householder matrix is applied for such
an update. In this paper a recursive estimate of the eigenvalue
spread and misalignment of the algorithm is presented at a very low
computational cost. Misalignment is found to be highly sensitive to
the eigenvalue spread of input signals, output noise of the system and
exponential window. Simulation results show noticeable degradation
in the misalignment by increase in eigenvalue spread as well as
system-s output noise, while exponential window was kept constant.
Abstract: In this paper, a Dynamic Economic Dispatch (DED) model is developed for the system consisting of both thermal generators and wind turbines. The inclusion of a significant amount of wind energy into power systems has resulted in additional constraints on DED to accommodate the intermittent nature of the output. The probability of stochastic wind power based on the Weibull probability density function is included in the model as a constraint; A Here-and-Now Approach. The Environmental Protection Agency-s hourly emission target, which gives the maximum emission during the day, is used as a constraint to reduce the atmospheric pollution. A 69-bus test system with non-smooth cost function is used to illustrate the effectiveness of the proposed model compared with static economic dispatch model with including the wind power.
Abstract: Bond graph models of an electrical transformer including
the nonlinear saturation are presented. The transformer
using electrical and magnetic circuits are modelled. These models
determine the relation between self and mutual inductances, and
the leakage and magnetizing inductances of power transformers
with two windings using the properties of a bond graph. The
equivalence between electrical and magnetic variables is given.
The modelling and analysis using this methodology to three phase
power transformers can be extended.
Abstract: A boundary layer wind tunnel facility has been
adopted in order to conduct experimental measurements of the flow field around a model of the Panorama Giustinelli Building, Trieste
(Italy). Information on the main flow structures has been obtained by means of flow visualization techniques and has been compared to the
numerical predictions of the vortical structures spread on top of the roof, in order to investigate the optimal positioning for a vertical-axis
wind energy conversion system, registering a good agreement between experimental measurements and numerical predictions.
Abstract: The background estimation approach using a small
window median filter is presented on the bases of analyzing IR point
target, noise and clutter model. After simplifying the two-dimensional
filter, a simple method of adopting one-dimensional median filter is
illustrated to make estimations of background according to the
characteristics of IR scanning system. The adaptive threshold is used
to segment canceled image in the background. Experimental results
show that the algorithm achieved good performance and satisfy the
requirement of big size image-s real-time processing.
Abstract: Shear walls are used in most of the tall buildings for
carrying the lateral load. When openings for doors or windows are
necessary to be existed in the shear walls, a special type of the shear
walls is used called "coupled shear walls" which in some cases is
stiffened by specific beams and so, called "stiffened coupled shear
walls".
In this paper, a mathematical method for geometrically nonlinear
analysis of the stiffened coupled shear walls has been presented.
Then, a suitable formulation for determining the critical load of the
stiffened coupled shear walls under gravity force has been proposed.
The governing differential equations for equilibrium and deformation
of the stiffened coupled shear walls have been obtained by setting up
the equilibrium equations and the moment-curvature relationships for
each wall. Because of the complexity of the differential equation, the
energy method has been adopted for approximate solution of the
equations.
Abstract: wind catchers have been served as a cooling system, used to provide acceptable ventilation by means of renewable energy of wind. In the present study, the city of Yazd in arid climate is selected as case study. From the architecture point of view, learning about wind catchers in this study is done by means of field surveys. Research method for selection of the case is based on random form, and analytical method. Wind catcher typology and knowledge of relationship governing the wind catcher's architecture were those measures that are taken for the first time. 53 wind catchers were analyzed. The typology of the wind-catchers is done by the physical analyzing, patterns and common concepts as incorporated in them. How the architecture of wind catcher can influence their operations by analyzing thermal behavior are the archetypes of selected wind catchers. Calculating fluids dynamics science, fluent software and numerical analysis are used in this study as the most accurate analytical approach. The results obtained from these analyses show the formal specifications of wind catchers with optimum operation in Yazd. The knowledge obtained from the optimum model could be used for design and construction of wind catchers with more improved operation