Abstract: A boundary layer wind tunnel facility has been
adopted in order to conduct experimental measurements of the flow field around a model of the Panorama Giustinelli Building, Trieste
(Italy). Information on the main flow structures has been obtained by means of flow visualization techniques and has been compared to the
numerical predictions of the vortical structures spread on top of the roof, in order to investigate the optimal positioning for a vertical-axis
wind energy conversion system, registering a good agreement between experimental measurements and numerical predictions.
Abstract: The flow filed around a flatted-roof compound has
been investigated by means of 2D and 3D numerical simulations. A
constant wind velocity profile, based both on the maximum reference
wind speed in the building site (peak gust speed worked out for a 50-
year return period) and on the local roughness coefficient, has been
simulated in order to determine the wind-induced loads on top of the
roof. After determining the influence of the incoming wind directions
on the induced roof loads, a 2D analysis of the most severe load
condition has been performed, achieving a numerical quantification
of the expected wind-induced forces on the PV panels on top of the
roof.