Semi-Automated Tracking of Vibrissal Movements in Free-Moving Rodents Captured by High-Speed Videos

Quantitative analyses of whisker movements provide a means to study functional recovery and regeneration of mouse facial nerve after an injury. However, accurate tracking of the mouse whisker movement is challenging. Most methods for whisker tracking require manual intervention, e.g. fixing the head of the mouse during a study. Here we describe a semi-automated image processing method, which is applied to high-speed video recordings of free-moving mice to track the whisker movements. We first track the head movement of a mouse by delineating the lower head contour frame-by-frame that allows for detection of the location and orientation of the head. Then, a region of interest is identified for each frame; the subsequent application of a mask and the Hough transform detects the selected whiskers on each side of the head. Our approach is used to examine the functional recovery of damaged facial nerves in mice over a course of 21 days.

Demographics Are Not Enough: Targeting and Segmentation of Anti-Obesity Campaigns in Mexico

Mass media campaigns against obesity are often designed to impact large audiences. This usually means that their audience is defined based on general demographic characteristics like age, gender, occupation etc., not taking into account psychographics like behavior, motivations, wants, etc. Using psychographics, as the base for the audience segmentation, is a common practice in case of successful campaigns, as it allows developing more relevant messages. It also serves a purpose of identifying key segments, those that generate the best return on investment. For a health campaign, that would be segments that have the best chance of being converted into healthy lifestyle at the lowest cost. This paper presents the limitations of the demographic targeting, based on the findings from the reception study of IMSS (Mexican Social Security Institute) antiobesity TV commercials and proposes mothers as the first level of segmentation, in the process of identifying the key segment for these campaigns.

The Nature of the Complicated Fabric Textures: How to Represent in Primary Visual Cortex

Fabric textures are very common in our daily life. However, the representation of fabric textures has never been explored from neuroscience view. Theoretical studies suggest that primary visual cortex (V1) uses a sparse code to efficiently represent natural images. However, how the simple cells in V1 encode the artificial textures is still a mystery. So, here we will take fabric texture as stimulus to study the response of independent component analysis that is established to model the receptive field of simple cells in V1. We choose 140 types of fabrics to get the classical fabric textures as materials. Experiment results indicate that the receptive fields of simple cells have obvious selectivity in orientation, frequency and phase when drifting gratings are used to determine their tuning properties. Additionally, the distribution of optimal orientation and frequency shows that the patch size selected from each original fabric image has a significant effect on the frequency selectivity.

(Anti)Depressant Effects of Non-Steroidal Antiinflammatory Drugs in Mice

Purpose: The study aimed to assess the depressant or antidepressant effects of several Nonsteroidal Anti-Inflammatory Drugs (NSAIDs) in mice: the selective cyclooxygenase-2 (COX-2) inhibitor meloxicam, and the non-selective COX-1 and COX-2 inhibitors lornoxicam, sodium metamizole, and ketorolac. The current literature data regarding such effects of these agents are scarce. Materials and methods: The study was carried out on NMRI mice weighing 20-35 g, kept in a standard laboratory environment. The study was approved by the Ethics Committee of the University of Medicine and Pharmacy „Carol Davila”, Bucharest. The study agents were injected intraperitoneally, 10 mL/kg body weight (bw) 1 hour before the assessment of the locomotor activity by cage testing (n=10 mice/ group) and 2 hours before the forced swimming tests (n=15). The study agents were dissolved in normal saline (meloxicam, sodium metamizole), ethanol 11.8% v/v in normal saline (ketorolac), or water (lornoxicam), respectively. Negative and positive control agents were also given (amitryptilline in the forced swimming test). The cage floor used in the locomotor activity assessment was divided into 20 equal 10 cm squares. The forced swimming test involved partial immersion of the mice in cylinders (15/9cm height/diameter) filled with water (10 cm depth at 28C), where they were left for 6 minutes. The cage endpoint used in the locomotor activity assessment was the number of treaded squares. Four endpoints were used in the forced swimming test (immobility latency for the entire 6 minutes, and immobility, swimming, and climbing scores for the final 4 minutes of the swimming session), recorded by an observer that was „blinded” to the experimental design. The statistical analysis used the Levene test for variance homogeneity, ANOVA and post-hoc analysis as appropriate, Tukey or Tamhane tests. Results: No statistically significant increase or decrease in the number of treaded squares was seen in the locomotor activity assessment of any mice group. In the forced swimming test, amitryptilline showed an antidepressant effect in each experiment, at the 10 mg/kg bw dosage. Sodium metamizole was depressant at 100 mg/kg bw (increased the immobility score, p=0.049, Tamhane test), but not in lower dosages as well (25 and 50 mg/kg bw). Ketorolac showed an antidepressant effect at the intermediate dosage of 5 mg/kg bw, but not so in the dosages of 2.5 and 10 mg/kg bw, respectively (increased the swimming score, p=0.012, Tamhane test). Meloxicam and lornoxicam did not alter the forced swimming endpoints at any dosage level. Discussion: 1) Certain NSAIDs caused changes in the forced swimming patterns without interfering with locomotion. 2) Sodium metamizole showed a depressant effect, whereas ketorolac proved antidepressant. Conclusion: NSAID-induced mood changes are not class effects of these agents and apparently are independent of the type of inhibited cyclooxygenase (COX-1 or COX-2). Disclosure: This paper was co-financed from the European Social Fund, through the Sectorial Operational Programme Human Resources Development 2007-2013, project number POSDRU /159 /1.5 /S /138907 "Excellence in scientific interdisciplinary research, doctoral and postdoctoral, in the economic, social and medical fields -EXCELIS", coordinator The Bucharest University of Economic Studies.

Development and Validation of the Response to Stressful Situations Scale in the General Population

The aim of the current study was to develop and validate a Response to Stressful Situations Scale (RSSS) for the Portuguese population. This scale assesses the degree of stress experienced in scenarios that can constitute positive, negative and more neutral stressors, and also describes the physiological, emotional and behavioral reactions to those events according to their intensity. These scenarios include typical stressor scenarios relevant to patients with schizophrenia, which are currently absent from most scales, assessing specific risks that these stressors may bring on subjects, which may prove useful in non-clinical and clinical populations (i.e. Patients with mood or anxiety disorders, schizophrenia). Results from Principal Components Analysis and Confirmatory Factor Analysis of two adult samples from general population allowed to confirm a three-factor model with good fit indices: χ2 (144)= 370.211, p = 0.000; GFI = 0.928; CFI = 0.927; TLI = 0.914, RMSEA = 0.055, P(rmsea ≤0.005) = .096; PCFI = .781. Further data analysis of the scale revealed that RSSS is an adequate assessment tool of stress response in adults to be used in further research and clinical settings, with good psychometric characteristics, adequate divergent and convergent validity, good temporal stability and high internal consistency.

Effect of Operating Conditions on Forward Osmosis for Nutrient Rejection Using Magnesium Chloride as a Draw Solution

Advanced treatments such as forward osmosis (FO) can be used to separate or reject nutrients from secondary treated effluents. Forward osmosis uses the chemical potential across the membrane, which is the osmotic pressure gradient, to induce water to flow through the membrane from a feed solution (FS) into a draw solution (DS). The performance of FO is affected by the membrane characteristics, composition of the FS and DS, and operating conditions. The aim of this study was to investigate the optimum velocity and temperature for nutrient rejection and water flux performance in FO treatments. MgCl2 was used as the DS in the FO process. The results showed that higher cross flow velocities yielded higher water fluxes. High rejection of nutrients was achieved by using a moderate cross flow velocity at 0.25 m/s. Nutrient rejection was insensitive to temperature variation, whereas water flux was significantly impacted by it. A temperature of 25°C was found to be good for nutrient rejection.

Reduction of Impulsive Noise in OFDM System Using Adaptive Algorithm

The Orthogonal Frequency Division Multiplexing (OFDM) with high data rate, high spectral efficiency and its ability to mitigate the effects of multipath makes them most suitable in wireless application. Impulsive noise distorts the OFDM transmission and therefore methods must be investigated to suppress this noise. In this paper, a State Space Recursive Least Square (SSRLS) algorithm based adaptive impulsive noise suppressor for OFDM communication system is proposed. And a comparison with another adaptive algorithm is conducted. The state space model-dependent recursive parameters of proposed scheme enables to achieve steady state mean squared error (MSE), low bit error rate (BER), and faster convergence than that of some of existing algorithm.

Oily Sludge Bioremediation Pilot Plant Project, Nigeria

Brass terminal, one of the several crude oil and petroleum products storage/handling facilities in the Niger Delta was built in the 1980s. Activities at this site, over the years, released crude oil into this 3 m-deep, 1500 m-long canal lying adjacent to the terminal with oil floating on it and its sediment heavily polluted. To ensure effective clean-up, three major activities were planned: site characterization, bioremediation pilot plant construction and testing and full-scale bioremediation of contaminated sediment / bank soil by land farming. The canal was delineated into 12 lots and each characterized, with reference to the floating oily phase, contaminated sediment and canal bank soil. As a result of site characterization, a pilot plant for on-site bioremediation was designed and a treatment basin constructed for carrying out pilot bioremediation test. Following a designed sampling protocol, samples from this pilot plant were collected for analysis at two laboratories as a quality assurance / quality control check. Results showed that Brass Canal upstream is contaminated with dark, thick and viscous oily film with characteristic hydrocarbon smell while downstream, thin oily film interspersed with water was observed. Sediments were observed to be dark with mixture of brownish sandy soil with TPH ranging from 17,800 mg/kg in Lot 1 to 88,500 mg/kg in Lot 12 samples. Brass Canal bank soil was observed to be sandy from ground surface to 3m, below ground surface (bgs) it was silty-sandy and brownish while subsurface soil (4-10m bgs) was sandy-clayey and whitish/grayish with typical hydrocarbon smell. Preliminary results obtained so far have been very promising but were proprietary. This project is considered, to the best of technical literature knowledge, the first large-scale on-site bioremediation project in the Niger Delta region, Nigeria.

Spatio-temporal Variations in Heavy Metal Concentrations in Sediment of Qua Iboe River Estuary, Nigeria

The concentrations of heavy metals in sediments of Qua Iboe River Estuary (QIRE) were monitored at four different sampling locations in wet and dry seasons. A preliminary survey to determine the four sampling stations along the river continuum showed that the area spanned between

A Smart Monitoring System for Preventing Gas Risks in Indoor

In this paper, we propose a system for preventing gas risks through the use of wireless communication modules and intelligent gas safety appliances. Our system configuration consists of an automatic extinguishing system, detectors, a wall-pad, and a microcomputer controlled micom gas meter to monitor gas flow and pressure as well as the occurrence of earthquakes. The automatic fire extinguishing system checks for both combustible gaseous leaks and monitors the environmental temperature, while the detector array measures smoke and CO gas concentrations. Depending on detected conditions, the micom gas meter cuts off an inner valve and generates a warning, the automatic fire-extinguishing system cuts off an external valve and sprays extinguishing materials, or the sensors generate signals and take further action when smoke or CO are detected. Information on intelligent measures taken by the gas safety appliances and sensors are transmitted to the wall-pad, which in turn relays this as real time data to a server that can be monitored via an external network (BcN) connection to a web or mobile application for the management of gas safety. To validate this smart-home gas management system, we field-tested its suitability for use in Korean apartments under several scenarios.

Characteristic Study on Conventional and Soliton Based Transmission System

Here, we study the characteristic feature of conventional (ON-OFF keying) and soliton based transmission system. We consider 20Gbps transmission system implemented with Conventional Single Mode Fiber (C-SMF) to examine the role of Gaussian pulse which is the characteristic of conventional propagation and Hyperbolic-secant pulse which is the characteristic of soliton propagation in it. We note the influence of these pulses with respect to different dispersion lengths and soliton period in conventional and soliton system respectively and evaluate the system performance in terms of Quality factor. From the analysis, we could prove that the soliton pulse has the consistent performance even for long distance without dispersion compensation than the conventional system as it is robust to dispersion. For the length of transmission of 200Km, soliton system yielded Q of 33.958 while the conventional system totally exhausted with Q=0.

The Extraction and Stripping of Hg (II) from Produced Water via Hollow Fiber Contactor

The separation of Hg (II) from produced water by hollow fiber contactors (HFC) was investigation. This system included of two hollow fiber modules in the series connecting. The first module used for the extraction reaction and the second module for stripping reaction. Aliquat336 extractant was fed from the organic reservoirs into the shell side of the first hollow fiber module and continuous to the shell side of the second module. The organic liquid was continuously feed recirculate and back to the reservoirs. The feed solution was pumped into the lumen (tube side) of the first hollow fiber module. Simultaneously, the stripping solution was pumped in the same way in tube side of the second module. The feed and stripping solution was fed which had a countercurrent flow. Samples were kept in the outlet of feed and stripping solution at 1 hour and characterized concentration of Hg (II) by Inductively Couple Plasma Atomic Emission Spectroscopy (ICP-AES). Feed solution was produced water from natural gulf of Thailand. The extractant was Aliquat336 dissolved in kerosene diluent. Stripping solution used was nitric acid (HNO3) and thiourea (NH2CSNH2). The effect of carrier concentration and type of stripping solution were investigated. Results showed that the best condition were 10 % (v/v) Aliquat336 and 1.0 M NH2CSNH2. At the optimum condition, the extraction and stripping of Hg (II) were 98% and 44.2%, respectively.

Time/Temperature-Dependent Finite Element Model of Laminated Glass Beams

The polymer foil used for manufacturing of laminated glass members behaves in a viscoelastic manner with temperature dependance. This contribution aims at incorporating the time/temperature-dependent behavior of interlayer to our earlier elastic finite element model for laminated glass beams. The model is based on a refined beam theory: each layer behaves according to the finite-strain shear deformable formulation by Reissner and the adjacent layers are connected via the Lagrange multipliers ensuring the inter-layer compatibility of a laminated unit. The time/temperature-dependent behavior of the interlayer is accounted for by the generalized Maxwell model and by the time-temperature superposition principle due to the Williams, Landel, and Ferry. The resulting system is solved by the Newton method with consistent linearization and the viscoelastic response is determined incrementally by the exponential algorithm. By comparing the model predictions against available experimental data, we demonstrate that the proposed formulation is reliable and accurately reproduces the behavior of the laminated glass units.

Choosing between the Regression Correlation, the Rank Correlation, and the Correlation Curve

This paper presents a rank correlation curve. The traditional correlation coefficient is valid for both continuous variables and for integer variables using rank statistics. Since the correlation coefficient has already been established in rank statistics by Spearman, such a calculation can be extended to the correlation curve. This paper presents two survey questions. The survey collected non-continuous variables. We will show weak to moderate correlation. Obviously, one question has a negative effect on the other. A review of the qualitative literature can answer which question and why. The rank correlation curve shows which collection of responses has a positive slope and which collection of responses has a negative slope. Such information is unavailable from the flat, ”first-glance” correlation statistics.

The Impact of the Information Technologies on the Accounting Department of the Romanian Companies

The need to use high volumes of data and the high competition are only two reasons which make necessary the use of information technologies. The objective of our research is to establish the impact of information technologies on the accounting department of the Romanian companies. In order to achieve it, starting from the literature review we made an empirical research based on a questionnaire. We investigated the types of technologies used, the reasons which led to the implementation of certain technologies, the benefits brought by the use of the information technologies, the difficulties brought by the implementation and the future effects of the applications. The conclusions show that there is an evolution in the degree of implementation of the information technologies in the Romanian companies, compared with the results of other studies conducted a few years before.

Radiobiological Model in Radiotherapy Planning for Prostate Cancer Treatment

Quantitative radiobiological models can be used to assess the optimum clinical outcome from sophisticated therapeutic modalities by calculating tumor control probability (TCP) and normal tissue complication probability (NTCP). In this study two 3D-CRT and an IMRT treatment plans were developed with an initial prescription dose of 60 Gy in 2 Gy/fraction to prostate. Sensitivity of TCP and Complication free tumor control probability (P+) to the different values of α/β ratio was investigated for various prescription doses planned to be delivered in either a fixed number of fractions (I) or in a fixed dose per fraction (II) in each of the three different treatment plans. High dose/fraction and high α/β value result in comparatively smaller P+ and IMRT plans resulted in the highest P+, mainly due to the decrease in NTCP. If α/β is lower than expected, better tumor control can be achieved by increasing dose/fraction but decreasing the number of fractions.

Antibacterial Activity of Some Medicinal Plant Extracts

Medicinal plants are now gaining attractiveness in treatment of bacterial infections and food preservation. The objective of this study was to assess antibacterial activity of some medicinal plants on pathogenic bacteria. Screening of antibacterial activity of aqueous and methanol extracts of some plants: Jojoba, Ginger, Sage, Thyme and Clove against Bacillus cereus, Salmonella typhimurium, Staphylococcus aureus, Clostridium perfringens and Escherichia coli were investigated. Antibacterial activity was performed by agar diffusion and disc diffusion method. Jatropha, Jojoba, Clove and Ginger extracts showed notable bacterial activity in the first screening step then selected to be tested against Bacillus cereus (Gram+), Staphylococcus aureus (Gram+) and Salmonella typhimurium (Gram−) and their effect was compared using antibiotics as control. Screening results showed potential antibacterial activity of the tested plant extracts against the screened bacterial strains. It was found that methanol extracts exhibited higher antibacterial activity than aqueous extracts. Methanol extract of Jatropha showed the highest inhibition zone against Staphylococcus aureus (Gram+) with 24.00 mm diameter, compared to the other plant extracts followed by clove. Meanwhile, the inhibition zones of methanol extracts of Jojoba and Ginger were the same (12mm).The Gram-positive bacteria were found to be more sensitive to aqueous and methanol extracts than Gram-negative bacteria.

Design and Fabrication of an Array Microejector Driven by a Shear-Mode Piezoelectric Actuator

This paper reports a novel actuating design that uses the shear deformation of a piezoelectric actuator to deflect a bulge-diaphragm for driving an array microdroplet ejector. In essence, we employed a circular-shaped actuator poled radial direction with remnant polarization normal to the actuating electric field for inducing the piezoelectric shear effect. The array microdroplet ejector consists of a shear type piezoelectric actuator, a vibration plate, two chamber plates, two channel plates and a nozzle plate. The vibration, chamber and nozzle plate components are fabricated using nickel electroforming technology, whereas the channel plate is fabricated by etching of stainless steel. The diaphragm displacement was measured by the laser two-dimensional scanning vibrometer. The ejected droplets of the microejector were also observed via an optic visualization system.

Relevance of the Variation in the Angulation of Palatal Throat Form to the Orientation of the Occlusal Plane: A Cephalometric Study

The posterior reference for the ala tragal line is a cause of confusion, with different authors suggesting different locations as to the superior, middle or inferior part of the tragus. This study was conducted on 200 subjects to evaluate if any correlation exists between the variation of angulation of palatal throat form and the relative parallelism of occlusal plane to ala-tragal line at different tragal levels. A custom made Occlusal Plane Analyzer was used to check the parallelism between the ala-tragal line and occlusal plane. A lateral cephalogram was shot for each subject to measure the angulation of the palatal throat form. Fisher’s exact test was used to evaluate the correlation between the angulation of the palatal throat form and the relative parallelism of occlusal plane to the ala tragal line. Also, a classification was formulated for the palatal throat form, based on confidence interval. From the results of the study, the inferior part, middle part and superior part of the tragus were seen as the reference points in 49.5%, 32% and 18.5% of the subjects respectively. Class I palatal throat form (41degree-50 degree), Class II palatal throat form (below 41 degree) and Class III palatal throat form (above 50 degree) were seen in 42%, 43% and 15% of the subjects respectively. It was also concluded that there is no significant correlation between the variation in the angulations of the palatal throat form and the relative parallelism of occlusal plane to the ala-tragal line.

Influence of the Flow Rate Ratio in a Jet Pump on the Size of Air Bubbles

In wastewater treatment processes, aeration introduces air into a liquid. In these systems, air is introduced by different devices submerged in the wastewater. Smaller bubbles result in more bubble surface area per unit of volume and higher oxygen transfer efficiency. Jet pumps are devices that use air bubbles and are widely used in wastewater treatment processes. The principle of jet pumps is their ability to transfer energy of one fluid, called primary or motive, into a secondary fluid or gas. These pumps have no moving parts and are able to work in remote areas under extreme conditions. The objective of this work is to study experimentally the characteristics of the jet pump and the size of air bubbles in the laboratory water tank. The effect of flow rate ratio on pump performance is investigated in order to have a better understanding about pump behavior under various conditions, in order to determine the efficiency of receiving air bubbles different sizes. The experiments show that we should take care when increasing the flow rate ratio while seeking to decrease bubble size in the outlet flow. This study will help improve and extend the use of the jet pump in many practical applications.