Abstract: This paper discusses two observers, which are used
for the estimation of parameters of PMSM. Former one, reduced
order observer, which is used to estimate the inaccessible parameters
of PMSM. Later one, full order observer, which is used to estimate
all the parameters of PMSM even though some of the parameters are
directly available for measurement, so as to meet with the
insensitivity to the parameter variation. However, the state space
model contains some nonlinear terms i.e. the product of different
state variables. The asymptotic state observer, which approximately
reconstructs the state vector for linear systems without uncertainties,
was presented by Luenberger. In this work, a modified form of such
an observer is used by including a non-linear term involving the
speed. So, both the observers are designed in the framework of
nonlinear control; their stability and rate of convergence is discussed.
Abstract: Distance protection of transmission lines including advanced flexible AC transmission system (FACTS) devices has been a very challenging task. FACTS devices of interest in this paper are static synchronous series compensators (SSSC) and unified power flow controller (UPFC). In this paper, a new algorithm is proposed to detect and classify the fault and identify the fault position in a transmission line with respect to a FACTS device placed in the midpoint of the transmission line. Discrete wavelet transformation and wavelet entropy calculations are used to analyze during fault current and voltage signals of the compensated transmission line. The proposed algorithm is very simple and accurate in fault detection and classification. A variety of fault cases and simulation results are introduced to show the effectiveness of such algorithm.
Abstract: The impact of fixed speed squirrel cage type as well as
variable speed doubly fed induction generators (DFIG) on dynamic
performance of a multimachine power system has been investigated.
Detailed models of the various components have been presented and
the integration of asynchronous and synchronous generators has been
carried out through a rotor angle based transform. Simulation studies
carried out considering the conventional dynamic model of squirrel
cage asynchronous generators show that integration, as such, could
degrade to the AC system performance transiently. This article
proposes a frequency or power controller which can effectively
control the transients and restore normal operation of fixed speed
induction generator quickly. Comparison of simulation results
between classical cage and doubly-fed induction generators indicate
that the doubly fed induction machine is more adaptable to
multimachine AC system. Frequency controller installed in the DFIG
system can also improve its transient profile.
Abstract: Voltage flicker is a disturbance in electrical power
systems. The reason for this disturbance is mainly the large nonlinear
loads such as electric arc furnaces. Synchronous static
compensator (STATCOM) is considered as a proper technique to
mitigate the voltage flicker. Application of more suitable and precise
power electronic converter leads to a more precise performance of the
compensator. In this paper a three-level 12-pulse voltage source
inverter (VSI) with a 12-terminal transformer connected to the ac
system is studied and the obtained results are compared with the
performance of a STATCOM using a simple two-level VSI and an
optimal and more precise performance of the proposed scheme is
achieved.
Abstract: Wind power is among the most actively developing distributed generation (DG) technology. Majority of the wind power based DG technologies employ wind turbine induction generators (WTIG) instead of synchronous generators, for the technical advantages like: reduced size, increased robustness, lower cost, and increased electromechanical damping. However, dynamic changes of wind speed make the amount of active/reactive power injected/drawn to a WTIG embedded distribution network highly variable. This paper analyzes the effect of wind speed changes on the active and reactive power penetration to the wind energy embedded distribution network. Four types of wind speed changes namely; constant, linear change, gust change and random change of wind speed are considered in the analysis. The study is carried out by three-phase, non-linear, dynamic simulation of distribution system component models. Results obtained from the investigation are presented and discussed.
Abstract: In modern literary criticism the problem of genre is one of discussion. Genre is a phenomenon, located in the intersection of the synchronous and diachronic processes in the development of literature, and this is due to the complexity of its solutions. It defines the place of contact between literary works and literary process.
Abstract: In this paper, we propose a new algorithm for joint time-delay and direction-of-arrival (DOA) estimation, here called two-dimensional code acquisition, in an asynchronous directsequence code-division multiple-access (DS-CDMA) array system. This algorithm depends on eigenvector-eigenvalue decomposition of sample correlation matrix, and requires to know desired user-s training sequence. The performance of the algorithm is analyzed both analytically and numerically in uncorrelated and coherent multipath environment. Numerical examples show that the algorithm is robust with unknown number of coherent signals.
Abstract: The excellent suitability of the externally excited synchronous
machine (EESM) in automotive traction drive applications
is justified by its high efficiency over the whole operation range and
the high availability of materials. Usually, maximum efficiency is
obtained by modelling each single loss and minimizing the sum of all
losses. As a result, the quality of the optimization highly depends on
the precision of the model. Moreover, it requires accurate knowledge
of the saturation dependent machine inductances. Therefore, the
present contribution proposes a method to minimize the overall losses
of a salient pole EESM and its inverter in steady state operation based
on measurement data only. Since this method does not require any
manufacturer data, it is well suited for an automated measurement
data evaluation and inverter parametrization. The field oriented control
(FOC) of an EESM provides three current components resp. three
degrees of freedom (DOF). An analytic minimization of the copper
losses in the stator and the rotor (assuming constant inductances) is
performed and serves as a first approximation of how to choose the
optimal current reference values. After a numeric offline minimization
of the overall losses based on measurement data the results are
compared to a control strategy that satisfies cos (ϕ) = 1.
Abstract: This paper focuses on PSS/E modeling of wind farms
of Doubly-fed Induction Generator (DFIG) type and their impact on
issues of power system operation. Since Wind Turbine Generators
(WTG) don-t have the same characteristics as synchronous
generators, the appropriate modeling of wind farms is essential for
transmission system operators to analyze the best options of
transmission grid reinforcements as well as to evaluate the wind
power impact on reliability and security of supply. With the high
excepted penetration of wind power into the power system a
simultaneous loss of Wind Farm generation will put at risk power
system security and reliability. Therefore, the main wind grid code
requirements concern the fault ride through capability and frequency
operation range of wind turbines. In case of grid faults wind turbines
have to supply a definite reactive power depending on the
instantaneous voltage and to return quickly to normal operation.
Abstract: This paper provides the design steps of a robust Linear
Matrix Inequality (LMI) based iterative multivariable PID controller
whose duty is to drive a sample power system that comprises a
synchronous generator connected to a large network via a step-up
transformer and a transmission line. The generator is equipped with
two control-loops, namely, the speed/power (governor) and voltage
(exciter). Both loops are lumped in one where the error in the
terminal voltage and output active power represent the controller
inputs and the generator-exciter voltage and governor-valve position
represent its outputs. Multivariable PID is considered here because of
its wide use in the industry, simple structure and easy
implementation. It is also preferred in plants of higher order that
cannot be reduced to lower ones. To improve its robustness to
variation in the controlled variables, H∞-norm of the system transfer
function is used. To show the effectiveness of the controller, divers
tests, namely, step/tracking in the controlled variables, and variation
in plant parameters, are applied. A comparative study between the
proposed controller and a robust H∞ LMI-based output feedback is
given by its robustness to disturbance rejection. From the simulation
results, the iterative multivariable PID shows superiority.
Abstract: In this paper, investigation of subsynchronous
resonance (SSR) characteristics of a hybrid series compensated
system and the design of voltage controller for three level 24-pulse
Voltage Source Converter based Static Synchronous Series
Compensator (SSSC) is presented. Hybrid compensation consists of
series fixed capacitor and SSSC which is a active series FACTS
controller. The design of voltage controller for SSSC is based on
damping torque analysis, and Genetic Algorithm (GA) is adopted for
tuning the controller parameters. The SSR Characteristics of SSSC
with constant reactive voltage control modes has been investigated.
The results show that the constant reactive voltage control of SSSC
has the effect of reducing the electrical resonance frequency, which
detunes the SSR.The analysis of SSR with SSSC is carried out based
on frequency domain method, eigenvalue analysis and transient
simulation. While the eigenvalue and damping torque analysis are
based on D-Q model of SSSC, the transient simulation considers both
D-Q and detailed three phase nonlinear system model using
switching functions.
Abstract: In this paper, backup and recovery technique for Peer
to Peer applications, such as a distributed asynchronous Web-Based
Training system that we have previously proposed. In order to
improve the scalability and robustness of this system, all contents and
function are realized on mobile agents. These agents are distributed
to computers, and they can obtain using a Peer to Peer network
that modified Content-Addressable Network. In the proposed system,
although entire services do not become impossible even if some
computers break down, the problem that contents disappear occurs
with an agent-s disappearance. As a solution for this issue, backups
of agents are distributed to computers. If a failure of a computer is
detected, other computers will continue service using backups of the
agents belonged to the computer.
Abstract: This paper presents a systematic procedure for modelling and simulation of a power system installed with a power system stabilizer (PSS) and a flexible ac transmission system (FACTS)-based controller. For the design purpose, the model of example power system which is a single-machine infinite-bus power system installed with the proposed controllers is developed in MATLAB/SIMULINK. In the developed model synchronous generator is represented by model 1.1. which includes both the generator main field winding and the damper winding in q-axis so as to evaluate the impact of PSS and FACTS-based controller on power system stability. The model can be can be used for teaching the power system stability phenomena, and also for research works especially to develop generator controllers using advanced technologies. Further, to avoid adverse interactions, PSS and FACTS-based controller are simultaneously designed employing genetic algorithm (GA). The non-linear simulation results are presented for the example power system under various disturbance conditions to validate the effectiveness of the proposed modelling and simultaneous design approach.
Abstract: Dual motor drives fed by single inverter is
purposely designed to reduced size and cost with respect to
single motor drives fed by single inverter. Previous researches
on dual motor drives only focus on the modulation and the
averaging techniques. Only a few of them, study the
performance of the drives based on different speed controller
other than Proportional and Integrator (PI) controller. This
paper presents a detailed comparative study on fuzzy rule-base
in Fuzzy Logic speed Controller (FLC) for Dual Permanent
Magnet Synchronous Motor (PMSM) drives. Two fuzzy speed
controllers which are standard and simplified fuzzy speed
controllers are designed and the results are compared and
evaluated. The standard fuzzy controller consists of 49 rules
while the proposed controller consists of 9 rules determined by
selecting the most dominant rules only. Both designs are
compared for wide range of speed and the robustness of both
controllers over load disturbance changes is tested to
demonstrate the effectiveness of the simplified/reduced rulebase.
Abstract: In this paper the authors propose a flexible electronic solution, to improve the energetic efficiency of a thermo plant. This is achieved by replacing the mechanical gear box, placed traditionally between a gas turbine and a synchronous generator; by a power electronic converter. After reminding problematic of gear boxes and interest of a proposed electronic solution in high power plants, the authors describe a new control strategy for an indirect frequency converter, which is characterized by its high efficiency due to the use of SWM: Square Wave Modulation. The main advantage of this mode is the quasi absence of switching losses. A control method is also proposed to resolve some problems incurred by using square wave modulation, in particular to reduce the harmonics distortion of the output inverter voltage and current. Simulation examples as well as experimental results are included.
Abstract: This article describes design of the 8-bit asynchronous
microcontroller simulation model in VHDL. The model is created in
ISE Foundation design tool and simulated in Modelsim tool. This
model is a simple application example of asynchronous systems
designed in synchronous design tools. The design process of creating
asynchronous system with 4-phase bundled-data protocol and with
matching delays is described in the article. The model is described in
gate-level abstraction.
The simulation waveform of the functional construction is the
result of this article. Described construction covers only the
simulation model. The next step would be creating synthesizable
model to FPGA.
Abstract: The controllable electrical loss which consists of the
copper loss and iron loss can be minimized by the optimal control of
the armature current vector. The control algorithm of current vector
minimizing the electrical loss is proposed and the optimal current
vector can be decided according to the operating speed and the load
conditions. The proposed control algorithm is applied to the
experimental PM motor drive system and this paper presents a
modern approach of speed control for permanent magnet
synchronous motor (PMSM) applied for Electric Vehicle using a
nonlinear control. The regulation algorithms are based on the
feedback linearization technique. The direct component of the current
is controlled to be zero which insures the maximum torque operation.
The near unity power factor operation is also achieved. More over,
among EV-s motor electric propulsion features, the energy efficiency
is a basic characteristic that is influenced by vehicle dynamics and
system architecture. For this reason, the EV dynamics are taken into
account.
Abstract: The paper deals with the comparison study of
harmonic detection methods for a shunt active power filter. The
%THD and the power factor value at the PCC point after
compensation are considered for the comparison. There are three
harmonic detection methods used in the paper that are synchronous
reference frame method, synchronous detection method, and DQ axis
with Fourier method. In addition, the ideal current source is used to
represent the active power filter by assuming an infinitely fast
controller action of the active power filter. The simulation results
show that the DQ axis with Fourier method provides the minimum
%THD after compensation compared with other methods. However,
the power factor value at the PCC point after compensation is slightly
lower than that of synchronous detection method.
Abstract: This paper studies the design of a simple constellation
precoding for a multiple-input multiple-output orthogonal frequency
division multiplexing (MIMO-OFDM) system over Rayleigh fading
channels where OFDM is used to keep the diversity replicas orthogonal
and reduce ISI effects. A multi-user environment with K synchronous
co-channel users is considered. The proposed scheme provides
a bandwidth efficient transmission for individual users by increasing
the system throughput. In comparison with the existing coded
MIMO-OFDM schemes, the precoding technique is designed under
the consideration of its low implementation complexity while providing
a comparable error performance to the existing schemes.
Analytic and simulation results have been presented to show the distinguished
error performance.
Abstract: This paper mainly proposes an efficient modified
particle swarm optimization (MPSO) method, to identify a slidercrank
mechanism driven by a field-oriented PM synchronous motor.
In system identification, we adopt the MPSO method to find
parameters of the slider-crank mechanism. This new algorithm is
added with “distance" term in the traditional PSO-s fitness function to
avoid converging to a local optimum. It is found that the comparisons
of numerical simulations and experimental results prove that the
MPSO identification method for the slider-crank mechanism is
feasible.