Abstract: The use of renewable substitutes in various semi-structural and structural applications has experienced an increase since the last few decades. Sandwich panels have been used for many decades, although research on understanding the effects of the core structures on the panels’ fire-reaction properties is limited. The current work investigates the fire-performance of a corrugated sandwich panel made from renewable, biodegradable, and sustainable material, plywood. The bench-scale fire testing apparatus, cone-calorimeter, was employed to evaluate the required fire-reaction properties of the sandwich core in a panel configuration, with three corrugated layers glued together with face-sheets under a heat irradiance of 50 kW/m2. The study helped in documenting a unique heat release trend associated with the fire performance of the 3-layered corrugated sandwich panels and in understanding the structural stability of the samples in the event of a fire. Furthermore, the total peak heat release rate was observed to be around 421 kW/m2, which is significantly low compared to many polymeric materials in the literature. The total smoke production was also perceived to be very limited compared to other structural materials, and the total heat release was also nominal. The time to ignition of 21.7 s further outlined the advantages of using the plywood component since polymeric composites, even with flame-retardant additives, tend to ignite faster. Overall, the corrugated plywood sandwich panels had significant fire-reaction properties and could have important structural applications. The possible use of structural panels made from bio-degradable material opens a new avenue for the use of similar structures in sandwich panel preparation.
Abstract: In the present study, the aerodynamic performance of a rigid two-dimensional pitching bio-inspired corrugate airfoil was numerically investigated at Reynolds number of 14000. The Open Field Operations And Manipulations (OpenFOAM) computational fluid dynamic tool is used to solve flow governing equations numerically. The k-ω SST turbulence model with low Reynolds correction (k-ω SST LRC) and the pimpleDyMFOAM solver are utilized to simulate the flow field around pitching bio-airfoil. The lift and drag coefficients of the airfoil are calculated at reduced frequencies k=1.24-4.96 and the angular amplitude of A=5°-20°. Results show that in a fixed reduced frequency, the absolute value of the sectional lift and drag coefficients increase with increasing pitching amplitude. In a fixed angular amplitude, the absolute value of the lift and drag coefficients increase as the pitching reduced frequency increases.
Abstract: Due to the numerous advantages of steel corrugated
web girders, its application field is growing for bridges as well as for
buildings. The global stability behavior of such girders is
significantly larger than those of conventional I-girders with flat web,
thus the application of the structural steel material can be
significantly reduced. Design codes and specifications do not provide
clear and complete rules or recommendations for the determination of
the lateral torsional buckling (LTB) resistance of corrugated web
girders. Therefore, the authors made a thorough investigation
regarding the LTB resistance of the corrugated web girders. Finite
element (FE) simulations have been performed to develop new
design formulas for the determination of the LTB resistance of
trapezoidally corrugated web girders. FE model is developed
considering geometrical and material nonlinear analysis using
equivalent geometric imperfections (GMNI analysis). The equivalent
geometric imperfections involve the initial geometric imperfections
and residual stresses coming from rolling, welding and flame cutting.
Imperfection sensitivity analysis was performed to determine the
necessary magnitudes regarding only the first eigenmodes shape
imperfections. By the help of the validated FE model, an extended
parametric study is carried out to investigate the LTB resistance for
different trapezoidal corrugation profiles. First, the critical moment of
a specific girder was calculated by FE model. The critical moments
from the FE calculations are compared to the previous analytical
calculation proposals. Then, nonlinear analysis was carried out to
determine the ultimate resistance. Due to the numerical
investigations, new proposals are developed for the determination of
the LTB resistance of trapezoidally corrugated web girders through a
modification factor on the design method related to the conventional
flat web girders.
Abstract: This paper presents the performance, based on exergy analysis of double flow solar air heaters with corrugated and flat plate absorber. A mathematical model of double flow solar air heater based on energy balance equations has been presented and the results obtained have been compared with that of a conventional flat-plate solar air heater. The double flow corrugated absorber solar air heater performs thermally better than the flat plate double flow and conventional flat-plate solar air heater under same operating conditions. However, the corrugated absorber leads to higher pressure drop thereby increasing pumping power. The results revealed that the energy and exergy efficiencies of double flow corrugated absorber solar air heater is much higher than conventional solar air heater with the concept involving of increase in heat transfer surface area and turbulence in air flow. The results indicate that the energy efficiency increases, however, exergy efficiency decreases with increase in mass flow rate.
Abstract: Contact width and contact stress are important parameters related to the leakage behavior of corrugated metal gasket. In this study, contact width and contact stress of three-layer corrugated metal gasket are investigated due to the modulus of elasticity and thickness of surface layer for 2 type gasket (0-MPa and 400-MPa mode). A finite element method was employed to develop simulation solution to analysis the effect of each parameter. The result indicated that lowering the modulus of elasticity ratio of surface layer will result in better contact width but the average contact stresses are smaller. When the modulus of elasticity ratio is held constant with thickness ratio increase, its contact width has an increscent trend otherwise the average contact stress has decreased trend.
Abstract: This paper deals with the analytical investigation of thermal and thermohydraulic performance of double flow solar air heaters with corrugated and flat plate absorber. A mathematical model of double flow solar air heater has been presented, and a computer program in C++ language is developed to estimate the outlet temperature of air for the evaluation of thermal and thermohydraulic efficiency by solving the governing equations numerically using relevant correlations for heat transfer coefficients. The results obtained from the mathematical model is compared with the available experimental results and it is found to be reasonably good. The results show that the double flow solar air heaters have higher efficiency than conventional solar air heater, although the double flow corrugated absorber is superior to that of flat plate double flow solar air heater. It is also observed that the thermal efficiency increases with increase in mass flow rate; however, thermohydraulic efficiency increases with increase in mass flow rate up to a certain limit, attains the maximum value, then thereafter decreases sharply.
Abstract: Optimizations of Plate Heat Exchangers (PHS) have received great attention in the past decade. In this study, heat transfer and pressure drop coefficients are compared for rectangular and circular PHS employing numerical simulations. Plates are designed to have equivalent areas. Simulations were implemented to investigate the efficiency of PHSs considering heat transfer, friction factor and pressure drop. Amount of heat transfer and pressure drop was obtained for different range of Reynolds numbers. These two parameters were compared with aim of F "weighting factor correlation". In this comparison, the minimum amount of F indicates higher efficiency. Results reveal that the F value for rectangular shape is less than circular plate, and hence using rectangular shape of PHS is more efficient than circular one. It was observed that, the amount of friction factor is correlated to the Reynolds numbers, such that friction factor decreased in both rectangular and circular plates with an increase in Reynolds number. Furthermore, such simulations revealed that the amount of heat transfer in rectangular plate is more than circular plate for different range of Reynolds numbers. The difference is more distinct for higher Reynolds number. However, amount of pressure drop in circular plate is less than rectangular plate for the same range of Reynolds numbers which is considered as a negative point for rectangular plate efficiency. It can be concluded that, while rectangular PHSs occupy more space than circular plate, the efficiency of rectangular plate is higher.
Abstract: Contact width and contact stress are important design parameters for optimizing corrugated metal gasket performance based on elastic and plastic contact stress. In this study, we used a three-layer metal gasket with Al, Cu, Ni as the outer layer, respectively. A finite element method was employed to develop simulation solution. The gasket model was simulated by using two simulation stages which are forming and tightening simulation. The simulation result shows that aluminum with tangent modulus, Ehal = Eal/150 has the highest slope for contact width. The slope of contact width for plastic mode gasket was higher than the elastic mode gasket.
Abstract: Steel extended end plate bolted connections are
recommended to be widely utilized in special moment-resisting frame
subjected to monotonic loading. Improper design of steel beam to
column connection can lead to the collapse and fatality of structures.
Therefore comprehensive research studies of beam to column
connection design should be carried out. Also the performance and
effect of corrugated on the strength of beam column end plate
connection up to failure under monotonic loading in horizontal
direction is presented in this paper. The non-linear elastic–plastic
behavior has been considered through a finite element analysis using
the multi-purpose software package LUSAS. The effect of vertically
and horizontally types of corrugated web was also investigated.
Abstract: This study presented to reduce earthquake damage and
emergency rehabilitation of critical structures such as schools, hightech
factories, and hospitals due to strong ground motions associated
with climate changes. Regarding recent trend, a strong earthquake
causes serious damage to critical structures and then the critical
structure might be influenced by sequence aftershocks (or tsunami)
due to fault plane adjustments. Therefore, in order to improve seismic
performance of critical structures, retrofitted or strengthening study
of the structures under aftershocks sequence after emergency
rehabilitation of the structures subjected to strong earthquakes is
widely carried out. Consequently, this study used composite material
for emergency rehabilitation of the structure rather than concrete and
steel materials because of high strength and stiffness, lightweight,
rapid manufacturing, and dynamic performance. Also, this study was
to develop or improve the seismic performance or seismic retrofit of
critical structures subjected to strong ground motions and earthquake
aftershocks, by utilizing GFRP-Corrugated Infill Panels (GCIP).
Abstract: Present study numerically investigates the flow field and heat transfer of water in two dimensional sinusoidal and rectangular corrugated wall channels. Simulations are performed for fully developed flow conditions at inlet sections of the channels that have 12 waves. The temperature of the input fluid is taken to be less than that temperature of wavy walls. The governing continuity, momentum and energy equations are numerically solved using finite volume method based on SIMPLE technique. The investigation covers Reynolds number in the rage of 100-1000. The effects of the distance between upper and lower corrugated walls are studied by varying Hmin/Hmax ratio from 0.3 to 0.5 for keeping wave length and wave amplitude values fixed for both geometries. The effects of the wall geometry, Reynolds number and the distance between walls on the flow characteristics, the local Nusselt number and heat transfer are studied. It is found that heat transfer enhancement increases by usage of corrugated horizontal walls in an appropriate Reynolds number regime and channel height.
Abstract: Corrugated wire mesh laminates (CWML) are a class
of engineered open cell structures that have potential for applications
in many areas including aerospace and biomedical engineering. Two
different methods of fabricating corrugated wire mesh laminates from
stainless steel, one using a high temperature Lithobraze alloy and the
other using a low temperature Eutectic solder for joining the
corrugated wire meshes are described herein. Their implementation is
demonstrated by manufacturing CWML samples of 304 and 316
stainless steel (SST). It is seen that due to the facility of employing
wire meshes of different densities and wire diameters, it is possible to
create CWML laminates with a wide range of effective densities. The
fabricated laminates are tested under uniaxial compression. The
variation of the compressive yield strength with relative density of the
CWML is compared to the theory developed by Gibson and Ashby for
open cell structures [22]. It is shown that the compressive strength of
the corrugated wire mesh laminates can be described using the same
equations by using an appropriate value for the linear coefficient in the
Gibson-Ashby model.
Abstract: The development of biomimetic micro-aerial-vehicles
(MAVs) with flapping wings is the future trend in military/domestic
field. The successful flight of MAVs is strongly related to the
understanding of unsteady aerodynamic performance of low Reynolds
number airfoils under dynamic flapping motion. This study explored
the effects of flapping frequency, stroke amplitude, and the inclined
angle of stroke plane on lift force and thrust force of a bio-inspiration
corrugated airfoil with 33 full factorial design of experiment and
ANOVA analysis. Unsteady vorticity flows over a corrugated thin
airfoil executing flapping motion are computed with time-dependent
two-dimensional laminar incompressible Reynolds-averaged
Navier-Stokes equations with the conformal hybrid mesh. The tested
freestream Reynolds number based on the chord length of airfoil as
characteristic length is fixed of 103. The dynamic mesh technique is
applied to model the flapping motion of a corrugated airfoil. Instant
vorticity contours over a complete flapping cycle clearly reveals the
flow mechanisms for lift force generation are dynamic stall, rotational
circulation, and wake capture. The thrust force is produced as the
leading edge vortex shedding from the trailing edge of airfoil to form a
reverse von Karman vortex. Results also indicated that the inclined
angle is the most significant factor on both the lift force and thrust
force. There are strong interactions between tested factors which mean
an optimization study on parameters should be conducted in further
runs.
Abstract: Ten simply supported grossly underreinforced
tapered concrete beams of full size were tested upto complete
collapse under flexural effect .Out of 10 beams, 5 beams were
nonfibrous and the remaining beams contained fibres. The beams
had a variation in the tapered angle as 2°, 4°, 6°, 8° and 10°. The
concrete mix, conventional steel and the type of fibre used were
held constant. Flat corrugated steel fibres were utilized as
secondary reinforcement. The strength and stability parameters
were measured. It is established that the fibrous tapered beams can
be used economically in earthquake prone areas.
Abstract: Composite steel-concrete slabs using thin-walled
corrugated steel sheets with embossments represent a modern and
effective combination of steel and concrete. However, the design
of new types of sheeting is conditional on the execution of expensive
and time-consuming laboratory testing. The effort to develop
a cheaper and faster method has lead to many investigations all over
the world. In our paper we compare the results from our experiments
involving vacuum loading, four-point bending and small-scale shear
tests.
Abstract: The corrugated steel cladding used to cover most of
steel buildings is considered as non-structural element. This research
will reflect the effect of cladding as a shear diaphragm in increasing
the normal elastic capacity of columns. This study is important
because of the lack of information of the behavior of cladding and
secondary members in various codes. Mathematical models for six
different cases are carried by software. The results extracted from the
program have been plotted showing the effects of different variables
on the ultimate load of column. The variables considered in our
research are the spacing between columns and the thickness of the
corrugated sheet representing the sheet stiffness.
Abstract: Effect of geometry on crushing behavior, energy absorption and failure mode of woven roving jute fiber/epoxy laminated composite tubes were experimentally studied. Investigations were carried out on three different geometrical types of composite tubes (circular, square and radial corrugated) subjected to axial compressive loading. It was observed in axial crushing study that the load bearing capability is significantly influenced by corrugation geometry. The influence of geometries of specimens was supported by the plotted load – displacement curves of the tests.
Abstract: The flow and heat transfer mechanism in convex
corrugated tubes have been investigated through numerical
simulations in this paper. Two kinds of tube types named as symmetric
corrugated tube (SCT) and asymmetric corrugated tube (ACT) are
modeled and studied numerically based on the RST model. The
predictive capability of RST model is examined in the corrugation wall
in order to check the reliability of RST model under the corrugation
wall condition. We propose a comparison between the RST modelling
the corrugation wall with existing direct numerical simulation of Maaß
C and Schumann U [14]. The numerical results pressure coefficient at
different profiles between RST and DNS are well matched. The
influences of large corrugation tough radii to heat transfer and flow
characteristic had been considered. Flow and heat transfer comparison
between SCT and ACT had been discussed. The numerical results
show that ACT exhibits higher overall heat transfer performance than
SCT.
Abstract: The main focus of the work was concerned with hydrodynamic and thermal analysis of the plate heat exchanger channel with corrugation patterns suggested to be triangular, sinusoidal, and square corrugation. This study was to numerically model and validate the triangular corrugated channel with dimensions/parameters taken from open literature, and then model/analyze both sinusoidal, and square corrugated channel referred to the triangular model. Initially, 2D modeling with local extensive analysis for triangular corrugated channel was carried out. By that, all local pressure drop, wall shear stress, friction factor, static temperature, heat flux, Nusselt number, and surface heat coefficient, were analyzed to interpret the hydrodynamic and thermal phenomena occurred in the flow. Furthermore, in order to facilitate confidence in this model, a comparison between the values predicted, and experimental results taken from literature for almost the same case, was done. Moreover, a holistic numerical study for sinusoidal and square channels together with global comparisons with triangular corrugation under the same condition, were handled. Later, a comparison between electric, and fluid cooling through varying the boundary condition was achieved. The constant wall temperature and constant wall heat flux boundary conditions were employed, and the different resulted Nusselt numbers as a consequence were justified. The results obtained can be used to come up with an optimal design, a 'compromise' between heat transfer and pressure drop.
Abstract: Primary barrier of membrane type LNG containment system consist of corrugated 304L stainless steel. This 304L stainless steel is austenitic stainless steel which shows different material behaviors owing to phase transformation during the plastic work. Even though corrugated primary barriers are subjected to significant amounts of pre-strain due to press working, quantitative mechanical behavior on the effect of pre-straining at cryogenic temperatures are not available. In this study, pre-strain level and pre-strain temperature dependent tensile tests are carried to investigate mechanical behaviors. Also, constitutive equations with material parameters are suggested for a verification study.