Abstract: Insulators are one of the most significant equipment in power system. The insulators’ operation may affect the power flow, line loss and reliability. The electrical parameters that influence the performance of insulator are surface leakage current, corona and dry band arcing. Electric field stresses on the insulator surface will degrade the insulating properties and lead to puncture. Electric filed stresses can be analyzed by numerical methods and experimental evaluation. As per economic aspects, evaluation by numerical methods are best. In outdoor insulation, a hydrophobic surface can facilitate to prevent water film formation on the insulation surface, which is decisive for diminishing leakage currents and partial discharge (PD) under heavy polluted environments and harsh weather conditions. Polymer materials like silicone rubber have an outstanding hydrophobic property among general insulation materials. In this paper, electrical field intensity of 220 kV porcelain and polymer double tension insulator strings at critical regions are analyzed and compared by using Finite Element Method. Hydrophobic conditions of polymer insulator with equal and unequal water molecule conditions are verified by using finite element method.
Abstract: There is a great problem in testing and investigations the reliability of different type of transformers insulation materials. It summarized in how to create and simulate the real conditions of working transformer and testing its insulation materials for Partial Discharge PD, typically as in the working mode. A lot of tests may give untrue results as the physical behavior of the insulation material differs under tests from its working condition. In this work, the real working conditions were simulated, and a large number of specimens have been tested. The investigations first stage, begin with choosing samples of different types of insulation materials (papers, pressboards, etc.). The second stage, the samples were dried in ovens at 105 C0and 0.01bar for 48 hours, and then impregnated with dried and gasless oil (the water content less than 6 ppm.) at 105 C0and 0.01bar for 48 hours, after so specimen cooling at room pressure and temperature for 24 hours. The third stage is investigating PD for the samples using ICM PD measuring device. After that, a continuous test on oil-impregnated insulation materials (paper, pressboards) was developed, and the phase resolved partial discharge pattern of PD signals was measured. The important of this work in providing the industrial sector with trusted high accurate measuring results based on real simulated working conditions. All the PD patterns (results) associated with a discharge produced in well-controlled laboratory condition. They compared with other previous and other laboratory results. In addition, the influence of different temperatures condition on the partial discharge activities was studied.
Abstract: Insulation performance of a gas insulated system is severely affected by particle contaminants. These metallic particles adversely affect the characteristics of insulating system. These particles can produce surface charges due to partial discharge activities. These particles which are free to move enhance the local electric fields. This paper deals with the influence of conducting particle placed in a co-axial duct on the discharge characteristics of gas mixtures. Co-axial duct placed in a high pressure chamber is used for the purpose. A gas pressure of 0.1, 0.2 and 0.3 MPa have been considered with a 10:90 SF6 and N2 gas mixtures. The 2D and 3D histograms of clean duct and duct with copper particle are discussed in this paper.
Abstract: In this paper, partial discharge analysis is performed in cavities artificially created in insulation. The setup is according with Cigre-II Method. Circular Samples created from Perspex Sheet with different configuration with changing number of cavities. Assessment of insulation health can be performed by Partial Discharge measurement as this has been found to be important means of condition monitoring. The experiments are done using MPD 540, which is a modern partial discharge measurement system. By analyzing the PD activity obtained for various voids/cavities, it is observed that the PD voltages show variation for cavity’s diameter, depth even for its ratios. This can be employed for scrutiny of insulation system.
Abstract: Mineral oil is commonly used for high voltage
transformer insulation. The insulation quality of mineral oil is
affecting the operation process of high voltage transformer. There are
many contaminations which could decrease the insulation quality of
mineral oil. One of them is water. This research talks about the effect
of water content on dielectric properties, physic properties, and
partial discharge pattern on mineral oil. Samples were varied with 10
varieties of water content value. And then all samples would be tested
to measure the dielectric properties, physic properties, and partial
discharge pattern. The result of this research showed that an
increment of water content value would decrease the insulation
quality of mineral oil.
Abstract: Worldwide, most PILC MV underground cables in use
are approaching the end of their design life; hence, failures are likely
to increase. This paper studies the electric field and potential
distributions within the PILC insulted cable containing common
void-defect. The finite element model of the performance of the
belted PILC MV underground cable is presented. The variation of the
electric field stress within the cable using the Finite Element Method
(FEM) is concentrated. The effects of the void-defect within the
insulation are given. Outcomes will lead to deeper understanding of
the modeling of Paper Insulated Lead Covered (PILC) and electric
field response of belted PILC insulted cable containing void defect.
Abstract: An acoustic emission (AE) technique is useful for
detection of partial discharges (PDs) at a joint and a terminal section of
a cross-linked polyethylene (XLPE) cable. For AE technique, it is not
difficult to detect a PD using AE sensors. However, it is difficult to
grasp whether the detected AE signal is owing to a single discharge or
not. Additionally, when an AE technique is applied at a terminal
section of a XLPE cable in salt pollution district, for example, there is
possibility of detection of AE signals owing to creeping discharges on
the surface of electric power apparatus. In this study, we evaluated AE
signals in order to grasp what kind of information we can get from
detected AE signals. The results showed that envelop detection of AE
signal and a period which some AE signals were continuously detected
were good indexes for estimating state-of-discharge.
Abstract: For lack of the visualization of the ultrasonic detection
method of partial discharge (PD), the ultrasonic detection technology
combined with the X-ray visual detection method (UXV) is proposed.
The method can conduct qualitative analysis accurately and conduct
reliable positioning diagnosis to the internal insulation defects of
GIS, and while it could make up the blindness of the X-ray visual
detection method and improve the detection rate. In this paper, an
experimental model of GIS is used as the trial platform, a variety of
insulation defects are set inside the GIS cavity. With the proposed
method, the ultrasonic method is used to conduct the preliminary
detection, and then the X-ray visual detection is used to locate and
diagnose precisely. Therefore, the proposed UXV technology is
feasible and practical.
Abstract: This paper presents the effectiveness of artificial
intelligent technique to apply for pattern recognition and
classification of Partial Discharge (PD). Characteristics of PD signal
for pattern recognition and classification are computed from the
relation of the voltage phase angle, the discharge magnitude and the
repeated existing of partial discharges by using statistical and fractal
methods. The simplified fuzzy ARTMAP (SFAM) is used for pattern
recognition and classification as artificial intelligent technique. PDs
quantities, 13 parameters from statistical method and fractal method
results, are inputted to Simplified Fuzzy ARTMAP to train system
for pattern recognition and classification. The results confirm the
effectiveness of purpose technique.
Abstract: It is well known that metallic particles reduce the
reliability of Gas-Insulated Substation (GIS) equipments by initiating
partial discharge (PDs) that can lead to breakdown and complete
failure of GIS. This paper investigates the characteristics of PDs
caused by metallic particle adhering to the solid spacer. The PD
detection and measurement were carried out by using IEC 60270
method with particles of different sizes and at different positions on
the spacer surface. The results show that a particle of certain size at
certain position possesses a unique PD characteristic as compared to
those caused by particles of different sizes and/or at different
positions. Therefore PD characteristics may be useful for the particle
size and position identification.
Abstract: Partial Discharge measurement is a very important
means of assessing the integrity of insulation systems in a High
Voltage apparatus. In compressed gas insulation systems, floating
particles can initiate partial discharge activities which adversely
affect the working of insulation. Partial Discharges below the
inception voltage also plays a crucial in damaging the integrity of
insulation over a period of time. This paper discusses the effect of
loose and fixed Copper and Nichrome wire particles on the PD
characteristics in SF6-N2 (10:90) gas mixtures at a pressure of
0.4MPa. The Partial Discharge statistical parameters and their
correlation to the observed results are discussed.
Abstract: Insulation used in transformer is mostly oil pressboard insulation. Insulation failure is one of the major causes of catastrophic failure of transformers. It is established that partial discharges (PD) cause insulation degradation and premature failure of insulation. Online monitoring of PDs can reduce the risk of catastrophic failure of transformers. There are different techniques of partial discharge measurement like, electrical, optical, acoustic, opto-acoustic and ultra high frequency (UHF). Being non invasive and non interference prone, acoustic emission technique is advantageous for online PD measurement. Acoustic detection of p.d. is based on the retrieval and analysis of mechanical or pressure signals produced by partial discharges. Partial discharges are classified according to the origin of discharges. Their effects on insulation deterioration are different for different types. This paper reports experimental results and analysis for classification of partial discharges using acoustic emission signal of laboratory simulated partial discharges in oil pressboard insulation system using three different electrode systems. Acoustic emission signal produced by PD are detected by sensors mounted on the experimental tank surface, stored on an oscilloscope and fed to computer for further analysis. The measured AE signals are analyzed using discrete wavelet transform analysis and wavelet packet analysis. Energy distribution in different frequency bands of discrete wavelet decomposed signal and wavelet packet decomposed signal is calculated. These analyses show a distinct feature useful for PD classification. Wavelet packet analysis can sort out any misclassification arising out of DWT in most cases.
Abstract: This paper investigates the influence of various
parameters on the behaviour of water droplets on polymeric surfaces
under high electric fields. An inclined plane test was carried out to
understand the droplet behaviour in strong electric field. Parameters
such as water droplet conductivity, droplet volume, polymeric
surface roughness and droplet positioning with respect to the
electrodes were studied. The flashover voltage is affected by all
aforementioned parameters. The droplet positioning is in some cases
more vital than the droplet volume. Surface damages were analysed
using Scanning Electron Microscopy (SEM) studies and by Energy
dispersive X-ray Analysis (EDAX). It is observes that magnitude of
discharge have direct influence on amount of surface da
Abstract: Measurements of capacitance C and dissipation
factor tand of the stator insulation system provide useful information
about internal defects within the insulation. The index k is defined as
the proportionality constant between the changes at high voltage of
capacitance DC and of the dissipation factor Dtand . DC and
Dtand values were highly correlated when small flat defects were
within the insulation and that correlation was lost in the presence of
large narrow defects like electrical treeing. The discrimination
between small and large defects is made resorting to partial discharge
PD phase angle analysis. For the validation of the results, C and tand
measurements were carried out in a 15MVA 4160V steam turbine
turbogenerator placed in a sugar mill. In addition, laboratory test
results obtained by other authors were analyzed jointly. In such
laboratory tests, model coil bars subjected to thermal cycling resulted
highly degraded and DC and Dtand values were not correlated. Thus,
the index k could not be calculated.
Abstract: Design of Converter transformer insulation is a major
challenge. The insulation of these transformers is stressed by both
AC and DC voltages. Particle contamination is one of the major
problems in insulation structures, as they generate partial discharges
leading it to major failure of insulation. Similarly corona discharges
occur in transformer insulation. This partial discharge due to particle
movement / corona formation in insulation structure under different
voltage wave shapes, are different. In the present study, UHF
technique is adopted to understand the discharge activity and could
be realized that the characteristics of UHF signal generated under
low and high fields are different. In the case of corona generated
signal, the frequency content of the UHF sensor output lies in the
range 0.3-1.2 GHz and is not much varied except for its increase in
magnitude of discharge with the increase in applied voltage. It is
realized that the current signal injected due to partial
discharges/corona is about 4ns duration measured for first one half
cycle. Wavelet technique is adopted in the present study. It allows
one to identify the frequency content present in the signal at different
instant of time. The STD-MRA analysis helps one to identify the
frequency band in which the energy content of the UHF signal is
maximum.
Abstract: In order to perform on-line measuring and detection
of PD signals, a total solution composing of an HFCT, A/D
converter and a complete software package is proposed. The
software package includes compensation of HFCT contribution,
filtering and noise reduction using wavelet transform and soft
calibration routines. The results have shown good performance and
high accuracy.
Abstract: This paper presents the results of a comprehensive
investigation of five blackouts that occurred on 28 August to 8
September 2011 due to bushing failures of the 132/33 kV, 125 MVA
transformers at JBB Ali Grid station. The investigation aims to
explore the root causes of the bushing failures and come up with
recommendations that help in rectifying the problem and avoiding the
reoccurrence of similar type of incidents. The incident reports about
the failed bushings and the SCADA reports at this grid station were
examined and analyzed. Moreover, comprehensive power quality
field measurements at ten 33/11 kV substations (S/Ss) in JBB Ali
area were conducted, and frequency scans were performed to verify
any harmonic resonance frequencies due to power factor correction
capacitors. Furthermore, the daily operations of the on-load tap
changers (OLTCs) of both the 125 MVA and 20 MVA transformers
at JBB Ali Grid station have been analyzed. The investigation
showed that the five bushing failures were due to a local problem, i.e.
internal degradation of the bushing insulation. This has been
confirmed by analyzing the time interval between successive OLTC
operations of the faulty grid transformers. It was also found that
monitoring the number of OLTC operations can help in predicting
bushing failure.
Abstract: Power cables are vulnerable to failure due to aging or
defects that occur with the passage of time under continuous
operation and loading stresses. PD detection and characterization
provide information on the location, nature, form and extent of the
degradation. As a result, PD monitoring has become an important
part of condition based maintenance (CBM) program among power
utilities. Online partial discharge (PD) localization of defect sources
in power cable system is possible using the time of flight method.
The information regarding the time difference between the main and
reflected pulses and cable length can help in locating the partial
discharge source along the cable length. However, if the length of
the cable is not known and the defect source is located at the extreme
ends of the cable or in the middle of the cable, then double ended
measurement is required to indicate the location of PD source. Use of
multiple sensors can also help in discriminating the cable PD or local/
external PD. This paper presents the experience and results from
online partial discharge measurements conducted in the laboratory
and the challenges in partial discharge source localization.
Abstract: Partial discharge (PD) detection is an important
method to evaluate the insulation condition of metal-clad apparatus.
Non-intrusive sensors which are easy to install and have no
interruptions on operation are preferred in onsite PD detection.
However, it often lacks of accuracy due to the interferences in PD
signals. In this paper a novel PD extraction method that uses frequency
analysis and entropy based time-frequency (TF) analysis is introduced.
The repetitive pulses from convertor are first removed via frequency
analysis. Then, the relative entropy and relative peak-frequency of
each pulse (i.e. time-indexed vector TF spectrum) are calculated and
all pulses with similar parameters are grouped. According to the
characteristics of non-intrusive sensor and the frequency distribution
of PDs, the pulses of PD and interferences are separated. Finally the
PD signal and interferences are recovered via inverse TF transform.
The de-noised result of noisy PD data demonstrates that the
combination of frequency and time-frequency techniques can
discriminate PDs from interferences with various frequency
distributions.
Abstract: The power transformer is the most expensive, indispensable and arguably the most important equipment item in a power system Insulation failure in transformers can cause long term interruption to supply and loss of revenue and the condition assessment of the insulation is thus an important maintenance procedure. Oil-impregnated transformer insulation consists of mainly organic materials including mineral oil and cellulose-base paper and pressboard. The operating life of cellulose-based insulation, as with most organic insulation, depends heavily on its operating temperature rise above ambient. This paper reports results of a laboratory-based experimental investigation of partial discharge (PD) activity at high temperature in oil-impregnated insulation. The experiments reported here are part an on-going programme aimed at investigating the way in which insulation deterioration can be monitored and quantified by use of partial discharge diagnostics. Partial discharge patterns were recorded and analysed during increasing and decreasing phases of the temperature. The effect of ageing of the insulation on the PD patterns in oil and oil-impregnated insulation are also considered.