Abstract: In the present study, the free vibration of magnetostrictive nano-plate (MsNP) resting on the Pasternak foundation is investigated. Firstly, the modified couple stress (MCS) and nonlocal elasticity theories are compared together and taken into account to consider the small scale effects; in this paper not only two theories are analyzed but also it improves the MCS theory is more accurate than nonlocal elasticity theory in such problems. A feedback control system is utilized to investigate the effects of a magnetic field. First-order shear deformation theory (FSDT), Hamilton’s principle and energy method are utilized in order to drive the equations of motion and these equations are solved by differential quadrature method (DQM) for simply supported boundary conditions. The MsNP undergoes in-plane forces in x and y directions. In this regard, the dimensionless frequency is plotted to study the effects of small scale parameter, magnetic field, aspect ratio, thickness ratio and compression and tension loads. Results indicate that these parameters play a key role on the natural frequency. According to the above results, MsNP can be used in the communications equipment, smart control vibration of nanostructure especially in sensor and actuators such as wireless linear micro motor and smart nano valves in injectors.
Abstract: The operating principle of magnetically controlled microelectromechanical system (MEMS) switches is based on controlling the beam movement under the influence of a magnetic field. Currently, there is a MEMS switch design with a flexible ferromagnetic electrode in the form of a fixed-terminal beam, with an electrode fastened on a straight or cranked anchor. The basic performance characteristics of magnetically controlled MEMS switches (service life, sensitivity, contact resistance, fast response) are largely determined by the flexible electrode design. To ensure the stable and controlled motion of the flexible electrode, it is necessary to provide the optimal design of a flexible electrode.
Abstract: The effect of magnetic field on the noise performance of the magnetic field tunable avalanche transit time (MAGTATT) device based on Si, designed to operate at W-band (75 – 110 GHz), has been studied in this paper. A comprehensive two-dimensional (2D) model has been developed. The simulation results show that due to the presence of applied external transverse magnetic field, both the noise spectral density and noise measure of the MAGTATT device increase significantly. The noise performance of the device has been found to be further deteriorated if the magnetic field strength is further increased. Hence, in order to achieve the magnetic field tuning of the radio frequency (RF) properties of impact avalanche transit time (IMPATT) source, the noise performance of it has to be sacrificed in fair extent. Moreover, it clearly indicates that an IMPATT source must be covered with appropriate magnetic shielding material to avoid undesirable shift in operating frequency and output power and objectionable amount of deterioration in noise performance due to the presence of external magnetic field.
Abstract: Nuclear Magnetic Resonance (NMR) spectroscopy is an indispensable technique used in structure determination of small and macromolecules to study their physical properties, elucidation of characteristic interactions, dynamics and thermodynamic processes. Quantum mechanics defines the theoretical description of NMR spectroscopy and treatment of the dynamics of nuclear spin systems. The phenomenon of residual dipolar coupling (RDCs) has become a routine tool for accurate structure determination by providing global orientation information of magnetic dipole-dipole interaction vectors within a common reference frame. This offers accessibility of distance-independent angular information and insights to local relaxation. The measurement of RDCs requires an anisotropic orientation medium for the molecules to partially align along the magnetic field. This can be achieved by introduction of liquid crystals or attaching a paramagnetic center. Although anisotropic paramagnetic tags continue to mark achievements in the biomolecular NMR of large proteins, its application in small organic molecules remains unspread. Here, we propose a strategy for the synthesis of a lanthanide tag and the measurement of RDCs in organic molecules using paramagnetic lanthanide complexes.
Abstract: Among the different cancer treatments that are currently used, hyperthermia has a promising potential due to the multiple benefits that are obtained by this technique. In general terms, hyperthermia is a method that takes advantage of the sensitivity of cancer cells to heat, in order to damage or destroy them. Within the different ways of supplying heat to cancer cells and achieve their destruction or damage, the use of magnetic nanoparticles has attracted attention due to the capability of these particles to generate heat under the influence of an external magnetic field. In addition, these nanoparticles have a high surface area and sizes similar or even lower than biological entities, which allow their approaching and interaction with a specific region of interest. The most used magnetic nanoparticles for hyperthermia treatment are those based on iron oxides, mainly magnetite and maghemite, due to their biocompatibility, good magnetic properties and chemical stability. However, in order to fulfill more efficiently the requirements that demand the treatment of magnetic hyperthermia, there have been investigations using ferrites that incorporate different metallic ions, such as Mg, Mn, Co, Ca, Ni, Cu, Li, Gd, etc., in their structure. This paper reports the synthesis of nanosized MgxMn1-xFe2O4 (x = 0.3 and 0.4) ferrites by sol-gel method and their evaluation in terms of heating capability and in vitro hemolysis to determine the potential use of these nanoparticles as thermoseeds for the treatment of cancer by magnetic hyperthermia. It was possible to obtain ferrites with nanometric sizes, a single crystalline phase with an inverse spinel structure and a behavior near to that of superparamagnetic materials. Additionally, at concentrations of 10 mg of magnetic material per mL of water, it was possible to reach a temperature of approximately 45°C, which is within the range of temperatures used for the treatment of hyperthermia. The results of the in vitro hemolysis assay showed that, at the concentrations tested, these nanoparticles are non-hemolytic, as their percentage of hemolysis is close to zero. Therefore, these materials can be used as thermoseeds for the treatment of cancer by magnetic hyperthermia.
Abstract: A quantum breathing mode has been theatrically studied in quantum dusty plasma. By using linear quantum hydrodynamic model, not only the quantum dispersion relation of rotation mode but also void structure has been derived in the presence of an external magnetic field. Although the phase velocity of the magnetized quantum breathing mode is greater than that of unmagnetized quantum breathing mode, attenuation of the magnetized quantum breathing mode along radial distance seems to be slower than that of unmagnetized quantum breathing mode. Clearly, drawing the quantum breathing mode in the presence and absence of a magnetic field, we found that the magnetic field alters the distribution of dust particles and changes the radial and azimuthal velocities around the axis. Because the magnetic field rotates the dust particles and collects them, it could compensate the void structure.
Abstract: As a pretreatment process of ballast water treatment, the performance of high gradient magnetic separation (HGMS) technology for the removal of particulates and microorganisms was studied. The results showed that HGMS process could effectively remove suspended particles larger than 5 µm and had ability to resist impact load. Microorganism could also be effectively removed by HGMS process, and the removal effect increased with increasing magnetic field strength. The maximum removal rates for Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) were 4016.1% and 9675.3% higher, respectively, than without the magnetic field. In addition, the superoxide dismutase (SOD) activity of the microbes decreased by 32.2% when the magnetic field strength was 15.4 mT for 72 min. The microstructure of the stainless steel wool was investigated, and the results showed that particle removal by HGMS has common function by the magnetic force of the high-strength, high-gradient magnetic field on weakly magnetic particles in the water, and on the stainless steel wool.
Abstract: The magnetohydrodynamic (MHD) Falkner-Skan
equations appear in study of laminar boundary layers flow over
a wedge in presence of a transverse magnetic field. The partial
differential equations of boundary layer problems in presence of
a transverse magnetic field are reduced to MHD Falkner-Skan
equation by similarity solution methods. This is a nonlinear ordinary
differential equation. In this paper, we solve this equation via
spectral collocation method based on Bessel functions of the first
kind. In this approach, we reduce the solution of the nonlinear
MHD Falkner-Skan equation to a solution of a nonlinear algebraic
equations system. Then, the resulting system is solved by Newton
method. We discuss obtained solution by studying the behavior
of boundary layer flow in terms of skin friction, velocity, various
amounts of magnetic field and angle of wedge. Finally, the results
are compared with other methods mentioned in literature. We can
conclude that the presented method has better accuracy than others.
Abstract: Dynamics of cathode spot has become a major part
of vacuum arc discharge with its high academic interest and
wide application potential. In this article, using a three-dimensional
statistical model, we simulate the distribution of the ignition
probability of a new cathode spot occurring in different magnetic
pressure on old cathode spot surface and at different arcing time.
This model for the ignition probability of a new cathode spot was
proposed in two typical situations, one by the pure isotropic random
walk in the absence of an external magnetic field, other by the
retrograde motion in external magnetic field, in parallel with the
cathode surface. We mainly focus on developed relationship between
the ignition probability density distribution of a new cathode spot and
the external magnetic field.
Abstract: The proposed method for speciation, preconcentration and determination of Fe(II) and Fe(III) in pharmaceutical products was developed using of alumina-coated magnetite nanoparticles (Fe3O4/Al2O3 NPs) as solid phase extraction (SPE) sorbent in magnetic mixed hemimicell solid phase extraction (MMHSPE) technique followed by flame atomic absorption spectrometry analysis. The procedure is based on complexation of Fe(II) with 1, 10-phenanthroline (OP) as complexing reagent for Fe(II) that immobilized on the modified Fe3O4/Al2O3 NPs. The extraction and concentration process for pharmaceutical sample was carried out in a single step by mixing the extraction solvent, magnetic adsorbents under ultrasonic action. Then, the adsorbents were isolated from the complicated matrix easily with an external magnetic field. Fe(III) ions determined after facility reduced to Fe(II) by added a proper reduction agent to sample solutions. Compared with traditional methods, the MMHSPE method simplified the operation procedure and reduced the analysis time. Various influencing parameters on the speciation and preconcentration of trace iron, such as pH, sample volume, amount of sorbent, type and concentration of eluent, were studied. Under the optimized operating conditions, the preconcentration factor of the modified nano magnetite for Fe(II) 167 sample was obtained. The detection limits and linear range of this method for iron were 1.0 and 9.0 - 175 ng.mL−1, respectively. Also the relative standard deviation for five replicate determinations of 30.00 ng.mL-1 Fe2+ was 2.3%.
Abstract: We present the concept and scientific methods and algorithms of our computation system called ATOMIC MATTERS. This is the first presentation of the new computer package, that allows its user to describe physical properties of atomic localized electron systems subject to electromagnetic interactions. Our solution applies to situations where an unclosed electron 2p/3p/3d/4d/5d/4f/5f subshell interacts with an electrostatic potential of definable symmetry and external magnetic field. Our methods are based on Crystal Electric Field (CEF) approach, which takes into consideration the electrostatic ligands field as well as the magnetic Zeeman effect. The application allowed us to predict macroscopic properties of materials such as: Magnetic, spectral and calorimetric as a result of physical properties of their fine electronic structure. We emphasize the importance of symmetry of charge surroundings of atom/ion, spin-orbit interactions (spin-orbit coupling) and the use of complex number matrices in the definition of the Hamiltonian. Calculation methods, algorithms and convention recalculation tools collected in ATOMIC MATTERS were chosen to permit the prediction of magnetic and spectral properties of materials in isostructural series.
Abstract: This article addresses the boundary layer flow and heat transfer of Casson fluid over a nonlinearly permeable stretching surface with chemical reaction in the presence of variable magnetic field. The effect of thermal radiation is considered to control the rate of heat transfer at the surface. Using similarity transformations, the governing partial differential equations of this problem are reduced into a set of non-linear ordinary differential equations which are solved by finite difference method. It is observed that the velocity at fixed point decreases with increasing the nonlinear stretching parameter but the temperature increases with nonlinear stretching parameter.
Abstract: Electrical conduction in a quasi-one-dimensional
polycrystalline metallic ring with a long electron phase coherence
length realized at low temperature is investigated. In this situation, the
wave nature of electrons is important in the ring, where the electrical
current I can be induced by a vector potential that arises from a static
magnetic field applied perpendicularly to the ring’s area. It is shown
that if the average grain size of the polycrystalline ring becomes
large (or comparable to the Fermi wavelength), the electrical current
I increases to ~I0, where I0 is a current in a disorder-free ring. The
cause of this increasing effect is examined, and this takes place if the
electron localization length in the polycrystalline potential increases
with increasing grain size, which gives rise to coherent connection
of tails of a localized electron wave function in the ring and thus
provides highly coherent electrical conduction.
Abstract: This paper has focused on the most important parameters in the LSC uptake; inlet Re number and Sc number in the presence of non-uniform magnetic field. The magnetic field is arising from the thin wire with electric current placed vertically to the arterial blood vessel. According to the results of this study, applying magnetic field can be a treatment for atherosclerosis by reducing LSC along the vessel wall. Homogeneous porous layer as a arterial wall has been regarded. Blood flow has been considered laminar and incompressible containing Ferro fluid (blood and 4 % vol. Fe3O4) under steady state conditions. Numerical solution of governing equations was obtained by using the single-phase model and control volume technique for flow field.
Abstract: This paper aims to analysis the behavior of DC corona
discharge in wire-to-plate electrostatic precipitators (ESP). Currentvoltage
curves are particularly analyzed. Experimental results show
that discharge current is strongly affected by the applied voltage. The proposed method of current identification is to use the method
of least squares. Least squares problems that of into two categories:
linear or ordinary least squares and non-linear least squares,
depending on whether or not the residuals are linear in all unknowns.
The linear least-squares problem occurs in statistical regression
analysis; it has a closed-form solution. A closed-form solution (or
closed form expression) is any formula that can be evaluated in a
finite number of standard operations. The non-linear problem has no
closed-form solution and is usually solved by iterative.
Abstract: This paper describes the development of a DNA-based
nanobiosensor to detect the dengue virus in mosquito using
electrically active magnetic (EAM) nanoparticles as concentrator and
electrochemical transducer. The biosensor detection encompasses
two sets of oligonucleotide probes that are specific to the dengue
virus: the detector probe labeled with the EAM nanoparticles and the
biotinylated capture probe. The DNA targets are double hybridized to
the detector and the capture probes and concentrated from
nonspecific DNA fragments by applying a magnetic field.
Subsequently, the DNA sandwiched targets (EAM-detector probe–
DNA target–capture probe-biotin) are captured on streptavidin
modified screen printed carbon electrodes through the biotinylated
capture probes. Detection is achieved electrochemically by measuring
the oxidation–reduction signal of the EAM nanoparticles. Results
indicate that the biosensor is able to detect the redox signal of the
EAM nanoparticles at dengue DNA concentrations as low as 10
ng/μl.
Abstract: Targeted drug delivery is a method of delivering
medication to a patient in a manner that increases the concentration
of the medication in some parts of the body relative to others.
Targeted drug delivery seeks to concentrate the medication in the
tissues of interest while reducing the relative concentration of the
medication in the remaining tissues. This improves efficacy of the
while reducing side effects. In the present work, we investigate the
effect of magnetic field, flow rate and particle concentration on the
capturing of magnetic particles transported in a stent implanted
fluidic channel. Iron oxide magnetic nanoparticles (Fe3O4)
nanoparticles were synthesized via co-precipitation method. The
synthesized Fe3O4 nanoparticles were added in the de-ionized (DI)
water to prepare the Fe3O4 magnetic particle suspended fluid. This
fluid is transported in a cylindrical tube of diameter 8 mm with help
of a peristaltic pump at different flow rate (25-40 ml/min). A
ferromagnetic coil of SS 430 has been implanted inside the
cylindrical tube to enhance the capturing of magnetic nanoparticles
under magnetic field. The capturing of magnetic nanoparticles was
observed at different magnetic magnetic field, flow rate and particle
concentration. It is observed that capture efficiency increases from
47-67% at magnetic field 2-5kG, respectively at particle
concentration 0.6mg/ml and at flow rate 30 ml/min. However, the
capture efficiency decreases from 65 to 44% by increasing the flow
rate from 25 to 40 ml/min, respectively. Furthermore, it is observed
that capture efficiency increases from 51 to 67% by increasing the
particle concentration from 0.3 to 0.6 mg/ml, respectively.
Abstract: In IA-MDT, the magnetic implants are placed
strategically at the target site to greatly and locally increase the
magnetic force on MDCPs and help to attract and retain the MDCPs
at the targeted region. In the present work, we develop a
mathematical model to study the capturing of magnetic nanoparticles
flowing within a fluid in an implant assisted cylindrical channel
under magnetic field. A coil of ferromagnetic SS-430 has been
implanted inside the cylindrical channel to enhance the capturing of
magnetic nanoparticles under magnetic field. The dominant magnetic
and drag forces, which significantly affect the capturing of
nanoparticles, are incorporated in the model. It is observed through
model results that capture efficiency increases as we increase the
magnetic field from 0.1 to 0.5 T, respectively. The increase in capture
efficiency by increase in magnetic field is because as the magnetic
field increases, the magnetization force, which is attractive in nature
and responsible to attract or capture the magnetic particles, increases
and results the capturing of large number of magnetic particles due to
high strength of attractive magnetic force.
Abstract: The number of persons with implanted cardiac
pacemakers (PM) has increased in Western countries. The aim of this
paper is to investigate the possible situations where persons with a
PM may be exposed to extremely low frequency (ELF) electric (EF)
and magnetic fields (MF) that may disturb their PM. Based on our
earlier studies, it is possible to find such high public exposure to EFs
only in some places near 400 kV power lines, where an EF may
disturb a PM in unipolar mode. Such EFs cannot be found near 110
kV power lines. Disturbing MFs can be found near welding
machines. However, we do not have measurement data from welding.
Based on literature and earlier studies at Tampere University of
Technology, it is difficult to find public EF or MF exposure that is
high enough to interfere with PMs.
Abstract: The Ising ferromagnet, consisting of magnetic spins, is
the simplest system showing phase transitions and critical phenomena
at finite temperatures. The Ising ferromagnet has played a central role
in our understanding of phase transitions and critical phenomena.
Also, the Ising ferromagnet explains the gas-liquid phase transitions
accurately. In particular, the Ising ferromagnet in a nonzero magnetic
field has been one of the most intriguing and outstanding unsolved
problems. We study analytically the partition function zeros in the
complex magnetic-field plane and the Yang-Lee edge singularity of
the infinite-range Ising ferromagnet in an external magnetic field.
In addition, we compare the Yang-Lee edge singularity of the
infinite-range Ising ferromagnet with that of the square-lattice Ising
ferromagnet in an external magnetic field.