Abstract: This article is trying to determine the status of flue gas
that is entering the KWH heat exchanger from combustion chamber
in order to calculate the heat transfer ratio of the heat exchanger.
Combination of measurement, calculation and computer simulation
was used to create a useful way to approximate the heat transfer rate.
The measurements were taken by a number of sensors that are
mounted on the experimental device and by a thermal imaging
camera. The results of the numerical calculation are in a good
correspondence with the real power output of the experimental
device. That result shows that the research has a good direction and
can be used to propose changes in the construction of the heat
exchanger, but still needs enhancements.
Abstract: Microbial fuel cells (MFCs) represent a promising
technology for simultaneous bioelectricity generation and wastewater
treatment. Catalysts are significant portions of the cost of microbial
fuel cell cathodes. Many materials have been tested as aqueous
cathodes, but air-cathodes are needed to avoid energy demands for
water aeration. The sluggish oxygen reduction reaction (ORR) rate at
air cathode necessitates efficient electrocatalyst such as carbon
supported platinum catalyst (Pt/C) which is very costly. Manganese
oxide (MnO2) was a representative metal oxide which has been
studied as a promising alternative electrocatalyst for ORR and has
been tested in air-cathode MFCs. However the single MnO2 has poor
electric conductivity and low stability. In the present work, the MnO2
catalyst has been modified by doping Pt nanoparticle. The goal of the
work was to improve the performance of the MFC with minimum Pt
loading. MnO2 and Pt nanoparticles were prepared by hydrothermal
and sol gel methods, respectively. Wet impregnation method was
used to synthesize Pt/MnO2 catalyst. The catalysts were further used
as cathode catalysts in air-cathode cubic MFCs, in which anaerobic
sludge was inoculated as biocatalysts and palm oil mill effluent
(POME) was used as the substrate in the anode chamber. The asprepared
Pt/MnO2 was characterized comprehensively through field
emission scanning electron microscope (FESEM), X-Ray diffraction
(XRD), X-ray photoelectron spectroscopy (XPS), and cyclic
voltammetry (CV) where its surface morphology, crystallinity,
oxidation state and electrochemical activity were examined,
respectively. XPS revealed Mn (IV) oxidation state and Pt (0)
nanoparticle metal, indicating the presence of MnO2 and Pt.
Morphology of Pt/MnO2 observed from FESEM shows that the
doping of Pt did not cause change in needle-like shape of MnO2
which provides large contacting surface area. The electrochemical
active area of the Pt/MnO2 catalysts has been increased from 276 to
617 m2/g with the increase in Pt loading from 0.2 to 0.8 wt%. The
CV results in O2 saturated neutral Na2SO4 solution showed that
MnO2 and Pt/MnO2 catalysts could catalyze ORR with different
catalytic activities. MFC with Pt/MnO2 (0.4 wt% Pt) as air cathode
catalyst generates a maximum power density of 165 mW/m3, which
is higher than that of MFC with MnO2 catalyst (95 mW/m3). The
open circuit voltage (OCV) of the MFC operated with MnO2 cathode
gradually decreased during 14 days of operation, whereas the MFC
with Pt/MnO2 cathode remained almost constant throughout the
operation suggesting the higher stability of the Pt/MnO2 catalyst.
Therefore, Pt/MnO2 with 0.4 wt% Pt successfully demonstrated as an
efficient and low cost electrocatalyst for ORR in air cathode MFC with higher electrochemical activity, stability and hence enhanced
performance.
Abstract: This paper presents a methodology using
Gravitational Search Algorithm for optimal placement of Phasor
Measurement Units (PMUs) in order to achieve complete
observability of the power system. The objective of proposed
algorithm is to minimize the total number of PMUs at the power
system buses, which in turn minimize installation cost of the PMUs.
In this algorithm, the searcher agents are collection of masses which
interact with each other using Newton’s laws of gravity and motion.
This new Gravitational Search Algorithm based method has been
applied to the IEEE 14-bus, IEEE 30-bus and IEEE 118-bus test
systems. Case studies reveal optimal number of PMUs with better
observability by proposed method.
Abstract: Operations, maintenance and reliability of wind
turbines have received much attention over the years due to the rapid
expansion of wind farms. This paper explores early fault diagnosis
technique for a 5MW wind turbine system subjected to multiple
faults, where genetic optimization algorithm is employed to make the
residual sensitive to the faults, but robust against disturbances. The
proposed technique has a potential to reduce the downtime mostly
caused by the breakdown of components and exploit the productivity
consistency by providing timely fault alarms. Simulation results show
the effectiveness of the robust fault detection methods used under
Matlab/Simulink/Gatool environment.
Abstract: The paper presents a practical three-phase PWM
inverter suitable for low voltage, low rating energy efficient systems.
The work in the paper is conducted with the view to establishing the
significance of the loss contribution from the PWM inverter in the
determination of the complete losses of a photovoltaic (PV) arraypowered
induction motor drive water pumping system. Losses
investigated include; conduction and switching loss of the devices
and gate drive losses. It is found that the PWM inverter operates at a
reasonable variable efficiency that does not fall below 92%
depending on the load. The results between the simulated and
experimental results for the system with or without a maximum
power tracker (MPT) compares very well, within an acceptable range
of 2% margin.
Abstract: Activated carbons (M4P0, M4P2, and M5P2) used in
this research were produced from palm shell and polyetherether
ketone (PEEK) via carbonization, impregnation and microwave
activation. The adsorption/desorption process was carried out using
static volumetric adsorption. Regeneration is important in the overall
economy of the process and waste minimization. This work focuses
on the thermal regeneration of the CO2 exhausted microwave
activated carbons. The regeneration strategy adopted was thermal
with nitrogen purge desorption with N2 feed flow rate of 20 ml/min
for 1 h at atmospheric pressure followed by drying at 150oC.Seven
successive adsorption/regeneration processes were carried out on the
material. It was found that after seven adsorption regeneration cycles;
the regeneration efficiency (RE) for CO2 activated carbon from palm
shell only (M4P0) was more than 90% while that of hybrid palm
shell-PEEK (M4P2, M5P2) was above 95%. The cyclic adsorption
and regeneration shows the stability of the adsorbent materials.
Abstract: Africa enjoys some of the best solar radiation levels in
the world averaging between 4-6 kWh/m2/day for most of the year
and the global economic and political conditions that tend to make
African countries more dependent on their own energy resources
have caused growing interest in renewable energy based
technologies. However to-date, implementation of modern Energy
Technologies in Africa is still very low especially the use of solar
conversion technologies. This paper presents literature review and
analysis relating to the techno-economic feasibility of solar
photovoltaic power generation in Africa. The literature is basically
classified into the following four main categories. Techno-economic
feasibility of solar photovoltaic power generation, design methods,
performance evaluations of various systems and policy of potential
future of technological development of photovoltaic (PV) in Africa
by exploring the impact of alternative policy instruments and
technology cost reductions on the financial viability of investing solar
photovoltaic in Africa.
Abstract: The thermal behavior of a large-scale, phase change material (PCM) enhanced building envelope system was studied in regard to the need for pre-fabricated construction in subtropical regions. The proposed large-scale envelope consists of a reinforced aluminum skin, insulation core, phase change material and reinforced gypsum board. The PCM impact on an energy efficiency of an enveloped room was resolved by validation of the EnergyPlus numerical scheme and optimization of a smart material location in the core. The PCM location was optimized by a minimization method of a cooling energy demand. It has been shown that there is good agreement between the test and simulation results. The optimal location of the PCM layer in Hong Kong summer conditions has been then recomputed for core thicknesses of 40, 60 and 80 mm. A non-dimensional value of the optimal PCM location was obtained to be same for all the studied cases and the considered external and internal conditions.
Abstract: This paper shows an experimental testing of a small
unit for combustion of solid fuels, such as charcoal and wood logs,
that can provide electricity. One of the concepts is that the unit does
not require qualified personnel for its operation. The unit itself is
composed of two main parts. The design requires a heat producing
stove and electricity producing thermoelectric generator. After the
construction the unit was tested and the results show that the
emission release is within the legislative requirements for emission
production and environmental protection. That qualifies such unit for
indoor application.
Abstract: This paper discusses the design and analysis of a
hybrid PV-Fuel cell energy system destined to power a DC load. The
system is composed of a photovoltaic array, a fuel cell, an
electrolyzer and a hydrogen tank. HOMER software is used in this
study to calculate the optimum capacities of the power system
components that their combination allows an efficient use of solar
resource to cover the hourly load needs. The optimal system sizing
allows establishing the right balance between the daily electrical
energy produced by the power system and the daily electrical energy
consumed by the DC load using a 28 KW PV array, a 7.5 KW fuel
cell, a 40KW electrolyzer and a 270 Kg hydrogen tank. The variation
of powers involved into the DC bus of the hybrid PV-fuel cell system
has been computed and analyzed for each hour over one year: the
output powers of the PV array and the fuel cell, the input power of
the elctrolyzer system and the DC primary load. Equally, the annual
variation of stored hydrogen produced by the electrolyzer has been
assessed. The PV array contributes in the power system with 82%
whereas the fuel cell produces 18%. 38% of the total energy
consumption belongs to the DC primary load while the rest goes to
the electrolyzer.
Abstract: Power Regeneration in Refrigeration Plant concept
has been analyzed and has been shown to be capable of saving about
25% power in Cryogenic Plants with the Power Regeneration System
(PRS) running under nominal conditions. The innovative component
Compressor Expander Group (CEG) based on turbomachinery has
been designed and built modifying CETT compressor and expander,
both selected for optimum plant performance. Experiments have
shown the good response of the turbomachines to run with R404a as
working fluid. Power saving up to 12% under PRS derated conditions
(50% loading) has been demonstrated. Such experiments allowed
predicting a power saving up to 25% under CEG full load.
Abstract: Catalytic combustion of methane is imperative due to
stability of methane at low temperature. Methane (CH4), therefore,
remains unconverted in vehicle exhausts thereby causing greenhouse
gas GHG emission problem. In this study, heterogeneous catalysts of
palladium with bio-char (2 wt% Pd/Bc) and Al2O3 (2wt% Pd/ Al2O3)
supports were prepared by incipient wetness impregnation and then
subsequently tested for catalytic combustion of CH4. Support-porous
heterogeneous catalytic combustion (HCC) material were selected
based on factors such as surface area, porosity, thermal stability,
thermal conductivity, reactivity with reactants or products, chemical
stability, catalytic activity, and catalyst life. Sustainable and
renewable support-material of bio-mass char derived from palm shell
waste material was compared with those from the conventional
support-porous materials. Kinetic rate of reaction was determined for
combustion of methane on Palladium (Pd) based catalyst with Al2O3
support and bio-char (Bc). Material characterization was done using
TGA, SEM, and BET surface area. The performance test was
accomplished using tubular quartz reactor with gas mixture ratio of
3% methane and 97% air. The methane porous-HCC conversion was
carried out using online gas analyzer connected to the reactor that
performed porous-HCC. BET surface area for prepared 2 wt% Pd/Bc
is smaller than prepared 2wt% Pd/ Al2O3 due to its low porosity
between particles. The order of catalyst activity based on kinetic rate
on reaction of catalysts in low temperature was 2wt%
Pd/Bc>calcined 2wt% Pd/ Al2O3> 2wt% Pd/ Al2O3>calcined 2wt%
Pd/Bc. Hence agro waste material can successfully be utilized as an
inexpensive catalyst support material for enhanced CH4 catalytic
combustion.
Abstract: The paper presents a thermodynamic cycle analysis
for three turboshaft engines. The first cycle is a Brayton cycle,
describing the evolution of a classical turboshaft, based on the
Klimov TV2 engine. The other four cycles aim at approaching an
Ericsson cycle, by replacing the Brayton cycle adiabatic expansion in
the turbine by quasi-isothermal expansion. The maximum quasi-
Ericsson cycles temperature is set to a lower value than the maximum
Brayton cycle temperature, equal to the Brayton cycle power turbine
inlet temperature, in order to decrease the engine NOx emissions.
Also, the power/expansion ratio distribution over the stages of the gas
generator turbine is maintained the same. In two of the considered
quasi-Ericsson cycles, the efficiencies of the gas generator turbine, as
well as the power/expansion ratio distribution over the stages of the
gas generator turbine are maintained the same as for the reference
case, while for the other two cases, the efficiencies are increased in
order to obtain the same shaft power as in the reference case. For the
two cases respecting the first condition, both the shaft power and the
thermodynamic efficiency of the engine decrease, while for the other
two, the power and efficiency are maintained, as a result of assuming
new, more efficient gas generator turbines.
Abstract: This paper shortly describes various types of biomass
and a growing number of facilities utilizing the biomass in the Czech
Republic. The considerable part of this paper deals with energy
parameters of the most frequently used types of biomass and results
of their gasification testing. Sixteen most used "Czech" woody plants
and grasses were selected; raw, element and biochemical analyses
were performed and basic calorimetric values, ash composition, and
ash characteristic temperatures were identified. Later, each biofuel
was tested in a fluidized bed gasifier. The essential part of this paper
provides results of the gasification of selected biomass types.
Operating conditions are described in detail with a focus on
individual fuels properties. Gas composition and impurities content
are also identified. In terms of operating conditions and gas quality,
the essential difference occurred mainly between woody plants and
grasses. The woody plants were evaluated as more suitable fuels for
fluidized bed gasifiers. Testing results significantly help with a
decision-making process regarding suitability of energy plants for
growing and with a selection of optimal biomass-treatment
technology.
Abstract: An innovative concept called “Flexy-Energy” is developing at 2iE. This concept aims to produce electricity at lower cost by smartly mix different available energy sources in accordance to the load profile of the region. With a higher solar irradiation and due to the fact that Diesel generator are massively used in sub-Saharan rural areas, PV/Diesel hybrid systems could be a good application of this concept and a good solution to electrify this region, provided they are reliable, cost effective and economically attractive to investors. Presentation of the developed approach is the aims of this paper. The PV/Diesel hybrid system designed consists to produce electricity and/or heat from a coupling between Diesel Diesel generators and PV panels without batteries storage, while ensuring the substitution of gasoil by bio-fuels available in the area where the system will be installed. The optimal design of this system is based on his technical performances; the Life Cycle Cost (LCC) and Levelized Cost of Energy are developed and use as economic criteria. The Net Present Value (NPV), the internal rate of return (IRR) and the discounted payback (DPB) are also evaluated according to dual electricity pricing (in sunny and unsunny hours). The PV/Diesel hybrid system obtained is compared to the standalone Diesel Diesel generators. The approach carried out in this paper has been applied to Siby village in Mali (Latitude 12 ° 23'N 8 ° 20'W) with 295 kWh as daily demand.This approach provides optimal physical characteristics (size of the components, number of component) and dynamical characteristics in real time (number of Diesel generator on, their load rate, fuel specific consumptions, and PV penetration rate) of the system. The system obtained is slightly cost effective; but could be improved with optimized tariffing strategies.
Abstract: In this paper, the exergy analysis of vapor absorption
refrigeration system using LiBr-H2O as working fluid is carried out
with the modified Gouy-Stodola approach rather than the classical
Gouy-Stodola equation and effect of varying input parameters is also
studied on the performance of the system. As the modified approach
uses the concept of effective temperature, the mathematical
expressions for effective temperature have been formulated and
calculated for each component of the system. Various constraints and
equations are used to develop program in EES to solve these
equations. The main aim of this analysis is to determine the
performance of the system and the components having major
irreversible loss. Results show that exergy destruction rate is
considerable in absorber and generator followed by evaporator and
condenser. There is an increase in exergy destruction in generator,
absorber and condenser and decrease in the evaporator by the
modified approach as compared to the conventional approach. The
value of exergy determined by the modified Gouy-Stodola equation
deviates maximum i.e. 26% in the generator as compared to the
exergy calculated by the classical Gouy-Stodola method.
Abstract: In this paper, a direct power control (DPC)
strategies have been investigated in order to control a high
power AC/DC converter with time variable load. This converter
is composed of a three level three phase neutral point clamped
(NPC) converter as rectifier and an H-bridge four quadrant
current control converter. In the high power application,
controller not only must adjust the desire outputs but also
decrease the level of distortions which are injected to the network
from the converter. Regarding to this reason and nonlinearity
of the power electronic converter, the conventional controllers
cannot achieve appropriate responses. In this research, the
precise mathematical analysis has been employed to design the
appropriate controller in order to control the time variable
load. A DPC controller has been proposed and simulated using
Matlab/ Simulink. In order to verify the simulation result, a real
time simulator- OPAL-RT- has been employed. In this paper,
the dynamic response and stability of the high power NPC
with variable load has been investigated and compared with
conventional types using a real time simulator. The results proved
that the DPC controller is more stable and has more precise
outputs in comparison with conventional controller.
Abstract: The thermal performance of a solar water heating with
1.00 m2 flat plate collectors in Cascavel - PR, is which presented in
this article, paper presents the solution to leverage the marketing of
solar heating systems through detailed constituent materials of the
solar collector studies, these abundant materials in construction, such
as expanded polyethylene, PVC, aluminum and glass tubes, mixing
them with new materials to minimize loss of efficiency while
decreasing its cost. The system was tested during months and the
collector obtained maximum recorded temperature of outlet fluid of
55°C, while the maximum temperature of the water at the bottom of
the hot water tank was 35°C. The average daily energy collected was
19.6 MJ/d; the energy supplied by the solar plate was 16.2 MJ/d; the
loss in the feed pipe was 3.2 MJ/d; the solar fraction was 32.2%, the
efficiency of the collector was 45.6% and the efficiency of the system
was 37.8%.
Abstract: Hydrothermal liquefaction (HTL) is a technique for obtaining clean biofuel from biomass in the presence of heat and pressure in an aqueous medium which leads to a decomposition of this biomass to the formation of various products. A role of operating conditions is essential for the bio-oil and other products’ yield and also quality of the products. The effects of these parameters were investigated in regards to the composition and yield of the products. Chlorellaceae microalgae were tested under different HTL conditions to clarify suitable conditions for extracting bio-oil together with value-added co-products. Firstly, different microalgae loading rates (5-30%) were tested and found that this parameter has not much significant to product yield. Therefore, 10% microalgae loading rate was selected as a proper economical solution for conditioned schedule at 250oC and 30 min-reaction time. Next, a range of temperature (210-290oC) was applied to verify the effects of each parameter by keeping the reaction time constant at 30 min. The results showed no linkage with the increase of the reaction temperature and some reactions occurred that lead to different product yields. Moreover, some nutrients found in the aqueous product are possible to be utilized for nutrient recovery.
Abstract: In this paper static scheme of under-frequency based load shedding is considered for chemical and petrochemical industries with islanded distribution networks relying heavily on the primary commodity to ensure minimum production loss, plant downtime or critical equipment shutdown. A simplistic methodology is proposed for in-house implementation of this scheme using underfrequency relays and a step by step guide is provided including the techniques to calculate maximum percentage overloads, frequency decay rates, time based frequency response and frequency based time response of the system. Case study of FFL electrical system is utilized, presenting the actual system parameters and employed load shedding settings following the similar series of steps. The arbitrary settings are then verified for worst overload conditions (loss of a generation source in this case) and comprehensive system response is then investigated.