Abstract: In North America, Most power distribution systems
employ a four-wire multi-grounded neutral (MGN) design. This paper has explained the inherent characteristics of multi-grounded three-phase four-wire distribution systems under unbalanced
situations. As a result, the mechanism of voltage swell and voltage sag in MGN feeders becomes difficult to understand. The simulation
tool that has been used in this paper is MATLAB under Windows software. In this paper the equivalent model of a full-scale multigrounded
distribution system implemented by MATLAB is
introduced. The results are expected to help utility engineers to understand the impact of MGN on distribution system operations.
Abstract: This paper deals with the current space-vector
decomposition in three-phase, three-wire systems on the basis of
some case studies. We propose four components of the current spacevector
in terms of DC and AC components of the instantaneous
active and reactive powers. The term of supplementary useless
current vector is also pointed out. The analysis shows that the current
decomposition which respects the definition of the instantaneous
apparent power vector is useful for compensation reasons only if the
supply voltages are sinusoidal. A modified definition of the
components of the current is proposed for the operation under
nonsinusoidal voltage conditions.
Abstract: This paper presents the design and analysis of a parallel
connected inverter configuration of. The configuration consists of
parallel connected three-phase dc/ac inverter. Series resistors added
to the inverter output to maintain same current in each inverter of the
two parallel inverters, and to reduce the circulating current in the
parallel inverters to the minimum. High frequency third harmonic
injection PWM (THIPWM) employed to reduce the total harmonic
distortion and to make maximum use of the voltage source. DSP was
used to generate the THIPWM and the control algorithm for the
converter. Selected experimental results have been shown to validate
the proposed system.
Abstract: Tubular linear induction motor (TLIM) can be used as a capsule pump in a large pneumatic capsule pipeline (PCP) system. Parametric performance evaluation of the designed 1-meter diameter PCP-TLIM system yields encouraging results for practical implementation. The capsule thrust and speed inside the TLIM pump can be calculated from the combination of the PCP fluid mechanics and the TLIM equations. The TLIM equivalent circuits derived from those of the conventional three-phase induction motor are used as a model to predict the static test results of a small-scale PCP-TLIM system. In this paper, additional dynamic tests are performed on the same small-scale PCP-TLIM system with two capsules of different diameters. The behaviors of the capsule inside the pump are observed and analyzed. The dynamic performances from the dynamic tests are compared with the theoretical predictions based on the TLIM equivalent circuit model.
Abstract: In a wind power generator using doubly fed induction
generator (DFIG), the three-phase pulse width modulation (PWM)
voltage source converter (VSC) is used as grid side converter (GSC)
and rotor side converter (RSC). The standard linear control laws
proposed for GSC provides not only instablity against comparatively
large-signal disturbances, but also the problem of stability due to
uncertainty of load and variations in parameters. In this paper, a
nonlinear controller is designed for grid side converter (GSC) of a
DFIG for wind power application. The nonlinear controller is
designed based on the input-output feedback linearization control
method. The resulting closed-loop system ensures a sufficient
stability region, make robust to variations in circuit parameters and
also exhibits good transient response. Computer simulations and
experimental results are presented to confirm the effectiveness of the
proposed control strategy.
Abstract: Active Power Filters (APFs) are today the most
widely used systems to eliminate harmonics compensate power
factor and correct unbalanced problems in industrial power plants.
We propose to improve the performances of conventional APFs by
using artificial neural networks (ANNs) for harmonics estimation.
This new method combines both the strategies for extracting the
three-phase reference currents for active power filters and DC link
voltage control method. The ANNs learning capabilities to
adaptively choose the power system parameters for both to compute
the reference currents and to recharge the capacitor value requested
by VDC voltage in order to ensure suitable transit of powers to
supply the inverter. To investigate the performance of this
identification method, the study has been accomplished using
simulation with the MATLAB Simulink Power System Toolbox. The
simulation study results of the new (SAPF) identification technique
compared to other similar methods are found quite satisfactory by
assuring good filtering characteristics and high system stability.
Abstract: This paper presents a fuzzy logic controlled shunt
active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a
simple method for the calculation of the reference compensation current based of Fast Fourier Transform. This presented filter is able
to operate in both balanced and unbalanced load conditions. A fuzzy
logic based current controller strategy is used to regulate the filter current and hence ensure harmonic free supply current. The validity
of the presented approach in harmonic mitigation is verified via
simulation results of the proposed test system under different loading
conditions.
Abstract: The reluctance motor is an electric motor in which
torque is produced by the tendency of its moveable part to move to a
position where the inductance of the excited winding is maximized.
In this paper switched reluctance motors (SRMs) with two different
configurations(3-phase SRM with 4rotor poles and 6 stator poles, 4-
phase SRM with 6rotor poles and 8 stator poles) is designed by
RMxprt, and performance of them is analyzed. Efficiency and torque
of SRM for different configurations in full-load condition have been
presented. The results indicate that with correct choosing of motor
applications, maximum efficiency can be found.
Abstract: In this paper we propose the study of a centrifugal pump control system driven by a three-phase induction motor, which is supplied by a PhotoVoltaic PV generator. The system includes solar panel, a DC / DC converter equipped with its MPPT control, a voltage inverter to three-phase Pulse Width Modulation - PWM and a centrifugal pump driven by a three phase induction motor. In order to control the flow of the centrifugal pump, a Direct Torque Control - DTC of the induction machine is used. To illustrate the performances of the control, simulation results are carried out using Matlab/Simulink.
Abstract: Most high-performance ac drives utilize a current
controller. The controller switches a voltage source inverter (VSI)
such that the motor current follows a set of reference current
waveforms. Fixed-band hysteresis (FBH) current control has been
widely used for the PWM inverter. We want to apply the same
controller for the PWM AC chopper. The aims of the controller is to
optimize the harmonic content at both input and output sides, while
maintaining acceptable losses in the ac chopper and to control in
wide range the fundamental output voltage. Fixed band controller has
been simulated and analyzed for a single-phase AC chopper and are
easily extended to three-phase systems. Simulation confirmed the
advantages and the excellent performance of the modulation method
applied for the AC chopper.
Abstract: Wind power is among the most actively developing distributed generation (DG) technology. Majority of the wind power based DG technologies employ wind turbine induction generators (WTIG) instead of synchronous generators, for the technical advantages like: reduced size, increased robustness, lower cost, and increased electromechanical damping. However, dynamic changes of wind speed make the amount of active/reactive power injected/drawn to a WTIG embedded distribution network highly variable. This paper analyzes the effect of wind speed changes on the active and reactive power penetration to the wind energy embedded distribution network. Four types of wind speed changes namely; constant, linear change, gust change and random change of wind speed are considered in the analysis. The study is carried out by three-phase, non-linear, dynamic simulation of distribution system component models. Results obtained from the investigation are presented and discussed.
Abstract: This study reports the preparation of soft magnetic ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213 mm and, with a thickness of approximately 22 μm 2 μm. The microstructure and magnetic properties of the ribbons were characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and electrical resistivity measurements (ERM). The amorphous material properties dependence of the cooling rate and nozzle pressure have uneven surface in ribbon thicknesses are investigated. Magnetic measurement results indicate that some region of the ribbon exhibits good magnetic properties, higher saturation induction and lower coercivity. However, due to the uneven surface of 213 mm wide ribbon, the magnetic responses are not uniformly distributed. To understand the transformer magnetic performances, this study analyzes the measurements of a three-phase 2 MVA amorphous-cored transformer. Experimental results confirm that the transformer with a ribbon width of 142 mm has better magnetic properties in terms of lower core loss, exciting power, and audible noise.
Abstract: This paper analyses the torsional efforts in gas turbine-generator shafts caused by high speed automatic reclosing of transmission lines. This issue is especially important for cases of three phase short circuit and unsuccessful reclosure of lines in the vicinity of the thermal plant. The analysis was carried out for the thermal plant TERMOPERNAMBUCO located on Northeast region of Brazil. It is shown that stress level caused by lines unsuccessful reclosing can be several times higher than terminal three-phase short circuit. Simulations were carried out with detailed shaft torsional model provided by machine manufacturer and with the “Alternative Transient Program – ATP" program [1]. Unsuccessful three phase reclosing for selected lines in the area closed to the plant indicated most critical cases. Also, reclosing first the terminal next to the gas turbine gererator will lead also to the most critical condition. Considering that the values of transient torques are very sensible to the instant of reclosing, simulation of unsuccessful reclosing with statistics ATP switch were carried out for determination of most critical transient torques for each section of the generator turbine shaft.
Abstract: This paper proposes a three-phase four-wire currentcontrolled
Voltage Source Inverter (CC-VSI) for both power quality
improvement and PV energy extraction. For power quality
improvement, the CC-VSI works as a grid current-controlling shunt
active power filter to compensate for harmonic and reactive power of
loads. Then, the PV array is coupled to the DC bus of the CC-VSI
and supplies active power to the grid. The MPPT controller employs
the particle swarm optimization technique. The output of the MPPT
controller is a DC voltage that determines the DC-bus voltage
according to PV maximum power. The PSO method is simple and
effective especially for a partially shaded PV array. From computer
simulation results, it proves that grid currents are sinusoidal and inphase
with grid voltages, while the PV maximum active power is
delivered to loads.
Abstract: The proper selection of the AC-side passive filter
interconnecting the voltage source converter to the power supply is
essential to obtain satisfactory performances of an active power filter
system. The use of the LCL-type filter has the advantage of
eliminating the high frequency switching harmonics in the current
injected into the power supply. This paper is mainly focused on
analyzing the influence of the interface filter parameters on the active
filtering performances. Some design aspects are pointed out. Thus,
the design of the AC interface filter starts from transfer functions by
imposing the filter performance which refers to the significant current
attenuation of the switching harmonics without affecting the
harmonics to be compensated. A Matlab/Simulink model of the entire
active filtering system including a concrete nonlinear load has been
developed to examine the system performances. It is shown that a
gamma LC filter could accomplish the attenuation requirement of the
current provided by converter. Moreover, the existence of an optimal
value of the grid-side inductance which minimizes the total harmonic
distortion factor of the power supply current is pointed out.
Nevertheless, a small converter-side inductance and a damping
resistance in series with the filter capacitance are absolutely needed
in order to keep the ripple and oscillations of the current at the
converter side within acceptable limits. The effect of change in the
LCL-filter parameters is evaluated. It is concluded that good active
filtering performances can be achieved with small values of the
capacitance and converter-side inductance.
Abstract: Modeling and simulation of fixed bed three-phase
catalytic reactors are considered for wet air catalytic oxidation of
phenol to perform a comparative numerical analysis between tricklebed
and packed-bubble column reactors. The modeling involves
material balances both for the catalyst particle as well as for different
fluid phases. Catalyst deactivation is also considered in a transient
reactor model to investigate the effects of various parameters
including reactor temperature on catalyst deactivation. The
simulation results indicated that packed-bubble columns were
slightly superior in performance than trickle beds. It was also found
that reaction temperature was the most effective parameter in catalyst
deactivation.
Abstract: This paper presents a novel control strategy of a threephase
four-wire Unified Power Quality (UPQC) for an improvement
in power quality. The UPQC is realized by integration of series and
shunt active power filters (APFs) sharing a common dc bus capacitor.
The shunt APF is realized using a thee-phase, four leg voltage source
inverter (VSI) and the series APF is realized using a three-phase,
three leg VSI. A control technique based on unit vector template
technique (UTT) is used to get the reference signals for series APF,
while instantaneous sequence component theory (ISCT) is used for
the control of Shunt APF. The performance of the implemented
control algorithm is evaluated in terms of power-factor correction,
load balancing, neutral source current mitigation and mitigation of
voltage and current harmonics, voltage sag and swell in a three-phase
four-wire distribution system for different combination of linear and
non-linear loads. In this proposed control scheme of UPQC, the
current/voltage control is applied over the fundamental supply
currents/voltages instead of fast changing APFs currents/voltages,
there by reducing the computational delay and the required sensors.
MATLAB/Simulink based simulations are obtained, which support
the functionality of the UPQC. MATLAB/Simulink based
simulations are obtained, which support the functionality of the
UPQC.