Abstract: The performance of an embedded grounding system is very important for the safe operation of electrical appliances and human beings. In principle, a safe grounding system has two objectives, which are to dissipate fault current without exceeding any operating and equipment limits and to ensure there is no risk of electric shock to humans in the vicinity of earthed facilities. The case studies in this paper present the calculating grounding resistance for multiple configurations of vertical and horizontally by using a simple and accurate formula. From the analytic calculated results, observed good/empirical relationship between the grounding resistance and length of the embedded grounding configurations. Moreover, the configurations of vertical and horizontal observed effectiveness of grounding resistance and good agreement on the reduction of grounding resistance values especially for vertical configuration.
Abstract: Lightning protection consists of three main parts; mainly air termination system, down conductor, and earth termination system. Earth termination system is the most important part as earth is the sink and source of charges. Therefore, even when the charges are captured and delivered to the ground, and an easy path is not provided to the charges, earth termination system would lead to problems. Soil has significantly different resistivities ranging from 10 Ωm for wet organic soil to 10000 Ωm for bedrock. Different methods have been discussed and used conventionally such as deep-ground-well method and altering the length of the rod. Those methods are not considered economical. Therefore, it was a general practice to use charcoal along with salt to reduce the soil resistivity. Bentonite is worldwide acceptable material, that had led our interest towards study of bentonite at first. It was concluded that bentonite is a clay which is non-corrosive, environment friendly. Whereas bentonite is suitable only when there is moisture present in the soil, as in the absence of moisture, cracks will appear on the surface which will provide an open passage to the air, resulting into increase in the resistivity. Furthermore, bentonite without moisture does not have enough bonding property, moisture retention, conductivity, and non-leachability. Therefore, bentonite was used along with the other backfill material to overcome the dependency of bentonite on moisture. Different experiments were performed to get the best ratio of bentonite and carbon backfill. It was concluded that properties will highly depend on the quantity of bentonite and carbon-based backfill material.
Abstract: This paper presents the measurement and simulation results by Finite Element Method (FEM) for earth resistance (RDC) for interconnected vertical ground rod configurations. The soil resistivity was measured using the Wenner four-pin Method, and RDC was measured using the Fall of Potential (FOP) method, as outlined in the standard. Genetic Algorithm (GA) is employed to interpret the soil resistivity to that of a 2-layer soil model. The same soil resistivity data that were obtained by Wenner four-pin method were used in FEM for simulation. This paper compares the results of RDC obtained by FEM simulation with the real measurement at field site. A good agreement was seen for RDC obtained by measurements and FEM. This shows that FEM is a reliable software to be used for design of earthing systems. It is also found that the parallel rod system has a better performance compared to a similar setup using a grid layout.
Abstract: This paper presents a novel statistical description of
the counterpoise effective length due to lightning surges, where the
(impulse) effective length had been obtained by means of regressive
formulas applied to the transient simulation results. The effective
length is described in terms of a statistical distribution function, from
which median, mean, variance, and other parameters of interest could
be readily obtained. The influence of lightning current amplitude,
lightning front duration, and soil resistivity on the effective length has
been accounted for, assuming statistical nature of these parameters. A
method for determining the optimal counterpoise length, in terms of
the statistical impulse effective length, is also presented. It is based on
estimating the number of dangerous events associated with lightning
strikes. Proposed statistical description and the associated method
provide valuable information which could aid the design engineer in
optimising physical lengths of counterpoises in different grounding
arrangements and soil resistivity situations.
Abstract: The prologue of new High Voltage (HV) transmission mains into the community necessitates earthing design to ensure safety compliance of the system. Concrete poles are widely used within HV transmission mains; many retired transmission mains with timber poles are being replaced with concrete ones, green transmission mains are deploying concrete poles. The earthing arrangement of the concrete poles could have an impact on the earth grid impedance also on the input impedance of the system from the fault point of view. This paper endeavors to provide information on the soil resistivity of the area and the deployments of concrete poles. It introduce the cut off soil resistivity value ρSC, this value aid in determine the impact of deploying the concrete poles on the earthing system. Multiple cases were discussed in this paper.
Abstract: Performing High Voltage (HV) tasks with a multi craft
work force create a special set of safety circumstances. This paper
aims to present vital information relating to when it is acceptable to
use a single or a two-layer soil structure. Also it discusses the
implication of the high voltage infrastructure on the earth grid and the
safety of this implication under a single or a two-layer soil structure.
A multiple case study is investigated to show the importance of using
the right soil resistivity structure during the earthing system design.
Abstract: The High Voltage (HV) transmission mains into the community necessitate earthing design to ensure safety compliance of the system. Concrete poles are widely used within HV transmission mains; which could have an impact on the earth grid impedance and input impedance of the system from the fault point of view. This paper provides information on concrete pole earthing to enhance the split factor of the system; further, it discusses the deployment of concrete structures in high soil resistivity area to reduce the earth grid system of the plant. This paper introduces the cut off soil resistivity SC ρ when replacing timber poles with concrete ones.
Abstract: High Voltage (HV) transmission lines are widely
spread around residential places. They take all forms of shapes:
concrete, steel, and timber poles. Earth grid always form part of the
HV transmission structure, whereat soil resistivity value is one of the
main inputs when it comes to determining the earth grid
requirements. In this paper, the soil structure and its implication on
the electrode resistance of HV transmission poles will be explored. In
Addition, this paper will present simulation for various soil structures
using IEEE and Australian standards to verify the computation with
CDEGS software. Furthermore, the split factor behavior under
different soil resistivity structure will be presented using CDEGS
simulations.
Abstract: The objective of this paper is to study the electrical
resistivity complexity between field and laboratory measurement, in
order to improve the effectiveness of data interpretation for
geophysical ground resistivity survey. The geological outcrop in
Penang, Malaysia with an obvious layering contact was chosen as the
study site. Two dimensional geoelectrical resistivity imaging were
used in this study to maps the resistivity distribution of subsurface,
whereas few subsurface sample were obtained for laboratory
advance. In this study, resistivity of samples in original conditions is
measured in laboratory by using time domain low-voltage technique,
particularly for granite core sample and soil resistivity measuring set
for soil sample. The experimentation results from both schemes are
studied, analyzed, calibrated and verified, including basis and
correlation, degree of tolerance and characteristics of substance.
Consequently, the significant different between both schemes is
explained comprehensively within this paper.