Abstract: In this paper, the design of a QCM sensor for liquid media measurements in vertical position is described. A rugged and low-cost proof holder has been designed, the cost of which is significantly lower than those of traditional commercial holders. The crystal is not replaceable but it can be easily cleaned. Its small volume permits to be used by dipping it in the liquid with the desired location and orientation. The developed design has been experimentally validated by measuring changes in the resonance frequency and resistance of the QCM sensor immersed vertically in different calibrated aqueous glycerol solutions. The obtained results show a great agreement with the Kanazawa theoretical expression. Consequently, the designed QCM sensor would be appropriate for sensing applications in liquids, and might take part of a future on-line multichannel low-cost QCM-based measurement system.
Abstract: In this paper, partial discharge analysis is performed in cavities artificially created in insulation. The setup is according with Cigre-II Method. Circular Samples created from Perspex Sheet with different configuration with changing number of cavities. Assessment of insulation health can be performed by Partial Discharge measurement as this has been found to be important means of condition monitoring. The experiments are done using MPD 540, which is a modern partial discharge measurement system. By analyzing the PD activity obtained for various voids/cavities, it is observed that the PD voltages show variation for cavity’s diameter, depth even for its ratios. This can be employed for scrutiny of insulation system.
Abstract: The field of instrumentation electronics is undergoing
an explosive growth, due to its wide range of applications. The
proliferation of electrical devices in a close working proximity can
negatively influence each other’s performance. The degradation in
the performance is due to electromagnetic interference (EMI). This paper investigates the negative effects of electromagnetic
interference originating in the General Purpose Interface Bus (GPIB)
control-network of the AC-DC transfer measurement system.
Remedial measures of reducing measurement errors and failure of
range of industrial devices due to EMI have been explored. The ACDC
transfer measurement system was analysed for the commonmode
(CM) EMI effects. Further investigation of coupling path as
well as much accurate identification of noise propagation mechanism
has been outlined. To prevent the occurrence of common-mode
(ground loops) which was identified between the GPIB system
control circuit and the measurement circuit, a microcontroller-driven
GPIB switching isolator device was designed, prototyped,
programmed and validated. This mitigation technique has been
explored to reduce EMI effectively.
Abstract: With a long history, dual-task has become one of the
most intriguing research fields regarding human brain functioning
and cognition. However, findings considering effects of taskinterrelations
are limited (especially, in combined motor and
cognitive tasks). Therefore, we aimed at developing a measurement
system in order to analyse interrelation effects of cognitive and motor
tasks. On the one hand, the present study demonstrates the
applicability of the measurement system and on the other hand first
results regarding a systematisation of different task combinations are
shown. Future investigations should combine imagine technologies
and this developed measurement system.
Abstract: This article describes an interesting and inexpensive laboratory experiment for undergraduate students of electronics, geography and related disciplines. The objective of the proposed experiment is to improve the students’ exposure on the basic principles of instrumentation and to demonstrate an electronic measurement system. A simple electronic curvy length measurement system is presented here. Such a system can be used to measure curvy lengths e.g. length of a river, road or railway line etc. from topographical map. The proposed system is composed of simple functional blocks which are usually demonstrated in laboratory or in theory course of electronics at the undergraduate level. The experiment is assigned to a group of students and it is found that the experiment can fulfill its objectives with high degree of satisfaction.
Abstract: This work aims to introduce an efficient and to standardize the measuring system analyses for automotive industrial. The study started by literature reviewing about the management and analyses measurement system. The approach of measuring system management, then, was constructed. Such approach was validated by collecting the current measuring system data using the equipments of interest including vernier caliper and micrometer. Their accuracy and precision of measurements were analyzed. Finally, the measuring system was improved and evaluated. The study showed that vernier did not meet its measuring characteristics based on the linearity whereas all equipments were lacking of the measuring precision characteristics. Consequently, the causes of measuring variation via the equipments of interest were declared. After the improvement, it was found that their measuring performance could be accepted as the standard required. Finally, the standardized approach for analyzing the measuring system of automotive was concluded.
Abstract: In this paper a computer system for electromagnetic
properties measurements is designed. The system employs Agilent
4294A precision impedance analyzer to measure the amplitude and
the phase of a signal applied over a tested biological tissue sample.
Measured by the developed computer system data could be used for
tissue characterization in wide frequency range from 40Hz to
110MHz. The computer system can interface with output devices
acquiring flexible testing process.
Abstract: The aim of this study was to establish the feasibility of a minute incremental exercise testing protocol in young asthma children. Twenty-two children with clinically diagnosed mild to moderate asthma volunteered to participate. The maximum incremental exercise test was performed using a cycle ergometer with an electromagnetic braking. A warm-up unloaded for 2 minutes then the workload was started at 40 watts for 2 minutes, and then stepwise increments of 8 watts per 2 minutes were applied. The pedaling frequency was set at 50 rpm. Ventilation and gas exchange were measured with a breath-by-breath automatic metabolic measurement system. Results showed that this test was well tolerated by all asthmatic children. Most of the children reached the VO2 plateau and satisfied the criteria for maximal respiratory exchange ratio of ≥ 1. This Study demonstrated that this testing protocol was suitable for young asthmatic children.
Abstract: The increasing demand for higher data rates in wireless communication systems has led to the more effective and efficient use of all allocated frequency bands. In order to use the whole bandwidth at maximum efficiency, one needs to have RF power amplifiers with a higher linear level and memory-less performance. This is considered to be a major challenge to circuit designers. In this thesis the linearity and memory are studied and examined via the behavior of the intermodulation distortion (IMD). A major source of the in-band distortion can be shown to be influenced by the out-of-band impedances presented at either the input or the output of the device, especially those impedances terminated the low frequency (IF) components. Thus, in order to regulate the in-band distortion, the out of-band distortion must be controllable. These investigations are performed on a 12W LDMOS device characterised at 2.1 GHz within a purpose built, high-power measurement system.
Abstract: In recent years, an increased competition and lower profit margins have necessitated a focus on improving the performance of the product development process, an area that traditionally have been excluded from detailed steering and evaluation. A systematic improvement requires a good understanding of the current performance, wherefore the interest for product development performance measurement has increased dramatically. This paper presents a case study that evaluates the performance of the product development performance measurement system used in a Swedish company that is a part of a global corporate group. The study is based on internal documentation and eighteen in-depth interviews with stakeholders involved in the product development process. The results from the case study includes a description of what metrics that are in use, how these are employed, and its affect on the quality of the performance measurement system. Especially, the importance of having a well-defined process proved to have a major impact on the quality of the performance measurement system in this particular case.
Abstract: In a competitive production environment, critical
decision making are based on data resulted by random sampling of
product units. Efficiency of these decisions depends on data quality
and also their reliability scale. This point leads to the necessity of a
reliable measurement system. Therefore, the conjecture process and
analysing the errors contributes to a measurement system known as
Measurement System Analysis (MSA). The aim of this research is on
determining the necessity and assurance of extensive development in
analysing measurement systems, particularly with the use of
Repeatability and Reproducibility Gages (GR&R) to improve
physical measurements. Nowadays in productive industries,
repeatability and reproducibility gages released so well but they are
not applicable as well as other measurement system analysis
methods. To get familiar with this method and gain a feedback in
improving measurement systems, this survey would be on
“ANOVA" method as the most widespread way of calculating
Repeatability and Reproducibility (R&R).
Abstract: A measurement system was successfully fabricated to
detect ion concentrations (hydrogen and chlorine) in this study.
PIC18F4520, the microcontroller was used as the control unit in the
measurement system. The measurement system was practically used
to sense the H+ and Cl- in different examples, and the pH and pCl
values were exhibited on real-time LCD display promptly. In the study,
the measurement method is used to judge whether the response voltage
is stable. The change quantity is smaller than 0.01%, that the present
response voltage compares with next response voltage for H+
measurement, and the above condition is established only 6 sec.
Besides, the change quantity is smaller than 0.01%, that the present
response voltage compares with next response voltage for Clmeasurement,
and the above condition is established only 5 sec.
Furthermore, the average error quantities would also be considered,
and they are 0.05 and 0.07 for measurements of pH and pCl values,
respectively.
Abstract: Measurement and the following evaluation of
performance represent important part of management. The paper
focuses on indicators as the basic elements of performance
measurement system. It emphasizes a necessity of searching
requirements for quality indicators so that they can become part of
the useful system. It introduces standpoints for a systematic dividing
of indicators so that they have as high as possible informative value
of background sources for searching, analysis, designing and using of
indicators. It draws attention to requirements for indicators' quality
and at the same it deals with some dangers decreasing indicator's
informative value. It submits a draft of questions that should be
answered at the construction of indicator. It is obvious that particular
indicators need to be defined exactly to stimulate the desired
behavior in order to attain expected results. In the enclosure a
concrete example of the defined indicator in the concrete conditions
of a small firm is given. The authors of the paper pay attention to the
fact that a quality indicator makes it possible to get to the basic
causes of the problem and include the established facts into the
company information system. At the same time they emphasize that
developing of a quality indicator is a prerequisite for the utilization
of the system of measurement in management.
Abstract: Logistics outsourcing is a growing trend and measuring its performance, a challenge. It must be consistent with the objectives set for logistics outsourcing, but we have found no objective-based performance measurement system. We have conducted a comprehensive review of the specialist literature to cover this gap, which has led us to identify and define these objectives. The outcome is that we have obtained a list of the most relevant objectives and their descriptions. This will enable us to analyse in a future study whether the indicators used for measuring logistics outsourcing performance are consistent with the objectives pursued with the outsourcing. If this is not the case, a proposal will be made for a set of financial and operational indicators to measure performance in logistics outsourcing that take the goals being pursued into account.
Abstract: Training with Functional Electrical Stimulation (FES)
has both physiological and psychological benefits for spinal cord
injured subjects. Commonly used methods for quantification of
spasticity have shown controversial reliability. In this study we
propose a method for quick determination of spasticity in spinal cord
injured subjects on a cycling and measurement system. 23 patients
did training sessions on an instrumented mobile FES cycle three
times a week over two months as part of their clinical rehabilitation
program. Spasticity (MAS) and the legs resistance to the pedaling
motion were assessed before and after the FES training and
measurements were done on the subjects ability to pedal with our
without motor assistance. Measurements with test persons with
incomplete spastic paraplegia have shown that spasticity is decreased
after a 30 min cycling training with functional electrical stimulation
(FES).