Abstract: Hazardous Material transportation by road is coupled
with inherent risk of accidents causing loss of lives, grievous injuries,
property losses and environmental damages. The most common type
of hazmat road accident happens to be the releases (78%) of
hazardous substances, followed by fires (28%), explosions (14%) and
vapour/ gas clouds (6 %.).
The paper is discussing initially the probable 'Impact Zones'
likely to be caused by one flammable (LPG) and one toxic (ethylene
oxide) chemicals being transported through a sizable segment of a
State Highway connecting three notified Industrial zones in Surat
district in Western India housing 26 MAH industrial units. Three
'hotspots' were identified along the highway segment depending on
the particular chemical traffic and the population distribution within
500 meters on either sides. The thermal radiation and explosion
overpressure have been calculated for LPG / Ethylene Oxide BLEVE
scenarios along with toxic release scenario for ethylene oxide.
Besides, the dispersion calculations for ethylene oxide toxic release
have been made for each 'hotspot' location and the impact zones
have been mapped for the LOC concentrations. Subsequently, the
maximum Initial Isolation and the protective zones were calculated
based on ERPG-3 and ERPG-2 values of ethylene oxide respectively
which are estimated taking the worst case scenario under worst
weather conditions. The data analysis will be helpful to the local
administration in capacity building with respect to rescue /
evacuation and medical preparedness and quantitative inputs to
augment the District Offsite Emergency Plan document.
Abstract: IP multicasting is a key technology for many existing and emerging applications on the Internet. Furthermore, with increasing popularity of wireless devices and mobile equipment, it is necessary to determine the best way to provide this service in a wireless environment. IETF Mobile IP, that provides mobility for hosts in IP networks, proposes two approaches for mobile multicasting, namely, remote subscription (MIP-RS) and bi-directional tunneling (MIP-BT). In MIP-RS, a mobile host re-subscribes to the multicast groups each time it moves to a new foreign network. MIP-RS suffers from serious packet losses while mobile host handoff occurs. In MIP-BT, mobile hosts send and receive multicast packets by way of their home agents (HAs), using Mobile IP tunnels. Therefore, it suffers from inefficient routing and wastage of system resources. In this paper, we propose a protocol called Mobile Multicast support using Old Foreign Agent (MMOFA) for Mobile Hosts. MMOFA is derived from MIP-RS and with the assistance of Mobile host's Old foreign agent, routes the missing datagrams due to handoff in adjacent network via tunneling. Also, we studied the performance of the proposed protocol by simulation under ns-2.27. The results demonstrate that MMOFA has optimal routing efficiency and low delivery cost, as compared to other approaches.
Abstract: This paper presents image compression with wavelet based method. The wavelet transformation divides image to low- and high pass filtered parts. The traditional JPEG compression technique requires lower computation power with feasible losses, when only compression is needed. However, there is obvious need for wavelet based methods in certain circumstances. The methods are intended to the applications in which the image analyzing is done parallel with compression. Furthermore, high frequency bands can be used to detect changes or edges. Wavelets enable hierarchical analysis for low pass filtered sub-images. The first analysis can be done for a small image, and only if any interesting is found, the whole image is processed or reconstructed.
Abstract: Detection of incipient abnormal events is important to
improve safety and reliability of machine operations and reduce losses
caused by failures. Improper set-ups or aligning of parts often leads to
severe problems in many machines. The construction of prediction
models for predicting faulty conditions is quite essential in making
decisions on when to perform machine maintenance. This paper
presents a multivariate calibration monitoring approach based on the
statistical analysis of machine measurement data. The calibration
model is used to predict two faulty conditions from historical reference
data. This approach utilizes genetic algorithms (GA) based variable
selection, and we evaluate the predictive performance of several
prediction methods using real data. The results shows that the
calibration model based on supervised probabilistic principal
component analysis (SPPCA) yielded best performance in this work.
By adopting a proper variable selection scheme in calibration models,
the prediction performance can be improved by excluding
non-informative variables from their model building steps.
Abstract: This paper undertakes the problem of optimal
capacitor placement in a distribution system. The problem is how to
optimally determine the locations to install capacitors, the types and
sizes of capacitors to he installed and, during each load level,the
control settings of these capacitors in order that a desired objective
function is minimized while the load constraints,network constraints
and operational constraints (e.g. voltage profile) at different load
levels are satisfied. The problem is formulated as a combinatorial
optimization problem with a nondifferentiable objective function.
Four solution mythologies based on algorithms (GA),tabu search
(TS), and hybrid GA-SA algorithms are presented.The solution
methodologies are preceded by a sensitivity analysis to select the
candidate capacitor installation locations.
Abstract: Optimal reactive power flow is an optimization problem
with one or more objective of minimizing the active power losses for
fixed generation schedule. The control variables are generator bus
voltages, transformer tap settings and reactive power output of the
compensating devices placed on different bus bars. Biogeography-
Based Optimization (BBO) technique has been applied to solve
different kinds of optimal reactive power flow problems subject
to operational constraints like power balance constraint, line flow
and bus voltages limits etc. BBO searches for the global optimum
mainly through two steps: Migration and Mutation. In the present
work, BBO has been applied to solve the optimal reactive power
flow problems on IEEE 30-bus and standard IEEE 57-bus power
systems for minimization of active power loss. The superiority of the
proposed method has been demonstrated. Considering the quality of
the solution obtained, the proposed method seems to be a promising
one for solving these problems.
Abstract: The major part of light weight timber constructions
consists of insulation. Mineral wool is the most commonly used
insulation due to its cost efficiency and easy handling. The fiber
orientation and porosity of this insulation material enables flowthrough.
The air flow resistance is low. If leakage occurs in the
insulated bay section, the convective flow may cause energy losses
and infiltration of the exterior wall with moisture and particles. In
particular the infiltrated moisture may lead to thermal bridges and
growth of health endangering mould and mildew. In order to prevent
this problem, different numerical calculation models have been
developed. All models developed so far have a potential for
completion. The implementation of the flow-through properties of
mineral wool insulation may help to improve the existing models.
Assuming that the real pressure difference between interior and
exterior surface is larger than the prescribed pressure difference in the
standard test procedure for mineral wool ISO 9053 / EN 29053,
measurements were performed using the measurement setup for
research on convective moisture transfer “MSRCMT".
These measurements show, that structural inhomogeneities of
mineral wool effect the permeability only at higher pressure
differences, as applied in MSRCMT. Additional microscopic
investigations show, that the location of a leak within the
construction has a crucial influence on the air flow-through and the
infiltration rate. The results clearly indicate that the empirical values
for the acoustic resistance of mineral wool should not be used for the
calculation of convective transfer mechanisms.
Abstract: Power loss reduction is one of the main targets in power industry and so in this paper, the problem of finding the optimal configuration of a radial distribution system for loss reduction is considered. Optimal reconfiguration involves the selection of the best set of branches to be opened ,one each from each loop, for reducing resistive line losses , and reliving overloads on feeders by shifting the load to adjacent feeders. However ,since there are many candidate switching combinations in the system ,the feeder reconfiguration is a complicated problem. In this paper a new approach is proposed based on a simple optimum loss calculation by determining optimal trees of the given network. From graph theory a distribution network can be represented with a graph that consists a set of nodes and branches. In fact this problem can be viewed as a problem of determining an optimal tree of the graph which simultaneously ensure radial structure of each candidate topology .In this method the refined genetic algorithm is also set up and some improvements of algorithm are made on chromosome coding. In this paper an implementation of the algorithm presented by [7] is applied by modifying in load flow program and a comparison of this method with the proposed method is employed. In [7] an algorithm is proposed that the choice of the switches to be opened is based on simple heuristic rules. This algorithm reduce the number of load flow runs and also reduce the switching combinations to a fewer number and gives the optimum solution. To demonstrate the validity of these methods computer simulations with PSAT and MATLAB programs are carried out on 33-bus test system. The results show that the performance of the proposed method is better than [7] method and also other methods.
Abstract: The purpose of this work is fast design optimization of
the seal chamber. The study includes the mass transfer between lower
and upper chamber on seal chamber for hot water application pumps.
The use of Fluent 12.1 commercial code made it possible to capture
complex flow with heat-mass transfer, radiation, Tailor instability,
and buoyancy effect. Realizable k-epsilon model was used for
turbulence modeling. Radiation heat losses were taken into account.
The temperature distribution at seal region is predicted with respect
to heat addition.
Results show the possibilities of the model simplifications by
excluding the water domain in low chamber from calculations. CFD
simulations permit to improve seal chamber design to meet target
water temperature around the seal. This study can be used for the
analysis of different seal chamber configurations.
Abstract: This paper presents a method for the optimal
allocation of Distributed generation in distribution systems. In this
paper, our aim would be optimal distributed generation allocation for
voltage profile improvement and loss reduction in distribution
network. Genetic Algorithm (GA) was used as the solving tool,
which referring two determined aim; the problem is defined and
objective function is introduced. Considering to fitness values
sensitivity in genetic algorithm process, there is needed to apply load
flow for decision-making. Load flow algorithm is combined
appropriately with GA, till access to acceptable results of this
operation. We used MATPOWER package for load flow algorithm
and composed it with our Genetic Algorithm. The suggested method
is programmed under MATLAB software and applied ETAP
software for evaluating of results correctness. It was implemented on
part of Tehran electricity distributing grid. The resulting operation of
this method on some testing system is illuminated improvement of
voltage profile and loss reduction indexes.
Abstract: The excellent suitability of the externally excited synchronous
machine (EESM) in automotive traction drive applications
is justified by its high efficiency over the whole operation range and
the high availability of materials. Usually, maximum efficiency is
obtained by modelling each single loss and minimizing the sum of all
losses. As a result, the quality of the optimization highly depends on
the precision of the model. Moreover, it requires accurate knowledge
of the saturation dependent machine inductances. Therefore, the
present contribution proposes a method to minimize the overall losses
of a salient pole EESM and its inverter in steady state operation based
on measurement data only. Since this method does not require any
manufacturer data, it is well suited for an automated measurement
data evaluation and inverter parametrization. The field oriented control
(FOC) of an EESM provides three current components resp. three
degrees of freedom (DOF). An analytic minimization of the copper
losses in the stator and the rotor (assuming constant inductances) is
performed and serves as a first approximation of how to choose the
optimal current reference values. After a numeric offline minimization
of the overall losses based on measurement data the results are
compared to a control strategy that satisfies cos (ϕ) = 1.
Abstract: An improved topology of a voltage-fed quasi-resonant
soft switching LCrCdc series-parallel half bridge inverter with a constant-frequency for electronic ballast applications is proposed in this paper. This new topology introduces a low-cost solution to
reduce switching losses and circuit rating to achieve high-efficiency
ballast. Switching losses effect on ballast efficiency is discussed
through experimental point of view. In this discussion, an improved
topology in which accomplishes soft switching operation over a wide
power regulation range is proposed. The proposed structure uses reverse recovery diode to provide better operation for the ballast system. A symmetrical pulse wide modulation (PWM) control scheme is implemented to regulate a wide range of out-put power.
Simulation results are kindly verified with the experimental
measurements obtained by ballast-lamp laboratory prototype. Different load conditions are provided in order to clarify the
performance of the proposed converter.
Abstract: In switch mode power inverters, small sized inverters
can be obtained by increasing the switching frequency. Switching
frequency increment causes high driver losses. Also, high dt
di
and
dt
dv
produced by the switching action creates high Electromagnetic
Interference (EMI) and Radio Frequency Interference (RFI). In this
paper, a series half bridge series resonant inverter circuit is simulated
and evaluated practically to demonstrate the turn-on and turn-off
conditions during zero or close to zero voltage switching. Also, the
reverse recovery current effects of the body diode of the MOSFETs
were investigated by operating above and below resonant frequency.
Abstract: Solar Cells are destined to supply electric energy beginning from primary resources. It can charge a battery up to 12V dc. For residential use an inverter for 12V dc to 220Vac conversion is desired. For this a static DC-AC converter is necessarily inserted between the solar cells and the distribution network. This paper describes a new P.W.M. strategy for a voltage source inverter. This modulation strategy reduces the energy losses and harmonics in the P.W.M. voltage source inverter. This technique allows the P.W.M. voltage source inverter to become a new feasible solution for solar home application.
Abstract: Losses reduction initiatives in distribution systems
have been activated due to the increasing cost of supplying
electricity, the shortage in fuel with ever-increasing cost to produce
more power, and the global warming concerns. These initiatives have
been introduced to the utilities in shape of incentives and penalties.
Recently, the electricity distribution companies in Oman have been
incentivized to reduce the distribution technical and non-technical
losses with an equal annual reduction rate for 6 years. In this paper,
different techniques for losses reduction in Mazoon Electricity
Company (MZEC) are addressed. In this company, high numbers of
substation and feeders were found to be non-compliant with the
Distribution System Security Standard (DSSS). Therefore, 33
projects have been suggested to bring non-complying 29 substations
and 28 feeders to meet the planed criteria and to comply with the
DSSS. The largest part of MZEC-s network (South Batinah region)
was modeled by ETAP software package. The model has been
extended to implement the proposed projects and to examine their
effects on losses reduction. Simulation results have shown that the
implementation of these projects leads to a significant improvement
in voltage profile, and reduction in the active and the reactive power
losses. Finally, the economical analysis has revealed that the
implementation of the proposed projects in MZEC leads to an annual
saving of about US$ 5 million.
Abstract: An Artificial Neural Network based modeling
technique has been used to study the influence of different
combinations of meteorological parameters on evaporation from a
reservoir. The data set used is taken from an earlier reported study.
Several input combination were tried so as to find out the importance
of different input parameters in predicting the evaporation. The
prediction accuracy of Artificial Neural Network has also been
compared with the accuracy of linear regression for predicting
evaporation. The comparison demonstrated superior performance of
Artificial Neural Network over linear regression approach. The
findings of the study also revealed the requirement of all input
parameters considered together, instead of individual parameters
taken one at a time as reported in earlier studies, in predicting the
evaporation. The highest correlation coefficient (0.960) along with
lowest root mean square error (0.865) was obtained with the input
combination of air temperature, wind speed, sunshine hours and
mean relative humidity. A graph between the actual and predicted
values of evaporation suggests that most of the values lie within a
scatter of ±15% with all input parameters. The findings of this study
suggest the usefulness of ANN technique in predicting the
evaporation losses from reservoirs.
Abstract: In this paper the authors propose a flexible electronic solution, to improve the energetic efficiency of a thermo plant. This is achieved by replacing the mechanical gear box, placed traditionally between a gas turbine and a synchronous generator; by a power electronic converter. After reminding problematic of gear boxes and interest of a proposed electronic solution in high power plants, the authors describe a new control strategy for an indirect frequency converter, which is characterized by its high efficiency due to the use of SWM: Square Wave Modulation. The main advantage of this mode is the quasi absence of switching losses. A control method is also proposed to resolve some problems incurred by using square wave modulation, in particular to reduce the harmonics distortion of the output inverter voltage and current. Simulation examples as well as experimental results are included.
Abstract: Distributed Power generation has gained a lot of
attention in recent times due to constraints associated with
conventional power generation and new advancements in DG
technologies .The need to operate the power system economically
and with optimum levels of reliability has further led to an increase
in interest in Distributed Generation. However it is important to place
Distributed Generator on an optimum location so that the purpose of
loss minimization and voltage regulation is dully served on the
feeder. This paper investigates the impact of DG units installation on
electric losses, reliability and voltage profile of distribution networks.
In this paper, our aim would be to find optimal distributed
generation allocation for loss reduction subjected to constraint of
voltage regulation in distribution network. The system is further
analyzed for increased levels of Reliability. Distributed Generator
offers the additional advantage of increase in reliability levels as
suggested by the improvements in various reliability indices such as
SAIDI, CAIDI and AENS. Comparative studies are performed and
related results are addressed. An analytical technique is used in order
to find the optimal location of Distributed Generator. The suggested
technique is programmed under MATLAB software. The results
clearly indicate that DG can reduce the electrical line loss while
simultaneously improving the reliability of the system.
Abstract: Natural gas is the most popular fossil fuel in the
current era and future as well. Natural gas is existed in underground
reservoirs so it may contain many of non-hydrocarbon components
for instance, hydrogen sulfide, nitrogen and water vapor. These
impurities are undesirable compounds and cause several technical
problems for example, corrosion and environment pollution.
Therefore, these impurities should be reduce or removed from natural
gas stream. Khurmala dome is located in southwest Erbil-Kurdistan
region. The Kurdistan region government has paid great attention for
this dome to provide the fuel for Kurdistan region. However, the
Khurmala associated natural gas is currently flaring at the field.
Moreover, nowadays there is a plan to recover and trade this gas and
to use it either as feedstock to power station or to sell it in global
market. However, the laboratory analysis has showed that the
Khurmala sour gas has huge quantities of H2S about (5.3%) and CO2
about (4.4%). Indeed, Khurmala gas sweetening process has been
removed in previous study by using Aspen HYSYS. However,
Khurmala sweet gas still contents some quintets of water about 23
ppm in sweet gas stream. This amount of water should be removed or
reduced. Indeed, water content in natural gas cause several technical
problems such as hydrates and corrosion. Therefore, this study aims
to simulate the prospective Khurmala gas dehydration process by
using Aspen HYSYS V. 7.3 program. Moreover, the simulation
process succeeded in reducing the water content to less than 0.1ppm.
In addition, the simulation work is also achieved process
optimization by using several desiccant types for example, TEG and
DEG and it also study the relationship between absorbents type and
its circulation rate with HCs losses from glycol regenerator tower.
Abstract: The Portuguese Constitution, in article 22, instituted
the general principle of tort liability of the State and other public law
entities.
Consequently, ordinary legislation established the tort liability of
the State into the Portuguese Legal Order, by means of Decree-Law
48051, of 1967.
This decree, which was criticised extensively, was amended by
virtue of Law 67/2007, of 31st December, establishing the regime for
tort liability arising from losses caused by third parties, due to the
acts of public management in relation to all the functions of the State,
i.e. i) administrative, ii) legislative, and iii) jurisdictional.