Abstract: With the advocacy of green transportation and green traveling, cycling has become increasingly popular nowadays. Physiology and bike design are key factors for the influence of cycling efficiency. Therefore, this study aimed to investigate the significance of bike-frame geometric factors on cycling efficiency and muscle activation for different body sizes of non-professional Asian male cyclists. Participants who represented various body sizes, as measured by leg and back lengths, carried out cycling tests using a tailor-assembled road bike with different ergonomic design configurations including seat-height adjustments (i.e., 96%, 100%, and 104% of trochanteric height) and bike frame sizes (i.e., small and medium frames) for an assessable distance of 1 km. A specific power meter and self-developed adaptable surface electromyography (sEMG) were used to measure average pedaling power and cadence generated and muscle activation, respectively. The results showed that changing the seat height was far more significant than the body and bike frame sizes. The sEMG data evidently provided a better understanding of muscle activation as a function of different seat heights. Therefore, the interpretation of this study is that the major bike ergonomic design factor dominating the cycling efficiency of Asian participants with different body sizes was the seat height.
Abstract: After Yogyakarta earthquake in 2006, the main problem that occurred in the first yard of Prambanan Temple is ponding area that occurred after rainfall. Soil characterization needs to be determined by conducting several processes, especially permeability coefficient (k) in both saturated and unsaturated conditions to solve this problem. More accurate and efficient field testing procedure is required to obtain permeability data that present the field condition. One of the field permeability test equipment is Constant Discharge procedure to determine the permeability coefficient. Necessary adjustments of the Constant Discharge procedure are needed to be determined especially the value of geometric factor (F) to improve the corresponding value of permeability coefficient. The value of k will be correlated with the value of volumetric water content (θ) of an unsaturated condition until saturated condition. The principle procedure of Constant Discharge model provides a constant flow in permeameter tube that flows into the ground until the water level in the tube becomes constant. Constant water level in the tube is highly dependent on the tube dimension. Every tube dimension has a shape factor called the geometric factor that affects the result of the test. Geometric factor value is defined as the characteristic of shape and radius of the tube. This research has modified the geometric factor parameters by using empty material tube method so that the geometric factor will change. Saturation level is monitored by using soil moisture sensor. The field test results were compared with the results of laboratory tests to validate the results of the test. Field and laboratory test results of empty tube material method have an average difference of 3.33 x 10-4 cm/sec. The test results showed that modified geometric factor provides more accurate data. The improved methods of constant discharge procedure provide more relevant results.
Abstract: Speckle phenomena results from when coherent
radiation is reflected from a rough surface. Characterizing the speckle
strongly depends on the measurement condition and experimental
setup. In this paper we report the experimental results produced with
different parameters in the setup. We investigated the factors which
affects the speckle contrast, such as, F-number, gamma value and
exposure time of the camera, rather than geometric factors like the
distance between the projector lens to the screen, the viewing distance,
etc. The measurement results show that the speckle contrast decreases
by decreasing F-number, by increasing gamma value, and slightly
affects by exposure time of the camera and the gain value of the
camera.
Abstract: Soil organic carbon (SOC) plays a key role in soil
fertility, hydrology, contaminants control and acts as a sink or source
of terrestrial carbon content that can affect the concentration of
atmospheric CO2. SOC supports the sustainability and quality of
ecosystems, especially in semi-arid region. This study was
conducted to determine relative importance of 13 different
exploratory climatic, soil and geometric factors on the SOC contents
in one of the semiarid watershed zones in Iran. Two methods
canonical discriminate analysis (CDA) and feed-forward back
propagation neural networks were used to predict SOC. Stepwise
regression and sensitivity analysis were performed to identify
relative importance of exploratory variables. Results from sensitivity
analysis showed that 7-2-1 neural networks and 5 inputs in CDA
models output have highest predictive ability that explains %70 and
%65 of SOC variability. Since neural network models outperformed
CDA model, it should be preferred for estimating SOC.