Abstract: The new design of heat exchangers utilizing an
annular distributor opens a new gateway for realizing higher energy
optimization. To realize this goal, graphene nanoplatelet-based water
nanofluids with promising thermophysical properties were
synthesized in the presence of covalent and noncovalent
functionalization. Thermal conductivity, density, viscosity and
specific heat capacity were investigated and employed as a raw data
for ANSYS-Fluent to be used in two-phase approach. After
validation of obtained results by analytical equations, two special
parameters of convective heat transfer coefficient and pressure drop
were investigated. The study followed by studying other heat transfer
parameters of annular pass in the presence of graphene nanopletelesbased
water nanofluids at different weight concentrations, input
powers and temperatures. As a result, heat transfer performance and
friction loss are predicted for both synthesized nanofluids.
Abstract: Unsteady flow and heat transfer from a circular
cylinder in cross-flow is studied numerically. The governing
equations are solved by using finite volume method. Reynolds
number varies in range of 50 to 200; in this range flow is considered
to be laminar and unsteady. Al2O3 nanoparticle with volume fraction
in range of 5% to 20% is added to pure water. Effects of adding
nanoparticle to pure water on lift and drag coefficient and Nusselt
number is presented. Addition of Al2O3 has inconsiderable effect on
the value of drags and lift coefficient. However, it has significant
effect on heat transfer; results show that heat transfer of Al2O3
nanofluid is about 9% to 36% higher than pure water.
Abstract: This paper analyses the unsteady, two-dimensional
stagnation point flow of an incompressible viscous fluid over a flat
sheet when the flow is started impulsively from rest and at the same
time, the sheet is suddenly stretched in its own plane with a velocity
proportional to the distance from the stagnation point. The partial
differential equations governing the laminar boundary layer forced
convection flow are non-dimensionalised using semi-similar
transformations and then solved numerically using an implicit finitedifference
scheme known as the Keller-box method. Results
pertaining to the flow and heat transfer characteristics are computed
for all dimensionless time, uniformly valid in the whole spatial region
without any numerical difficulties. Analytical solutions are also
obtained for both small and large times, respectively representing the
initial unsteady and final steady state flow and heat transfer.
Numerical results indicate that the velocity ratio parameter is found
to have a significant effect on skin friction and heat transfer rate at
the surface. Furthermore, it is exposed that there is a smooth
transition from the initial unsteady state flow (small time solution) to
the final steady state (large time solution).
Abstract: In research on natural ventilation, and passive cooling
with forced convection, is essential to know how heat flows in a solid
object and the pattern of temperature distribution on their surfaces,
and eventually how air flows through and convects heat from the
surfaces of steel under roof. This paper presents some results from
running the computational fluid dynamic program (CFD) by
comparison between natural ventilation and forced convection within
roof attic that is received directly from solar radiation. The CFD
program for modeling air flow inside roof attic has been modified to
allow as two cases. First case, the analysis under natural ventilation,
is closed area in roof attic and second case, the analysis under forced
convection, is opened area in roof attic. These extend of all cases to
available predictions of variations such as temperature, pressure, and
mass flow rate distributions in each case within roof attic. The
comparison shows that this CFD program is an effective model for
predicting air flow of temperature and heat transfer coefficient
distribution within roof attic. The result shows that forced convection
can help to reduce heat transfer through roof attic and an around area
of steel core has temperature inner zone lower than natural
ventilation type. The different temperature on the steel core of roof
attic of two cases was 10-15 oK.