Abstract: Cavitation is one of the most well-known process faults that may occur in different industrial equipment especially centrifugal pumps. Cavitation also may happen in water pumps and turbines. Sometimes cavitation has been severe enough to wear holes in the impeller and damage the vanes to such a degree that the impeller becomes very ineffective. More commonly, the pump efficiency will decrease significantly during cavitation and continue to decrease as damage to the impeller increases. Typically, when cavitation occurs, an audible sound similar to ‘marbles’ or ‘crackling’ is reported to be emitted from the pump. In this paper, the most effective monitoring items and techniques in detecting cavitation discussed in details. Besides, some successful solutions for solving this problem for sea water vertical Centrifugal lift Pump discussed through a case history related to Iran oil industry. Furthermore, balance line modification, strainer choking and random resonance in sea water pumps discussed. In addition, a new Method for diagnosing mechanical conditions of sea water vertical Centrifugal lift Pumps introduced. This method involves disaggregating bus current by device into disaggregated currents having correspondences with operating currents in response to measured bus current. Moreover, some new patents and innovations in mechanical sea water pumping and cooling systems discussed in this paper.
Abstract: Adsorption refrigeration working pair is a vital and is the main component in the adsorption refrigeration machine. Therefore the development key is laying on the adsorption pair that leads to the improvement of the adsorption refrigeration machine. In this study the state-of-the-art in the application of the adsorption refrigeration working pairs in both classical and modern adsorption pairs are presented, compared and summarized. It is found that the maximum adsorption capacity for the classical working pairs was 0.259kg/kg for activated carbon/methanol and that for the modern working pairs was 2kg/kg for maxsorb III/R-134a. The study concluded that, the performances of the adsorption working pairs of adsorption cooling systems are still need further investigations as well as developing adsorption pairs having higher sorption capacity with low or no impact on environmental, to build compact, efficient, reliable and long life performance adsorption chillier. Also, future researches need to be focused on designing the adsorption system that provide efficient heating and cooling for the adsorbent materials through distributing the adsorbent material over heat exchanger surface, to allow good heat and mass transfer between the adsorbent and the refrigerant.
Abstract: In space during functioning, a satellite will be heated
up due to the behavior of its components such as power electronics.
In order to prevent problems in the satellite, this heat has to be
released in space thanks to the cooling system. This system consists
of a loop heat pipe (LHP), in which a fluid streams through an
evaporator and a condenser. In the evaporator, the fluid captures the
heat from the satellite and evaporates. Then it flows to the condenser
where it releases the heat and it condenses. In this project, the two
mains parts of a cooling system are studied: the evaporator and the
condenser. The study of the diphasic loop was done starting from
digital simulations carried out under Matlab and Femlab.
Abstract: Cooling with sound is a physical phenomenon allowed by Thermo-Acoustics in which acoustic energy is transformed into a negative heat transfer, in other words: into cooling! Without needing any harmful gas, the transformation is environmentally friendly and can respond to many needs in terms of air conditioning, food refrigeration for domestic use, and cooling medical samples for example. To explore the possibilities of this cooling solution on a small scale, the TACS prototype has been designed, consisting of a low cost thermoacoustic refrigerant “pipe” able to lower the temperature by a few degrees. The obtained results are providing an interesting element for possible future of thermo-acoustic refrigeration.
Abstract: Polymerase chain reaction (PCR) assay and
conventional microbiological methods were used to detect bacterial
contamination of egg shells and egg content in different commercial
housing systems, open house system and evaporative cooling system.
A PCR assay was developed for direct detection using a set of
primers specific for the invasion by A gene (invA) of Salmonella spp.
PCR detected the presence of Salmonella in 2 samples of shell egg
from the evaporative cooling system, while conventional cultural
methods detected no Salmonella from the same samples.
Abstract: Air conditioning systems of houses consume large
quantity of electricity. To reducing energy consumption for air
conditioning purposes it is becoming attractive the use of evaporative
cooling air conditioning which is less energy consuming compared to
air chillers. But, it is obvious that higher energy efficiency of
evaporative cooling is not enough to judge whether evaporative
cooling economically is competitive with other types of cooling
systems. To proving the higher energy efficiency and cost
effectiveness of the evaporative cooling competitive analysis of
various types of cooling system should be accomplished. For noted
purpose optimization mathematical model for each system should be
composed based on system approach analysis. In this paper different
types of evaporative cooling-heating systems are discussed and
methods for increasing their energy efficiency and as well as
determining of their design parameters are developed. The
optimization mathematical models for each of them are composed
with help of which least specific costs for each of them are reviled.
The comparison of specific costs proved that the most efficient and
cost effective is considered the “direct evaporating" system if it is
applicable for given climatic conditions. Next more universal and
applicable for many climatic conditions system providing least cost
of heating and cooling is considered the “direct evaporating" system.
Abstract: This research aimed to modify pineapple leaf paper
(PALP) for using as wet media in the evaporation cooling system by
improving wet mechanical property (tensile strength) without
compromising water absorption property. Polyamideamineepichorohydrin
resin (PAE) and carboxymethylcellulose (CMC)
were used to strengthen the paper, and the PAE and CMC ratio of
80:20 showed the optimum wet and dry tensile index values, which
were higher than those of the commercial cooling pad (CCP).
Compared with CCP, PALP itself and all the PAE/CMC modified
PALP possessed better water absorption. The PAE/CMC modified
PALP had potential to become a new type of wet media.
Abstract: wind catchers have been served as a cooling system, used to provide acceptable ventilation by means of renewable energy of wind. In the present study, the city of Yazd in arid climate is selected as case study. From the architecture point of view, learning about wind catchers in this study is done by means of field surveys. Research method for selection of the case is based on random form, and analytical method. Wind catcher typology and knowledge of relationship governing the wind catcher's architecture were those measures that are taken for the first time. 53 wind catchers were analyzed. The typology of the wind-catchers is done by the physical analyzing, patterns and common concepts as incorporated in them. How the architecture of wind catcher can influence their operations by analyzing thermal behavior are the archetypes of selected wind catchers. Calculating fluids dynamics science, fluent software and numerical analysis are used in this study as the most accurate analytical approach. The results obtained from these analyses show the formal specifications of wind catchers with optimum operation in Yazd. The knowledge obtained from the optimum model could be used for design and construction of wind catchers with more improved operation
Abstract: In this paper, the steady-state temperature of a sample 500 KW two rotor one stator Non-slotted axial flux permanent magnet motor is calculated using the finite element simulator software package. Due to the high temperature in various parts of the machine, especially at stator winding, a cooling system is designed for the motor and the temperature is recalculated. The results show that the temperature obtained for the parts is within the permissible range.
Abstract: In this paper, a new cooling system using a nacelle duct
is proposed for the mechanical room in the household refrigerator. The
conventional mechanical room consists of a condenser, a compressor
and an axial fan. The axial fan is mainly responsible for cooling the
condenser and the compressor. The new cooling system is developed
by replacing the axial fan with the nacelle duct including the small
centrifugal fan. The parametric study is carried out to find the optimum
designs of the nacelle duct in terms of performance and efficiency.
Through this study, it is revealed that the new system can reduce the
space, electrical power and noise compared with the conventional
system
Abstract: The steady-state temperature for one-dimensional transpiration cooling system has been conducted experimentally and numerically to investigate the heat transfer characteristics of combined convection and radiation. The Nickel –Chrome (Ni-Cr) open-cellular porous material having porosity of 0.93 and pores per inch (PPI) of 21.5 was examined. The upper surface of porous plate was heated by the heat flux of incoming radiation varying from 7.7 - 16.6 kW/m2 whereas air injection velocity fed into the lower surface was varied from 0.36 - 1.27 m/s, and was then rearranged as Reynolds number (Re). For the report of the results in the present study, two efficiencies including of temperature and conversion efficiency were presented. Temperature efficiency indicating how close the mean temperature of a porous heat plate to that of inlet air, and increased rapidly with the air injection velocity (Re). It was then saturated and had a constant value at Re higher than 10. The conversion efficiency, which was regarded as the ability of porous material in transferring energy by convection after absorbed from heat radiation, decreased with increasing of the heat flux and air injection velocity. In addition, it was then asymptotic to a constant value at the Re higher than 10. The numerical predictions also agreed with experimental data very well.
Abstract: In this paper, the feasibility study of using a hybrid
system of ground heat exchangers (GHE) and direct evaporative
cooling system in arid weather condition has been performed. The
model is applied for Yazd and Kerman, two cities with arid weather
condition in Iran. The system composed of three sections: Ground-
Coupled-Circuit (GCC), Direct Evaporative Cooler (DEC) and
Cooling Coil Unite (CCU). The GCC provides the necessary precooling
for DEC. The GCC includes four vertical GHE which are
designed in series configuration. Simulation results show that
hybridization of GCC and DEC could provide comfort condition
whereas DEC alone did not. Based on the results the cooling
effectiveness of a hybrid system is more than unity. Thus, this novel
hybrid system could decrease the air temperature below the ambient
wet-bulb temperature. This environmentally clean and energy
efficient system can be considered as an alternative to the mechanical
vapor compression systems.
Abstract: Shape memory alloy (SMA) actuators have found a
wide range of applications due to their unique properties such as high
force, small size, lightweight and silent operation. This paper presents
the development of compact (SMA) actuator and cooling system in
one unit. This actuator is developed for multi-fingered hand. It
consists of nickel-titanium (Nitinol) SMA wires in compact forming.
The new arrangement insulates SMA wires from the human body by
housing it in a heat sink and uses a thermoelectric device for rejecting
heat to improve the actuator performance. The study uses
optimization methods for selecting the SMA wires geometrical
parameters and the material of a heat sink. The experimental work
implements the actuator prototype and measures its response.
Abstract: The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.
Abstract: Growing world population has fundamental impacts
and often catastrophic on natural habitat. The immethodical
consumption of energy, destruction of the forests and extinction of
plant and animal species are the consequence of this experience.
Urban sustainability and sustainable urban development, that is so
spoken these days, should be considered as a strategy, goal and
policy, beyond just considering environmental issues and protection.
The desert-s climate has made a bunch of problems for its residents.
Very hot and dry climate in summers of the Iranian desert areas,
when there was no access to modern energy source and mechanical
cooling systems in the past, made Iranian architects to design a
natural ventilation system in their buildings. The structure, like a
tower going upward the roof, besides its ornamental application and
giving a beautiful view to the building, was used as a spontaneous
ventilation system. In this paper, it has been tried to name the
problems of the area and it-s inconvenience, then some answers has
pointed out in order to solve the problems and as an alternative
solution BADGIR (wind-catcher) has been introduced as a solution
knowing that it has been playing a major role in dealing with the
problems.
Abstract: In a nuclear reactor Loss of Coolant accident (LOCA)
considers wide range of postulated damage or rupture of pipe in the
heat transport piping system. In the case of LOCA with/without
failure of emergency core cooling system in a Pressurised Heavy
water Reactor, the Pressure Tube (PT) temperature could rise
significantly due to fuel heat up and gross mismatch of the heat
generation and heat removal in the affected channel. The extent and
nature of deformation is important from reactor safety point of view.
Experimental set-ups have been designed and fabricated to simulate
ballooning (radial deformation) of PT for 220 MWe IPHWRs.
Experiments have been conducted by covering the CT by ceramic
fibers and then by submerging CT in water of voided PTs. In both
the experiments, it is observed that ballooning initiates at a
temperature around 665´┐¢C and complete contact between PT and
Caldaria Tube (CT) occurs at around 700´┐¢C approximately. The
strain rate is found to be 0.116% per second. The structural integrity
of PT is retained (no breach) for all the experiments. The PT heatup
is found to be arrested after the contact between PT and CT, thus
establishing moderator acting as an efficient heat sink for IPHWRs.
Abstract: This paper presents the development of low cost Nano membrane fabrication system. The system is specially designed for anodic aluminum oxide membrane. This system is capable to perform the processes such as anodization and electro-polishing. The designed machine was successfully tested for 'mild anodization' (MA) for 48 hours and 'hard anodization' (HA) for 3 hours at constant 0oC. The system is digitally controlled and guided for temperature maintenance during anodization and electro-polishing. The total cost of the developed machine is 20 times less than the multi-cooling systems available in the market which are generally used for this purpose.
Abstract: As the data-driven economy is growing faster than
ever and the demand for energy is being spurred, we are facing
unprecedented challenges of improving energy efficiency in data
centers. Effectively maximizing energy efficiency or minimising the
cooling energy demand is becoming pervasive for data centers. This
paper investigates overall energy consumption and the energy
efficiency of cooling system for a data center in Finland as a case
study. The power, cooling and energy consumption characteristics
and operation condition of facilities are examined and analysed.
Potential energy and cooling saving opportunities are identified and
further suggestions for improving the performance of cooling system
are put forward. Results are presented as a comprehensive evaluation
of both the energy performance and good practices of energy
efficient cooling operations for the data center. Utilization of an
energy recovery concept for cooling system is proposed. The
conclusion we can draw is that even though the analysed data center
demonstrated relatively high energy efficiency, based on its power
usage effectiveness value, there is still a significant potential for
energy saving from its cooling systems.
Abstract: Accurate and comprehensive thermodynamic properties of pure and mixture of refrigerants are in demand by both producers and users of these materials. Information about thermodynamic properties is important initially to qualify potential candidates for working fluids in refrigeration machinery. From practical point of view, Refrigerants and refrigerant mixtures are widely used as working fluids in many industrial applications, such as refrigerators, heat pumps, and power plants The present work is devoted to evaluating seven cubic equations of state (EOS) in predicting gas and liquid phase volumetric properties of nine ozone-safe refrigerants both in super and sub-critical regions. The evaluations, in sub-critical region, show that TWU and PR EOS are capable of predicting PVT properties of refrigerants R32 within 2%, R22, R134a, R152a and R143a within 1% and R123, R124, R125, TWU and PR EOS's, from literature data are 0.5% for R22, R32, R152a, R143a, and R125, 1% for R123, R134a, and R141b, and 2% for R124. Moreover, SRK EOS predicts PVT properties of R22, R125, and R123 to within aforementioned errors. The remaining EOS's predicts volumetric properties of this class of fluids with higher errors than those above mentioned which are at most 8%.In general, the results are in favor of the preference of TWU and PR EOS over other remaining EOS's in predicting densities of all mentioned refrigerants in both super and sub critical regions. Typically, this refrigerant is known to offer advantages such as ozone depleting potential equal to zero, Global warming potential equal to 140, and no toxic.
Abstract: The paper discusses a 3D numerical solution of the inverse boundary problem for a continuous casting process of alloy. The main goal of the analysis presented within the paper was to estimate heat fluxes along the external surface of the ingot. The verified information on these fluxes was crucial for a good design of a mould, effective cooling system and generally the whole caster. In the study an enthalpy-porosity technique implemented in Fluent package was used for modeling the solidification process. In this method, the phase change interface was determined on the basis of the liquid fraction approach. In inverse procedure the sensitivity analysis was applied for retrieving boundary conditions. A comparison of the measured and retrieved values showed a high accuracy of the computations. Additionally, the influence of the accuracy of measurements on the estimated heat fluxes was also investigated.