Abstract: A scaffold is necessary for tooth regeneration because of its three-dimensional geometry. For restoration of defect, it is necessary for the scaffold to be prepared in the shape of the defect. Sponges made from polyvinyl alcohol with formalin cross-linking (PVF sponge) have been used for scaffolds for bone formation in vivo. To induce osteogenesis within the sponge, methods of growing rat bone marrow cells (rBMCs) among the fiber structures in the sponge might be considered. Storage of rBMCs among the fibers in the sponge coated with dextran (10 kDa) was tried. After seeding of rBMCs to PVF sponge immersed in dextran solution at 2 g/dl concentration, osteogenesis was recognized in subcutaneously implanted PVF sponge as a scaffold in vivo. The level of osteocalcin was 25.28±5.71 ng/scaffold and that of Ca was 129.20±19.69 µg/scaffold. These values were significantly higher than those in sponges without dextran coating (p
Abstract: METIS is the Multi Element Telescope for Imaging
and Spectroscopy, a Coronagraph aboard the European Space
Agency-s Solar Orbiter Mission aimed at the observation of the solar
corona via both VIS and UV/EUV narrow-band imaging and spectroscopy. METIS, with its multi-wavelength capabilities, will
study in detail the physical processes responsible for the corona heating and the origin and properties of the slow and fast solar wind.
METIS electronics will collect and process scientific data thanks to its detectors proximity electronics, the digital front-end subsystem
electronics and the MPPU, the Main Power and Processing Unit,
hosting a space-qualified processor, memories and some rad-hard
FPGAs acting as digital controllers.This paper reports on the overall
METIS electronics architecture and data processing capabilities
conceived to address all the scientific issues as a trade-off solution between requirements and allocated resources, just before the
Preliminary Design Review as an ESA milestone in April 2012.
Abstract: Recently, several designs of single fed circularly
polarized microstrip antennas have been studied. Relatively, a few
designs for achieving circular polarization using triangular microstrip
antenna are available. Typically existing design of single fed
circularly polarized triangular microstrip antennas include the use of
equilateral triangular patch with a slit or a horizontal slot on the patch
or addition a narrow band stub on the edge or a vertex of triangular
patch.
In other word, with using a narrow band tune stub on middle of an
edge of triangle causes of facility to compensate the possible
fabrication error and substrate materials with easier adjusting the
tuner stub length. Even though disadvantages of this method is very
long of stub (approximate 1/3 length of triangle edge). In this paper,
instead of narrow band stub, a wide band stub has been applied,
therefore the length of stub by this method has been decreased
around 1/10 edge of triangle in addition changing the aperture angle
of stub, provides more facility for designing and producing circular
polarization wave.
Abstract: A biocompatible ferrofluid have been prepared by coprecipitation
of FeCl2.4H2O and FeCl3.6H2O under ultrasonic
irradiation and with NaOH as alkaline agent. Cystein was also used
as capping agent in the solution. Magnetic properties of the produced
ferrofluid were then determined by VSM test and magnetite
nanoparticles were characterized by XRD and TEM techniques. The
effect of surfactant to Fe ion weight ratio was also studied during this
project by using two different amount of Dextran. Results showed the
presence of a biocompatible superparamagnetic ferrofluid including
magnetite nanoparticles with particle size ranging under 20 nm. The
increase in the surfactant content results in the narrowing of the size
distribution and reduction of the particle size and more solution
stability.
Abstract: A design of communication area for infrared
electronic-toll-collection systems to provide an extended
communication interval in the vehicle traveling direction and
regular boundary between contiguous traffic lanes is proposed.
By utilizing two typical low-cost commercial infrared LEDs with
different half-intensity angles Φ1/2 = 22◦ and 10◦, the radiation
pattern of the emitter is designed to properly adjust the spatial
distribution of the signal power. The aforementioned purpose
can be achieved with an LED array in a three-piece structure
with appropriate mounting angles. With this emitter, the influence
of the mounting parameters, including the mounting height and
mounting angles of the on-board unit and road-side unit, on the
system performance in terms of the received signal strength and
communication area are investigated. The results reveal that, for
our emitter proposed in this paper, the ideal ”long-and-narrow”
characteristic of the communication area is very little affected by
these mounting parameters. An optimum mounting configuration is
also suggested.
Abstract: In this paper we present a technique to speed up
ICA based on the idea of reducing the dimensionality of the data
set preserving the quality of the results. In particular we refer to
FastICA algorithm which uses the Kurtosis as statistical property
to be maximized. By performing a particular Johnson-Lindenstrauss
like projection of the data set, we find the minimum dimensionality
reduction rate ¤ü, defined as the ratio between the size k of the reduced
space and the original one d, which guarantees a narrow confidence
interval of such estimator with high confidence level. The derived
dimensionality reduction rate depends on a system control parameter
β easily computed a priori on the basis of the observations only.
Extensive simulations have been done on different sets of real world
signals. They show that actually the dimensionality reduction is very
high, it preserves the quality of the decomposition and impressively
speeds up FastICA. On the other hand, a set of signals, on which the
estimated reduction rate is greater than 1, exhibits bad decomposition
results if reduced, thus validating the reliability of the parameter β.
We are confident that our method will lead to a better approach to
real time applications.
Abstract: A power measurement algorithm of the input mix components of the noise signal and narrowband interference is considered using functional transformations of the input mix in the postdetection processing channel. The algorithm efficiency analysis has been carried out for different interference-to-signal ratio. Algorithm performance features have been explored by numerical experiment results.
Abstract: A lot of recent research have spoken on the relation
between the increase of the homocysteinemia and some kinds of
cancer . For that, our study was based on the research of a possible
relation between the increase of the concentration of this amino-acid
in the plasma and the appearance of the disease of the Acute
Lymphoblastic Leukaemia in a part of Algerian children with Berber
origin in the East of Algeria . The study has done on 47 ill persons
with an average age of (09±06 ) years , with whom the disease has
diagnosed by blood and marrow examination in the hospital of blood
diseases in the CHU of Batna, and on 194 healthy witnesses of the
same age. The two groups were benefited by a dosage of the
concentration of the homocysteine vitamin B9 ,vitamin B12 , and
also of the study of special polymorphisms of indispensable enzymes
in the metabolism of this acid , and that by the use of the method (
Light cycler ) Real time PCR , on the following enzymes : MS (
C2756G ), MSR ( A66G ) ,MTHFR1 ( C677T ) and MTHFR2
(A1298C). The obtained results have revealed that the rate of the
homozygote muted genotype is the less frequent in the two groups ,
and that exist at list one genotype of each enzyme in the ill group and
in which the percentage exceed with remarkable way the same
genotype in the healthy group and we notice specially the muted
genotype GG of -the methionine synthetase-and the form TT of the
enzyme – methyline tetra hydrofolate reductase – We notice the
existence of considerable number of genotypes in the ill group lied
with characteristic increase of this Amino-acid ,and that for the
reduction of the biologic activity of these enzymes which become
inefficient in the transfer of the homocysteine into the methionine
and cause the diminution of the biologic activity of these enzymes
and with consequence the reduction of the percentage of methylic
radicals in the DNA of studied genes and that lead to the increase of
the activity and the capacity of transcription , and it-s so probably
that this last one is one of the factors of this disease especially if we
know that the specific check-up of vitamins is normal and similar in
the two groups , which ovoid the hypothesis of the reduction of
vitamins . We notice also that the heterozygote genotype is the less in
the sick category except the MTHFR2. Wild genotype is more
frequent in the witness group except MSR. Even these results are
partials; they open a new way in the genetic diagnosis of this
malicious disease which allow a precocious diagnosis and the use of
an effective and appropriated treatment in the same time.
Abstract: This study discusses the effect of uncertainty on
production levels of a petrochemical complex. Uncertainly or
variations in some model parameters, such as prices, supply and
demand of materials, can affect the optimality or the efficiency of any
chemical process. For any petrochemical complex with many plants,
there are many sources of uncertainty and frequent variations which
require more attention. Many optimization approaches are proposed
in the literature to incorporate uncertainty within the model in order
to obtain a robust solution. In this work, a stability analysis approach
is applied to a deterministic LP model of a petrochemical complex
consists of ten plants to investigate the effect of such variations on
the obtained optimal production levels. The proposed approach can
determinate the allowable variation ranges of some parameters,
mainly objective or RHS coefficients, before the system lose its
optimality. Parameters with relatively narrow range of variations, i.e.
stability limits, are classified as sensitive parameters or constraints
that need accurate estimate or intensive monitoring. These stability
limits offer easy-to-use information to the decision maker and help in
understanding the interaction between some model parameters and
deciding when the system need to be re-optimize. The study shows
that maximum production of ethylene and the prices of intermediate
products are the most sensitive factors that affect the stability of the
optimum solution
Abstract: This paper presents a low cost automatic system for
sampling the electric field in a limited area. The scanning area is a
flat surface parallel to the ground at a selected height. We discuss
in detail the hardware, software and all the arrangements involved
in the system operation. In order to show the system performance
we include a campaign of narrow band measurements with 6017
sample points in the surroundings of a cellular base station. A
commercial isotropic antenna with three orthogonal axes was used
as sampling device. The results are analyzed in terms of its space
average, standard deviation and statistical distribution.
Abstract: This research investigates the effects of the opening
shape and location on the structural behavior of reinforced concrete
deep beam with openings, while keeping the opening size unchanged.
The software ANSYS 12.1 is used to handle the nonlinear finite
element analysis. The ultimate strength of reinforced concrete deep
beam with opening obtained by ANSYS 12.1 shows fair agreement
with the experimental results, with a difference of no more than 20%. The present work concludes that the opening location has much more effect on the structural strength than the opening shape. It was
concluded that placing the openings near the upper corners of the
deep beam may double the strength, and the use of a rectangular
narrow opening, with the long sides in the horizontal direction, can save up to 40% of structural strength of the deep beam.
Abstract: Deoxygenation of beef fat for the production of hydrogenated biodiesel is investigated in a high pressure continuous flow fixed bed reactor over palladium-supported mesoporous titania catalyst synthesized via a combined single-step sol-gel process with surfactant-assisted templating method (SATM). The catalyst possessed a mesoporous charactheristic with high surface area and narrow pore size distribution. The main products of all Pd/TiO2 catalysts are n-heptadecane (n-C17) and n-pentadecane (n-C15) resulting from decarbonylation reaction. Pd/TiO2 catalyst synthesized via a combined single-step sol-gel process with SATM (SSSG) gave higher activity and selectivity to the desired products when compared to IWI/SG-TiO2 and IWI/P25-TiO2, respectively. SSSG catalyst gave the average conversion up to 80-90 % and 80 % for the selectivity in diesel range hydrocarbons. This result may cause by the higher surface area and the ability in dispersion of palladium ion in mesoporous of TiO2 during sol-gel process.
Abstract: This paper presents the results of a study aimed at
establishing the temperature distribution during the welding of
magnesium alloy sheets by Pulsed Current Gas Tungsten Arc
Welding (PCGTAW) and Constant Current Gas Tungsten Arc
Welding (CCGTAW) processes. Pulsing of the GTAW welding
current influences the dimensions and solidification rate of the fused
zone, it also reduces the weld pool volume hence a narrower bead. In
this investigation, the base material considered was 2mm thin AZ 31
B magnesium alloy, which is finding use in aircraft, automobile and
high-speed train components. A finite element analysis was carried
out using ANSYS, and the results of the FEA were compared with
the experimental results. It is evident from this study that the finite
element analysis using ANSYS can be effectively used to model
PCGTAW process for finding temperature distribution.
Abstract: Information on weed distribution within the field is necessary to implement spatially variable herbicide application. Since hand labor is costly, an automated weed control system could be feasible. This paper deals with the development of an algorithm for real time specific weed recognition system based on Histogram Maxima with threshold of an image that is used for the weed classification. This algorithm is specifically developed to classify images into broad and narrow class for real-time selective herbicide application. The developed system has been tested on weeds in the lab, which have shown that the system to be very effectiveness in weed identification. Further the results show a very reliable performance on images of weeds taken under varying field conditions. The analysis of the results shows over 95 percent classification accuracy over 140 sample images (broad and narrow) with 70 samples from each category of weeds.
Abstract: Intravitreal injection (IVI) is the most common treatment for eye posterior segment diseases such as endopthalmitis, retinitis, age-related macular degeneration, diabetic retinopathy, uveitis, and retinal detachment. Most of the drugs used to treat vitreoretinal diseases, have a narrow concentration range in which they are effective, and may be toxic at higher concentrations. Therefore, it is critical to know the drug distribution within the eye following intravitreal injection. Having knowledge of drug distribution, ophthalmologists can decide on drug injection frequency while minimizing damage to tissues. The goal of this study was to develop a computer model to predict intraocular concentrations and pharmacokinetics of intravitreally injected drugs. A finite volume model was created to predict distribution of two drugs with different physiochemical properties in the rabbit eye. The model parameters were obtained from literature review. To validate this numeric model, the in vivo data of spatial concentration profile from the lens to the retina were compared with the numeric data. The difference was less than 5% between the numerical and experimental data. This validation provides strong support for the numerical methodology and associated assumptions of the current study.
Abstract: Bone remodeling occurs by the balanced action of
bone resorbing osteoclasts (OC) and bone-building osteoblasts.
Increased bone resorption by excessive OC activity contributes
to malignant and non-malignant diseases including osteoporosis.
To study OC differentiation and function, OC formed in
in vitro cultures are currently counted manually, a tedious
procedure which is prone to inter-observer differences. Aiming
for an automated OC-quantification system, classification of
OC and precursor cells was done on fluorescence microscope
images based on the distinct appearance of fluorescent nuclei.
Following ellipse fitting to nuclei, a combination of eight
features enabled clustering of OC and precursor cell nuclei.
After evaluating different machine-learning techniques, LOGREG
achieved 74% correctly classified OC and precursor cell
nuclei, outperforming human experts (best expert: 55%). In
combination with the automated detection of total cell areas,
this system allows to measure various cell parameters and most
importantly to quantify proteins involved in osteoclastogenesis.