Abstract: Brahmaputra River is known according to the Hindu mythology the son of the Lord Brahma. According to this name, the river Brahmaputra creates mass destruction during the monsoon season in Assam, India. It is a state situated in North-East part of India. This is one of the essential states out of the seven countries of eastern India, where almost all entire Brahmaputra flow carried out. The other states carry their tributaries. In the present case study, the spatial analysis performed in this specific case the number of MODIS data are acquired. In the method of detecting the change, the spray content was found during heavy rainfall and in the flooded monsoon season. By this method, particularly the analysis over the Brahmaputra outflow determines the flooded season. The charged particle-associated in aerosol content genuinely verifies the heavy water content below the ground surface, which is validated by trend analysis through rainfall spectrum data. This is confirmed by in-situ sampled view data from a different position of Brahmaputra River. Further, a Hyperion Hyperspectral 30 m resolution data were used to scan the sediment deposits, which is also confirmed by in-situ sampled view data from a different position.
Abstract: Packages designed for transport of radioactive material
must satisfy rigorous safety regulations specified by the International
Atomic Energy Agency (IAEA). Higher Activity Waste (HAW)
transport packages have to maintain containment of their contents
during normal and accident conditions of transport (NCT and ACT).
To ensure containment criteria is satisfied these packages are required
to be leak-tight in all transport conditions to meet allowable activity
release rates. Package design safety reports are the safety cases
that provide the claims, evidence and arguments to demonstrate that
packages meet the regulations and once approved by the competent
authority (in the UK this is the Office for Nuclear Regulation) a
licence to transport radioactive material is issued for the package(s).
The standard approach to demonstrating containment in the RWM
transport safety case is set out in BS EN ISO 12807. In this
document a method for measuring a leak rate from the package
is explained by way of a small interspace test volume situated
between two O-ring seals on the underside of the package lid.
The interspace volume is pressurised and a pressure drop measured.
A small interspace test volume makes the method more sensitive
enabling the measurement of smaller leak rates. By ascertaining the
activity of the contents, identifying a releasable fraction of material
and by treating that fraction of material as a gas, allowable leak
rates for NCT and ACT are calculated. The adherence to basic
safety principles in ISO12807 is very pessimistic and current practice
in the demonstration of transport safety, which is accepted by the
UK regulator. It is UK government policy that management of
HAW will be through geological disposal. It is proposed that the
intermediate level waste be transported to the geological disposal
facility (GDF) in large cuboid packages. This poses a challenge
for containment demonstration because such packages will have
long seals and therefore large interspace test volumes. There is also
uncertainty on the releasable fraction of material within the package
ullage space. This is because the waste may be in many different
forms which makes it difficult to define the fraction of material
released by the waste package. Additionally because of the large
interspace test volume, measuring the calculated leak rates may not
be achievable. For this reason a justification for a lower releasable
fraction of material is sought. This paper considers the use of aerosol
processes to reduce the releasable fraction for both NCT and ACT. It
reviews the basic coagulation and removal processes and applies the
dynamic aerosol balance equation. The proposed solution includes
only the most well understood physical processes namely; Brownian
coagulation and gravitational settling. Other processes have been
eliminated either on the basis that they would serve to reduce the
release to the environment further (pessimistically in keeping with
the essence of nuclear transport safety cases) or that they are not
credible in the conditions of transport considered.
Abstract: Strain sensors based on a change in resistance are
well established for the measurement of forces, stresses, or material
fatigue. Within the scope of this paper, fully additive manufactured
strain sensors were produced using an ink of silver nanoparticles.
Their behavior was evaluated by periodic tensile tests. Printed
strain sensors exhibit two advantages: Their measuring grid is
adaptable to the use case and they do not need a carrier-foil,
as the measuring structure can be printed directly onto a thin
sprayed varnish layer on the aluminum specimen. In order to
compare quality characteristics, the sensors have been manufactured
using two different technologies, namely aerosoljet-printing and
micropipette-dispensing. Both processes produce structures which
exhibit continuous features (in contrast to what can be achieved with
droplets during inkjet printing). Briefly summarized the results show
that aerosoljet-printing is the preferable technology for specimen with
non-planar surfaces whereas both technologies are suitable for flat
specimen.
Abstract: The present investigation was conducted to detect the type and concentrations of bacterial and fungal bioaerosols in one room (bedroom) of each selected residential building located in different regions of Qom during February 2015 (n=9) to July 2016 (n=11). Moreover, we evaluated the efficiency of negative air ions (NAIs) in bioaerosol reduction in indoor air in residential buildings. In the first step, the mean concentrations of bacterial and fungal in nine sampling sites evaluated in winter were 744 and 579 colony forming units (CFU)/m3, while these values were 1628.6 and 231 CFU/m3 in the 11 sampling sites evaluated in summer, respectively. The most predominant genera between bacterial and fungal in all sampling sites were detected as Micrococcus spp. and Staphylococcus spp. and also, Aspergillus spp. and Penicillium spp., respectively. The 95% and 45% of sampling sites have bacterial and fungal concentrations over the recommended levels, respectively. In the removal step, we achieved a reduction with a range of 38% to 93% for bacterial genera and 25% to 100% for fungal genera by using NAIs. The results suggested that NAI is a highly effective, simple and efficient technique in reducing the bacterial and fungal concentration in the indoor air of residential buildings.
Abstract: Atmospheric concentrations of some heavy metal compounds (Pb, Cd, Ni) and the metalloid As were identified and determined in airborne PM2.5 particles in urban sites of Győr, northwest area of Hungary. PM2.5 aerosol samples were collected in two different sampling sites and the trace metal(loid) (Pb, Ni, Cd and As) content were analyzed by atomic absorption spectroscopy. The concentration of PM2.5 fraction was varied between 12.22 and 36.92 μg/m3 at the two sampling sites. The trend of heavy metal mean concentrations regarding the mean value of the two urban sites of Győr was found in decreasing order of Pb > Ni > Cd. The mean values were 7.59 ng/m3 for Pb, 0.34 ng/m3 for Ni and 0.11 ng/m3 for Cd, respectively. The metalloid As could be detected only in 3.57% of the total collected samples. The levels of PM2.5 bounded heavy metals were determined and compared with other cities located in Hungary.
Abstract: An assessment of the air quality of Győr (Hungary) was performed by determining the ambient concentrations of PM10-bound carcinogenic polycyclic aromatic hydrocarbons (cPAHs) in different seasons. A high volume sampler was used for the collection of ambient aerosol particles, and the associated cPAH compounds (benzo[a]pyrene (BaP), benzo[a]anthracene, benzofluoranthene isomers, indeno[123-cd]pyrene and dibenzo[ah]anthracene) were analyzed by a gas chromatographic method. Higher mean concentrations of total cPAHs were detected in samples collected in winter (9.62 ng/m3) and autumn (2.69 ng/m3) compared to spring (1.05 ng/m3) and summer (0.21 ng/m3). The calculated BaP toxic equivalent concentrations have also reflected that the local population appears to be exposed to significantly higher cancer risk in the heating seasons. Moreover, the concentration levels of cPAHs determined in this study were compared to other Hungarian urban sites.
Abstract: Periodic DFT calculations were performed to study the chemistry of CsI particles and the possible release of volatile iodine from CsI surfaces for nuclear safety interest. The results show that water adsorbs at low temperature associatively on the (011) surface of CsI, while water desorbs at higher temperatures. On the other hand, removing iodine species from the surface requires oxidizing the surface one time for each removed iodide atom. The activation energy of removing I2 from the surface in the presence of two OH is 1,2 eV.
Abstract: A wide range of health effects among occupants are associated with the exposure to bioaerosols from fungal sources. Although the accurate role of these aerosols in causing the symptoms and diseases is poorly understood, the important effect of bioaerosol exposure on human health is well recognized. Thus, there is a need to determine all of the contributing factors related to the concentration of fungi in indoor air. In this study, we reviewed and summarized the different factors affecting the concentrations of viable fungi in school buildings. The literature research was conducted using Pubmed and Google Scholar. In addition, we searched the lists of references of selected articles. According to the literature, the main factors influencing the concentration of viable fungi in the school buildings are moisture damage in building structures, the season (temperature and humidity conditions), the type and rate of ventilation, the number and activities of occupants and diurnal variations. This study offers valuable information that can be used in the interpretation of the fungal analysis and to decrease microbial exposure by reducing known sources and/or contributing factors. However, more studies of different local factors contributing to the human microbial exposure in school buildings—as well as other type of buildings and different indoor environments—are needed.
Abstract: Investigation of the discharges from the artificial charged water aerosol clouds in presence of the arrays of the model hydrometeors could help to receive the new data about the peculiarities of the return stroke formation between the thundercloud and the ground when the large volumes of the hail particles participate in the lightning discharge initiation and propagation stimulation. Artificial charged water aerosol clouds of the negative or positive polarity with the potential up to one million volts have been used. Hail has been simulated by the group of the conductive model hydrometeors of the different form. Parameters of the impulse current of the main stage of the discharge between the artificial positively and negatively charged water aerosol clouds and the ground in presence of the model hydrometeors array and of its corresponding electromagnetic radiation have been determined. It was established that the parameters of the array of the model hydrometeors influence on the parameters of the main stage of the discharge between the artificial thundercloud cell and the ground. The maximal values of the main stage current impulse parameters and the electromagnetic radiation registered by the plate antennas have been found for the array of the model hydrometeors of the cylinder revolution form for the negatively charged aerosol cloud and for the array of the hydrometeors of the plate rhombus form for the positively charged aerosol cloud, correspondingly. It was found that parameters of the main stage of the discharge between the artificial charged water aerosol cloud and the ground in presence of the model hydrometeor array of the different considered forms depend on the polarity of the artificial charged aerosol cloud. In average, for all forms of the investigated model hydrometeors arrays, the values of the amplitude and the current rise of the main stage impulse current and the amplitude of the corresponding electromagnetic radiation for the artificial charged aerosol cloud of the positive polarity were in 1.1-1.9 times higher than for the charged aerosol cloud of the negative polarity. Thus, the received results could indicate to the possible more important role of the big volumes of the large hail arrays in the thundercloud on the parameters of the return stroke for the positive lightning.
Abstract: Hypothesis of the lightning initiation on the arrays of large hydrometeors are in the consideration. There is no agreement about the form the hydrometeors that could be the best for the lightning initiation from the thundercloud. Artificial charged water aerosol clouds of the positive or negative polarity could help investigate the possible influence of the hydrometeor form on the peculiarities and the probability of the lightning discharge initiation between the thundercloud and the ground. Artificial charged aerosol clouds that could create the electric field strength in the range of 5-6 kV/cm to 16-18 kV/cm have been used in experiments. The array of the model hydrometeors of the volume and plate form has been disposed near the bottom cloud boundary. It was established that the different kinds of the discharge could be initiated in the presence of the model hydrometeors array – from the cloud discharges up to the diffuse and channel discharges between the charged cloud and the ground. It was found that the form of the model hydrometeors could significantly influence the channel discharge initiation from the artificial charged aerosol cloud of the negative or positive polarity correspondingly. Analysis and generalization of the experimental results have shown that the maximal probability of the channel discharge initiation and propagation stimulation has been observed for the artificial charged cloud of the positive polarity when the arrays of the model hydrometeors of the cylinder revolution form have been used. At the same time, for the artificial charged clouds of the negative polarity, application of the model hydrometeor array of the plate rhombus form has provided the maximal probability of the channel discharge formation between the charged cloud and the ground. The established influence of the form of the model hydrometeors on the channel discharge initiation and from the artificial charged water aerosol cloud and its following successful propagation has been related with the different character of the positive and negative streamer and volume leader development on the model hydrometeors array being near the bottom boundary of the charged cloud. The received experimental results have shown the possibly important role of the form of the large hail particles precipitated in thundercloud on the discharge initiation.
Abstract: With the rapid development of national modern industry, people begin to pay attention to environmental pollution and harm caused by industrial dust. Based on above, a numerical study on the dedusting technology of industrial environment was conducted. The dynamic models of multicomponent particles collision and coagulation, breakage and deposition are developed, and the interaction of water droplet and aerosol particle in 2-Dimension flow field was researched by Eulerian-Lagrangian method and Multi-Monte Carlo method. The effects of the droplet scale, movement speed of droplet and the flow field structure on scavenging efficiency were analyzed. The results show that under the certain condition, 30μm of droplet has the best scavenging efficiency. At the initial speed 1m/s of droplets, droplets and aerosol particles have more time to interact, so it has a better scavenging efficiency for the particle.
Abstract: Atmospheric aerosols have several important environmental impacts and health effects in point of air quality. Monitoring the PM10-bound polycyclic aromatic hydrocarbons (PAHs) could have important environmental significance and health protection aspects. Benzo(a)pyrene (BaP) is the most relevant indicator of these PAH compounds. In Hungary, the Hungarian Air Quality Network provides air quality monitoring data for several air pollutants including BaP, but these data show only the annual mean concentrations and maximum values. Seasonal variation of BaP concentrations comparing the heating and non-heating periods could have important role and difference as well. For this reason, the main objective of this study was to assess the annual concentration and seasonal variation of BaP associated with PM10 in the ambient air of Northwestern Hungary seven different sampling sites (six urban and one rural) in the sampling period of 2008–2013. A total of 1475 PM10 aerosol samples were collected in the different sampling sites and analyzed for BaP by gas chromatography method. The BaP concentrations ranged from undetected to 8 ng/m3 with the mean value range of 0.50-0.96 ng/m3 referring to all sampling sites. Relatively higher concentrations of BaP were detected in samples collected in each sampling site in the heating seasons compared with non-heating periods. The annual mean BaP concentrations were comparable with the published data of the other Hungarian sites.
Abstract: In Hungary, the measurement of ambient PM10-bound polycyclic aromatic hydrocarbon (PAH) concentrations is great importance for a number of reasons related to human health, the environment and compliance with European Union legislation. However, the monitoring of PAHs associated with PM2.5 aerosol fraction is still incomplete. Therefore, the main aim of this study was to investigate the concentration levels of PAHs in PM2.5 urban aerosol fraction. PM2.5 and associated PAHs were monitored in November 2014 in an urban site of Győr (Northwest Hungary). The aerosol samples were collected every day for 24-hours over two weeks with a high volume air sampler provided with a PM2.5 cut-off inlet. The levels of 19 PAH compounds associated with PM2.5 aerosol fraction were quantified by a gas chromatographic method. Polluted air quality for PM2.5 (>25 g/m3) was indicated in 50% of the collected samples. The total PAHs concentrations ranged from 2.1 to 37.3 ng/m3 with the mean value of 12.4 ng/m3. Indeno(123-cd)pyrene (IND) and sum of three benzofluoranthene isomers were the most dominant PAH species followed by benzo(ghi)perylene and benzo(a)pyrene (BaP). Using BaP-equivalent approach on the concentration data of carcinogenic PAH species, BaP, and IND contributed the highest carcinogenic exposure equivalent (1.50 and 0.24 ng/m3 on average). A selected number of concentration ratios of specific PAH compounds were calculated to evaluate the possible sources of PAH contamination. The ratios reflected that the major source of PAH compounds in the PM2.5 aerosol fraction of Győr during the study period was fossil fuel combustion from automobiles.
Abstract: This paper will explore formation of HCl aerosol at atmospheric boundary layers and encourages the uptake of environmental modeling systems (EMSs) as a practice evaluation of gaseous emissions (“framework measures”) from small and medium-sized enterprises (SMEs). The conceptual model predicts greenhouse gas emissions to ecological points beyond landfill site operations. It focuses on incorporation traditional knowledge into baseline information for both measurement data and the mathematical results, regarding parameters influence model variable inputs. The paper has simplified parameters of aerosol processes based on the more complex aerosol process computations. The simple model can be implemented to both Gaussian and Eulerian rural dispersion models. Aerosol processes considered in this study were (i) the coagulation of particles, (ii) the condensation and evaporation of organic vapors, and (iii) dry deposition. The chemical transformation of gas-phase compounds is taken into account photochemical formulation with exposure effects according to HCl concentrations as starting point of risk assessment. The discussion set out distinctly aspect of sustainability in reflection inputs, outputs, and modes of impact on the environment. Thereby, models incorporate abiotic and biotic species to broaden the scope of integration for both quantification impact and assessment risks. The later environmental obligations suggest either a recommendation or a decision of what is a legislative should be achieved for mitigation measures of landfill gas (LFG) ultimately.
Abstract: The paper presents the results of DIAL measurements of the vertical ozone distribution. The ozone lidar operate as part of the measurement complex at Siberian Lidar Station (SLS) of V.E. Zuev Institute of Atmospheric Optics SB RAS, Tomsk (56.5ºN; 85.0ºE) and designed for study of the vertical ozone distribution in the upper troposphere–lower stratosphere. Most suitable wavelengths for measurements of ozone profiles are selected. We present an algorithm for retrieval of vertical distribution of ozone with temperature and aerosol correction during DIAL lidar sounding of the atmosphere. The temperature correction of ozone absorption coefficients is introduced in the software to reduce the retrieval errors. Results of lidar measurement at wavelengths of 299 and 341 nm agree with model estimates, which point to acceptable accuracy of ozone sounding in the 6–18 km altitude range.
Abstract: Philip Morris International (PMI) is developing a range
of novel tobacco products with the potential to reduce individual
risk and population harm in comparison to smoking cigarettes.
One of these products is the Tobacco Heating System 2.2 (THS
2.2), (named as the Electrically Heated Tobacco System (EHTS) in
this paper), already commercialized in a number of countries (e.g.,
Japan, Italy, Switzerland, Russia, Portugal and Romania). During use,
the patented EHTS heats a specifically designed tobacco product
(Electrically Heated Tobacco Product (EHTP)) when inserted into
a Holder (heating device). The EHTP contains tobacco material in
the form of a porous plug that undergoes a controlled heating process
to release chemical compounds into vapors, from which an aerosol
is formed during cooling. The aim of this work was to investigate
the aerosol formation characteristics for realistic operating conditions
of the EHTS as well as for relevant gas mixture compositions
measured in the EHTP aerosol consisting mostly of water, glycerol
and nicotine, but also other compounds at much lower concentrations.
The nucleation process taking place in the EHTP during use when
operated in the Holder has therefore been modeled numerically using
an extended Classical Nucleation Theory (CNT) for multicomponent
gas mixtures. Results from the performed simulations demonstrate
that aerosol droplets are formed only in the presence of an aerosol
former being mainly glycerol. Minor compounds in the gas mixture
were not able to reach a supersaturated state alone and therefore
could not generate aerosol droplets from the multicomponent gas
mixture at the operating conditions simulated. For the analytically
characterized aerosol composition and estimated operating conditions
of the EHTS and EHTP, glycerol was shown to be the main aerosol
former triggering the nucleation process in the EHTP. This implies
that according to the CNT, an aerosol former, such as glycerol
needs to be present in the gas mixture for an aerosol to form
under the tested operating conditions. To assess if these conclusions
are sensitive to the initial amount of the minor compounds and to
include and represent the total mass of the aerosol collected during
the analytical aerosol characterization, simulations were carried out
with initial masses of the minor compounds increased by as much
as a factor of 500. Despite this extreme condition, no aerosol
droplets were generated when glycerol, nicotine and water were
treated as inert species and therefore not actively contributing to the
nucleation process. This implies that according to the CNT, an aerosol
cannot be generated without the help of an aerosol former, from
the multicomponent gas mixtures at the compositions and operating
conditions estimated for the EHTP, even if all minor compounds are
released or generated in a single puff.
Abstract: Introduction: This work is aimed to represent the use of the OPTI-JET CS MD1 MR prototype for application of neutral electrolyzed oxidizing water (NEOW) in magnetic resonance rooms. Material and Methods: We produced and used OPTI-JET CS MD1 MR aerosolisator whereby was performed aerosolization. The presence of microorganisms before and after the aerosolisation was recorded with the help of cyclone air sampling. Colony formed units (CFU) was counted. Results: The number of microorganisms in magnetic resonance 3T room was low as expected. Nevertheless, a possible CFU reduction of 87% was recorded. Conclusions: The research has shown that the use of EOW for the air and hard surface disinfection can considerably reduce the presence of microorganisms and consequently the possibility of hospital infections. It has also demonstrated that the use of OPTI-JET CS MD1 MR is very good. With this research, we started new guidelines for aerosolization in magnetic resonance rooms. Future work: We predict that presented technique works very good but we must focus also on time capacity sensors, and new appropriate toxicological studies.
Abstract: Within this paper, latest results on processing of energetic nanomaterials by means of the Spray Flash Evaporation technique are presented. This technology constitutes a highly effective and continuous way to prepare fascinating materials on the nano- and micro-scale. Within the process, a solution is set under high pressure and sprayed into an evacuated atomization chamber. Subsequent ultrafast evaporation of the solvent leads to an aerosol stream, which is separated by cyclones or filters. No drying gas is required, so the present technique should not be confused with spray dying. Resulting nanothermites, insensitive explosives or propellants and compositions are foreseen to replace toxic (according to REACH) and very sensitive matter in military and civil applications. Diverse examples are given in detail: nano-RDX (n-Cyclotrimethylentrinitramin) and nano-aluminum based systems, mixtures (n-RDX/n-TNT - trinitrotoluene) or even cocrystalline matter like n-CL-20/HMX (Hexanitrohexaazaisowurtzitane/ Cyclotetra-methylentetranitramin). These nanomaterials show reduced sensitivity by trend without losing effectiveness and performance. An analytical study for material characterization was performed by using Atomic Force Microscopy, X-Ray Diffraction, and combined techniques as well as spectroscopic methods. As a matter of course, sensitivity tests regarding electrostatic discharge, impact, and friction are provided.
Abstract: Particle size distribution, the most important
characteristics of aerosols, is obtained through electrical
characterization techniques. The dynamics of charged nanoparticles
under the influence of electric field in Electrical Mobility
Spectrometer (EMS) reveals the size distribution of these particles.
The accuracy of this measurement is influenced by flow conditions,
geometry, electric field and particle charging process, therefore by
the transfer function (transfer matrix) of the instrument. In this work,
a wire-cylinder corona charger was designed and the combined fielddiffusion
charging process of injected poly-disperse aerosol particles
was numerically simulated as a prerequisite for the study of a
multichannel EMS. The result, a cloud of particles with no uniform
charge distribution, was introduced to the EMS. The flow pattern and
electric field in the EMS were simulated using Computational Fluid
Dynamics (CFD) to obtain particle trajectories in the device and
therefore to calculate the reported signal by each electrometer.
According to the output signals (resulted from bombardment of
particles and transferring their charges as currents), we proposed a
modification to the size of detecting rings (which are connected to
electrometers) in order to evaluate particle size distributions more
accurately. Based on the capability of the system to transfer
information contents about size distribution of the injected particles,
we proposed a benchmark for the assessment of optimality of the
design. This method applies the concept of Von Neumann entropy
and borrows the definition of entropy from information theory
(Shannon entropy) to measure optimality. Entropy, according to the
Shannon entropy, is the ''average amount of information contained in
an event, sample or character extracted from a data stream''.
Evaluating the responses (signals) which were obtained via various
configurations of detecting rings, the best configuration which gave
the best predictions about the size distributions of injected particles,
was the modified configuration. It was also the one that had the
maximum amount of entropy. A reasonable consistency was also
observed between the accuracy of the predictions and the entropy
content of each configuration. In this method, entropy is extracted
from the transfer matrix of the instrument for each configuration.
Ultimately, various clouds of particles were introduced to the
simulations and predicted size distributions were compared to the
exact size distributions.
Abstract: The main objective of this study was to assess the
seasonal variation of atmospheric polycyclic aromatic hydrocarbon
(PAH) concentrations associated with PM10 in an urban site of Győr,
Hungary. A total of 112 PM10 aerosol samples were collected in the
years of 2012 and 2013 and analyzed for PAHs by gas
chromatography method. The total PAH concentrations (sum of the
concentrations of 19 individual PAH compounds) ranged from 0.19
to 70.16 ng/m3 with the mean value of 12.29 ng/m3. Higher
concentrations of both total PAHs and benzo[a]pyrene (BaP) were
detected in samples collected in the heating seasons. Using BaPequivalent
potency index on the carcinogenic PAH concentration
data, the local population appears to be exposed to significantly
higher cancer risk in the heating seasons. However, the comparison
of the BaP and total PAH concentrations observed for Győr with
other cities it was found that the PAH levels in Győr generally
corresponded to the EU average.