Abstract: Protective relays are components of a protection system
in a power system domain that provides decision making element for
correct protection and fault clearing operations. Failure of the
protection devices may reduce the integrity and reliability of the power
system protection that will impact the overall performance of the
power system. Hence it is imperative for power utilities to assess the
reliability of protective relays to assure it will perform its intended
function without failure. This paper will discuss the application of
reliability analysis using statistical method called Life Data Analysis
in Tenaga Nasional Berhad (TNB), a government linked power utility
company in Malaysia, namely Transmission Division, to assess and
evaluate the reliability of numerical overcurrent protective relays from
two different manufacturers.
Abstract: This paper presents an evaluation of the wind potential in the area of the Lagoon of Venice (Italy). A full anemometric campaign of 2 year measurements, performed by the "Osservatorio Bioclimatologico dell'Ospedale al Mare di Venezia" has been analyzed to obtain the Weibull wind speed distribution and the main wind directions. The annual energy outputs of two candidate horizontal-axis wind turbines (“Aventa AV-7 LoWind" and “Gaia Wind 133-11kW") have been estimated on the basis of the computed Weibull wind distribution, registering a better performance of the former turbine, due to a higher ratio between rotor swept area and rated power of the electric generator, determining a lower cut-in wind speed.