Abstract: High-voltage power transmission lines are the back
bone of electrical power utilities. The stability and continuous
monitoring of this critical infrastructure is pivotal. Nine-Sigma
representing Eskom Holding SOC limited, South Africa has a major
problem on proactive detection of fallen power lines and real time
sagging measurement together with slipping of such conductors. The
main objective of this research is to innovate RFID technology to
solve this challenge. Various options and technologies such as GPS,
PLC, image processing, MR sensors and etc., have been reviewed
and draw backs were made. The potential of RFID to give precision
measurement will be observed and presented. The future research
will look at magnetic and electrical interference as well as corona
effect on the technology.
Abstract: This paper analyses the torsional efforts in gas turbine-generator shafts caused by high speed automatic reclosing of transmission lines. This issue is especially important for cases of three phase short circuit and unsuccessful reclosure of lines in the vicinity of the thermal plant. The analysis was carried out for the thermal plant TERMOPERNAMBUCO located on Northeast region of Brazil. It is shown that stress level caused by lines unsuccessful reclosing can be several times higher than terminal three-phase short circuit. Simulations were carried out with detailed shaft torsional model provided by machine manufacturer and with the “Alternative Transient Program – ATP" program [1]. Unsuccessful three phase reclosing for selected lines in the area closed to the plant indicated most critical cases. Also, reclosing first the terminal next to the gas turbine gererator will lead also to the most critical condition. Considering that the values of transient torques are very sensible to the instant of reclosing, simulation of unsuccessful reclosing with statistics ATP switch were carried out for determination of most critical transient torques for each section of the generator turbine shaft.
Abstract: A power cable is widely used for power supply in
power distributing networks and power transmission lines. Due to
limitations in the production, delivery and setting up power cables,
they are produced and delivered in several separate lengths. Cable
itself, consists of two cable terminations and arbitrary number of
cable joints, depending on the cable route length. Electrical stress
control is needed to prevent a dielectric breakdown at the end of the
insulation shield in both the air and cable insulation. Reliability of
cable joint depends on its materials, design, installation and operating
environment. The paper describes design and performance results for
new modeled cable joints. Design concepts, based on numerical
calculations, must be correct. An Equivalent Electrodes
Method/Boundary Elements Method-hybrid approach that allows
electromagnetic field calculations in multilayer dielectric media,
including inhomogeneous regions, is presented.
Abstract: An on-line condition monitoring method for transmission line is proposed using electrical circuit theory and IT technology in this paper. It is reasonable that the circuit parameters such as resistance (R), inductance (L), conductance (g) and capacitance (C) of a transmission line expose the electrical conditions and physical state of the line. Those parameters can be calculated from the linear equation composed of voltages and currents measured by synchro-phasor measurement technique at both end of the line. A set of linear voltage drop equations containing four terminal constants (A, B ,C ,D ) are mathematical models of the transmission line circuits. At least two sets of those linear equations are established from different operation condition of the line, they may mathematically yield those circuit parameters of the line. The conditions of line connectivity including state of connecting parts or contacting parts of the switching device may be monitored by resistance variations during operation. The insulation conditions of the line can be monitored by conductance (g) and capacitance(C) measurements. Together with other condition monitoring devices such as partial discharge, sensors and visual sensing device etc.,they may give useful information to monitor out any incipient symptoms of faults. The prototype of hardware system has been developed and tested through laboratory level simulated transmission lines. The test has shown enough evident to put the proposed method to practical uses.
Abstract: Transmission network expansion planning (TNEP) is a basic part of power system planning that determines where, when and how many new transmission lines should be added to the network. Up till now, various methods have been presented to solve the static transmission network expansion planning (STNEP) problem. But in all of these methods, lines adequacy rate has not been considered at the end of planning horizon, i.e., expanded network misses adequacy after some times and needs to be expanded again. In this paper, expansion planning has been implemented by merging lines loading parameter in the STNEP and inserting investment cost into the fitness function constraints using genetic algorithm. Expanded network will possess a maximum adequacy to provide load demand and also the transmission lines overloaded later. Finally, adequacy index could be defined and used to compare some designs that have different investment costs and adequacy rates. In this paper, the proposed idea has been tested on the Garvers network. The results show that the network will possess maximum efficiency economically.
Abstract: This paper presents the impact study of apparent
reactance injected by series Flexible AC Transmission System
(FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the
measured impedance of a 400 kV single electrical transmission line
in the presence of phase to earth fault with fault resistance. The study
deals with an electrical transmission line of Eastern Algerian
transmission networks at Group Sonelgaz (Algerian Company of
Electrical and Gas) compensated by TCSR connected at midpoint of
the line. This compensator used to inject active and reactive powers
is controlled by three TCSR-s. The simulations results investigate the
impacts of the TCSR on the parameters of short circuit calculation
and parameters of measured impedance by distance relay in the
presence of earth fault for three cases study.
Abstract: Transmission network expansion planning (TNEP) is an important component of power system planning that its task is to minimize the network construction and operational cost while satisfying the demand increasing, imposed technical and economic conditions. Up till now, various methods have been presented to solve the static transmission network expansion planning (STNEP) problem. But in all of these methods, the lines adequacy rate has not been studied after the planning horizon, i.e. when the expanded network misses its adequacy and needs to be expanded again. In this paper, in order to take transmission lines condition after expansion in to account from the line loading view point, the adequacy of transmission network is considered for solution of STNEP problem. To obtain optimal network arrangement, a decimal codification genetic algorithm (DCGA) is being used for minimizing the network construction and operational cost. The effectiveness of the proposed idea is tested on the Garver's six-bus network. The results evaluation reveals that the annual worth of network adequacy has a considerable effect on the network arrangement. In addition, the obtained network, based on the DCGA, has lower investment cost and higher adequacy rate. Thus, the network satisfies the requirements of delivering electric power more safely and reliably to load centers.
Abstract: An appropriate method for fault identification and classification on extra high voltage transmission line using discrete wavelet transform is proposed in this paper. The sharp variations of the generated short circuit transient signals which are recorded at the sending end of the transmission line are adopted to identify the fault. The threshold values involve fault classification and these are done on the basis of the multiresolution analysis. A comparative study of the performance is also presented for Discrete Fourier Transform (DFT) based Artificial Neural Network (ANN) and Discrete Wavelet Transform (DWT). The results prove that the proposed method is an effective and efficient one in obtaining the accurate result within short duration of time by using Daubechies 4 and 9. Simulation of the power system is done using MATLAB.
Abstract: Bangladesh is a developing country with large
population. Demand of electrical energy is increasing day by day
because of increasing population and industrialization. But due to
limited resources, people here are suffering from power crisis
problem which is considered as a major obstacle to the economic
development. In most of the cases, it is extremely difficult to extend
high tension transmission lines to some of the places that are
separated from the mainland. Renewable energy is considered to be
the right choice for providing clean energy to these remote
settlements. This paper proposes a cost effective design of off-grid
wind-diesel hybrid power system using combined heat and power
(CHP) technology in a grid isolated island, Sandwip, Bangladesh.
Design and simulation of the wind-diesel hybrid power system is
performed considering different factors for the island Sandwip.
Detailed economic analysis and comparison with solar PV system
clearly reveals that wind-diesel hybrid power system can be a cost
effective solution for the isolated island like Sandwip.