Abstract: High temperature deformation behavior of cast 310S stainless steel has been investigated in this study by performing tensile and compression tests at temperatures from 900 to 1200oC. Rectangular ingots of which the dimensions were 350×350×100 in millimeter were cast using vacuum induction melting. Phase equilibrium was calculated using the FactSage®, thermodynamic software and database. Thermal expansion coefficient was also measured on the ingot in the temperature range from room temperature to 1200oC. Tensile strength of cast 310S stainless steel was 9 MPa at 1200oC, which is a little higher than that of a wrought 310S. With temperature decreased, tensile strength increased rapidly and reached up to 72 MPa at 900oC. Elongation also increased with temperature decreased. Microstructure observation revealed that s phase was precipitated along the grain boundary and within the matrix over 1200oC, which is detrimental to high temperature elongation.
Abstract: In this paper, the behavior of different types of DST columns has been studied under bending load. Briefly, composite columns consist of an internal carbon steel tube and an external stainless steel wall that the between the walls are filled with concrete. Composite columns are expected to combine the advantages of all three materials and have the advantage of high flexural stiffness of CFDST columns. In this research, ABAQUS software is used for finite element analysis then the results of ultimate strength of the composite sections are illustrated.
Abstract: The study comprises evaluation of suitability of passive layer created on the surface of AISI 316L stainless steel for products that are intended to have contact with blood. For that purpose, prior to and after chemical passivation, samples were subject to 7 day exposure in artificial plasma at the temperature of T=37°C. Next, tests of metallic ions infiltration from the surface to the solution were performed. The tests were performed with application of spectrometer JY 2000, by Yobin – Yvon, employing Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). In order to characterize physical and chemical features of electrochemical processes taking place during exposure of samples to artificial plasma, tests with application of electrochemical impedance spectroscopy were suggested. The tests were performed with application of measuring unit equipped with potentiostat PGSTAT 302n with an attachment for impedance tests FRA2. Measurements were made in the environment simulating human blood at the temperature of T=37°C. Performed tests proved that application of chemical passivation process for AISI 316L stainless steel used for production of goods intended to have contact with blood is well-grounded and useful in order to improve safety of their usage.
Abstract: Continually increasing working temperature and growing need for greater efficiency and reliability of automotive exhaust require systematic investigation into the thermal fatigue properties especially of high temperature stainless steels. In this study, thermal fatigue properties of 300 series austenitic stainless steels have been evaluated in the temperature ranges of 200-800oC and 200-900oC. Systematic methods for control of temperatures within the predetermined range and measurement of load applied to specimens as a function of temperature during thermal cycles have been established. Thermal fatigue tests were conducted under fully constrained condition, where both ends of specimens were completely fixed. Load relaxation behavior at the temperatures of thermal cycle was closely related with the thermal fatigue property.
Abstract: This study examined the effect of porous dielectric silica gel the discharge ignition voltage and input power in a plasma reactor. For the experiment was used a plasma reactor with two mesh electrodes made of stainless steel with a mesh size of 0.1x0.1mm. The study analyzed and compared with parameters such as power, ignition and operation voltage of the reactor for two dielectrics a porous and glass. During experiment were observed several new phenomena conducted for porous dielectric. The first phenomenon was the reduction the ignition voltage discharge to volume around few hundred volts. Second it was increase input power six times more compared with power those obtained for the glass dielectric. Thirdly difference it is ΔV between ignition voltage Vi and operating voltage reactor Vm for porous dielectric it was 11%, while ΔV for the glass dielectric it was 60%. Also change the discharge characteristics from DBD for glass dielectric to the streamer resistance discharge for the porous dielectric.
Abstract: This paper reports on the effects of heat treatment on 3CR12 and AISI 316 stainless steel grades. Heat treatment was conducted on the steel grades and cooled using two different media; air and water in order to study the effect of each medium on the evolving properties of the samples. The heat treated samples were characterized through the evolving microstructure and hardness. It was found that there was a significant grain size reduction in both the heat treated stainless steel specimens compared to the parent materials. The finer grain sizes were achieved as a result of impediment to growth of one phase by the other. The Vickers microhardness values of the heat treated samples were higher compared to the parent materials due to the fact that each of the steel grades had a proportion of martensitic structures in their microstructures thereby improving the integrity of the material.
Abstract: An experimental investigation has been carried out to study the cooling of a hot horizontal Stainless Steel surface of 3 mm thickness, which has 800±10 C initial temperature. A round water jet of 22 ± 1 oC temperature was injected over the hot surface through straight tube type nozzles of 2.5- 4.8 mm diameter and 250 mm length. The experiments were performed for the jet exit to target surface spacing of 4 times of jet diameter and jet Reynolds number of 5000 -24000. The effect of change in jet Reynolds number on the surface quenching has been investigated form the stagnation point to 16 mm spatial location.
Abstract: In Pharmaceutical industries, it is very important to remove drug residues from the equipment and areas used. The cleaning procedure must be validated, so special attention must be devoted to the methods used for analysis of trace amounts of drugs. A rapid, sensitive and specific reverse phase ultra performance liquid chromatographic (UPLC) method was developed for the quantitative determination of Albendazole in cleaning validation swab samples. The method was validated using an ACQUITY HSS C18, 50 x 2.1mm, 1.8μ column with a isocratic mobile phase containing a mixture of 1.36g of Potassium dihydrogenphosphate in 1000mL MilliQ water, 2mL of triethylamine and pH adjusted to 2.3 ± 0.05 with ortho-phosphoric acid, Acetonitrile and Methanol (50:40:10 v/v). The flow rate of the mobile phase was 0.5 mL min-1 with a column temperature of 350C and detection wavelength at 254nm using PDA detector. The injection volume was 2µl. Cotton swabs, moisten with acetonitrile were used to remove any residue of drug from stainless steel, teflon, rubber and silicon plates which mimic the production equipment surface and the mean extraction-recovery was found to be 91.8. The selected chromatographic condition was found to effectively elute Albendazole with retention time of 0.67min. The proposed method was found to be linear over the range of 0.2 to 150µg/mL and correlation coefficient obtained is 0.9992. The proposed method was found to be accurate, precise, reproducible and specific and it can also be used for routine quality control analysis of these drugs in biological samples either alone or in combined pharmaceutical dosage forms.
Abstract: This study is about the orbital TIG welding robot system which travels on the guide rail installed on the pipe, and welds and tracks the pipe seam using the LVS (Laser Vision Sensor) joint profile data. The orbital welding robot system consists of the robot, welder, controller, and LVS. Moreover we can define the relationship between welding travel speed and wire feed speed, and we can make the linear equation using the maximum and minimum amount of weld metal. Using the linear equation we can determine the welding travel speed and the wire feed speed accurately corresponding to the area of weld captured by LVS. We applied this orbital TIG welding robot system to the stainless steel or duplex pipe on DSME (Daewoo Shipbuilding and Marine Engineering Co. Ltd.,) shipyard and the result of radiographic test is almost perfect. (Defect rate: 0.033%).
Abstract: Synthetic oily wastewaters were prepared from metal working fluids (MWF). Electrocoagulation experiments were performed under constant voltage application. The current, conductivity, pH, dissolved oxygen concentration and temperature were recorded on line at every 5 seconds during the experiments. Effects of applied voltage differences, electrode materials and distance between electrodes on removal efficiency have been investigated. According to the experimental results, the treatment of MWF wastewaters by iron electrodes rather than aluminum and stainless steel was much quicker; and the distance between electrodes should be less than 1cm. The electrocoagulation process was modeled by using block oriented approach and found out that it can be modeled as a single input and multiple output system. Modeling studies indicates that the electrocoagulation process has a nonlinear model structure.
Abstract: Simultaneous measurements of the curves for wear versus distance, wear rate versus distance, and coefficient of friction versus distance were performed in situ to distinguish the transition from severe running-in wear to mild wear. The effects of the initial surface roughness on the severe running-in wear volume were investigated. Disk-on-plate friction and wear tests were carried out with SUS304 austenitic stainless steel in contact with itself under repeated dry sliding conditions at room temperature. The wear volume was dependent on the initial surface roughness. The wear volume when the initial surfaces on the plate and disk had dissimilar roughness was lower than that when these surfaces had similar roughness. For the dissimilar roughness, the wear volume decreased with decreasing initial surface roughness and reached a minimum; it stayed nearly constant as the roughness was less than the mean size of the oxide particles.
Abstract: An experimental investigation was conducted to study the effect of surface roughness on friction factor and heat transfer characteristics in single-phase fluid flow in a stainless steel micro-tube having diameter of 0.85 mm and average internal surface roughness of 1.7 μm with relative surface roughness of 0.002. Distilled water and R134a liquids were used as the working fluids and testing was conducted with Reynolds numbers ranging from 100 to 10,000 covering laminar, transition and turbulent flow conditions. The experiments were conducted with the micro-tube oriented horizontally with uniform heat fluxes applied at the test section. The results indicated that the friction factor of both water and R134a can be predicted by the Hagen-Poiseuille equation for laminar flow and the modified Miller correlation for turbulent flow and early transition from laminar to turbulent flows. The heat transfer results of water and R134a were in good agreement with the conventional theory in the laminar flow region and lower than the Adam’s correlation for turbulent flow region which deviates from conventional theory.
Abstract: In this paper a study on the vibration of thin
cylindrical shells with ring supports and made of functionally
graded materials (FGMs) composed of stainless steel and
nickel is presented. Material properties vary along the
thickness direction of the shell according to volume fraction
power law. The cylindrical shells have ring supports which are
arbitrarily placed along the shell and impose zero lateral
deflections. The study is carried out based on third order shear
deformation shell theory (T.S.D.T). The analysis is carried out
using Hamilton-s principle. The governing equations of motion of
FGM cylindrical shells are derived based on shear deformation
theory. Results are presented on the frequency characteristics,
influence of ring support position and the influence of boundary
conditions. The present analysis is validated by comparing results
with those available in the literature.
Abstract: Electron back-scattered diffraction was used to follow the evolution of microstructure from the base metal to the stir zone (SZ) in a duplex stainless steel subjected to friction stir welding. In the stir zone (SZ), a continuous dynamic recrystallization (CDRX) was evidenced for ferrite, while it was suggested that a static recrystallization together with CDRX may occur for austenite. It was found that ferrite and austenite grains in the SZ take a typical shear texture of bcc and fcc materials respectively.
Abstract: In the present work, study of the vibration of thin cylindrical shells made of a functionally gradient material (FGM) composed of stainless steel and nickel is presented. Material properties are graded in the thickness direction of the shell according to volume fraction power law distribution. The objective is to study the natural frequencies, the influence of constituent volume fractions and the effects of boundary conditions on the natural frequencies of the FG cylindrical shell. The study is carried out using third order shear deformation shell theory. The governing equations of motion of FG cylindrical shells are derived based on shear deformation theory. Results are presented on the frequency characteristics, influence of constituent volume fractions and the effects of free-free boundary conditions.
Abstract: Adsorption of proteins onto a solid surface is believed to be the initial and controlling step in biofouling. A better knowledge of the fouling process can be obtained by controlling the formation of the first protein layer at a solid surface. A number of methods have been investigated to inhibit adsorption of proteins. In this study, the adsorption kinetics of
Abstract: This paper aims to scale up Dye-sensitized Solar Cell
(DSSC) production using a commonly available industrial material –
stainless steel - and industrial plasma equipment. A working DSSC
electrode formed by (1) coating titania nanotube (TiO2 NT) film on
304 stainless steel substrate using a plasma spray technique; then, (2)
filling the nano-pores of the TiO2 NT film using a TiF4 sol-gel method.
A DSSC device consists of an anode absorbed photosensitive dye
(N3), a transparent conductive cathode with platinum (Pt)
nano-catalytic particles adhered to its surface, and an electrolytic
solution sealed between the anode and the transparent conductive
cathode. The photo-current conversion efficiency of the DSSC sample
was tested under an AM 1.5 Solar Simulator. The sample has a short
current (Isc) of 0.83 mA cm-2, open voltage (Voc) of 0.81V, filling
factor (FF) of 0.52, and conversion efficiency (η) of 2.18% on a 0.16
cm2 DSSC work-piece.
Abstract: Constant amplitude fatigue crack growth (FCG) tests
were performed on dissimilar metal welded plates of Type 316L
Stainless Steel (SS) and IS 2062 Grade A Carbon steel (CS). The
plates were welded by TIG welding using SS E309 as electrode. FCG
tests were carried on the Side Edge Notch Tension (SENT)
specimens of 5 mm thickness, with crack initiator (notch) at base
metal region (BM), weld metal region (WM) and heat affected zones
(HAZ). The tests were performed at a test frequency of 10 Hz and at
load ratios (R) of 0.1 & 0.6. FCG rate was found to increase with
stress ratio for weld metals and base metals, where as in case of
HAZ, FCG rates were almost equal at high ΔK. FCG rate of HAZ of
stainless steel was found to be lowest at low and high ΔK. At
intermediate ΔK, WM showed the lowest FCG rate. CS showed
higher crack growth rate at all ΔK. However, the scatter band of data
was found to be narrow. Fracture toughness (Kc) was found to vary
in different locations of weldments. Kc was found lowest for the
weldment and highest for HAZ of stainless steel. A novel method of
characterizing the FCG behavior using an Infrared thermography
(IRT) camera was attempted. By monitoring the temperature rise at
the fast moving crack tip region, the amount of plastic deformation
was estimated.
Abstract: The carbon based coils with the nanometer scale have
the 3 dimension helix geometry. We synthesized the carbon nano-coils
by the use of chemical vapor deposition technique with iron and tin as
the catalysts. The fabricated coils have the external diameter of
ranging few hundred nm to few thousand nm. The Scanning
Electro-Microscope (SEM) and Tunneling Electro-Microscope has
shown detail images of the coil-s structure. The fabrication of the
carbon nano-coils can be grown on the metal and non-metal substrates,
such as the stainless steel and silicon substrates. Besides growth on the
flat substrate; they also can be grown on the stainless steel wires. After
the synthesis of the coils, the mechanical and electro-mechanical
property is measured. The experimental results were reported.
Abstract: Corrugated wire mesh laminates (CWML) are a class
of engineered open cell structures that have potential for applications
in many areas including aerospace and biomedical engineering. Two
different methods of fabricating corrugated wire mesh laminates from
stainless steel, one using a high temperature Lithobraze alloy and the
other using a low temperature Eutectic solder for joining the
corrugated wire meshes are described herein. Their implementation is
demonstrated by manufacturing CWML samples of 304 and 316
stainless steel (SST). It is seen that due to the facility of employing
wire meshes of different densities and wire diameters, it is possible to
create CWML laminates with a wide range of effective densities. The
fabricated laminates are tested under uniaxial compression. The
variation of the compressive yield strength with relative density of the
CWML is compared to the theory developed by Gibson and Ashby for
open cell structures [22]. It is shown that the compressive strength of
the corrugated wire mesh laminates can be described using the same
equations by using an appropriate value for the linear coefficient in the
Gibson-Ashby model.