Abstract: Pumping systems are an integral part of water desalination plants, their effective functioning is vital for the operation of a plant. In this research work, the reliability and availability of pressurized pumps in a reverse osmosis desalination plant are studied with the objective of finding configurations that provides optimal performance. Six configurations of a series system with different number of warm and cold standby components were examined. Closed form expressions for the mean time to failure (MTTF) and the long run availability are derived and compared under the assumption that the time between failures and repair times of the primary and standby components are exponentially distributed. Moreover, a cost/ benefit analysis is conducted in order to identify a configuration with the best performance and least cost. It is concluded that configurations with cold standby components are preferable especially when the pumps are of the size.
Abstract: In water pipeline systems, the flow control is an integrated part of the operation, for instance, opening and closing the valves, starting and stopping the pumps, when these operations very quickly performed, they shall cause the hydraulic transient phenomena, which may cause pump and, valve failures and catastrophic pipe ruptures. Fluid transient analysis is one of the more challenging and complicated flow problems in the design and the operation of water pipeline systems. Transient control has become an essential requirement for ensuring safe operation of water pipeline systems. An accurate analysis and suitable protection devices should be used to protect water pipeline systems. The fourth-order Runge-Kutta method has been used to solve the dynamic and continuity equations in the rigid column method, while the characteristics method used to solve these equations in the full elastic methods. This paper presents the problem of modeling and simulating of transient phenomena in conveying pipeline systems based on the rigid column and full elastic methods. Also, it provides the influence of using the protection devices to protect the pipeline systems from damaging due to the gain pressure which occur in the transient state. The results obtained provide that the model is an efficient tool for flow transient analysis and provide approximately identical results by using these two methods. Moreover; using the closed surge tank reduces the unfavorable effects of transients.
Abstract: Experimental study was conducted to assess personal welding fumes exposure toward welders during an aluminum metal inert gas (MIG) process. The welding process was carried out by a welding machine attached to a Computer Numerical Control (CNC) workbench. A dummy welder was used to replicate welder during welding works and was attached with sampling pumps and filter cassettes for welding fumes sampling. Direct reading instruments to measure air velocity, humidity, temperature and particulate matter with diameter size 10µm or less (PM10) were located behind the dummy welder and parallel to the neck collar level to make sure the measured welding fumes exposure were not being influenced by other factors. Welding fumes exposure during standing and sitting position with and without the usage of local exhaust ventilation (LEV) was investigated. Welding fume samples were then digested and analyzed by using inductively coupled plasma mass spectroscopy (ICP-MS) according to ASTM D7439-08 method. The results of the study showed the welding fume exposure during sitting was lower compared to standing position. LEV helped reduce aluminum and lead exposure to acceptable levels during standing position. However during sitting position reduction of exposure was smaller. It can be concluded that welder position and the correct positioning of LEV should be implemented for effective exposure reduction.
Abstract: This study aims to assess the potential of solar energy technology for improving access to water and hence the livelihood strategies of rural communities in Baja California Sur, Mexico. It focuses on livestock ranches and photovoltaic water-pumptechnology as well as other water extraction methods. The methodology used are the Sustainable Livelihoods and the Appropriate Technology approaches. A household survey was applied in June of 2006 to 32 ranches in the municipality, of which 22 used PV pumps; and semi-structured interviews were conducted. Findings indicate that solar pumps have in fact helped people improve their quality of life by allowing them to pursue a different livelihood strategy and that improved access to water -not necessarily as more water but as less effort to extract and collect it- does not automatically imply overexploitation of the resource; consumption is based on basic needs as well as on storage and pumping capacity. Justification for such systems lies in the avoidance of logistical problems associated to fossil fuels, PV pumps proved to be the most beneficial when substituting gasoline or diesel equipment but of dubious advantage if intended to replace wind or gravity systems. Solar water pumping technology-s main obstacle to dissemination are high investment and repairs costs and it is therefore not suitable for all cases even when insolation rates and water availability are adequate. In cases where affordability is not an obstacle it has become an important asset that contributes –by means of reduced expenses, less effort and saved time- to the improvement of livestock, the main livelihood provider for these ranches.
Abstract: This study presents energy saving in general-purpose
pumps widely used in industrial applications. Such pumps are
normally driven by a constant-speed electrical motor which in most
applications must support varying load conditions. This is equivalent
to saying the loading conditions mismatch the designed optimal
energy consumption requirements of the intended application thus
resulting in substantial energy losses. In the held experiments it was
indicated that combination of mechanical and electrical speed drives
can contribute to lower energy consumption in the pump without
negatively distorting the required performance indices of a typical
centrifugal pump at substantially lower energy consumption. The
registered energy savings were recorded to be within the 15-40%
margin. It was also indicated that although VSDs are installed at a
cost, the financial burden is balanced against the earnings resulting
from the associated energy savings.
Abstract: Statistics Canada stated that the wastewater treatment
facilities in most provinces are aging and passes 63% of their useful
life in 2007 the highest ratio among public infrastructure assets.
Currently, there is no standard condition rating system for wastewater
treatment plants that give a specific rating index that describe the
physical integrity of different infrastructure elements in the treatment
plant and its environmental performance. The main objective of this
study is to develop a condition-rating index for wastewater treatment
plants mainly activated sludge systems. The proposed WWTP CRI, is
based on dividing the treatment plant into its three treatment phases;
primary phase, secondary phase and the tertiary phase. The
condition-rating index will reflect the infrastructures state for each
phase, mainly tanks, pipes, blowers and pumps.
Abstract: Tip vortex cavitation is one of well known patterns of
cavitation phenomenon which occurs in axial pumps. This pattern of
cavitation occurs due to pressure difference between the pressure and
suction sides of blades of an axial pump. Since the pressure in the
pressure side of the blade is higher than the pressure in its suction
side, thus a very small portion of liquid flow flows back from
pressure side to the suction side. This fact is cause of tip vortex
cavitation and gap cavitation that may occur in axial pumps. In this
paper the results of our experimental investigation about movement
of tip vortex cavitation along blade edge due to reduction of pump
flow rate in an axial pump is reported. Results show that reduction of
pump flow rate in conjunction with increasing of outlet pressure
causes movement of tip vortex cavitation along blade edge towards
the blade tip. Results also show that by approaching tip vortex
cavitation to the blade tip, vortex tip pattern of cavitation replaces
with a cavitation phenomenon on the blade tip. Furthermore by
further reduction of pump flow rate and increasing of outlet pressure,
an unstable cavitation phenomenon occurs between each blade
leading edge and the next blade trailing edge.
Abstract: The impeller and the casing are the key components of
a centrifugal pump. Although there have been many studies on the
impeller and the volute casing of centrifugal pump, further study of the
volute casing to improve the performance of centrifugal pumps is
needed. In this paper, the effect of cross-sectional area on the
performance of volute casing was investigated using a commercial
CFD code. The performance characteristics, not only at the off-design
point but also for a full type model are required these days. So we
conducted numerical analysis for all operating points by using
complete geometry through transient analysis. Transient analysis on
the complete geometry of a real product has the advantage of
simulating realistic flow. The results of this study show the variation of
a performance curve by modifying the above-mentioned design
parameter.
Abstract: Pressure waves and Water Hammer occur in a
pumping system when valves are closed or opened suddenly or in
the case of sudden failure of pumps. Determination of maximum
water hammer is considered one of the most important technical
and economical items of which engineers and designers of
pumping stations and conveyance pipelines should take care.
Hammer Software is a recent application used to simulate water
hammer. The present study focuses on determining significance of
each input parameter of the application relative to the maximum
amount of water hammer estimated by the software. The study
determines estimated maximum water hammer variations due to
variations of input parameters including water temperature, pipe
type, thickness and diameter, electromotor rpm and power, and
moment of inertia of electromotor and pump. In our study,
Kuhrang Pumping Station was modeled using WaterGEMS
Software. The pumping station is characterized by total discharge
of 200 liters per second, dynamic height of 194 meters and 1.5
kilometers of steel conveyance pipeline and transports water to
Cheshme Morvarid for farmland irrigation. The model was run in
steady hydraulic condition and transferred to Hammer Software.
Then, the model was run in several unsteady hydraulic conditions
and sensitivity of maximum water hammer to each input parameter
was calculated. It is shown that parameters to which maximum
water hammer is most sensitive are moment of inertia of pump and
electromotor, diameter, type and thickness of pipe and water
temperature, respectively.
Abstract: Ground-source heat pumps achieve higher efficiencies
than conventional air-source heat pumps because they exchange heat
with the ground that is cooler in summer and hotter in winter than the
air environment. Earth heat exchangers are essential parts of the
ground-source heat pumps and the accurate prediction of their
performance is of fundamental importance. This paper presents the
development and validation of a numerical model through an
incompressible fluid flow, for the simulation of energy and
temperature changes in and around a U-tube borehole heat
exchanger. The FlexPDE software is used to solve the resulting
simultaneous equations that model the heat exchanger. The validated
model (through a comparison with experimental data) is then used to
extract conclusions on how various parameters like the U-tube
diameter, the variation of the ground thermal conductivity and
specific heat and the borehole filling material affect the temperature
of the fluid.
Abstract: The stability characteristics of water lubricated journal bearings having three axial grooves are obtained theoretically. In this lubricant (water) is fed under pressure from one end of the bearing, through the 3-axial grooves (groove angles may vary). These bearings can use the process fluid as the lubricant, as in the case of feed water pumps. The Reynolds equation is solved numerically by the finite difference method satisfying the boundary conditions. The stiffness and damping coefficient for various bearing number and eccentricity ratios, assuming linear pressure drop along the groove, shows that smaller groove angles better results.
Abstract: In this paper, the babbitting of a bearing in boiler feed pump of an electromotor has been studied. These bearings have an important role in reducing the shut down times in the pumps, compressors and turbines. The most conventional method in babbitting is casting as a melting method. The comparison between thermal spray and casting methods in babbitting shows that the thermal spraying babbitt layer has better performance and tribological behavior. The metallurgical and tribological analysis such as SEM, EDS and wet chemical analysis has been made in the Babbitt alloys and worn surfaces. Two type of babbitt materials: tinbase and lead-base babbitt was used. The benefits of thermally sprayed babbitt layers are completely clear especially in large bearings.
Abstract: In the upstream we place a piece of ring and rotate
it with 83Hz, 166Hz, 333Hz,and 666H to find the effect of the
periodic distortion.In the experiment this type of the perturbation
will not allow since the mechanical failure of any parts of the
equipment in the upstream will destroy the blade system. This type of
study will be only possible by CFD. We use two pumps NS32
(ENSAM) and three blades pump (Tamagawa Univ). The benchmark
computations were performed without perturbation parts, and confirm
the computational results well agreement in head-flow rate. We
obtained the pressure fluctuation growth rate that is representing the
global instability of the turbo-system. The fluctuating torque
components were 0.01Nm(5000rpm), 0.1Nm(10000rmp),
0.04Nm(20000rmp), 0.15Nm( 40000rmp) respectively. Only for
10000rpm(166Hz) the output toque was random, and it implies that it
creates unsteady flow by separations on the blades, and will reduce the
pressure loss significantly
Abstract: A mammal-s body can be seen as a blood vessel with
complex tunnels. When heart pumps blood periodically, blood runs
through blood vessels and rebounds from walls of blood vessels.
Blood pressure signals can be measured with complex but periodic
patterns. When an artery is clamped during a surgical operation, the
spectrum of blood pressure signals will be different from that of
normal situation. In this investigation, intestinal artery clamping
operations were conducted to a pig for simulating the situation of
intestinal blocking during a surgical operation. Similarity theory is a
convenient and easy tool to prove that patterns of blood pressure
signals of intestinal artery blocking and unblocking are surely
different. And, the algorithm of Hilbert Huang Transform can be
applied to extract the character parameters of blood pressure pattern.
In conclusion, the patterns of blood pressure signals of two different
situations, intestinal artery blocking and unblocking, can be
distinguished by these character parameters defined in this paper.
Abstract: This paper presents the experimental as well as the
simulated performance studies on the transcritical CO2 heat pumps
for simultaneous water cooling and heating; effects of water mass
flow rates and water inlet temperatures of both evaporator and gas
cooler on the cooling and heating capacities, system COP and water
outlets temperatures are investigated. Study shows that both the
water mass flow rate and inlet temperature have significant effect on
system performances. Test results show that the effect of evaporator
water mass flow rate on the system performances and water outlet
temperatures is more pronounced (COP increases 0.6 for 1 kg/min)
compared to the gas cooler water mass flow rate (COP increases 0.4
for 1 kg/min) and the effect of gas cooler water inlet temperature is
more significant (COP decreases 0.48 for given ranges) compared to
the evaporator water inlet temperature (COP increases 0.43 for given
ranges). Comparisons of experimental values with simulated results
show the maximum deviation of 5% for cooling capacity, 10% for
heating capacity, 16% for system COP. This study offers useful
guidelines for selecting appropriate water mass flow rate to obtain
required system performance.
Abstract: The high world interest given to the researches concerning the study of moderately halophilic solvent-tolerant bacteria isolated from marine polluted environments is due to their high biotechnological potential, and also to the perspective of their application in different remediation technologies. Using enrichment procedures, I isolated two moderately halophilic Gram-negative bacterial strains from seawater sample, which are tolerant to organic solvents. Cell tolerance, adhesion and cells viability of Aeromonas salmonicida IBBCt2 and Pseudomonas aeruginosa IBBCt3 in the presence of organic solvents depends not only on its physicochemical properties and its concentration, but also on the specific response of the cells, and the cellular response is not the same for these bacterial strains. n-hexane, n-heptane, propylbenzene, with log POW between 3.69 and 4.39, were less toxic for Aeromonas salmonicida IBBCt2 and Pseudomonas aeruginosa IBBCt3, compared with toluene, styrene, xylene isomers and ethylbenzene, with log POW between 2.64 and 3.17. The results indicated that Aeromonas salmonicida IBBCt2 is more susceptible to organic solvents than Pseudomonas aeruginosa IBBCt3. The mechanisms underlying solvent tolerance (e.g., the existance of the efflux pumps) in Aeromonas salmonicida IBBCt2 and Pseudomonas aeruginosa IBBCt3 it was also studied.
Abstract: Cavitation in pumps is known as the formation of
vapor bubbles due to pressure drop and collapsing these bubbles. In
some conditions, it has been observed that the formation of bubbles
occurs at the pressure side of centrifugal pump blades. In this study,
the formation of bubbles at the pressure side of blades has been
investigated. Water is used in this study as the fluid and performance
curves were depicted for different flow rates in an approximately
constant speed. The results show that when a centrifugal pump works
in low flow rates, a secondary flow namely recirculation starts to
begin. In this condition, separation of flow increases which causes
vortex formation and local pressure drop and eventually the
formation of vapor bubbles starts.
Abstract: Recent medical studies have investigated the importance of enteral feeding and the use of feeding pumps for recovering patients unable to feed themselves or gain nourishment and nutrients by natural means. The most of enteral feeding system uses a peristaltic tube pump. A peristaltic pump is a form of positive displacement pump in which a flexible tube is progressively squeezed externally to allow the resulting enclosed pillow of fluid to progress along it. The squeezing of the tube requires a precise and robust controller of the geared motor to overcome parametric uncertainty of the pumping system which generates due to a wide variation of friction and slip between tube and roller. So, this paper proposes fuzzy adaptive controller for the robust control of the peristaltic tube pump. This new adaptive controller uses a fuzzy multi-layered architecture which has several independent fuzzy controllers in parallel, each with different robust stability area. Out of several independent fuzzy controllers, the most suited one is selected by a system identifier which observes variations in the controlled system parameter. This paper proposes a design procedure which can be carried out mathematically and systematically from the model of a controlled system. Finally, the good control performance, accurate dose rate and robust system stability, of the developed feeding pump is confirmed through experimental and clinic testing.
Abstract: In order to compare the performance of the carbon dioxide and HFC-125 heat pumps for medium-and high-temperature heating, both heat pump cycles were optimized using a simulation method. To fairly compare the performance of the cycles by using different working fluids, each cycle was optimized from the viewpoint of heating COP by two design parameters. The first is the gas cooler exit temperature and the other is the ratio of the overall heat conductance of the gas cooler to the combined overall heat conductance of the gas cooler and the evaporator. The inlet and outlet temperatures of secondary fluid of the gas cooler were fixed at 40/90°C and 40/150°C.The results shows that the HFC-125 heat pump has 6% higher heating COP than carbon dioxide heat pump when the heat sink exit temperature is fixed at 90ºC, while the latter outperforms the former when the heat sink exit temperature is fixed at 150ºC under the simulation conditions considered in the present study.
Abstract: Nowadays, desalination of salt water is considered an important industrial process. In many parts of the world, particularly in the gulf countries, the multi-stage flash (MSF) water desalination has an essential contribution in the production of fresh water. In this study, a simple mathematical model is defined to design a MSF desalination system and the feasibility of using the MSF desalination process in proximity of a 42 MW power plant is investigated. This power plant can just provide 10 ton/h superheated steam from low pressure (LP) section of heat recovery steam generator (HRSG) for thermal desalting system. The designed MSF system with gained output ratio (GOR) of 10.3 has 24 flashing stages and can produce 2480 ton/d of fresh water. The expected performance characteristics of the designed MSF desalination plant are determined. In addition, the effect of motive water pressure on the amount of non-condensable gases removed by water jet vacuum pumps is investigated.