Abstract: Cavitation in pumps is known as the formation of
vapor bubbles due to pressure drop and collapsing these bubbles. In
some conditions, it has been observed that the formation of bubbles
occurs at the pressure side of centrifugal pump blades. In this study,
the formation of bubbles at the pressure side of blades has been
investigated. Water is used in this study as the fluid and performance
curves were depicted for different flow rates in an approximately
constant speed. The results show that when a centrifugal pump works
in low flow rates, a secondary flow namely recirculation starts to
begin. In this condition, separation of flow increases which causes
vortex formation and local pressure drop and eventually the
formation of vapor bubbles starts.
Abstract: The interaction of the blade tip with the casing
boundary layer and the leakage flow may lead to a kind of cavitation
namely tip vortex cavitation. In this study, the onset of tip vortex
cavitation was experimentally investigated in an axial flow pump.
For a constant speed and a fixed angle of attack and by changing the
flow rate, the pump head, input power, output power and efficiency
were calculated and the pump characteristic curves were obtained.
The cavitation phenomenon was observed with a camera and a
stroboscope. Finally, the critical flow region, which tip vortex
cavitation might have occurred, was identified. The results show that
just by adjusting the flow rate, out of the specified region, the
possibility of occurring tip vortex cavitation, decreases to a great
extent.