Abstract: Hazard management that can prevent fatal accidents and property losses is a fundamental process during the buildings’ construction stage. However, due to lack of safety supervision resources and operational pressures, the conduction of hazard management is poor and ineffective in China. In order to improve the quality of construction safety management, it is critical to explore the use of information technologies to ensure that the process of hazard management is efficient and effective. After exploring the existing problems of construction hazard management in China, this paper develops the griddization management model for construction hazard management. First, following the knowledge grid infrastructure, the griddization computing infrastructure for construction hazards management is designed which includes five layers: resource entity layer, information management layer, task management layer, knowledge transformation layer and application layer. This infrastructure will be as the technical support for realizing grid management. Second, this study divides the construction hazards into grids through city level, district level and construction site level according to grid principles. Last, a griddization management process including hazard identification, assessment and control is developed. Meanwhile, all stakeholders of construction safety management, such as owners, contractors, supervision organizations and government departments, should take the corresponding responsibilities in this process. Finally, a case study based on actual construction hazard identification, assessment and control is used to validate the effectiveness and efficiency of the proposed griddization management model. The advantage of this designed model is to realize information sharing and cooperative management between various safety management departments.
Abstract: In this paper, a single phase soft switched Zero Voltage Transition and Zero Current Transition (ZVT-ZCT) Power Factor Correction (PFC) boost converter is proposed. In the proposed PFC converter, the main switch turns on with ZVT and turns off with ZCT without any additional voltage or current stresses. Auxiliary switch turns on and off with zero current switching (ZCS). Also, the main diode turns on with zero voltage switching (ZVS) and turns off with ZCS. The proposed converter has features like low cost, simple control and structure. The output current and voltage are controlled by the proposed PFC converter in wide line and load range. The theoretical analysis of converter is clarified and the operating steps are given in detail. The simulation results of converter are obtained for 500 W and 100 kHz. It is observed that the semiconductor devices operate with soft switching (SS) perfectly. So, the switching power losses are minimum. Also, the proposed converter has 0.99 power factor with sinusoidal current shape.
Abstract: The objective of this research is to mitigate and prevent
the alkali silica reactivity (ASR) in highway construction projects.
ASR is a deleterious reaction initiated when the silica content of the
aggregate reacts with alkali hydroxides in cement in the presence of
relatively high moisture content. The ASR results in the formation of
an expansive white colored gel-like material which forms the
destructive tensile stresses inside hardened concrete. In this research, different types of local aggregates available in the
State of Arkansas were mixed and mortar bars were poured according
to the ASTM specifications. Mortar bars expansion was measured
versus time and aggregates with potential ASR problems were
detected. Different types of supplementary cementitious materials
(SCMs) were used in remixing mortar bars with highly reactive
aggregates. Length changes for remixed bars proved that different
types of SCMs can be successfully used in reducing the expansive
effect of ASR. SCMs percentage by weight is highly dependent on
the SCM type. The result of this study will help avoiding future
losses due to ASR cracking in construction project and reduce the
maintenance, repair, and replacement budgets required for highways
network.
Abstract: The Flexible AC Transmission System (FACTS)
technology is a new advanced solution that increases the reliability
and provides more flexibility, controllability, and stability of a power
system. The Unified Power Flow Controller (UPFC), as the most
versatile FACTS device for regulating power flow, is able to control
respectively transmission line real power, reactive power, and node
voltage. The main purpose of this paper is to analyze the effect of the
UPFC on the load flow, the power losses, and the voltage stability
using NEPLAN software modules, Newton-Raphson load flow is
used for the power flow analysis and the modal analysis is used for
the study of the voltage stability. The simulation was carried out on
the IEEE 14-bus test system.
Abstract: The power electronic components within Electric Vehicles (EV) need to operate in several important modes. Some modes directly influence safety, while others influence vehicle performance. Given the variety of functions and operational modes required of the power electronics, it needs to meet efficiency requirements to minimize power losses. Another challenge in the control and construction of such systems is the ability to support bidirectional power flow. This paper considers the construction, operation, and feasibility of available converters for electric vehicles with feasible configurations of electrical buses and loads. This paper describes logic and control signals for the converters for different operations conditions based on the efficiency and energy usage bases.
Abstract: A number of studies have been conducted recently to
investigate the influence of randomly oriented fibers on some
engineering properties of cohesive and cohesionless soils. However,
few studies have been carried out on freezing-thawing behavior of
fine-grained soils modified with discrete fiber inclusions and additive
materials. This experimental study was performed to investigate the
effect of randomly distributed polypropylene fibers (PP) and some
additive materials [e.g.., borogypsum (BG), fly ash (FA) and cement
(C)] on freezing-thawing durability (mass losses) of a fine-grained
soil for 6, 12, and 18 cycles. The Taguchi method was applied to the
experiments and a standard L9 orthogonal array (OA) with four
factors and three levels were chosen. A series of freezing-thawing
tests were conducted on each specimen. 0-20% BG, 0-20% FA, 0-
0.25% PP and 0-3% of C by total dry weight of mixture were used in
the preparation of specimens. Experimental results showed that the
most effective materials for the freezing-thawing durability (mass
losses) of the samples were borogypsum and fly ash. The values of
mass losses for 6, 12 and 18 cycles in optimum conditions were
16.1%, 5.1% and 3.6%, respectively.
Abstract: A solar receiver is designed for operation under
extremely uneven heat flux distribution, cyclic weather, and cloud
transient cycle conditions, which can include large thermal stress and
even receiver failure. In this study, the effect of different oil velocity
on convection coefficient factor and impact of wind velocity on local
Nusselt number by Finite Volume Method will be analyzed. This
study is organized to give an overview of the numerical modeling
using a MATLAB software, as an accurate, time efficient and
economical way of analyzing the heat transfer trends over stationary
receiver tube for different Reynolds number. The results reveal when
oil velocity is below 0.33m/s, the value of convection coefficient is
negligible at low temperature. The numerical graphs indicate that
when oil velocity increases up to 1.2 m/s, heat convection coefficient
increases significantly. In fact, a reduction in oil velocity causes a
reduction in heat conduction through the glass envelope. In addition,
the different local Nusselt number is reduced when the wind blows
toward the concave side of the collector and it has a significant effect
on heat losses reduction through the glass envelope.
Abstract: A method of effective planning and control of
industrial facility energy consumption is offered. The method allows
optimally arranging the management and full control of complex
production facilities in accordance with the criteria of minimal
technical and economic losses at the forecasting control. The method
is based on the optimal construction of the power efficiency
characteristics with the prescribed accuracy. The problem of optimal
designing of the forecasting model is solved on the basis of three
criteria: maximizing the weighted sum of the points of forecasting
with the prescribed accuracy; the solving of the problem by the
standard principles at the incomplete statistic data on the basis of
minimization of the regularized function; minimizing the technical
and economic losses due to the forecasting errors.
Abstract: A Multi-dimensional computational fluid dynamics
(CFD) two-phase model was developed with the aim to simulate
the in-core coolant circuit of a pressurized heavy water reactor
(PHWR) of a commercial nuclear power plant (NPP). Due to the
fact that this PHWR is a Reactor Pressure Vessel type (RPV),
three-dimensional (3D) detailed modelling of the large reservoirs of
the RPV (the upper and lower plenums and the downcomer) were
coupled with an in-house finite volume one-dimensional (1D) code
in order to model the 451 coolant channels housing the nuclear fuel.
Regarding the 1D code, suitable empirical correlations for taking into
account the in-channel distributed (friction losses) and concentrated
(spacer grids, inlet and outlet throttles) pressure losses were used.
A local power distribution at each one of the coolant channels
was also taken into account. The heat transfer between the coolant
and the surrounding moderator was accurately calculated using a
two-dimensional theoretical model. The implementation of subcooled
boiling and condensation models in the 1D code along with the use
of functions for representing the thermal and dynamic properties of
the coolant and moderator (heavy water) allow to have estimations
of the in-core steam generation under nominal flow conditions for a
generic fission power distribution. The in-core mass flow distribution
results for steady state nominal conditions are in agreement with the
expected from design, thus getting a first assessment of the coupled
1/3D model. Results for nominal condition were compared with
those obtained with a previous 1/3D single-phase model getting more
realistic temperature patterns, also allowing visualize low values of
void fraction inside the upper plenum. It must be mentioned that the
current results were obtained by imposing prescribed fission power
functions from literature. Therefore, results are showed with the aim
of point out the potentiality of the developed model.
Abstract: Revenue leakages are one of the major challenges
manufacturers face in production processes, as most of the input
materials that should emanate as products from the lines are lost as
waste. Rather than generating income from material input which is
meant to end-up as products, losses are further incurred as costs in
order to manage waste generated. In addition, due to the lack of a
clear view of the flow of resources on the lines from input to output
stage, acquiring information on the true cost of waste generated have
become a challenge. This has therefore given birth to the
conceptualization and implementation of waste minimization
strategies by several manufacturing industries. This paper reviews the
principles and applications of three environmental management
accounting tools namely Activity-based Costing (ABC), Life-Cycle
Assessment (LCA) and Material Flow Cost Accounting (MFCA) in
the manufacturing industry and their effectiveness in curbing revenue
leakages. The paper unveils the strengths and limitations of each of
the tools; beaming a searchlight on the tool that could allow for
optimal resource utilization, transparency in production process as
well as improved cost efficiency. Findings from this review reveal
that MFCA may offer superior advantages with regards to the
provision of more detailed information (both in physical and
monetary terms) on the flow of material inputs throughout the
production process compared to the other environmental accounting
tools. This paper therefore makes a case for the adoption of MFCA as
a viable technique for the identification and reduction of waste in
production processes, and also for effective decision making by
production managers, financial advisors and other relevant
stakeholders.
Abstract: An industrial system for the production of white
liquor of a paper industry, Klabin Paraná Papéis, formed by ten
reactors was modeled, simulated, and analyzed. The developed model
considered possible water losses by evaporation and reaction, in
addition to variations in volumetric flow of lime mud across the
reactors due to composition variations. The model predictions agreed
well with the process measurements at the plant and the results
showed that the slaking reaction is nearly complete at the third
causticizing reactor, while causticizing ends by the seventh reactor.
Water loss due to slaking reaction and evaporation occurs more
pronouncedly in the slaking reaction than in the final causticizing
reactors; nevertheless, the lime mud flow remains nearly constant
across the reactors.
Abstract: High moisture content in fruits generates post-harvest
problems such as mechanical, biochemical, microbial and physical
losses. Dehydration, which is based on the reduction of water activity
of the fruit, is a common option for overcoming such losses.
However, regular hot air drying could affect negatively the quality
properties of the fruit due to the long residence time at high
temperature. Power ultrasound (US) application during the
convective drying has been used as a novel method able to enhance
drying rate and, consequently, to decrease drying time. In the present
study, a new approach was tested to evaluate the effect of US on the
drying time, the final antioxidant activity (AA) and the total
polyphenol content (TPC) of banana slices (BS), mango slices (MS)
and guava slices (GS). There were also studied the drying kinetics
with nine different models from which water effective diffusivities
(Deff) (with or without shrinkage corrections) were calculated.
Compared with the corresponding control tests, US assisted drying
for fruit slices showed reductions in drying time between 16.23 and
30.19%, 11.34 and 32.73%, and 19.25 and 47.51% for the MS, BS
and GS respectively. Considering shrinkage effects, Deff calculated
values ranged from 1.67*10-10 to 3.18*10-10 m2/s, 3.96*10-10 and
5.57*10-10 m2/s and 4.61*10-10 to 8.16*10-10 m2/s for the BS, MS and
GS samples respectively. Reductions of TPC and AA (as DPPH)
were observed compared with the original content in fresh fruit data
in all kinds of drying assays.
Abstract: Drought is one of the most serious problems posing a
grave threat to cereals production including maize. Maize
improvement in drought-stress tolerance poses a great challenge as
the global need for food and bio-energy increases. Thus, the current
study was planned to explore the variations and determine the
performance of target traits of maize hybrids at grain growth stage
under drought conditions during 2014 under Adana, Mediterranean
climate conditions, Turkey. Maize hybrids (Sancia, Indaco,
71May69, Aaccel, Calgary, 70May82, 72May80) were evaluated
under (irrigated and water stress). Results revealed that, grain yield
and yield traits had a negative effects because of water stress
conditions compared with the normal irrigation. As well as, based on
the result under normal irrigation, the maximum biological yield and
harvest index were recorded. According to the differences among
hybrids were found that, significant differences were observed among
hybrids with respect to yield and yield traits under current research. Based on the results, grain weight had more effect on grain yield
than grain number during grain filling growth stage under water
stress conditions. In this concern, according to low drought
susceptibility index (less grain yield losses), the hybrid (Indaco) was
more stable in grain number and grain weight. Consequently, it may
be concluded that this hybrid would be recommended for use in the
future breeding programs for production of drought tolerant hybrids.
Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: Efficient use of energy, the increase in demand of
energy and also with the reduction of natural energy sources, has
improved its importance in recent years. Most of the losses in the
system from electricity produced until the point of consumption is
mostly composed by the energy distribution system. In this study,
analysis of the resulting loss in power distribution transformer and
distribution power cable is realized which are most of the losses in
the distribution system. Transformer losses in the real distribution
system are analyzed by CYME Power Engineering Software
program. These losses are disclosed for different voltage levels and
different loading conditions.
Abstract: To tackle the air pollution issues, Plug-in Hybrid
Electric Vehicles (PHEVs) are proposed as an appropriate solution.
Charging a large amount of PHEV batteries, if not controlled, would
have negative impacts on the distribution system. The control process
of charging of these vehicles can be centralized in parking lots that
may provide a chance for better coordination than the individual
charging in houses. In this paper, an optimization-based approach is
proposed to determine the optimum PHEV parking capacities in
candidate nodes of the distribution system. In so doing, a profile for
charging and discharging of PHEVs is developed in order to flatten
the network load profile. Then, this profile is used in solving an
optimization problem to minimize the distribution system losses. The
outputs of the proposed method are the proper place for PHEV
parking lots and optimum capacity for each parking. The application
of the proposed method on the IEEE-34 node test feeder verifies the
effectiveness of the method.
Abstract: In this paper, influence of harmonics on medium
voltage distribution system of Bogazici Electricity Distribution Inc.
(BEDAS) which takes place at Istanbul/Turkey is investigated. A ring
network consisting of residential loads is taken into account for this
study. Real system parameters and measurement results are used for
simulations. Also, probable working conditions of the system are
analyzed for 50%, 75%, and 100% loading of transformers with
similar harmonic contents. Results of the study are exhibited the
influence of nonlinear loads on %THDV, P.F. and technical losses of
the medium voltage distribution system.
Abstract: Acoustic properties of polymeric liquids are high
sensitive to free gas traces in the form of fine bubbles. Their presence
is typical for such liquids because of chemical reactions, small
wettability of solid boundaries, trapping of air in technological
operations, etc. Liquid temperature influences essentially its
rheological properties, which may have an impact on the bubble
pulsations and sound propagation in the system. The target of the
paper is modeling of the liquid temperature effect on single bubble
dynamics and sound dispersion and attenuation in polymeric solution
with spherical gas bubbles. The basic sources of attenuation (heat
exchange between gas in microbubbles and surrounding liquid,
rheological and acoustic losses) are taken into account. It is supposed
that in the studied temperature range the interface mass transfer has a
minor effect on bubble dynamics. The results of the study indicate
that temperature raise yields enhancement of bubble pulsations and
increase in sound attenuation in the near-resonance range and may
have a strong impact on sound dispersion in the liquid-bubble
mixture at frequencies close to the resonance frequency of bubbles.
Abstract: In a practical power system, the power plants are not
located at the same distance from the center of loads and their fuel
costs are different. Also, under normal operating conditions, the
generation capacity is more than the total load demand and losses.
Thus, there are many options for scheduling generation. In an
interconnected power system, the objective is to find the real and
reactive power scheduling of each power plant in such a way as to
minimize the operating cost. This means that the generator’s real and
reactive powers are allowed to vary within certain limits so as to meet
a particular load demand with minimum fuel cost. This is called
optimal power flow problem. In this paper, Economic Load Dispatch
(ELD) of real power generation is considered. Economic Load
Dispatch (ELD) is the scheduling of generators to minimize total
operating cost of generator units subjected to equality constraint of
power balance within the minimum and maximum operating limits of
the generating units. In this paper, genetic algorithms are considered.
ELD solutions are found by solving the conventional load flow
equations while at the same time minimizing the fuel costs.
Abstract: In statistics parameter theory, usually the
parameter estimations have two kinds, one is the least-square
estimation (LSE), and the other is the best linear unbiased
estimation (BLUE). Due to the determining theorem of
minimum variance unbiased estimator (MVUE), the parameter
estimation of BLUE in linear model is most ideal. But since
the calculations are complicated or the covariance is not
given, people are hardly to get the solution. Therefore, people
prefer to use LSE rather than BLUE. And this substitution
will take some losses. To quantize the losses, many scholars
have presented many kinds of different relative efficiencies in
different views. For the linear weighted regression model, this
paper discusses the relative efficiencies of LSE of β to BLUE
of β. It also defines two new relative efficiencies and gives
their lower bounds.