Abstract: Automatic determination of blood in less bright or
noisy capsule endoscopic images is difficult due to low S/N ratio.
Especially it may not be accurate to analyze these images due to the
influence of external disturbance. Therefore, we proposed detection
methods that are not dependent only on color bands. In locating
bleeding regions, the identification of object outlines in the frame and
features of their local colors were taken into consideration. The results
showed that the capability of detecting bleeding was much improved.
Abstract: A learning management system (commonly
abbreviated as LMS) is a software application for the administration,
documentation, tracking, and reporting of training programs,
classroom and online events, e-learning programs, and training
content (Ellis 2009). (Hall 2003) defines an LMS as \"software that
automates the administration of training events. All Learning
Management Systems manage the log-in of registered users, manage
course catalogs, record data from learners, and provide reports to
management\". Evidence of the worldwide spread of e-learning in
recent years is easy to obtain. In April 2003, no fewer than 66,000
fully online courses and 1,200 complete online programs were listed
on the TeleCampus portal from TeleEducation (Paulsen 2003). In the
report \" The US market in the Self-paced eLearning Products and
Services:2010-2015 Forecast and Analysis\" The number of student
taken classes exclusively online will be nearly equal (1% less) to the
number taken classes exclusively in physical campuses. Number of
student taken online course will increase from 1.37 million in 2010 to
3.86 million in 2015 in USA. In another report by The Sloan
Consortium three-quarters of institutions report that the economic
downturn has increased demand for online courses and programs.
Abstract: Bleeding in the digestive duct is an important diagnostic parameter for patients. Blood in the endoscopic image can be determined by investigating the color tone of blood due to the degree of oxygenation, under- or over- illumination, food debris and secretions, etc. However, we found that how to pre-process raw images obtained from the capsule detectors was very important. We applied various image process methods suitable for the capsule endoscopic image in order to remove noises and unbalanced sensitivities for the image pixels. The results showed that much improvement was achieved by additional pre-processing techniques on the algorithm of determining bleeding areas.
Abstract: Owing the fact that optimization of business process
is a crucial requirement to navigate, survive and even thrive in
today-s volatile business environment, this paper presents a
framework for selecting a best-fit optimization package for solving
complex business problems. Complexity level of the problem and/or
using incorrect optimization software can lead to biased solutions of
the optimization problem. Accordingly, the proposed framework
identifies a number of relevant factors (e.g. decision variables,
objective functions, and modeling approach) to be considered during
the evaluation and selection process. Application domain, problem
specifications, and available accredited optimization approaches are
also to be regarded. A recommendation of one or two optimization
software is the output of the framework which is believed to provide
the best results of the underlying problem. In addition to a set of
guidelines and recommendations on how managers can conduct an
effective optimization exercise is discussed.
Abstract: Image processing for capsule endoscopy requires large
memory and it takes hours for diagnosis since operation time is
normally more than 8 hours. A real-time analysis algorithm of capsule
images can be clinically very useful. It can differentiate abnormal
tissue from health structure and provide with correlation information
among the images. Bleeding is our interest in this regard and we
propose a method of detecting frames with potential bleeding in
real-time. Our detection algorithm is based on statistical analysis and
the shapes of bleeding spots. We tested our algorithm with 30 cases of
capsule endoscopy in the digestive track. Results were excellent where
a sensitivity of 99% and a specificity of 97% were achieved in
detecting the image frames with bleeding spots.
Abstract: A 2.4GHz (RF) down conversion Gilbert Cell mixer,
implemented in a 0.18-μm CMOS technology with a 1.8V supply, is
presented. Current bleeding (charge injection) technique has been
used to increase the conversion gain and the linearity of the mixer.
The proposed mixer provides 10.75 dB conversion gain ( C G ) with
14.3mw total power consumption. The IIP3 and 1-dB compression
point of the mixer are 8dbm and -4.6dbm respectively, at 300 MHz
IF frequencies. Comparing the current design against the
conventional mixer design, demonstrates better performance in the
conversion gain, linearity, noise figure and port-to-port isolation.
Abstract: Culinary culture differences can cause health
problems for international tourists in Thailand. This paper drew upon
data collected from an international tourist survey conducted in
Bangkok, Thailand during summer of 2012. Summer is the period
that a variety food safety issues and incidents are often publicized in
Thailand. The survey targeted European Union tourists- concerns
toward a variety of food safety issues that they encountered during
their trip in Thailand. A total of 400 respondents were elicited as data
input for t-test, and one way ANOVA test. The findings revealed an
astonishing result that up to 46.5 percent of respondents were sick at
least one time or more in Thailand. However, the majority of
respondents trusted that the Thai hotel and Thai restaurants would
ensure food safety, but they did not trust street vendors to ensure food
safety. The level of food safety concern can be ranked from most
concern to least concern by using the value of mean scores as
follows: 1) artificial coloring, 2) use of preservatives, 3) antibiotics,
4) growth hormones, 5) chemical residues, and 6) bacterial
contamination. The overall mean score for level of concerns was
3.493 with standard deviation of 1.677 which did not indicate a very
high level of concern. In addition, the result for t-test and one way
ANOVA test revealed that there was not much effect from the
demographic differences to level of food safety concerns.
Abstract: Automatic detection of bleeding is of practical
importance since capsule endoscopy produces an extremely large
number of images. Algorithm development of bleeding detection in
the digestive tract is difficult due to different contrasts among the
images, food dregs, secretion and others. In this study, were assigned
weighting factors derived from the independent features of the
contrast and brightness between bleeding and normality. Spectral
analysis based on weighting factors was fast and accurate. Results
were a sensitivity of 87% and a specificity of 90% when the accuracy
was determined for each pixel out of 42 endoscope images.
Abstract: A design flow of multi-standard down-conversion
CMOS mixers for three modern standards: Global System Mobile,
Digital Enhanced Cordless Telephone and Universal Mobile
Telecommunication Systems is presented. Three active mixer-s
structures are studied. The first is based on the Gilbert cell which
gives a tolerable noise figure and linearity with a low conversion
gain. The second and third structures use the current bleeding and
charge injection techniques in order to increase the conversion gain.
An improvement of about 2 dB of the conversion gain is achieved
without a considerable degradation of the other characteristics. The
models used for noise figure, conversion gain and IIP3 used are
studied. This study describes the nature of trade-offs inherent in such
structures and gives insights that help in identifying which structure
is better for given conditions.