Abstract: The readiness potential in brain waves is a brain activity related with an intention whose potential arises even before its conscious intention. This study was carried out in order to understand the generation and mechanism of the readiness potential more. The experiment with two subjects was conducted in two ways following the Oddball task protocol. Firstly, auditory stimuli were randomly presented to the subjects. The subject was allowed to press the keyboard with the right index finger only when the subject heard the target stimulus but not the standard stimulus. Secondly, unlike the first one, the auditory stimuli were randomly presented, and the subjects pressed the keyboard in the same manner, but at the same time with grasping action of the left hand. The readiness potential showed up for both of these experiments. In the first Oddball experiment, the readiness potential was detected only when the target stimulus was presented. However, in the second Oddball experiment with the left hand action of grasping something, the readiness potential was detected at the presentation of for both standard and target stimuli. However, detected readiness potentials with the target stimuli were larger than those of the standard stimuli. We found an interesting phenomenon that the readiness potential was able to be detected even the standard stimulus. This indicates that motor-related readiness potentials can be generated only by the intention to move. These results present a new perspective in psychology and brain engineering since subconscious brain action may be prior to conscious recognition of the intention.
Abstract: EEG is a very complex signal with noises and other bio-potential interferences. EOG is the most distinct interfering signal when EEG signals are measured and analyzed. It is very important how to process raw EEG signals in order to obtain useful information. In this study, the EEG signal processing techniques such as EOG filtering and outlier removal were examined to minimize unwanted EOG signals and other noises. The two different mental states of resting and focusing were examined through EEG analysis. A focused state was induced by letting subjects to watch a red dot on the white screen. EEG data for 32 healthy subjects were measured. EEG data after 60-Hz notch filtering were processed by a commercially available EOG filtering and our presented algorithm based on the removal of outliers. The ratio of beta wave to theta wave was used as a parameter for determining the degree of focusing. The results show that our algorithm was more appropriate than the existing EOG filtering.
Abstract: Event-related potential (ERP) is one of the useful tools for investigating cognitive reactions. In this study, the potential of ERP components detected after auditory and visual stimuli was examined. Subjects were asked to respond upon stimuli that were of three categories; Target, Non-Target and Standard stimuli. The ERP after stimulus was measured. In the experiment of visual evoked potentials (VEPs), the subjects were asked to gaze at a center point on the monitor screen where the stimuli were provided by the reversal pattern of the checkerboard. In consequence of the VEP experiments, we observed consistent reactions. Each peak voltage could be measured when the ensemble average was applied. Visual stimuli had smaller amplitude and a longer latency compared to that of auditory stimuli. The amplitude was the highest with Target and the smallest with Standard in both stimuli.
Abstract: Analysis of EEG brainwave provides information on mental or emotional states. One of the particular states that can have various applications in human machine interface (HMI) is concentration. 8-channel EEG signals were measured and analyzed. The concentration index was compared during resting and concentrating periods. Among eight channels, locations the frontal lobe (Fp1 and Fp2) showed a clear increase of the concentration index during concentration regardless of subjects. The rest six channels produced conflicting observations depending on subjects. At this time, it is not clear whether individual difference or how to concentrate made these results for the rest six channels. Nevertheless, it is expected that Fp1 and Fp2 are promising locations for extracting control signal for HMI applications.
Abstract: Intrabody communication (IBC) is a new way of transferring data using human body as a medium. Minute current can travel though human body without any harm. IBC can remove electrical wires for human area network. IBC can be also a secure communication network system unlike wireless networks which can be accessed by anyone with bad intentions. One of the IBC systems is based on frequency shift keying modulation where individual data are transmitted to the external devices for the purpose of secure access such as digital door lock. It was found that the quality of IBC data transmission was heavily dependent on ground configurations of electronic circuits. Reliable IBC transmissions were not possible when both of the transmitter and receiver used batteries as circuit power source. Transmission was reliable when power supplies were used as power source for both transmitting and receiving sites because the common ground was established through the grounds of instruments such as power supply and oscilloscope. This was due to transmission dipole size and the ground effects of floor and AC power line. If one site used battery as power source and the other site used the AC power as circuit power source, transmission was possible.
Abstract: A game using electro-oculography (EOG) as control signal was introduced in this study. Various EOG signals are generated by eye movements. Even though EOG is a quite complex type of signal, distinct and separable EOG signals could be classified from horizontal and vertical, left and right eye movements. Proper signal processing was incorporated since EOG signal has very small amplitude in the order of micro volts and contains noises influenced by external conditions. Locations of the electrodes were set to be above and below as well as left and right positions of the eyes. Four control signals of up, down, left and right were generated. A microcontroller processed signals in order to simulate a DDR game. A LCD display showed arrows falling down with four different head directions. This game may be used as eye exercise for visual concentration and acuity. Our proposed EOG control signal can be utilized in many other applications of human machine interfaces such as wheelchair, computer keyboard and home automation.
Abstract: Data security in u-Health system can be an important
issue because wireless network is vulnerable to hacking. However, it is
not easy to implement a proper security algorithm in an embedded
u-health monitoring because of hardware constraints such as low
performance, power consumption and limited memory size and etc. To
secure data that contain personal and biosignal information, we
implemented several security algorithms such as Blowfish, data
encryption standard (DES), advanced encryption standard (AES) and
Rivest Cipher 4 (RC4) for our u-Health monitoring system and the
results were successful. Under the same experimental conditions, we
compared these algorithms. RC4 had the fastest execution time.
Memory usage was the most efficient for DES. However, considering
performance and safety capability, however, we concluded that AES
was the most appropriate algorithm for a personal u-Health monitoring
system.
Abstract: Wireless capsule endoscopy provides real-time images in the digestive tract. Capsule images are usually low resolution and are diverse images due to travel through various regions of human body. Color information has been a primary reference in predicting abnormalities such as bleeding. Often color is not sufficient for this purpose. In this study, we took morphological shapes into account as additional, but important criterion. First, we processed gastric images in order to indentify various objects in the image. Then, we analyzed color information in the object. In this way, we could remove unnecessary information and increase the accuracy. Compared to our previous investigations, we could handle images of various degrees of brightness and improve our diagnostic algorithm.
Abstract: Automatic determination of blood in less bright or
noisy capsule endoscopic images is difficult due to low S/N ratio.
Especially it may not be accurate to analyze these images due to the
influence of external disturbance. Therefore, we proposed detection
methods that are not dependent only on color bands. In locating
bleeding regions, the identification of object outlines in the frame and
features of their local colors were taken into consideration. The results
showed that the capability of detecting bleeding was much improved.
Abstract: Bleeding in the digestive duct is an important diagnostic parameter for patients. Blood in the endoscopic image can be determined by investigating the color tone of blood due to the degree of oxygenation, under- or over- illumination, food debris and secretions, etc. However, we found that how to pre-process raw images obtained from the capsule detectors was very important. We applied various image process methods suitable for the capsule endoscopic image in order to remove noises and unbalanced sensitivities for the image pixels. The results showed that much improvement was achieved by additional pre-processing techniques on the algorithm of determining bleeding areas.
Abstract: A wrist-band type biosignal measurement system and its data transfer through human body communication (HBC) were investigated. An HBC method based on pulses of ultra-wide band instead of using frequency or amplitude modulations was studied and implemented since the system became very compact and it was more suited for personal or mobile health monitoring. Our system measured photo-plethysmogram (PPG) and measured PPG signals were transmitted through a finger to a monitoring PC system. The device was compact and low-power consuming. HBC communication has very strongsecurity measures since it does not use wireless network.Furthermore, biosignal monitoring system becomes handy because it does not need to have wire connections.
Abstract: Image processing for capsule endoscopy requires large
memory and it takes hours for diagnosis since operation time is
normally more than 8 hours. A real-time analysis algorithm of capsule
images can be clinically very useful. It can differentiate abnormal
tissue from health structure and provide with correlation information
among the images. Bleeding is our interest in this regard and we
propose a method of detecting frames with potential bleeding in
real-time. Our detection algorithm is based on statistical analysis and
the shapes of bleeding spots. We tested our algorithm with 30 cases of
capsule endoscopy in the digestive track. Results were excellent where
a sensitivity of 99% and a specificity of 97% were achieved in
detecting the image frames with bleeding spots.
Abstract: Automatic detection of bleeding is of practical
importance since capsule endoscopy produces an extremely large
number of images. Algorithm development of bleeding detection in
the digestive tract is difficult due to different contrasts among the
images, food dregs, secretion and others. In this study, were assigned
weighting factors derived from the independent features of the
contrast and brightness between bleeding and normality. Spectral
analysis based on weighting factors was fast and accurate. Results
were a sensitivity of 87% and a specificity of 90% when the accuracy
was determined for each pixel out of 42 endoscope images.
Abstract: In this study, we introduced a communication system
where human body was used as medium through which data were
transferred. Multiple biosignal sensing units were attached to a subject
and wireless personal area network was formed. Data of the sensing
units were shared among them. We used wideband pulse
communication that was simple, low-power consuming and high data
rated. Each unit functioned as independent communication device or
node. A method of channel search and communication among the
modes was developed. A protocol of carrier sense multiple
access/collision detect was implemented in order to avoid data
collision or interferences. Biosignal sensing units should be located at
different locations due to the nature of biosignal origin. Our research
provided a flexibility of collecting data without using electrical wires.
More non-constrained measurement was accomplished which was
more suitable for u-Health monitoring.