Abstract: The heat pipe is a thermal device which allows efficient transport of thermal energy. The experimental work of this research was split into two phases; phase 1 is the development of the facilities, material and test rig preparation. Phase 2 is the actual experiments and measurements of the thermal control mockup inside the modified vacuum chamber (MVC). Due to limited funds, the development on the thermal control subsystem was delayed and the experimental facilities such as suitable thermal vacuum chamber with space standard specifications were not available from the beginning of the research and had to be procured over a period of time. In all, these delays extended the project by one and a half year. Thermal control subsystem needs a special facility and equipment to be tested. The available vacuum chamber is not suitable for the thermal tests. Consequently, the modification of the chamber was a must. A vacuum chamber has been modified to be used as a Thermal Vaccum Chamber (TVC). A MVC is a vacuum chamber modified by using a stainless mirror box with perfect reflectability and the infrared lamp connected with the voltage regulator to vary the lamp intensity as it will be illustrated through the paper.
Abstract: Heat pipe is characterised as superconductor of heat because of its excellent heat removal ability. The operation of several engineering system results in generation of heat. This may cause several overheating problems and lead to failure of the systems. To overcome this problem and to achieve desired rate of heat dissipation, there is need to study the performance of heat pipe with annular fins under free convection at different inclinations. This study demonstrates the effect of different mass flow rate of hot fluid into evaporator section on the condenser side heat transfer coefficient with annular fins under natural convection at different inclinations. In this study annular fins are used for the experimental work having dimensions of length of fin, thickness of fin and spacing of fin as 10 mm, 1 mm and 6 mm, respectively. The main aim of present study is to discover at what inclination angles the maximum heat transfer coefficient shall be achieved. The heat transfer coefficient on the external surface of heat pipe condenser section is determined by experimental method and then predicted by empirical correlations. The results obtained from experimental and Churchill and Chu relation for laminar are in fair agreement with not more than 22% deviation. It is elucidated the maximum heat transfer coefficient of 31.2 W/(m2-K) at 25˚ tilt angle and minimal condenser heat transfer coefficient of 26.4 W/(m2-K) is seen at 45˚ tilt angle and 200 ml/min mass flow rate. Inclination angle also affects the thermal performance of heat pipe. Beyond 25o inclination, heat transport rate starts to decrease.
Abstract: Heat pipe is considered to be applied as a passive system to remove residual heat that generated from reactor core when incident occur or from spent fuel storage pool. The objectives are to characterized the heat transfer phenomena, performance of heat pipe, and as a model for large heat pipe will be applied as passive cooling system on nuclear spent fuel pool storage. In this experimental wickless heat pipe or two-phase closed thermosyphon (TPCT) is used. Variation of heat flux are 611.24 Watt/m2 - 3291.29 Watt/m2. Variation of filling ratio are 45 - 70%. Variation of initial pressure are -62 to -74 cm Hg. Demineralized water is used as working fluid in the TPCT. The results showed that increasing of heat load leads to an increase of evaporation of the working fluid. The optimum filling ratio obtained for 60% of TPCT evaporator volume, and initial pressure variation gave different TPCT wall temperature characteristic. TPCT showed best performance with 60% filling ratio and can be consider to be applied as passive residual heat removal system or passive cooling system on spent fuel storage pool.
Abstract: The aim of this research is to design a LHP with low thermal resistance and low condenser temperature. A Self-designed cascade LHP was tested by using biomaterial, sintered copper powder, and aluminum screen mesh as the wick. Using pure water as the working fluid for the first level of the LHP and 96% alcohol as the working fluid for the second level of LHP, the experiments were run with 10W, 20W, and 30W heat input. Experimental result shows that the usage of biomaterial as wick could reduce more temperature at evaporator than by using sintered copper powder and screen mesh up to 22.63% and 37.41% respectively. The lowest thermal resistance occurred during the usage of biomaterial as wick of heat pipe, which is 2.06 oC/W. The usage of cascade system could be applied to LHP to reduce the temperature at condenser and reduced thermal resistance up to 17.6%.
Abstract: Technological innovations in electronic world demand novel, compact, simple in design, less costly and effective heat transfer devices. Closed Loop Pulsating Heat Pipe (CLPHP) is a passive phase change heat transfer device and has potential to transfer heat quickly and efficiently from source to sink. Thermal performance of a CLPHP is governed by various parameters such as number of U-turns, orientations, input heat, working fluids and filling ratio. The present paper is an attempt to predict the thermal performance of a CLPHP using Artificial Neural Network (ANN). Filling ratio and heat input are considered as input parameters while thermal resistance is set as target parameter. Types of neural networks considered in the present paper are radial basis, generalized regression, linear layer, cascade forward back propagation, feed forward back propagation; feed forward distributed time delay, layer recurrent and Elman back propagation. Linear, logistic sigmoid, tangent sigmoid and Radial Basis Gaussian Function are used as transfer functions. Prediction accuracy is measured based on the experimental data reported by the researchers in open literature as a function of Mean Absolute Relative Deviation (MARD). The prediction of a generalized regression ANN model with spread constant of 4.8 is found in agreement with the experimental data for MARD in the range of ±1.81%.
Abstract: Closed Loop Pulsating Heat Pipe (CLPHP) is a passive two-phase heat transfer device having potential to achieve high heat transfer rates over conventional cooling techniques. It is found in electronics cooling due to its outstanding characteristics such as excellent heat transfer performance, simple, reliable, cost effective, compact structure and no external mechanical power requirement etc. Comprehensive understanding of the thermo-hydrodynamic mechanism of CLPHP is still lacking due to its contradictory results available in the literature. The present paper discusses the experimental study on 9 turn CLPHP. Inner and outer diameters of the copper tube are 2 mm and 4 mm respectively. The lengths of the evaporator, adiabatic and condenser sections are 40 mm, 100 mm and 50 mm respectively. Water is used as working fluid. The Filling Ratio (FR) is kept as 50% throughout the investigations. The gravitational effect is studied by placing the evaporator heater at different orientations such as horizontal (90 degree), vertical top (180 degree) and bottom (0 degree) as well as inclined top (135 degree) and bottom (45 degree). Heat input is supplied in the range of 10-50 Watt. Heat transfer mechanism is natural convection in the condenser section. Vacuum pump is used to evacuate the system up to 10-5 bar. The results demonstrate the influence of input heat flux and gravity on the thermal performance of the CLPHP.
Abstract: This study presents experimental and optimization of
nanoparticle mass concentration and heat input based on the total
thermal resistance (Rth) of loop heat pipe (LHP), employed for PCCPU
cooling. In this study, silica nanoparticles (SiO2) in water with
particle mass concentration ranged from 0% (pure water) to 1% is
considered as the working fluid within the LHP. The experimental
design and optimization is accomplished by the design of
experimental tool, Response Surface Methodology (RSM). The
results show that the nanoparticle mass concentration and the heat
input have significant effect on the Rth of LHP. For a given heat
input, the Rth is found to decrease with the increase of the
nanoparticle mass concentration up to 0.5% and increased thereafter.
It is also found that the Rth is decreased when the heat input is
increased from 20W to 60W. The results are optimized with the
objective of minimizing the Rth, using Design-Expert software, and
the optimized nanoparticle mass concentration and heat input are
0.48% and 59.97W, respectively, the minimum thermal resistance
being 2.66 (ºC/W).
Abstract: This paper presents the result of an experimental
investigation regarding the use of Fe2O3 nanoparticles added to
kerosene as a working fluid, under magnetic field for Copper
Oscillating Heat pipe with inclination angle of 0°(horizontal), 15°,
30°,45°, 60°,75° and 90° (vertical). The following were examined;
measure the temperature distribution and heat transfer rate on
Oscillating Heat Pipe (OHP), with magnetic field under different
angles. Results showed that the addition of Fe2O3 nanoparticles under
magnetic field improved thermal performance of OHP especially in
75°.
Abstract: The development of electric vehicle batteries have
resulted in very high energy density lithium-ion batteries. However,
this progress is accompanied by the risk of thermal runaway, which
can result in serious accidents. Heat pipes are heat exchangers that
are suitable to be applied in electric vehicle battery thermal
management for their lightweight, compact size and do not require
external power supply. This paper aims to examine experimentally a
Flat Plate Loop Heat Pipe (FPLHP) performance as a heat exchanger
in thermal management system of lithium-ion battery for electric
vehicle application. The heat generation of the battery was simulated
using a cartridge heater. Stainless steel screen mesh was used as the
capillary wick. Distilled water, alcohol and acetone were used as
working fluids with a filling ratio of 60%. It was found that acetone
gives the best performance that produces thermal resistance of 0.22
W/°C with 50°C evaporator temperature at heat flux load of 1.61
W/cm2.
Abstract: This paper deals with the theoretical and numerical
investigation of magneto hydrodynamic boundary layer flow of a
nanofluid past a wedge shaped wick in heat pipe used for the cooling
of electronic components and different type of machines. To
incorporate the effect of nanoparticle diameter, concentration of
nanoparticles in the pure fluid, nanothermal layer formed around the
nanoparticle and Brownian motion of nanoparticles etc., appropriate
models are used for the effective thermal and physical properties of
nanofluids. To model the rotation of nanoparticles inside the base
fluid, microfluidics theory is used. In this investigation ethylene
glycol (EG) based nanofluids, are taken into account. The non-linear
equations governing the flow and heat transfer are solved by using a
very effective particle swarm optimization technique along with
Runge-Kutta method. The values of heat transfer coefficient are
found for different parameters involved in the formulation viz.
nanoparticle concentration, nanoparticle size, magnetic field and
wedge angle etc. It is found that, the wedge angle, presence of
magnetic field, nanoparticle size and nanoparticle concentration etc.
have prominent effects on fluid flow and heat transfer characteristics
for the considered configuration.
Abstract: Theoretical optimization of a copper-water negative
inclination heat pipe with internal composite wick structure had been
performed, regarding a new introduced parameter: the ratio between
the coarse mesh wraps and the fine mesh wraps of the composite
wick. Since in many cases, the design of a heat pipe matches specific
thermal requirements and physical limitations, this work
demonstrates the optimization of a 1m length, 8mm internal diameter
heat pipe without an adiabatic section, at a negative inclination angle
of -10º. The optimization is based on a new introduced parameter, LR:
the ratio between the coarse mesh wraps and the fine mesh wraps.
Abstract: The objectives of this paper are to investigate effects of dimensionless numbers on thermal performance of the vertical closed-loop pulsating heat pipe (VCLPHP) and to establish a correlation to predict the thermal performance of the VCLPHP. The CLPHPs were made of long copper capillary tubes with inner diameters of 1.50, 1.78, and 2.16mm and bent into 26 turns. Then, both ends were connected together to form a loop. The evaporator, adiabatic, and condenser sections length were equal to 50 and 150 mm. R123, R141b, acetone, ethanol, and water were chosen as variable working fluids with constant filling ratio of 50% by total volume. Inlet temperature of heating medium and adiabatic section temperature was constantly controlled at 80 and 50oC, respectively. Thermal performance was represented in a term of Kutateladze number (Ku). It can be concluded that when Prandtl number of liquid working fluid (Prl), and Karman number (Ka) increases, thermal performance increases. On contrary, when Bond number (Bo), Jacob number (Ja), and Aspect ratio (Le/Di) increases, thermal performance decreases. Moreover, the correlation to predict more precise thermal performance has been successfully established by analyzing on all dimensionless numbers that have effect on the thermal performance of the VCLPHP.
Abstract: A high thermal dissipation performance polyethylene terephthalate heat pipe has been fabricated and tested in this research. Polyethylene terephthalate (PET) is used as the container material instead of copper. Copper mesh and methanol are sealed in the middle of two PET films as the wick structure and working fluid. Although the thermal conductivity of PET (0.15-0.24 W/m·K) is much smaller than copper (401 W/m·K), the experiment results reveal that the PET heat pipe can reach a minimum thermal resistance of 0.146 (oC/W) and maximum effective thermal conductivity of 18,310 (W/m·K) with 36.9 vol% at 26 W input power. However, when the input power is larger than 30 W, the laminated PET will debond due to the high vapor pressure of methanol.
Abstract: In space during functioning, a satellite will be heated
up due to the behavior of its components such as power electronics.
In order to prevent problems in the satellite, this heat has to be
released in space thanks to the cooling system. This system consists
of a loop heat pipe (LHP), in which a fluid streams through an
evaporator and a condenser. In the evaporator, the fluid captures the
heat from the satellite and evaporates. Then it flows to the condenser
where it releases the heat and it condenses. In this project, the two
mains parts of a cooling system are studied: the evaporator and the
condenser. The study of the diphasic loop was done starting from
digital simulations carried out under Matlab and Femlab.
Abstract: The LHP is a two-phase device with extremely high
effective thermal conductivity that utilizes the thermodynamic
pressure difference to circulate a cooling fluid. A thermodynamics
analytical model is developed to explore different parameters effects
on a Loop Heat Pipe (LHP).. The effects of pipe length, pipe
diameter, condenser temperature, and heat load are reported. As pipe
length increases and/or pipe diameter decreases, a higher temperature
is expected in the evaporator.
Abstract: A theoretical study is conducted to design and explore
the effect of different parameters such as heat loads, the tube size of
piping system, wick thickness, porosity and hole size on the
performance and capability of a Loop Heat Pipe(LHP). This paper
presents a steady state model that describes the different phenomena
inside a LHP. Loop Heat Pipes(LHPs) are two-phase heat transfer
devices with capillary pumping of a working fluid. By their original
design comparing with heat pipes and special properties of the
capillary structure, they-re capable of transferring heat efficiency for
distances up to several meters at any orientation in the gravity field,
or to several meters in a horizontal position. This theoretical model is
described by different relations to satisfy important limits such as
capillary and nucleate boiling. An algorithm is developed to predict
the size of the LHP satisfying the limitations mentioned above for a
wide range of applied loads. Finally, to assess and evaluate the
algorithm and all the relations considered, we have used to design a
new kind of LHP to recover the heat from the exhaust of an actual
Gas Turbine. By finding the results, it showed that we can use the
LHP as a very high efficient device to recover the heat even in high
amount of loads(exhaust of a gas turbine). The sizes of all parts of the
LHP were obtained using the developed algorithm.
Abstract: Heat pipes are two-phase heat transfer devices with
high effective thermal conductivity. Due to the high heat transport
capacity, heat exchanger with heat pipes has become much smaller
than traditional heat exchangers in handling high heat fluxes. With
the working fluid in a heat pipe, heat can be absorbed on the
evaporator region and transported to the condenser region where the
vapour condenses releasing the heat to the cooling media. Heat pipe
technology has found increasing applications in enhancing the
thermal performance of heat exchangers in microelectranics, energy
saving in HVAC systems for operating rooms,surgery centers, hotels,
cleanrooms etc, temperature regulation systems for the human body
and other industrial sectors. Development activity in heat pipe and
thermosyphon technology in asia in recent years is surveyed. Some
new results obtained in Australia and other countries are also
included.
Abstract: An experimental study is realized in order to verify the
Mini Heat Pipe (MHP) concept for cooling high power dissipation
electronic components and determines the potential advantages of
constructing mini channels as an integrated part of a flat heat pipe. A
Flat Mini Heat Pipe (FMHP) prototype including a capillary structure
composed of parallel rectangular microchannels is manufactured and
a filling apparatus is developed in order to charge the FMHP. The
heat transfer improvement obtained by comparing the heat pipe
thermal resistance to the heat conduction thermal resistance of a
copper plate having the same dimensions as the tested FMHP is
demonstrated for different heat input flux rates. Moreover, the heat
transfer in the evaporator and condenser sections are analyzed, and
heat transfer laws are proposed. In the theoretical part of this work, a
detailed mathematical model of a FMHP with axial microchannels is
developed in which the fluid flow is considered along with the heat
and mass transfer processes during evaporation and condensation.
The model is based on the equations for the mass, momentum and
energy conservation, which are written for the evaporator, adiabatic,
and condenser zones. The model, which permits to simulate several
shapes of microchannels, can predict the maximum heat transfer
capacity of FMHP, the optimal fluid mass, and the flow and thermal
parameters along the FMHP. The comparison between experimental
and model results shows the good ability of the numerical model to
predict the axial temperature distribution along the FMHP.
Abstract: This study presents the improvement of thermal
performance of heat pipe using copper nanofluid with aqueous
solution of n-Butanol. The nanofluids kept in the suspension of
conventional fluids have the potential of superior heat transfer
capability than the conventional fluids due to their improved thermal
conductivity. In this work, the copper nanofluid which has a 40 nm
size with a concentration of 100 mg/lit is kept in the suspension of
the de-ionized (DI) water and an aqueous solution of n-Butanol and
these fluids are used as a working medium in the heat pipe. The study
discusses about the effect of heat pipe inclination, type of working
fluid and heat input on the thermal efficiency and thermal resistance.
The experimental results are evaluated in terms of its performance
metrics and are compared with that of DI water.
Abstract: Various solar energy technologies exist and they have
different application techniques in the generation of electrical power.
The widespread use of photovoltaic (PV) modules in such
technologies has been limited by relatively high costs and low
efficiencies. The efficiency of PV panels decreases as the operating
temperatures increase. This is due to the affect of solar intensity and
ambient temperature. In this work, Computational Fluid Dynamics
(CFD) was used to model the heat transfer from a standard PV panel
and thus determine the rate of dissipation of heat. To accurately
model the specific climatic conditions of the United Arab Emirates
(UAE), a case study of a new build green building in Dubai was
used. A finned heat pipe arrangement is proposed and analyzed to
determine the improved heat dissipation and thus improved
performance efficiency of the PV panel. A prototype of the
arrangement is built for experimental testing to validate the CFD
modeling and proof of concept.