Abstract: Route bus system is one of fundamental transportation device for aged people and students, and has an important role in every province. However, passengers decrease year by year, therefore the authors have developed the system called "Bus-Net" as a web application to sustain the public transport. But there are two problems in Bus-Net. One is the user interface that does not consider the variety of the device, and the other is the path planning system that dose not correspond to the on-demand bus. Then, Bus-Net was improved to be able to utilize the variety of the device, and a new function corresponding to the on-demand bus was developed.
Abstract: The statistical process control (SPC) is one of the most powerful tools developed to assist ineffective control of quality, involves collecting, organizing and interpreting data during production. This article aims to show how the use of CEP industries can control and continuously improve product quality through monitoring of production that can detect deviations of parameters representing the process by reducing the amount of off-specification products and thus the costs of production. This study aimed to conduct a technological forecasting in order to characterize the research being done related to the CEP. The survey was conducted in the databases Spacenet, WIPO and the National Institute of Industrial Property (INPI). Among the largest are the United States depositors and deposits via PCT, the classification section that was presented in greater abundance to F.
Abstract: Prior to the use of detectors, characteristics
comparison study was performed and baseline established. In patient
specific QA, the portal dosimetry mean values of area gamma,
average gamma and maximum gamma were 1.02, 0.31 and 1.31 with
standard deviation of 0.33, 0.03 and 0.14 for IMRT and the
corresponding values were 1.58, 0.48 and 1.73 with standard
deviation of 0.31, 0.06 and 0.66 for VMAT. With ImatriXX 2-D
array system, on an average 99.35% of the pixels passed the criteria
of 3%-3 mm gamma with standard deviation of 0.24 for dynamic
IMRT. For VMAT, the average value was 98.16% with a standard
deviation of 0.86. The results showed that both the systems can be
used in patient specific QA measurements for IMRT and VMAT.
The values obtained with the portal dosimetry system were found to
be relatively more consistent compared to those obtained with
ImatriXX 2-D array system.
Abstract: This paper examines the problem of designing robust H controllers for for HIV/AIDS infection system with dual drug dosages described by a Takagi-Sugeno (S) fuzzy model. Based on a linear matrix inequality (LMI) approach, we develop an H controller which guarantees the L2-gain of the mapping from the exogenous input noise to the regulated output to be less than some prescribed value for the system. A sufficient condition of the controller for this system is given in term of Linear Matrix Inequalities (LMIs). The effectiveness of the proposed controller design methodology is finally demonstrated through simulation results. It has been shown that the anti-HIV vaccines are critically important in reducing the infected cells.
Abstract: A closed-loop controlled wireless power transmission circuit block for implantable biomedical applications is described in this paper. The circuit consists of one front-end rectifier, power management sub-block including bandgap reference and low drop-out regulators (LDOs) as well as transmission power detection / feedback circuits. Simulation result shows that the front-end rectifier achieves 80% power efficiency with 750-mV single-end peak-to-peak input voltage and 1.28-V output voltage under load current of 4 mA. The power management block can supply 1.8mA average load current under 1V consuming only 12μW power, which is equivalent to 99.3% power efficiency. The wireless power transmission block described in this paper achieves a maximum power efficiency of 80%. The wireless power transmission circuit block is designed and implemented using UMC 65-nm CMOS/RF process. It occupies 1 mm × 1.2 mm silicon area.
Abstract: This paper aims at overviewing the topics of a research project (CARDIOSENSOR) on the field of health sciences (biomaterials and biomedical engineering). The project has focused on the development of a nanosensor for the assessment of the risk of cardiovascular diseases by the monitoring of C-reactive protein (CRP), which has been currently considered as the best validated inflammatory biomarker associated to cardiovascular diseases. The project involves tasks such as: 1) the development of sensor devices based on field effect transistors (FET): assembly, optimization and validation; 2) application of sensors to the detection of CRP in standard solutions and comparison with enzyme-linked immunosorbent assay (ELISA); and 3) application of sensors to real samples such as blood and saliva and evaluation of their ability to predict the risk of cardiovascular disease.
Abstract: Residual dye contents in textile dyeing wastewater have complex aromatic structures that are resistant to degrade in biological wastewater treatment. The objectives of this study were to determine the effectiveness of nanoscale zerovalent iron (NZVI) to decolorize Reactive Black 5 (RB5) and Reactive Red 198 (RR198) in synthesized wastewater and to investigate the effects of the iron particle size, iron dosage and solution pHs on the destruction of RB5 and RR198. Synthesized NZVI was confirmed by transmission electron microscopy (TEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). The removal kinetic rates (kobs) of RB5 (0.0109 min-1) and RR198 (0.0111 min-1) by 0.5% NZVI were many times higher than those of microscale zerovalent iron (ZVI) (0.0007 min-1 and 0.0008 min-1, respectively). The iron dosage increment exponentially increased the removal efficiencies of both RB5 and RR198. Additionally, lowering pH from 9 to 5 increased the decolorization kinetic rates of both RB5 and RR198 by NZVI. The destruction of azo bond (N=N) in the chromophore of both reactive dyes led to decolorization of dye solutions.
Abstract: The paper deals with the kinematics and automated
calculation of intermittent mechanisms with radial cams. Currently,
electronic cams are increasingly applied in the drives of working link
mechanisms. Despite a huge advantage of electronic cams in their reprogrammability
or instantaneous change of displacement diagrams,
conventional cam mechanisms have an irreplaceable role in
production and handling machines. With high frequency of working
cycle periods, the dynamic load of the proper servomotor rotor
increases and efficiency of electronic cams strongly decreases.
Though conventional intermittent mechanisms with radial cams are
representatives of fixed automation, they have distinct advantages in
their high speed (high dynamics), positional accuracy and relatively
easy manufacture. We try to remove the disadvantage of firm
displacement diagram by reducing costs for simple design and
automated calculation that leads reliably to high-quality and
inexpensive manufacture.
Abstract: Bleeding in the digestive duct is an important diagnostic parameter for patients. Blood in the endoscopic image can be determined by investigating the color tone of blood due to the degree of oxygenation, under- or over- illumination, food debris and secretions, etc. However, we found that how to pre-process raw images obtained from the capsule detectors was very important. We applied various image process methods suitable for the capsule endoscopic image in order to remove noises and unbalanced sensitivities for the image pixels. The results showed that much improvement was achieved by additional pre-processing techniques on the algorithm of determining bleeding areas.
Abstract: Collateralized Debt Obligations are not as widely used
nowadays as they were before 2007 Subprime crisis. Nonetheless
there remains an enthralling challenge to optimize cash flows
associated with synthetic CDOs. A Gaussian-based model is used
here in which default correlation and unconditional probabilities of
default are highlighted. Then numerous simulations are performed
based on this model for different scenarios in order to evaluate the
associated cash flows given a specific number of defaults at different
periods of time. Cash flows are not solely calculated on a single
bought or sold tranche but rather on a combination of bought and
sold tranches. With some assumptions, the simplex algorithm gives
a way to find the maximum cash flow according to correlation of
defaults and maturities. The used Gaussian model is not realistic in
crisis situations. Besides present system does not handle buying or
selling a portion of a tranche but only the whole tranche. However the
work provides the investor with relevant elements on how to know
what and when to buy and sell.
Abstract: Purpose: Planning and dosimetry of different VMAT algorithms (SmartArc, Ergo++, Autobeam) is compared with IMRT for Head and Neck Cancer patients. Modelling was performed to rule out the causes of discrepancies between planned and delivered dose. Methods: Five HNC patients previously treated with IMRT were re-planned with SmartArc (SA), Ergo++ and Autobeam. Plans were compared with each other and against IMRT and evaluated using DVHs for PTVs and OARs, delivery time, monitor units (MU) and dosimetric accuracy. Modelling of control point (CP) spacing, Leaf-end Separation and MLC/Aperture shape was performed to rule out causes of discrepancies between planned and delivered doses. Additionally estimated arc delivery times, overall plan generation times and effect of CP spacing and number of arcs on plan generation times were recorded. Results: Single arc SmartArc plans (SA4d) were generally better than IMRT and double arc plans (SA2Arcs) in terms of homogeneity and target coverage. Double arc plans seemed to have a positive role in achieving improved Conformity Index (CI) and better sparing of some Organs at Risk (OARs) compared to Step and Shoot IMRT (ss-IMRT) and SA4d. Overall Ergo++ plans achieved best CI for both PTVs. Dosimetric validation of all VMAT plans without modelling was found to be lower than ss-IMRT. Total MUs required for delivery were on average 19%, 30%, 10.6% and 6.5% lower than ss-IMRT for SA4d, SA2d (Single arc with 20 Gantry Spacing), SA2Arcs and Autobeam plans respectively. Autobeam was most efficient in terms of actual treatment delivery times whereas Ergo++ plans took longest to deliver. Conclusion: Overall SA single arc plans on average achieved best target coverage and homogeneity for both PTVs. SA2Arc plans showed improved CI and some OARs sparing. Very good dosimetric results were achieved with modelling. Ergo++ plans achieved best CI. Autobeam resulted in fastest treatment delivery times.
Abstract: White scar oyster (Crassostrea belcheri) is often eaten
raw and being the leading vehicle for foodborne disease, especially
Salmonella Weltevreden which exposed the prominent and most
resistant to radiation. Gamma irradiation at a low dose of 1 kGy was
enough to eliminate S. Weltevreden contaminated in oyster meat at a
level up to 5 log CFU/g while it still retain the raw characteristics and
equivalent sensory quality as the non-irradiated one. Process
development of ready-to-eat chilled oyster meat was conducted by
shucking the meat, individually packed in plastic bags, subjected to 1
kGy gamma radiation at chilled condition and then stored in 4oC
refrigerated temperature. Microbiological determination showed the
absence of S. Weltevreden (5 log CFU/g initial inoculated) along the
whole storage time of 30 days. Sensory evaluation indicated the
decreasing in sensory scores along storage time which determining
the product shelf life to be 18 days compared to 15 days of nonirradiated
one. The most advantage of developed process was to
provide the safe raw oyster to consumers and in addition sensory
quality retained and 3-day extension shelf life also exist.
Abstract: Coagulation of water involves the use of coagulating
agents to bring the suspended matter in the raw water together for
settling and the filtration stage. Present study is aimed to examine the
effects of aluminum sulfate as coagulant in conjunction with Moringa
Oleifera Coagulant Protein as coagulant aid on turbidity, hardness,
and bacteria in turbid water. A conventional jar test apparatus was
employed for the tests. The best removal was observed at a pH of 7
to 7.5 for all turbidities. Turbidity removal efficiency was resulted
between % 80 to % 99 by Moringa Oleifera Coagulant Protein as
coagulant aid. Dosage of coagulant and coagulant aid decreased with
increasing turbidity. In addition, Moringa Oleifera Coagulant Protein
significantly has reduced the required dosage of primary coagulant.
Residual Al+3 in treated water were less than 0.2 mg/l and meets the
environmental protection agency guidelines. The results showed that
turbidity reduction of % 85.9- % 98 paralleled by a primary
Escherichia coli reduction of 1-3 log units (99.2 – 99.97%) was
obtained within the first 1 to 2 h of treatment. In conclusions,
Moringa Oleifera Coagulant Protein as coagulant aid can be used for
drinking water treatment without the risk of organic or nutrient
release. We demonstrated that optimal design method is an efficient
approach for optimization of coagulation-flocculation process and
appropriate for raw water treatment.
Abstract: Semantic Web services will enable the semiautomatic
and automatic annotation, advertisement, discovery,
selection, composition, and execution of inter-organization business
logic, making the Internet become a common global platform where
organizations and individuals communicate with each other to carry
out various commercial activities and to provide value-added
services. There is a growing consensus that Web services alone will
not be sufficient to develop valuable solutions due the degree of
heterogeneity, autonomy, and distribution of the Web. This paper
deals with two of the hottest R&D and technology areas currently
associated with the Web – Web services and the Semantic Web. It
presents the synergies that can be created between Web Services and
Semantic Web technologies to provide a new generation of eservices.
Abstract: The aim of this study is to compare the effect of the ultrasonic pre treatment on the removal of heavy metals (Iron, Zinc and Copper) from Acid Mine Drainage (AMD) by Denver Cell flotation. Synthetic AMD and individual metal solutions are used in the initial experiments to optimise the process conditions for real AMD. Three different process methods, ultrasound treatment followed by Denver flotation cell, Denver flotation cell alone and ultrasonic treatments run simultaneously with the Denver flotation cell were tested for every sample. Precipitation of the metal solutions by using sodium hydroxide (NaOH) and application of the optimum frother dosage followed by flotation significantly reduced the metal content of the AMD.
Abstract: The use of the oncologic index ISTER allows for a more effective planning of the radiotherapic facilities in the hospitals. Any change in the radiotherapy treatment, due to unexpected stops, may be adapted by recalculating the doses to the new treatment duration while keeping the optimal prognosis. The results obtained in a simulation model on millions of patients allow the definition of optimal success probability algorithms.
Abstract: Multi-agent system approach has proven to be an effective and appropriate abstraction level to construct whole models of a diversity of biological problems, integrating aspects which can be found both in "micro" and "macro" approaches when modeling this type of phenomena. Taking into account these considerations, this paper presents the important computational characteristics to be gathered into a novel bioinformatics framework built upon a multiagent architecture. The version of the tool presented herein allows studying and exploring complex problems belonging principally to structural biology, such as protein folding. The bioinformatics framework is used as a virtual laboratory to explore a minimalist model of protein folding as a test case. In order to show the laboratory concept of the platform as well as its flexibility and adaptability, we studied the folding of two particular sequences, one of 45-mer and another of 64-mer, both described by an HP model (only hydrophobic and polar residues) and coarse grained 2D-square lattice. According to the discussion section of this piece of work, these two sequences were chosen as breaking points towards the platform, in order to determine the tools to be created or improved in such a way to overcome the needs of a particular computation and analysis of a given tough sequence. The backwards philosophy herein is that the continuous studying of sequences provides itself important points to be added into the platform, to any time improve its efficiency, as is demonstrated herein.
Abstract: The AL-MAJIRI school system is a variant of private
Arabic and Islamic schools which cater for the religious and moral development of Muslims. In the past, the system produced clerics,
scholars, judges, religious reformers, eminent teachers and great men who are worthy of emulation, particularly in northern Nigeria.
Gradually, the system lost its glory but continued to discharge its
educational responsibilities to a certain extent. This paper takes a
look at the activities of the AL-MAJIRI schools. The introduction
provides background information about Nigeria where the schools
operate. This is followed by an overview of the Nigerian educational system, the nature and the features of the AL-MAJIRI school system,
its weaknesses and the current challenges facing the schools. The paper concludes with emphasis on the urgent need for a comprehensive reform of the curriculum content of the schools. The step by step procedure required for the reform is discussed.
Abstract: The overall penumbra is usually defined as the
distance, p20–80, separating the 20% and 80% of the dose on the beam axis at the depth of interest. This overall penumbra accounts
also for the fact that some photons emitted by the distal parts of the source are only partially attenuated by the collimator. Medulloblastoma is the most common type of childhood brain tumor
and often spreads to the spine. Current guidelines call for surgery to remove as much of the tumor as possible, followed by radiation of the brain and spinal cord, and finally treatment with chemotherapy.
The purpose of this paper was to present results on an Uniformity of dose distribution in radiation fields surrounding the spine using film
dosimetry and comparison with 3D treatment planning software.
Abstract: Snake bite cases in Malaysia most often involve the
species Naja-naja and Calloselasma rhodostoma. In keeping with the
need for a rapid snake venom detection kit in a clinical setting, plate
and dot-ELISA test for the venoms of Naja-naja sumatrana,
Calloselasma rhodostoma and the cobra venom fraction V antigen
was developed. Polyclonal antibodies were raised and further used to
prepare the reagents for the dot-ELISA test kit which was tested in
mice, rabbit and virtual human models. The newly developed dot-
ELISA kit was able to detect a minimum venom concentration of
244ng/ml with cross reactivity of one antibody type. The dot-ELISA
system was sensitive and specific for all three snake venom types in
all tested animal models. The lowest minimum venom concentration
detectable was in the rabbit model, 244ng/ml of the cobra venom
fraction V antigen. The highest minimum venom concentration was
in mice, 1953ng/ml against a multitude of venoms. The developed
dot-ELISA system for the detection of three snake venom types was
successful with a sensitivity of 95.8% and specificity of 97.9%.