Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: This paper presents an analytical approach for
evaluating distribution system reliability indices in the presence of
distributed generation. Modeling distributed generation and
evaluation of distribution system reliability indices using the
frequency duration technique. Using model implements and case
studies are discussed. Results showed that location of DG and its
effect in distribution reliability indices. In this respect, impact of DG
on distribution system is investigated using the IEEE Roy Billinton
test system (RBTS2) included feeder 1. Therefore, it will help to the
distribution system planners in the DG resource placement.
Abstract: Carefully scheduling the operations of pumps can be
resulted to significant energy savings. Schedules can be defined
either implicit, in terms of other elements of the network such as tank
levels, or explicit by specifying the time during which each pump is
on/off. In this study, two new explicit representations based on timecontrolled
triggers were analyzed, where the maximum number of
pump switches was established beforehand, and the schedule may
contain fewer switches than the maximum. The optimal operation of
pumping stations was determined using a Jumping Particle Swarm
Optimization (JPSO) algorithm to achieve the minimum energy cost.
The model integrates JPSO optimizer and EPANET hydraulic
network solver. The optimal pump operation schedule of VanZyl
water distribution system was determined using the proposed model
and compared with those from Genetic and Ant Colony algorithms.
The results indicate that the proposed model utilizing the JPSO
algorithm is a versatile management model for the operation of realworld
water distribution system.
Abstract: There are a number of Distributed Generations (DGs)
installed in microgrid, which may have diverse path and direction of
power flow or fault current. The overcurrent protection scheme for the
traditional radial type distribution system will no longer meet the
needs of microgrid protection. Integrating the Intelligent Electronic
Device (IED) and a Supervisory Control and Data Acquisition
(SCADA) with IEC 61850 communication protocol, the paper
proposes a Microgrid Protection Management System (MPMS) to
protect power system from the fault. In the proposed method, the
MPMS performs logic programming of each IED to coordinate their
tripping sequence. The GOOSE message defined in IEC 61850 is used
as the transmission information medium among IEDs. Moreover, to
cope with the difference in fault current of microgrid between
grid-connected mode and islanded mode, the proposed MPMS applies
the group setting feature of IED to protect system and robust
adaptability. Once the microgrid topology varies, the MPMS will
recalculate the fault current and update the group setting of IED.
Provided there is a fault, IEDs will isolate the fault at once. Finally, the
Matlab/Simulink and Elipse Power Studio software are used to
simulate and demonstrate the feasibility of the proposed method.
Abstract: Efficient use of energy, the increase in demand of
energy and also with the reduction of natural energy sources, has
improved its importance in recent years. Most of the losses in the
system from electricity produced until the point of consumption is
mostly composed by the energy distribution system. In this study,
analysis of the resulting loss in power distribution transformer and
distribution power cable is realized which are most of the losses in
the distribution system. Transformer losses in the real distribution
system are analyzed by CYME Power Engineering Software
program. These losses are disclosed for different voltage levels and
different loading conditions.
Abstract: The recent interest in alternative and renewable
energy systems results in increased installed capacity ratio of such
systems in total energy production of the world. Specifically, Wind
Energy Conversion Systems (WECS) draw significant attention
among possible alternative energy options, recently. On the contrary
of the positive points of penetrating WECS in all over the world in
terms of environment protection, energy independence of the
countries, etc., there are significant problems to be solved for the grid
connection of large scale WECS. The reactive power regulation,
voltage variation suppression, etc. can be presented as major issues to
be considered in this regard. Thus, this paper evaluates the
application of a Static VAr Compensator (SVC) unit for the reactive
power regulation and operation continuity of WECS during a fault
condition. The system is modeled employing the IEEE 13 node test
system. Thus, it is possible to evaluate the system performance with
an overall grid simulation model close to real grid systems. The
overall simulation model is developed in
MATLAB/Simulink/SimPowerSystems® environments and the
obtained results effectively match the target of the provided study.
Abstract: To tackle the air pollution issues, Plug-in Hybrid
Electric Vehicles (PHEVs) are proposed as an appropriate solution.
Charging a large amount of PHEV batteries, if not controlled, would
have negative impacts on the distribution system. The control process
of charging of these vehicles can be centralized in parking lots that
may provide a chance for better coordination than the individual
charging in houses. In this paper, an optimization-based approach is
proposed to determine the optimum PHEV parking capacities in
candidate nodes of the distribution system. In so doing, a profile for
charging and discharging of PHEVs is developed in order to flatten
the network load profile. Then, this profile is used in solving an
optimization problem to minimize the distribution system losses. The
outputs of the proposed method are the proper place for PHEV
parking lots and optimum capacity for each parking. The application
of the proposed method on the IEEE-34 node test feeder verifies the
effectiveness of the method.
Abstract: In this paper, influence of harmonics on medium
voltage distribution system of Bogazici Electricity Distribution Inc.
(BEDAS) which takes place at Istanbul/Turkey is investigated. A ring
network consisting of residential loads is taken into account for this
study. Real system parameters and measurement results are used for
simulations. Also, probable working conditions of the system are
analyzed for 50%, 75%, and 100% loading of transformers with
similar harmonic contents. Results of the study are exhibited the
influence of nonlinear loads on %THDV, P.F. and technical losses of
the medium voltage distribution system.
Abstract: The paper develops a Non-Linear Model Predictive
Control (NMPC) of water quality in Drinking Water Distribution
Systems (DWDS) based on the advanced non-linear quality dynamics
model including disinfections by-products (DBPs). A special attention
is paid to the analysis of an impact of the flow trajectories prescribed
by an upper control level of the recently developed two-time scale
architecture of an integrated quality and quantity control in DWDS.
The new quality controller is to operate within this architecture in the
fast time scale as the lower level quality controller. The controller
performance is validated by a comprehensive simulation study based
on an example case study DWDS.
Abstract: The Markov decision process (MDP) based
methodology is implemented in order to establish the optimal
schedule which minimizes the cost. Formulation of MDP problem
is presented using the information about the current state of pipe,
improvement cost, failure cost and pipe deterioration model. The
objective function and detailed algorithm of dynamic programming
(DP) are modified due to the difficulty of implementing the
conventional DP approaches. The optimal schedule derived from
suggested model is compared to several policies via Monte
Carlo simulation. Validity of the solution and improvement in
computational time are proved.
Abstract: This paper investigates the joint effect of the
interconnected (n,k)-star network topology and Multi-Agent
automated control on restoration and reconfiguration of power
systems. With the increasing trend in development in Multi-Agent
control technologies applied to power system reconfiguration
in presence of faulty components or nodes. Fault tolerance is
becoming an important challenge in the design processes of the
distributed power system topology. Since the reconfiguration of a
power system is performed by agent communication, the (n,k)-star
interconnected network topology is studied and modeled in this
paper to optimize the process of power reconfiguration. In this paper,
we discuss the recently proposed (n,k)-star topology and examine its
properties and advantages as compared to the traditional multi-bus
power topologies. We design and simulate the topology model for
distributed power system test cases. A related lemma based on the
fault tolerance and conditional diagnosability properties is presented
and proved both theoretically and practically. The conclusion is
reached that (n,k)-star topology model has measurable advantages
compared to standard bus power systems while exhibiting fault
tolerance properties in power restoration, as well as showing
efficiency when applied to power system route discovery.
Abstract: This paper proposes a backward/forward sweep
method to analyze the power flow in radial distribution systems. The
distribution system has radial structure and high R/X ratios. So the
newton-raphson and fast decoupled methods are failed with
distribution system. The proposed method presents a load flow study
using backward/forward sweep method, which is one of the most
effective methods for the load-flow analysis of the radial distribution
system. By using this method, power losses for each bus branch and
voltage magnitudes for each bus node are determined. This method
has been tested on IEEE 33-bus radial distribution system and
effective results are obtained using MATLAB.
Abstract: Distributed Generation (DG) can help in reducing the
cost of electricity to the costumer, relieve network congestion and
provide environmentally friendly energy close to load centers. Its
capacity is also scalable and it provides voltage support at distribution
level. Hence, DG placement and penetration level is an important
problem for both the utility and DG owner. DG allocation and capacity
determination is a nonlinear optimization problem. The objective
function of this problem is the minimization of the total loss of the
distribution system. Also high levels of penetration of DG are a new
challenge for traditional electric power systems. This paper presents a
new methodology for the optimal placement of DG and penetration
level of DG in distribution system based on General Algebraic
Modeling System (GAMS) and Genetic Algorithm (GA).
Abstract: Voltage sags are the most common power quality
disturbance in the distribution system. It occurs due to the fault in the
electrical network or by the starting of a large induction motor and
this can be solved by using the custom power devices such as
Dynamic Voltage Restorer (DVR). In this paper DVR is proposed to
compensate voltage sags on critical loads dynamically. The DVR
consists of VSC, injection transformers, passive filters and energy
storage (lead acid battery). By injecting an appropriate voltage, the
DVR restores a voltage waveform and ensures constant load voltage.
The simulation and experimental results of a DVR using MATLAB
software shows clearly the performance of the DVR in mitigating
voltage sags.
Abstract: Generally, distributed generation units refer to small-scale electric power generators that produce electricity at a site close to the customer or an electric distribution system (in parallel mode). From the customers’ point of view, a potentially lower cost, higher service reliability, high power quality, increased energy efficiency, and energy independence can be the key points of a proper DG unit. Moreover, the use of renewable types of distributed generations such as wind, photovoltaic, geothermal or hydroelectric power can also provide significant environmental benefits. Therefore, it is of crucial importance to study their impacts on the distribution networks. A marked increase in Distributed Generation (DG), associated with medium voltage distribution networks, may be expected. Nowadays, distribution networks are planned for unidirectional power flows that are peculiar to passive systems, and voltage control is carried out exclusively by varying the tap position of the HV/MV transformer. This paper will compare different DG control methods and possible network reconfiguration aimed at assessing their effect on voltage profiles.
Abstract: Hanging to the trapezoidal sheet by decking hanger is a very widespread solution used in civil engineering to lead the distribution of energy, sanitary, air distribution system etc. under the roof or floor structure. The trapezoidal decking hanger is usually a part of the whole installation system for specific distribution medium. The leading companies offer installation systems for each specific distribution e.g. pipe rings, sprinkler systems, installation channels etc. Every specific part is connected to the base connector which is decking hanger. The own connection has three main components: decking hanger, threaded bar with nuts and web of trapezoidal sheet. The aim of this contribution is determinate the failure mechanism of each component in connection. Load bearing capacity of most components in connection could be calculated by formulas in European codes. This contribution is focused on problematic of bearing resistance of threaded bar in web of trapezoidal sheet. This issue is studied by experimental research and numerical modelling. This contribution presented the initial results of experiment which is compared with numerical model of specimen.
Abstract: This paper presents a fault identification, classification and fault location estimation method based on Discrete Wavelet Transform and Adaptive Network Fuzzy Inference System (ANFIS) for medium voltage cable in the distribution system.
Different faults and locations are simulated by ATP/EMTP, and then certain selected features of the wavelet transformed signals are used as an input for a training process on the ANFIS. Then an accurate fault classifier and locator algorithm was designed, trained and tested using current samples only. The results obtained from ANFIS output were compared with the real output. From the results, it was found that the percentage error between ANFIS output and real output is less than three percent. Hence, it can be concluded that the proposed technique is able to offer high accuracy in both of the fault classification and fault location.
Abstract: Distributed generation units (DGs) are grid-connected or stand-alone electric generation units located within the electric distribution system at or near the end user. It is generally accepted that centralized electric power plants will remain the major source of the electric power supply for the near future. DGs, however, can complement central power by providing incremental capacity to the utility grid or to an end user. This paper presents an efficient power dispatching model for hybrid wind-Solar power generation system, to satisfy some essential requirements, such as dispersed electric power demand, electric power quality and reducing generation cost and so on. In this paper, presented some elements of the main parts in the hybrid system; and then made fundamental dispatching strategies according to different situations; then pointed out four improving measures to improve genetic algorithm, such as: modify the producing way of selection probability, improve the way of crossover, protect excellent chromosomes, and change mutation range and so on. Finally, propose a technique for solving the unit's commitment for dispatching problem based on an improved genetic algorithm.
Abstract: This paper presents the experimental results of high-density polyethylene cable spacers for 22 kV distribution systems under salt water dip wheel test based on IEC 62217. The strength of anti-tracking and anti-erosion of cable spacer surface was studied in this study. During the test, dry band arc and corona discharge were observed on cable spacer surface. After 30,000 cycles of salt water dip wheel test, obviously surface erosion and tracking were observed especially on the ground end. Chemical analysis results by fourier transforms infrared spectroscopy showed chemical changed from oxidation and carbonization reaction on tested cable spacer. Increasing of C=O and C=C bonds confirmed occurrence of these reactions.
Abstract: Pressure loss in ductworks is an important factor to be considered in design of engineering systems such as power-plants, refineries, HVAC systems to reduce energy costs. Ductwork can be composed by straight ducts and different types of fittings (elbows, transitions, converging and diverging tees and wyes). Duct fittings are significant sources of pressure loss in fluid distribution systems. Fitting losses can be even more significant than equipment components such as coils, filters, and dampers. At the present work, a conventional 90o round elbow under turbulent incompressible airflow is studied. Mass, momentum, and k-e turbulence model equations are solved employing the finite volume method. The SIMPLE algorithm is used for the pressure-velocity coupling. In order to validate the numerical tool, the elbow pressure loss coefficient is determined using the same conditions to compare with ASHRAE database. Furthermore, the effect of Reynolds number variation on the elbow pressure loss coefficient is investigated. These results can be useful to perform better preliminary design of air distribution ductworks in air conditioning systems.