Abstract: The purpose of this paper is to present the fuzzy contraction
properties of the Hutchinson-Barnsley operator on the fuzzy
hyperspace with respect to the Hausdorff fuzzy metrics. Also we
discuss about the relationships between the Hausdorff fuzzy metrics
on the fuzzy hyperspaces. Our theorems generalize and extend some
recent results related with Hutchinson-Barnsley operator in the metric
spaces.
Abstract: The clinical usefulness of heart rate variability is
limited to the range of Holter monitoring software available. These
software algorithms require a normal sinus rhythm to accurately
acquire heart rate variability (HRV) measures in the frequency
domain. Premature ventricular contractions (PVC) or more
commonly referred to as ectopic beats, frequent in heart failure,
hinder this analysis and introduce ambiguity. This investigation
demonstrates an algorithm to automatically detect ectopic beats by
analyzing discrete wavelet transform coefficients. Two techniques
for filtering and replacing the ectopic beats from the RR signal are
compared. One technique applies wavelet hard thresholding
techniques and another applies linear interpolation to replace ectopic
cycles. The results demonstrate through simulation, and signals
acquired from a 24hr ambulatory recorder, that these techniques can
accurately detect PVC-s and remove the noise and leakage effects
produced by ectopic cycles retaining smooth spectra with the
minimum of error.
Abstract: Cardiovascular disease mostly in the form of atherosclerosis is responsible for 30% of all world deaths amounting to 17 million people per year. Atherosclerosis is due to the formation of plaque. The fatty plaque may be at risk of rupture, leading typically to stroke and heart attack. The plaque is usually associated with a high degree of lumen reduction, called a stenosis. The initiation and progression of the disease is strongly linked to the hemodynamic environment near the vessel wall. The aim of this study is to validate the flow of blood mimic through an arterial stenosis model with computational fluid dynamics (CFD) package. In experiment, an axisymmetric model constructed consists of contraction and expansion region that follow a mathematical form of cosine function. A 30% diameter reduction was used in this study. Particle image velocimetry (PIV) was used to characterize the flow. The fluid consists of rigid spherical particles suspended in waterglycerol- NaCl mixture. The particles with 20 μm diameter were selected to follow the flow of fluid. The flow at Re=155, 270 and 390 were investigated. The experimental result is compared with FLUENT simulated flow that account for viscous laminar flow model. The results suggest that laminar flow model was sufficient to predict flow velocity at the inlet but the velocity at stenosis throat at Re =390 was overestimated. Hence, a transition to turbulent regime might have been developed at throat region as the flow rate increases.
Abstract: A biophysically based multilayer continuum model of the facial soft tissue composite has been developed for simulating wrinkle formation. The deformed state of the soft tissue block was determined by solving large deformation mechanics equations using the Galerkin finite element method. The proposed soft tissue model is composed of four layers with distinct mechanical properties. These include stratum corneum, epidermal-dermal layer (living epidermis and dermis), subcutaneous tissue and the underlying muscle. All the layers were treated as non-linear, isotropic Mooney Rivlin materials. Contraction of muscle fibres was approximated using a steady-state relationship between the fibre extension ratio, intracellular calcium concentration and active stress in the fibre direction. Several variations of the model parameters (stiffness and thickness of epidermal-dermal layer, thickness of subcutaneous tissue layer) have been considered.
Abstract: The electrokinetic flow resistance (electroviscous
effect) is predicted for steady state, pressure-driven liquid flow at
low Reynolds number in a microfluidic contraction of rectangular
cross-section. Calculations of the three dimensional flow are
performed in parallel using a finite volume numerical method. The
channel walls are assumed to carry a uniform charge density and the
liquid is taken to be a symmetric 1:1 electrolyte. Predictions are
presented for a single set of flow and electrokinetic parameters. It is
shown that the magnitude of the streaming potential gradient and the
charge density of counter-ions in the liquid is greater than that in
corresponding two-dimensional slit-like contraction geometry. The
apparent viscosity is found to be very close to the value for a
rectangular channel of uniform cross-section at the chosen Reynolds
number (Re = 0.1). It is speculated that the apparent viscosity for the
contraction geometry will increase as the Reynolds number is
reduced.
Abstract: This study examined the effects of eight weeks of
whole-body vibration training (WBVT) on vertical and decuple jump
performance in handball athletes. Sixteen collegiate Level I handball
athletes volunteered for this study. They were divided equally as
control group and experimental group (EG). During the period of the
study, all athletes underwent the same handball specific training, but
the EG received additional WBVT (amplitude: 2 mm, frequency: 20 -
40 Hz) three time per week for eight consecutive weeks. The vertical
jump performance was evaluated according to the maximum height of
squat jump (SJ) and countermovement jump (CMJ). Single factor
ANCOVA was used to examine the differences in each parameter
between the groups after training with the pretest values as a covariate.
The statistic significance was set at p < .05. After 8 weeks WBVT, the
EG had significantly improved the maximal height of SJ (40.92 ± 2.96
cm vs. 48.40 ± 4.70 cm, F = 5.14, p < .05) and the maximal height
CMJ (47.25 ± 7.48 cm vs. 52.20 ± 6.25 cm, F = 5.31, p < .05). 8 weeks
of additional WBVT could improve the vertical and decuple jump
performance in handball athletes. Enhanced motor unit
synchronization and firing rates, facilitated muscular contraction
stretch-shortening cycle, and improved lower extremity
neuromuscular coordination could account for these enhancements.
Abstract: Silk sericin (SS) is a glue-like protein from silkworm
cocoon. With its outstanding moisturization and activation collagen
synthesis properties, silk protein is applied for wound healing. Since
wound dressing in film preparation can facilitate patients-
convenience and reduce risk of wound contraction, SS and polyvinyl
alcohol (PVA) films were prepared with various concentrations of
SS. Their physical properties such as surface density, light
transmission, protein dissolution and tensile modulus were
investigated. The results presented that 3% SS with 2% PVA is the
best ingredient for SS film forming.
Abstract: High Pressure Raman scattering measurements of KDP:Mn were performed at room temperatures. The X-ray powder diffraction patterns taken at room temperature by Rietveld refinement showed that doped samples of KDP-Mn have the same tetragonal structure of a pure KDP crystal, but with a contraction of the crystalline cell. The behavior of the Raman spectra, in particular the emergence of a new modes at 330 cm-1, indicates that KDP:Mn undergoes a structural phase transition with onset at around 4 GP. First principle density-functional theory (DFT) calculations indicate that tetrahedral rotation with pressure is predominantly around the c crystalline direction. Theoretical results indicates that pressure induced tetrahedral rotations leads to change tetrahedral neighborhood, activating librations/bending modes observed for high pressure phase of KDP:Mn with stronger Raman activity.
Abstract: It is known that the heart interacts with and adapts to
its venous and arterial loading conditions. Various experimental
studies and modeling approaches have been developed to investigate
the underlying mechanisms. This paper presents a model of the left
ventricle derived based on nonlinear stress-length myocardial
characteristics integrated over truncated ellipsoidal geometry, and
second-order dynamic mechanism for the excitation-contraction
coupling system. The results of the model presented here describe the
effects of the viscoelastic damping element of the electromechanical
coupling system on the hemodynamic response. Different heart rates
are considered to study the pacing effects on the performance of the
left-ventricle against constant preload and afterload conditions under
various damping conditions. The results indicate that the pacing
process of the left ventricle has to take into account, among other
things, the viscoelastic damping conditions of the myofilament
excitation-contraction process.
Abstract: In this paper, a numerical study has been made to
analyze the transient 2-D flows of a viscous incompressible fluid
through channels with forward or backward constriction. Problems
addressed include flow through sudden contraction and sudden
expansion channel geometries with rounded and increasingly sharp
reentrant corner. In both the cases, numerical results are presented for
the separation and reattachment points, streamlines, vorticity and
flow patterns. A fourth order accurate compact scheme has been
employed to efficiently capture steady state solutions of the
governing equations. It appears from our study that sharpness of the
throat in the channel is one of the important parameters to control the
strength and size of the separation zone without modifying the
general flow patterns. The comparison between the two cases shows
that the upstream geometry plays a significant role on vortex growth
dynamics.
Abstract: Electromyography (EMG) is the study of muscles function through analysis of electrical activity produced from muscles. This electrical activity which is displayed in the form of signal is the result of neuromuscular activation associated with muscle contraction. The most common techniques of EMG signal recording are by using surface and needle/wire electrode where the latter is usually used for interest in deep muscle. This paper will focus on surface electromyogram (SEMG) signal. During SEMG recording, several problems had to been countered such as noise, motion artifact and signal instability. Thus, various signal processing techniques had been implemented to produce a reliable signal for analysis. SEMG signal finds broad application particularly in biomedical field. It had been analyzed and studied for various interests such as neuromuscular disease, enhancement of muscular function and human-computer interface.
Abstract: Using a force balanced translational-radial dynamics,
phase space of the moving single bubble sonoluminescence (m-
SBSL) in 85% wt sulfuric acid has been numerically calculated. This
phase space is compared with that of single bubble sonoluminescence
(SBSL) in pure water which has been calculated by using the mere
radial dynamics. It is shown that in 85% wt sulfuric acid, in a general
agreement with experiment, the bubble-s positional instability
threshold lays under the shape instability threshold. At the onset of
spatial instability of moving sonoluminescing (SL) bubble in 85%
wt sulfuric acid, temporal effects of the hydrodynamic force on the
bubble translational-radial dynamics have been investigated. The
appearance of non-zero history force on the moving SL bubble is
because of proper condition which was produced by high viscosity of
acid. Around the moving bubble collapse due to the rapid contraction
of the bubble wall, the inertial based added mass force overcomes the
viscous based history force and induces acceleration on the bubble
translational motion.
Abstract: The numerical simulation of the slip effect via
vicoelastic fluid for 4:1 contraction problem is investigated with
regard to kinematic behaviors of streamlines and stress tensor by
models of the Navier-Stokes and Oldroyd-B equations. Twodimensional
spatial reference system of incompressible creeping flow
with and without slip velocity is determined and the finite element
method of a semi-implicit Taylor-Galerkin pressure-correction is
applied to compute the problem of this Cartesian coordinate system
including the schemes of velocity gradient recovery method and the
streamline-Upwind / Petrov-Galerkin procedure. The slip effect at
channel wall is added to calculate after each time step in order to
intend the alteration of flow path. The result of stress values and the
vortices are reduced by the optimum slip coefficient of 0.1 with near
the outcome of analytical solution.
Abstract: Cardiovascular diseases, principally atherosclerosis, are responsible for 30% of world deaths. Atherosclerosis is due to the formation of plaque. The fatty plaque may be at risk of rupture, leading typically to stroke and heart attack. The plaque is usually associated with a high degree of lumen reduction, called a stenosis.It is increasingly recognized that the initiation and progression of disease and the occurrence of clinical events is a complex interplay between the local biomechanical environment and the local vascular biology. The aim of this study is to investigate the flow behavior through a stenosed artery. A physical experiment was performed using an artery model and blood analogue fluid. An axisymmetric model constructed consists of contraction and expansion region that follow a mathematical form of cosine function. A 30% diameter reduction was used in this study. The flow field was measured using particle image velocimetry (PIV). Spherical particles with 20μm diameter were seeded in a water-glycerol-NaCl mixture. Steady flow Reynolds numbers are 250. The area of interest is the region after the stenosis where the flow separation occurs. The velocity field was measured and the velocity gradient was investigated. There was high particle concentration in the recirculation zone. High velocity gradient formed immediately after the stenosis throat created a lift force that enhanced particle migration to the flow separation area.
Abstract: The turbulent mixing of coolant streams of different
temperature and density can cause severe temperature fluctuations in
piping systems in nuclear reactors. In certain periodic contraction
cycles these conditions lead to thermal fatigue. The resulting aging
effect prompts investigation in how the mixing of flows over a sharp
temperature/density interface evolves. To study the fundamental
turbulent mixing phenomena in the presence of density gradients,
isokinetic (shear-free) mixing experiments are performed in a square
channel with Reynolds numbers ranging from 2-500 to 60-000.
Sucrose is used to create the density difference. A Wire Mesh Sensor
(WMS) is used to determine the concentration map of the flow in the
cross section. The mean interface width as a function of velocity,
density difference and distance from the mixing point are analyzed
based on traditional methods chosen for the purposes of
atmospheric/oceanic stratification analyses. A definition of the
mixing layer thickness more appropriate to thermal fatigue and based
on mixedness is devised. This definition shows that the thermal
fatigue risk assessed using simple mixing layer growth can be
misleading and why an approach that separates the effects of large
scale (turbulent) and small scale (molecular) mixing is necessary.
Abstract: Prolonged immobilization leads to significant
weakness and atrophy of the skeletal muscle and can also impair the
recovery of muscle strength following injury. Therefore, it is
important to minimize the period under immobilization and accelerate
the return to normal activity. This study examined the effects of heat
treatment and rest-inserted exercise on the muscle activity of the lower
limb during knee flexion/extension. Twelve healthy subjects were
assigned to 4 groups that included: (1) heat treatment + rest-inserted
exercise; (2) heat + continuous exercise; (3) no heat + rest-inserted
exercise; and (4) no heat + continuous exercise. Heat treatment was
applied for 15 mins prior to exercise. Continuous exercise groups
performed knee flexion/extension at 0.5 Hz for 300 cycles without rest
whereas rest-inserted exercise groups performed the same exercise but
with 2 mins rest inserted every 60 cycles of continuous exercise.
Changes in the rectus femoris and hamstring muscle activities were
assessed at 0, 1, and 2 weeks of treatment by measuring the
electromyography signals of isokinetic maximum voluntary
contraction. Significant increases in both the rectus femoris and
hamstring muscles were observed after 2 weeks of treatment only
when both heat treatment and rest-inserted exercise were performed.
These results suggest that combination of various treatment techniques,
such as heat treatment and rest-inserted exercise, may expedite the
recovery of muscle strength following immobilization.
Abstract: It is known that the heart interacts with and adapts to its venous and arterial loading conditions. Various experimental studies and modeling approaches have been developed to investigate the underlying mechanisms. This paper presents a model of the left ventricle derived based on nonlinear stress-length myocardial characteristics integrated over truncated ellipsoidal geometry, and second-order dynamic mechanism for the excitation-contraction coupling system. The results of the model presented here describe the effects of the viscoelastic damping element of the electromechanical coupling system on the hemodynamic response. Different heart rates are considered to study the pacing effects on the performance of the left-ventricle against constant preload and afterload conditions under various damping conditions. The results indicate that the pacing process of the left ventricle has to take into account, among other things, the viscoelastic damping conditions of the myofilament excitation-contraction process. The effects of left ventricular dimensions on the hemdynamic response have been examined. These effects are found to be different at different viscoelastic and pacing conditions.
Abstract: Ventricular fibrillation is a very important health
problem as is the cause of most of the sudden deaths in the world.
Waves of electrical activity are sent by the SA node, propagate
through the cardiac tissue and activate the mechanisms of cell
contraction, and therefore are responsible to pump blood to the body
harmonically. A spiral wave is an abnormal auto sustainable wave
that is responsible of certain types of arrhythmias. When these waves
break up, give rise to the fibrillation regime, in which there is a
complete loss in the coordination of the contraction of the heart
muscle. Interaction of spiral waves and obstacles is also of great
importance as it is believed that the attachment of a spiral wave to an
obstacle can provide with a transition of two different arrhythmias.
An obstacle can be partially excitable or non excitable. In this talk,
we present a numerical study of the interaction of meandering spiral
waves with partially and non excitable obstacles and focus on the
problem where the obstacle plays a fundamental role in the switch
between different spiral regimes, which represent different
arrhythmic regimes. Particularly, we study the phenomenon of
destabilization of spiral waves due to the presence of obstacles, a
phenomenon not completely understood (This work will appear as a
Chapter in a Book named Cardiac Arrhytmias by INTECH under the
name "Spiral Waves, Obstacles and Cardiac Arrhythmias", ISBN
979-953-307-050-5.).
Abstract: ECG analysis method was developed using ROC
analysis of PVC detecting algorithm. ECG signal of MIT-BIH
arrhythmia database was analyzed by MATLAB. First of all, the
baseline was removed by median filter to preprocess the ECG signal.
R peaks were detected for ECG analysis method, and normal VCG
was extracted for VCG analysis method. Four PVC detecting
algorithm was analyzed by ROC curve, which parameters are
maximum amplitude of QRS complex, width of QRS complex, r-r
interval and geometric mean of VCG. To set cut-off value of
parameters, ROC curve was estimated by true-positive rate
(sensitivity) and false-positive rate. sensitivity and false negative rate
(specificity) of ROC curve calculated, and ECG was analyzed using
cut-off value which was estimated from ROC curve. As a result, PVC
detecting algorithm of VCG geometric mean have high availability,
and PVC could be detected more accurately with amplitude and width
of QRS complex.