Abstract: This paper investigates the activity of the
gastrocnemius (Gas) muscle in healthy subjects during salat (ruku-
position) and specific exercise [Unilateral Plantar Flexion Exercise
(UPFE)] using electromyography (EMG). Both lateral and medial
Gas muscles were assessed. A group of undergraduates aged between
19 to 25 years voluntarily participated in this study. The myoelectric
activity of the muscles were recorded and analyzed. The finding
indicated that there were contractions of the muscles during the salat
and exercise with almost same EMG-s level. From the result,
Wilcoxon-s Rank Sum test showed no significant difference between
ruku- and UPFE for both medial (p=0.082) and lateral (p=0.226) of
GAS muscles. Therefore, salat may be useful in strengthening
exercise and also in rehabilitation programs for lower limb activities.
Abstract: The design of methods of the 20 K large dimension cold shield used for infrared radiation demarcating in space environment simulation test were introduced in this paper. The cold shield were cooled by five G-M cryocoolers , and the dimension of the cold shield is the largest in our country.Cold shield installation and distribution and compensator for contraction on cooling were introduced detailedly. The temperature distribution and cool-down time of cold shield surface were also calculated and analysed in this paper. The design of cold shield resolves the difficulty of compensator for contraction on cooling successfully. Test results show that the actual technical performance indicators of cold shield met and exceeded the design requirements.
Abstract: Calcium is a vital second messenger used in signal transduction. Calcium controls secretion, cell movement, muscular contraction, cell differentiation, ciliary beating and so on. Two theories have been used to simplify the system of reaction-diffusion equations of calcium into a single equation. One is excess buffer approximation (EBA) which assumes that mobile buffer is present in excess and cannot be saturated. The other is rapid buffer approximation (RBA), which assumes that calcium binding to buffer is rapid compared to calcium diffusion rate. In the present work, attempt has been made to develop a model for calcium diffusion under excess buffer approximation in neuron cells. This model incorporates the effect of [Na+] influx on [Ca2+] diffusion,variable calcium and sodium sources, sodium-calcium exchange protein, Sarcolemmal Calcium ATPase pump, sodium and calcium channels. The proposed mathematical model leads to a system of partial differential equations which have been solved numerically using Forward Time Centered Space (FTCS) approach. The numerical results have been used to study the relationships among different types of parameters such as buffer concentration, association rate, calcium permeability.
Abstract: This paper illustrates the use of a combined neural
network model for classification of electrocardiogram (ECG) beats.
We present a trainable neural network ensemble approach to develop
customized electrocardiogram beat classifier in an effort to further
improve the performance of ECG processing and to offer
individualized health care.
We process a three stage technique for detection of premature
ventricular contraction (PVC) from normal beats and other heart
diseases. This method includes a denoising, a feature extraction and a
classification. At first we investigate the application of stationary
wavelet transform (SWT) for noise reduction of the
electrocardiogram (ECG) signals. Then feature extraction module
extracts 10 ECG morphological features and one timing interval
feature. Then a number of multilayer perceptrons (MLPs) neural
networks with different topologies are designed.
The performance of the different combination methods as well as
the efficiency of the whole system is presented. Among them,
Stacked Generalization as a proposed trainable combined neural
network model possesses the highest recognition rate of around 95%.
Therefore, this network proves to be a suitable candidate in ECG
signal diagnosis systems. ECG samples attributing to the different
ECG beat types were extracted from the MIT-BIH arrhythmia
database for the study.
Abstract: To compare Healing Effects of an
Ayurvedic Preparation and Silver Sulfadiazine on burn wounds in
Albino Rats.
Methods: Albino rats– 30 male / female rats weighing between
150-200 g were used in the study. They were individually housed and
maintained on normal diet and water ad libitum. Partial thickness
burn wounds were inflicted, on overnight-starved animals under
pentobarbitone (30mg/kg, i.p.) anaesthesia, by pouring hot molten
wax at 80oC into a plastic cylinder of 300 mm2 circular openings
placed on the shaven back of the animal. Apart from the drugs under
investigation no local/ systemic chemotherapeutic cover will be
provided to animals. All the animals were assessed for the percentage
of wound contraction, signs of infection, scab formation and
histopathological examination.
Results: Percentage of wound healing was significantly better in
the test ointment group compared to the standard. Signs of infection
were observed in more animals in the test ointment group compared
to the standard. Scab formation also took place earlier in the test
ointment group compared to standard. Epithelial regeneration and
healing profile was better in the test ointment compared to the
standard. Moreover the test ointment group did not show any raised
margins in the wound or blackish discoloration as was observed in
silver sulfadiazine group.
Conclusion: The burn wound healing effect of the ayurvedic
ointment under study is better in comparison to standard therapy of
silver sulfadiazine. The problem of infection encountered with the
test ointment can be overcome by changing the concentrations and
proportions of the ingredients in the test ointment which constitutes
the further plan of the study.
Abstract: The purpose of this study was to evaluate and
compare new indices based on the discrete wavelet transform
with another spectral parameters proposed in the literature as
mean average voltage, median frequency and ratios between
spectral moments applied to estimate acute exercise-induced
changes in power output, i.e., to assess peripheral muscle
fatigue during a dynamic fatiguing protocol. 15 trained
subjects performed 5 sets consisting of 10 leg press, with 2
minutes rest between sets. Surface electromyography was
recorded from vastus medialis (VM) muscle. Several surface
electromyographic parameters were compared to detect
peripheral muscle fatigue. These were: mean average voltage
(MAV), median spectral frequency (Fmed), Dimitrov spectral
index of muscle fatigue (FInsm5), as well as other five
parameters obtained from the discrete wavelet transform
(DWT) as ratios between different scales. The new wavelet
indices achieved the best results in Pearson correlation
coefficients with power output changes during acute dynamic
contractions. Their regressions were significantly different
from MAV and Fmed. On the other hand, they showed the
highest robustness in presence of additive white gaussian
noise for different signal to noise ratios (SNRs). Therefore,
peripheral impairments assessed by sEMG wavelet indices
may be a relevant factor involved in the loss of power output
after dynamic high-loading fatiguing task.