Abstract: This work describes a system that uses electromyography (EMG) signals obtained from muscle sensors and an Artificial Neural Network (ANN) for signal classification and pattern recognition that is used to control a small unmanned aerial vehicle using specific arm movements. The main objective of this endeavor is the development of an intelligent interface that allows the user to control the flight of a drone beyond direct manual control. The sensor used were the MyoWare Muscle sensor which contains two EMG electrodes used to collect signals from the posterior (extensor) and anterior (flexor) forearm, and the bicep. The collection of the raw signals from each sensor was performed using an Arduino Uno. Data processing algorithms were developed with the purpose of classifying the signals generated by the arm’s muscles when performing specific movements, namely: flexing, resting, and motion of the arm. With these arm motions roll control of the drone was achieved. MATLAB software was utilized to condition the signals and prepare them for the classification. To generate the input vector for the ANN and perform the classification, the root mean square and the standard deviation were processed for the signals from each electrode. The neuromuscular information was trained using an ANN with a single 10 neurons hidden layer to categorize the four targets. The result of the classification shows that an accuracy of 97.5% was obtained. Afterwards, classification results are used to generate the appropriate control signals from the computer to the drone through a Wi-Fi network connection. These procedures were successfully tested, where the drone responded successfully in real time to the commanded inputs.
Abstract: Individuals with non-specific chronic low back pain may present altered movement patterns during functional activities. However, muscle behavior before and after performing a functional task with different load conditions is not yet fully understood. The aim of this study is to analyze lumbar muscle activity before and after performing the functional task of picking up and placing an object on the ground (with and without load) in individuals with nonspecific chronic low back pain. 20 subjects with nonspecific chronic low back pain and 20 healthy subjects participated in this study. A surface electromyography was performed in the ilio-costal, longissimus and multifidus muscles to evaluate lumbar muscle activity before and after performing the functional task of picking up and placing an object on the ground, with and without load. The symptomatic participants had greater lumbar muscle activation compared to the asymptomatic group, more evident in performing the task without load, with statistically significant difference (p = 0,033) between groups for the right multifidus muscle. This study showed that individuals with nonspecific chronic low back pain have higher muscle activation before and after performing a functional task compared to healthy participants.
Abstract: With the advocacy of green transportation and green traveling, cycling has become increasingly popular nowadays. Physiology and bike design are key factors for the influence of cycling efficiency. Therefore, this study aimed to investigate the significance of bike-frame geometric factors on cycling efficiency and muscle activation for different body sizes of non-professional Asian male cyclists. Participants who represented various body sizes, as measured by leg and back lengths, carried out cycling tests using a tailor-assembled road bike with different ergonomic design configurations including seat-height adjustments (i.e., 96%, 100%, and 104% of trochanteric height) and bike frame sizes (i.e., small and medium frames) for an assessable distance of 1 km. A specific power meter and self-developed adaptable surface electromyography (sEMG) were used to measure average pedaling power and cadence generated and muscle activation, respectively. The results showed that changing the seat height was far more significant than the body and bike frame sizes. The sEMG data evidently provided a better understanding of muscle activation as a function of different seat heights. Therefore, the interpretation of this study is that the major bike ergonomic design factor dominating the cycling efficiency of Asian participants with different body sizes was the seat height.
Abstract: The aim of this study is to assesses the lifting capabilities of persons experiencing hypoxia. It also examines the behavior of the physiological response induced through the lifting process related to changing in the hypoxia and lifting frequency variables. For this purpose, the study performed two consecutive tests by using; (1) training and acclimatization; and (2) an actual collection of data. A total of 10 male students from King Saud University, Kingdom of Saudi Arabia, were recruited in the study. A two-way repeated measures design, with two independent variables (ambient oxygen (15%, 18% and 21%)) and lifting frequency (1 lift/min and 4 lifts/min) and four dependent variables i.e., maximum acceptable weight of lift (MAWL), Electromyography (EMG) of four muscle groups (anterior deltoid, trapezius, biceps brachii, and erector spinae), rating of perceived exertion (RPE), and rating of oxygen feeling (ROF) were used in this study. The results show that lifting frequency has significantly impacted the MAWL and muscles’ activities. The oxygen content had a significant effect on the RPE and ROE. The study has revealed that acclimatization and training sessions significantly reduce the effect of the hypoxia on the human physiological parameters during the manual materials handling tasks.
Abstract: Electromyography (EMG) is one of the most important interfaces between humans and robots for rehabilitation. Decoding this signal helps to recognize muscle activation and converts it into smooth motion for the robots. Detecting each muscle’s pattern during walking and running is vital for improving the quality of a patient’s life. In this study, EMG data from 10 muscles in 10 subjects at 4 different speeds were analyzed. EMG signals are nonlinear with high dimensionality. To deal with this challenge, we extracted some features in time-frequency domain and used manifold learning and Laplacian Eigenmaps algorithm to find the intrinsic features that represent data in low-dimensional space. We then used the Bayesian classifier to identify various patterns of EMG signals for different muscles across a range of running speeds. The best result for vastus medialis muscle corresponds to 97.87±0.69 for sensitivity and 88.37±0.79 for specificity with 97.07±0.29 accuracy using Bayesian classifier. The results of this study provide important insight into human movement and its application for robotics research.
Abstract: This study presents a framework for development of a
new generation of therapy robots that can interact with users by
monitoring their physiological and mental states. Here, we focused
on one of the controversial methods of therapy, hypnotherapy.
Hypnosis has shown to be useful in treatment of many clinical
conditions. But, even for healthy people, it can be used as an
effective technique for relaxation or enhancement of memory and
concentration. Our aim is to develop a robot that collects information
about user’s mental and physical states using electroencephalogram
(EEG) and electromyography (EMG) signals and performs costeffective
hypnosis at the comfort of user’s house. The presented
framework consists of three main steps: (1) Find the EEG-correlates
of mind state before, during, and after hypnosis and establish a
cognitive model for state changes, (2) Develop a system that can
track the changes in EEG and EMG activities in real time and
determines if the user is ready for suggestion, and (3) Implement our
system in a humanoid robot that will talk and conduct hypnosis on
users based on their mental states. This paper presents a pilot study in
regard to the first stage, detection of EEG and EMG features during
hypnosis.
Abstract: Industrial robots as part of highly automated manufacturing are recently developed to cooperative (light-weight) robots. This offers the opportunity of using them as assistance robots and to improve the participation in professional life of disabled or handicapped people such as tetraplegics. Robots under development are located within a cooperation area together with the working person at the same workplace. This cooperation area is an area where the robot and the working person can perform tasks at the same time. Thus, working people and robots are operating in the immediate proximity. Considering the physical restrictions and the limited mobility of tetraplegics, a hands-free robot control could be an appropriate approach for a cooperative assistance robot. To meet these requirements, the research project MeRoSy (human-robot synergy) develops methods for cooperative assistance robots based on the measurement of head movements of the working person. One research objective is to improve the participation in professional life of people with disabilities and, in particular, mobility impaired persons (e.g. wheelchair users or tetraplegics), whose participation in a self-determined working life is denied. This raises the research question, how a human-robot cooperation workplace can be designed for hands-free robot control. Here, the example of a library scenario is demonstrated. In this paper, an empirical study that focuses on the impact of head movement related stress is presented. 12 test subjects with tetraplegia participated in the study. Tetraplegia also known as quadriplegia is the worst type of spinal cord injury. In the experiment, three various basic head movements were examined. Data of the head posture were collected by a motion capture system; muscle activity was measured via surface electromyography and the subjective mental stress was assessed via a mental effort questionnaire. The muscle activity was measured for the sternocleidomastoid (SCM), the upper trapezius (UT) or trapezius pars descendens, and the splenius capitis (SPL) muscle. For this purpose, six non-invasive surface electromyography sensors were mounted on the head and neck area. An analysis of variance shows differentiated muscular strains depending on the type of head movement. Systematically investigating the influence of different basic head movements on the resulting strain is an important issue to relate the research results to other scenarios. At the end of this paper, a conclusion will be drawn and an outlook of future work will be presented.
Abstract: Electromyography (EMG) is one of the important indicators during exercise, as it is closely related to the level of muscle activations. This work quantifies the muscle conditions of the lower limbs in a constant workload exercise. Surface EMG signals of the vastus laterals (VL), vastus medialis (VM), rectus femoris (RF), gastrocnemius medianus (GM), gastrocnemius lateral (GL) and Soleus (SOL) were recorded from fourteen healthy males. The EMG signals were segmented in two phases: activation segment (AS) and relaxation segment (RS). Period entropy (PE), peak count (PC), zero crossing (ZC), wave length (WL), mean power frequency (MPF), median frequency (MDF) and root mean square (RMS) are calculated to provide the quantitative information of the measured EMG segments. The outcomes reveal that the PE, PC, ZC and RMS have significantly changed (p
Abstract: In this paper, the design and evaluation of a handle for laparoscopic surgery is presented. The design of the handle is based on ergonomic principles and tries to avoid awkward postures for surgeons. The handle combines the so-called power-grip and accurate-grip in order to provide strength and accuracy in the performance of surgery. The handle is tested using both objective and subjective approaches. The objective approach uses motion capture techniques to obtain the angles of forearm, arm, wrist and hand. The muscular effort is obtained with electromyography electrodes. On the other hand, a subjective survey has been carried out using questionnaires. Results confirm that the handle is preferred by the majority of the surgeons.
Abstract: This paper deals with a method of learning to solve a real problem in biomedical engineering from a technical study of muscle fatigue. Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles (viewpoint: anatomical and physiological). EMG is used as a diagnostics tool for identifying neuromuscular diseases, assessing low-back pain and muscle fatigue in general. In order to study the EMG signal for detecting fatigue in a muscle, we have taken a real problem which touches the tramway conductor the handle bar. For the study, we have used a typical autonomous platform in order to get signals at real time. In our case study, we were confronted with complex problem to do our experiments in a tram. This type of problem is recurring among students. To teach our students the method to solve this kind of problem, we built a similar system. Through this study, we realized a lot of objectives such as making the equipment for simulation, the study of detection of muscle fatigue and especially how to manage a study of biomedical looking.
Abstract: Cortisol is essential to the regulation of the immune
system and pathological yawning is a symptom of multiple sclerosis
(MS). Electromyography activity (EMG) in the jaw muscles typically
rises when the muscles are moved – extended or flexed; and yawning
has been shown to be highly correlated with cortisol levels in healthy
people as shown in the Thompson Cortisol Hypothesis. It is likely
that these elevated cortisol levels are also seen in people with MS.
The possible link between EMG in the jaw muscles and rises in saliva
cortisol levels during yawning were investigated in a randomized
controlled trial of 60 volunteers aged 18-69 years who were exposed
to conditions that were designed to elicit the yawning response.
Saliva samples were collected at the start and after yawning, or at the
end of the presentation of yawning-provoking stimuli, in the absence
of a yawn, and EMG data was additionally collected during rest and
yawning phases. Hospital Anxiety and Depression Scale, Yawning
Susceptibility Scale, General Health Questionnaire, demographic,
and health details were collected and the following exclusion criteria
were adopted: chronic fatigue, diabetes, fibromyalgia, heart
condition, high blood pressure, hormone replacement therapy,
multiple sclerosis, and stroke. Significant differences were found
between the saliva cortisol samples for the yawners, t (23) = -4.263, p
= 0.000, as compared with the non-yawners between rest and poststimuli,
which was non-significant. There were also significant
differences between yawners and non-yawners for the EMG
potentials with the yawners having higher rest and post-yawning
potentials. Significant evidence was found to support the Thompson
Cortisol Hypothesis suggesting that rises in cortisol levels are
associated with the yawning response. Further research is underway
to explore the use of cortisol as a potential diagnostic tool as an assist
to the early diagnosis of symptoms related to neurological disorders.
Bournemouth University Research & Ethics approval granted:
JC28/1/13-KA6/9/13. Professional code of conduct, confidentiality,
and safety issues have been addressed and approved in the Ethics
submission. Trials identification number: ISRCTN61942768.
http://www.controlled-trials.com/isrctn/
Abstract: Cortisol is essential to the regulation of the immune
system and yawning is a pathological symptom of multiple sclerosis
(MS). Electromyography activity (EMG) in the jaw muscles typically
rises when the muscles are moved and with yawning is highly
correlated with cortisol levels in healthy people. Saliva samples from
59 participants were collected at the start and after yawning, or at the
end of the presentation of yawning-provoking stimuli, in the absence
of a yawn, together with EMG data and questionnaire data: Hospital
Anxiety and Depression Scale, Yawning Susceptibility Scale,
General Health Questionnaire, demographic, health details. Exclusion
criteria: chronic fatigue, diabetes, fibromyalgia, heart condition, high
blood pressure, hormone replacement therapy, multiple sclerosis,
stroke. Significant differences were found between the saliva cortisol
samples for the yawners, t (23) = -4.263, p = 0.000, as compared with
the non-yawners between rest and post-stimuli, which was nonsignificant.
Significant evidence was found to support the Thompson
Cortisol Hypothesis suggesting that rises in cortisol levels are
associated with yawning. Further research is exploring the use of
cortisol as an early diagnostic tool for MS. Ethics approval granted
and professional code of conduct, confidentiality, and safety issues
are approved therein.
Abstract: This paper investigates the activity of the rectus
femoris (RF) and biceps femoris (BF) in healthy subjects during salat
(prostration) and specific exercise (squat exercise) using
electromyography (EMG). A group of undergraduates aged between
19 to 25 years voluntarily participated in this study. The myoelectric
activity of the muscles were recorded and analyzed. The finding
indicated that there were contractions of the muscles during the salat
and exercise with almost same EMG’s level. From the result,
Wilcoxon’s Rank Sum test showed significant difference between
prostration and squat exercise (p
Abstract: Robotics provides answers to amputees. The most
expensive solutions surgically connect the prosthesis to nerve endings.
There are also several types of non-invasive technologies that recover
nerve messages passing through the muscles. After analyzing these
messages, myoelectric prostheses perform the desired movement.
The main goal is to avoid all surgeries, which can be heavy and offer
cheaper alternatives. For an amputee, we use valid muscles to recover
the electrical signal involved in a muscle movement. EMG sensors
placed on the muscle allows us to measure a potential difference,
which our program transforms into control for a robotic arm with two
degrees of freedom. We have shown the feasibility of non-invasive
prostheses with two degrees of freedom. Signal analysis and an
increase in degrees of freedom is still being improved.
Abstract: Kinematic data wisely correlate vector quantities in
space to scalar parameters in time to assess the degree of symmetry
between the intact limb and the amputated limb with respect to a
normal model derived from the gait of control group participants.
Furthermore, these particular data allow a doctor to preliminarily
evaluate the usefulness of a certain rehabilitation therapy.
Kinetic curves allow the analysis of ground reaction forces (GRFs)
to assess the appropriateness of human motion.
Electromyography (EMG) allows the analysis of the fundamental
lower limb force contributions to quantify the level of gait
asymmetry. However, the use of this technological tool is expensive
and requires patient’s hospitalization. This research work suggests
overcoming the above limitations by applying artificial neural
networks.
Abstract: The development of an low cost acquisition system of S-EMG signals which are reliable, comfortable for the user and with high mobility shows to be a relevant proposition in modern biomedical engineering scenario. In the study, the sampling capacity of the Arduino microcontroller Atmel Atmega328 with an A / D converter with 10-bit resolution and its reconstructing capability of a signal of surface electromyography is analyzed. An electronic circuit to capture the signal through two differential channels was designed, signals from Biceps Brachialis of a healthy man of 21 years was acquired to test the system prototype. ARV, MDF, MNF and RMS estimators were used to compare de acquired signals with physiological values. The Arduino was configured with a sampling frequency of 1.5kHz for each channel, and the tests with the circuit designed offered a SNR of 20.57dB.
Abstract: The article deals with biomechanics of cyclist with unilateral transtibial amputation. Transtibial amputation completely removes ankle and part of muscles of a lower leg which are responsible for production of force during pedaling and causes significant geometric and power asymmetry between the limbs during cycling movement. The primary goal of this work is to assess the effects of length adjustment of the crank on the kinematics and muscle activity of cyclist. The paper presents experimental work, which aims to find a suitable ratio of the length of kinematic components to improve overall athletic performance. The study presents the results of the kinematic analysis of the cycling movement with different crank length realized by tracking camera system together with the results of muscle activity measurements captured by electromyography and measurement of forces in the cranks by strain gauges.
Abstract: This paper proposes a method of remotely controlling robots with arm gestures using surface electromyography (EMG) and accelerometer sensors attached to the operator’s wrists. The EMG and accelerometer sensors receive signals from the arm gestures of the operator and infer the corresponding movements to execute the command to control the robot. The movements of the robot include moving forward and backward and turning left and right. The accuracy is over 99% and movements can be controlled in real time.
Abstract: The research was designed to examine the relationship
between the development of muscle fatigue and the effect it has on
sport performance, specifically during maximal voluntary
contraction. This kind of this investigation using simultaneous
electrophysiological and mechanical recordings, based on advanced
mathematical processing, allows us to get parameters, and indexes in
a short time, and finally, the mapping to use for the thorough
investigation of the muscle contraction force, respectively the
phenomenon of local muscle fatigue, both for athletes and other
subjects.
Abstract: The aim of this study was to remove the two principal
noises which disturb the surface electromyography signal
(Diaphragm). These signals are the electrocardiogram ECG artefact
and the power line interference artefact. The algorithm proposed
focuses on a new Lean Mean Square (LMS) Widrow adaptive
structure. These structures require a reference signal that is correlated
with the noise contaminating the signal. The noise references are
then extracted : first with a noise reference mathematically
constructed using two different cosine functions; 50Hz (the
fundamental) function and 150Hz (the first harmonic) function for
the power line interference and second with a matching pursuit
technique combined to an LMS structure for the ECG artefact
estimation. The two removal procedures are attained without the use
of supplementary electrodes. These techniques of filtering are
validated on real records of surface diaphragm electromyography
signal. The performance of the proposed methods was compared with
already conducted research results.