Abstract: Wireless Sensor Networks (WSNs) have many advantages. Their deployment is easier and faster than wired sensor networks or other wireless networks, as they do not need fixed infrastructure. Nodes are partitioned into many small groups named clusters to aggregate data through network organization. WSN clustering guarantees performance achievement of sensor nodes. Sensor nodes energy consumption is reduced by eliminating redundant energy use and balancing energy sensor nodes use over a network. The aim of such clustering protocols is to prolong network life. Low Energy Adaptive Clustering Hierarchy (LEACH) is a popular protocol in WSN. LEACH is a clustering protocol in which the random rotations of local cluster heads are utilized in order to distribute energy load among all sensor nodes in the network. This paper proposes Connected Dominant Set (CDS) based cluster formation. CDS aggregates data in a promising approach for reducing routing overhead since messages are transmitted only within virtual backbone by means of CDS and also data aggregating lowers the ratio of responding hosts to the hosts existing in virtual backbones. CDS tries to increase networks lifetime considering such parameters as sensors lifetime, remaining and consumption energies in order to have an almost optimal data aggregation within networks. Experimental results proved CDS outperformed LEACH regarding number of cluster formations, average packet loss rate, average end to end delay, life computation, and remaining energy computation.
Abstract: There is a widespread belief in everyday discourse that science subjects (physics, chemistry and biology) are, along with math, the most difficult school subjects in the education of an individual. This assumption is usually justified by the following facts: low GPA in these subjects, the number of pupils who fail these subjects is high in comparison to other subjects, and the number of pupils interested in continuing their studies in the fields with a focus on science subjects is lower compared to non-science-oriented fields. From that perspective, the project: “Could it be different? How do children explore it?” becomes extremely interesting because it is focused on young children and on the introduction of new methods, with aim of arousing interest in scientific literacy development in 10 kindergartens by applying the methodology of an action research, with an ethnographic approach. We define scientific literacy as a process of encouraging and nurturing the research and explorative spirit in children, as well as their natural potential and abilities that represent an object of scientific research: to learn about exploration by conducting exploration. Upon project completion, an evaluation questionnaire was created for the parents of the children who had participated in the project, as well as for those whose children had not been involved in the project. The purpose of the first questionnaire was to examine the level of satisfaction with the project implementation and its outcomes among those parents whose children had been involved in the project (N=142), while the aim of the second questionnaire was to find out how much the parents of the children not involved (N=154) in this activity were interested in this topic.
Abstract: This paper presents a method to generate a finite element model of the human auditory inner ear system. The geometric model has been realized using 2D images from a virtual model of temporal bones. A point cloud has been gotten manually from those images to construct a whole mesh with hexahedral elements. The main difference with the predecessor models is the spiral shape of the cochlea with its three scales completely defined: scala tympani, scala media and scala vestibuli; which are separate by basilar membrane and Reissner membrane. To validate this model, numerical simulations have been realised with two models: an isolated inner ear and a whole model of human auditory system. Ideal conditions of displacement are applied over the oval window in the isolated Inner Ear model. The whole model is made up of the outer auditory channel, the tympani, the ossicular chain, and the inner ear. The boundary condition for the whole model is 1Pa over the auditory channel entrance. The numerical simulations by FEM have been done using a harmonic analysis with a frequency range between 100-10.000 Hz with an interval of 100Hz. The following results have been carried out: basilar membrane displacement; the scala media pressure according to the cochlea length and the transfer function of the middle ear normalized with the pressure in the tympanic membrane. The basilar membrane displacements and the pressure in the scala media make it possible to validate the response in frequency of the basilar membrane.
Abstract: Global Software Development (GSD) is becoming a common norm in software industry, despite of the fact that global distribution of the teams presents special issues for effective communication and coordination of the teams. Now trends are changing and project management for distributed teams is no longer in a limbo. GSD can be effectively established using agile and project managers can use different agile techniques/tools for solving the problems associated with distributed teams. Agile methodologies like scrum and XP have been successfully used with distributed teams. We have employed exploratory research method to analyze different recent studies related to challenges of GSD and their proposed solutions. In our study, we had deep insight in six commonly faced challenges: communication and coordination, temporal differences, cultural differences, knowledge sharing/group awareness, speed and communication tools. We have established that each of these challenges cannot be neglected for distributed teams of any kind. They are interlinked and as an aggregated whole can cause the failure of projects. In this paper we have focused on creating a scalable framework for detecting and overcoming these commonly faced challenges. In the proposed solution, our objective is to suggest agile techniques/tools relevant to a particular problem faced by the organizations related to the management of distributed teams. We focused mainly on scrum and XP techniques/tools because they are widely accepted and used in the industry. Our solution identifies the problem and suggests an appropriate technique/tool to help solve the problem based on globally shared knowledgebase. We can establish a cause and effect relationship using a fishbone diagram based on the inputs provided for issues commonly faced by organizations. Based on the identified cause, suitable tool is suggested, our framework suggests a suitable tool. Hence, a scalable, extensible, self-learning, intelligent framework proposed will help implement and assess GSD to achieve maximum out of it. Globally shared knowledgebase will help new organizations to easily adapt best practices set forth by the practicing organizations.
Abstract: Extended periods engaged in sedentary behavior increases the risk of becoming overweight and/or obese which is linked to other health problems. Adding technology to the term ‘active living’ permits its inclusion in promoting and facilitating habitual physical activity. Technology can either act as a barrier to, or facilitate this lifestyle, depending on the chosen technology. Physical Activity Monitoring Technologies (PAMTs) are a popular example of such technologies. Different contemporary PAMTs have been evaluated based on customer reviews; however, there is a lack of published experimental research into the efficacy of PAMTs. This research aims to investigate the reliability of four PAMTs: two wristbands (Fitbit Flex and Jawbone UP), a waist-clip (Fitbit One), and a mobile application (iPhone Health Application) for recording a specific distance walked on a treadmill (1.5km) at constant speed. Physical activity tracking technologies are varied in their recordings, even while performing the same activity. This research demonstrates that Jawbone UP band recorded the most accurate distance compared to Fitbit One, Fitbit Flex, and iPhone Health Application.
Abstract: The purpose of the study is to develop a finite element model based on 3D bone structural images of Micro-CT and to analyze the stress distribution for the osteoporosis mouse femora. In this study, results of finite element analysis show that the early osteoporosis of mouse model decreased a bone density in trabecular region; however, the bone density in cortical region increased.
Abstract: Adult mesenchymal stem cells (MSCs) have been investigated using preclinical approaches for tissue regeneration. Porcine MSCs (pMSCs) are capable of growing and attaching to plastic with a fibroblast-like morphology and then differentiating into bone, adipose, and cartilage tissues in vitro. This study was conducted to investigate the proliferating abilities, differentiation potentials, and multipotency of miniature pig adipose tissue-derived MSCs (mpAD-MSCs) with or without long-term cryopreservation, considering that cryostorage has the potential for use in clinical applications. After confirming the characteristics of the mpAD-MSCs, we examined the effect of long-term cryopreservation (> 2 years) on expression of cell surface markers (CD34, CD90 and CD105), proliferating abilities (cumulative population doubling level, doubling time, colony-forming unit, and MTT assay) and differentiation potentials into mesodermal cell lineages. As a result, the expression of cell surface markers is similar between thawed and fresh mpAD-MSCs. However, long-term cryopreservation significantly lowered the differentiation potentials (adipogenic, chondrogenic, and osteogenic) of mpAD-MSCs. When compared with fresh mpAD-MSCs, thawed mpAD-MSCs exhibited lower expression of mesodermal cell lineage-related genes such as peroxisome proliferator-activated receptor-g2, lipoprotein lipase, collagen Type II alpha 1, osteonectin, and osteocalcin. Interestingly, long-term cryostoraged mpAD-MSCs exhibited significantly higher cell viability than the fresh mpAD-MSCs. Long-term cryopreservation induced a 30% increase in the cell viability of mpAD-MSCs when compared with the fresh mpAD-MSCs at 5 days after thawing. However, long-term cryopreservation significantly lowered expression of stemness markers such as Oct3/4, Sox2, and Nanog. Furthermore, long-term cryopreservation negatively affected expression of senescence-associated genes such as telomerase reverse transcriptase and heat shock protein 90 of mpAD-MSCs when compared with the fresh mpAD-MSCs. The results from this study might be important for the successful application of MSCs in clinical trials after long-term cryopreservation.
Abstract: Bisphenol A (BPA) is an organic synthetic compound that has many applications in various industries and is known as persistent pollutant. The aim of this research was to evaluate the efficiency of bone ash and banana peel as adsorbents for BPA adsorption from aqueous solution by using Response Surface Methodology. The effects of some variables such as sorbent dose, detention time, solution pH, and BPA concentration on the sorption efficiency was examined. All analyses were carried out according to Standard Methods. The sample size was performed using Box-Benken design and also optimization of BPA removal was done using response surface methodology (RSM). The results showed that the BPA adsorption increases with increasing of contact time and BPA concentration. However, it decreases with higher pH. More adsorption efficiency of a banana peel is very smaller than a bone ash so that BPA removal for bone ash and banana peel is 62 and 28 percent, respectively. It is concluded that a bone ash has a good ability for the BPA adsorption.
Abstract: Background: Plantar pressure measurement is an effective method for assessing plantar loading and can be applied to evaluating movement performance of the foot. The purpose of this study is to explore the sprint athletes’ plantar loading characteristics and pain profiles in static standing. Methods: Experiments were undertaken on 80 first-division college sprint athletes and 85 healthy non-sprinters. ‘JC Mat’, the optical plantar pressure measurement was applied to examining the differences between both groups in the arch index (AI), three regional and six distinct sub-regional plantar pressure distributions (PPD), and footprint characteristics. Pain assessment and self-reported health status in sprint athletes were examined for evaluating their common pain areas. Results: Findings from the control group, the males’ AI fell into the normal range. Yet, the females’ AI was classified as the high-arch type. AI values of the sprint group were found to be significantly lower than the control group. PPD were higher at the medial metatarsal bone of both feet and the lateral heel of the right foot in the sprint group, the males in particular, whereas lower at the medial and lateral longitudinal arches of both feet. Footprint characteristics tended to support the results of the AI and PPD, and this reflected the corresponding pressure profiles. For the sprint athletes, the lateral knee joint and biceps femoris were the most common musculoskeletal pains. Conclusions: The sprint athletes’ AI were generally classified as high arches, and that their PPD were categorized between the features of runners and high-arched runners. These findings also correspond to the profiles of patellofemoral pain syndrome (PFPS)-related plantar pressure. The pain profiles appeared to correspond to the symptoms of high-arched runners and PFPS. The findings reflected upon the possible link between high arches and PFPS. The correlation between high-arched runners and PFPS development is worth further studies.
Abstract: Pure form of L-Dopa is used to enhance muscular development, fat breakdown and suppress Parkinson disease in humans. However, the L-Dopa in mucuna seed, when present with other antinutritional factors, causes nutritional disorders in monogastric animals. Information on the utilisation of pure L-Dopa in monogastric animals is scanty. Therefore, effect of L-Dopa on growth performance and carcass characteristics in broiler chickens was investigated. Two hundred and forty one-day-old chicks were allotted to six treatments, which consisted of a positive control (PC) with standard energy (3100Kcal/Kg) and negative control (NC) with high energy (3500Kcal/Kg). The rest 4 diets were NC+0.1, NC+0.2, NC+0.3 and NC+0.4% L-Dopa, respectively. All treatments had 4 replicates in a completely randomized design. Body weight gain, final weight, feed intake, dressed weight and carcass characteristics were determined. Body weight gain and final weight of birds fed PC were 1791.0 and 1830.0g, NC+0.1% L-Dopa were 1827.7 and 1866.7g and NC+0.2% L-Dopa were 1871.9 and 1910.9g respectively, and the feed intake of PC (3231.5g), were better than other treatments. The dressed weight at 1375.0g and 1357.1g of birds fed NC+0.1% and NC+0.2% L-Dopa, respectively, were similar but better than other treatments. Also, the thigh (202.5g and 194.9g) and the breast meat (413.8g and 410.8g) of birds fed NC+0.1% and NC+0.2% L-Dopa, respectively, were similar but better than birds fed other treatments. The drum stick of birds fed NC+0.1% L-Dopa (220.5g) was observed to be better than birds on other diets. Meat to bone ratio and relative organ weights were not affected across treatments. L-Dopa extract, at levels tested, had no detrimental effect on broilers, rather better bird performance and carcass characteristics were observed especially at 0.1% and 0.2% L-Dopa inclusion rates. Therefore, 0.2% inclusion is recommended in diets of broiler chickens for improved performance and carcass characteristics.
Abstract: Introduction: Whole-Body Vibration (WBV) uses
high frequency mechanical stimuli generated by a vibration plate and
transmitted through bone, muscle and connective tissues to the whole
body. Research has shown that long-term vibration-plate training
improves neuromuscular facilitation, especially in afferent neural
pathways, responsible for the conduction of vibration and
proprioceptive stimuli, muscle function, balance and proprioception.
Some researchers suggest that the vibration stimulus briefly inhibits
the conduction of afferent signals from proprioceptors and can
interfere with the maintenance of body balance. The aim of this study
was to evaluate the influence of a single set of exercises associated
with whole-body vibration on the joint position sense and body
balance. Material and methods: The study enrolled 55 people aged
19-24 years. These individuals were randomly divided into a test
group (30 persons) and a control group (25 persons). Both groups
performed the same set of exercises on a vibration plate. The
following vibration parameters: frequency of 20Hz and amplitude of
3mm, were used in the test group. The control group performed
exercises on the vibration plate while it was off. All participants were
instructed to perform six dynamic exercises lasting 30 seconds each
with a 60-second period of rest between them. The exercises involved
large muscle groups of the trunk, pelvis and lower limbs.
Measurements were carried out before and immediately after
exercise. Joint position sense (JPS) was measured in the knee joint
for the starting position at 45° in an open kinematic chain. JPS error
was measured using a digital inclinometer. Balance was assessed in a
standing position with both feet on the ground with the eyes open and
closed (each test lasting 30 sec). Balance was assessed using Matscan
with FootMat 7.0 SAM software. The surface of the ellipse of
confidence and front-back as well as right-left swing were measured
to assess balance. Statistical analysis was performed using Statistica
10.0 PL software. Results: There were no significant differences
between the groups, both before and after the exercise (p> 0.05). JPS
did not change in both the test (10.7° vs. 8.4°) and control groups
(9.0° vs. 8.4°). No significant differences were shown in any of the
test parameters during balance tests with the eyes open or closed in
both the test and control groups (p> 0.05). Conclusions: 1.
Deterioration in proprioception or balance was not observed
immediately after the vibration stimulus. This suggests that vibrationinduced
blockage of proprioceptive stimuli conduction can have only
a short-lasting effect that occurs only as long as a vibration stimulus
is present. 2. Short-term use of vibration in treatment does not impair
proprioception and seems to be safe for patients with proprioceptive
impairment. 3. These results need to be supplemented with an
assessment of proprioception during the application of vibration
stimuli. Additionally, the impact of vibration parameters used in the
exercises should be evaluated.
Abstract: Excessive fretting wear at the taper-trunnion junction
(trunnionosis) apparently contributes to the high failure rates of hip
implants. Implant wear and corrosion lead to the release of metal
particulate debris and subsequent release of metal ions at the tapertrunnion
surface. This results in a type of metal poisoning referred to
as metallosis. The consequences of metal poisoning include;
osteolysis (bone loss), osteoarthritis (pain), aseptic loosening of the
prosthesis and revision surgery. Follow up after revision surgery,
metal debris particles are commonly found in numerous locations. Background: A stable connection between the femoral ball head
(taper) and stem (trunnion) is necessary to prevent relative motions
and corrosion at the taper junction. Hence, the importance of
component assembly cannot be over-emphasized. Therefore, the aim
of this study is to determine the influence of head-stem junction
assembly by press fitting and the subsequent
disengagement/disassembly on the connection strength between the
taper ball head and stem. Methods: CoCr femoral heads were assembled with High stainless
hydrogen steel stem (trunnion) by Push-in i.e. press fit; and
disengaged by pull-out test. The strength and stability of the two
connections were evaluated by measuring the head pull-out forces
according to ISO 7206-10 standards. Findings: The head-stem junction strength linearly increases with
assembly forces.
Abstract: Obturator Foramen is a specific structure in Pelvic
bone images and recognition of it is a new concept in medical image
processing. Moreover, segmentation of bone structures such as
Obturator Foramen plays an essential role for clinical research in
orthopedics. In this paper, we present a novel method to analyze the
similarity between the substructures of the imaged region and a hand
drawn template as a preprocessing step for computation of Pelvic
bone rotation on hip radiographs. This method consists of integrated
usage of Marker-controlled Watershed segmentation and Zernike
moment feature descriptor and it is used to detect Obturator Foramen
accurately. Marker-controlled Watershed segmentation is applied to
separate Obturator Foramen from the background effectively. Then,
Zernike moment feature descriptor is used to provide matching
between binary template image and the segmented binary image for
final extraction of Obturator Foramens. Finally, Pelvic bone rotation
rate calculation for each hip radiograph is performed automatically to
select and eliminate hip radiographs for further studies which depend
on Pelvic bone angle measurements. The proposed method is tested
on randomly selected 100 hip radiographs. The experimental results
demonstrated that the proposed method is able to segment Obturator
Foramen with 96% accuracy.
Abstract: An early diagnosis of bone metastasis is very
important for making a right decision on a subsequent therapy. One
of the most important steps to be taken initially, for developing a new
radiopharmaceutical is the measurement of organ radiation exposure
dose. In this study, the dosimetric studies of a novel agent for
SPECT-imaging of the bone metastasis, 111In-(4-
{[(bis(phosphonomethyl))carbamoyl]methyl}7,10bis(carboxymethyl)
-1,4,7,10-tetraazacyclododec-1-yl) acetic acid (111In-BPAMD)
complex, have been carried out to estimate the dose in human organs
based on the data derived from mice. The radiolabeled complex was
prepared with high radiochemical purity in the optimal conditions.
Biodistribution studies of the complex was investigated in the male
Syrian mice at the selected times after injection (2, 4, 24 and 48 h).
The human absorbed dose estimation of the complex was made based
on data derived from the mice by the radiation absorbed dose
assessment resource (RADAR) method. 111In-BPAMD complex was prepared with high radiochemical
purity >95% (ITLC) and specific activities of 2.85 TBq/mmol. Total
body effective absorbed dose for 111In-BPAMD was 0.205
mSv/MBq. This value is comparable to the other 111In clinically used
complexes. The results show that the dose with respect to the critical
organs is satisfactory within the acceptable range for diagnostic
nuclear medicine procedures. Generally, 111In-BPAMD has
interesting characteristics and it can be considered as a viable agent
for SPECT-imaging of the bone metastasis in the near future.
Abstract: The measurement of organ radiation exposure dose is
one of the most important steps to be taken initially, for developing a
new radiopharmaceutical. In this study, the dosimetric studies of a
novel agent for SPECT-imaging of the bone metastasis, 111In-
1,4,7,10-tetraazacyclododecane-1,4,7,10 tetraethylene phosphonic
acid (111In-DOTMP) complex, have been carried out to estimate the
dose in human organs based on the data derived from rats. The
radiolabeled complex was prepared with high radiochemical purity in
the optimal conditions. Biodistribution studies of the complex was
investigated in the male Syrian rats at selected times after injection
(2, 4, 24 and 48 h). The human absorbed dose estimation of the
complex was made based on data derived from the rats by the
radiation absorbed dose assessment resource (RADAR) method.
111In-DOTMP complex was prepared with high radiochemical purity
of >99% (ITLC). Total body effective absorbed dose for 111In-
DOTMP was 0.061 mSv/MBq. This value is comparable to the other
111In clinically used complexes. The results show that the dose with
respect to the critical organs is satisfactory within the acceptable
range for diagnostic nuclear medicine procedures. Generally, 111In-
DOTMP has interesting characteristics and can be considered as a
viable agent for SPECT-imaging of the bone metastasis in the near
future.
Abstract: Calcium Phosphate Cement (CPC) due to its high bioactivity and optimum bioresorbability shows excellent bone regeneration capability. Despite it has limited applications as bone implant due to its macro-porous microstructure causing its poor mechanical strength. The reinforcement of apatitic CPCs with biocompatible fibre glass phase is an attractive area of research to improve upon its mechanical strength. Here, we study the setting behaviour of Si-doped and un-doped α tri calcium phosphate (α - TCP) based CPC and its reinforcement with addition of E-glass fibre. Alpha Tri calcium phosphate powders were prepared by solid state sintering of CaCO3 , CaHPO4 and Tetra Ethyl Ortho Silicate (TEOS) was used as silicon source to synthesize Si doped α-TCP powders. Both initial and final setting time of the developed cement was delayed because of Si addition. Crystalline phases of HA (JCPDS 9- 432), α-TCP (JCPDS 29-359) and β-TCP (JCPDS 9-169) were detected in the X-ray diffraction (XRD) pattern after immersion of CPC in simulated body fluid (SBF) for 0 hours to 10 days. As Si incorporation in the crystal lattice stabilized the TCP phase, Si doped CPC showed little slower rate of conversion into HA phase as compared to un-doped CPC. The SEM image of the microstructure of hardened CPC showed lower grain size of HA in un-doped CPC because of premature setting and faster hydrolysis of un-doped CPC in SBF as compared that in Si-doped CPC. Premature setting caused generation of micro and macro porosity in un-doped CPC structure which resulted in its lower mechanical strength as compared to that in Si-doped CPC. It was found that addition of 10 wt% of E-glass fibre into Si-doped α-TCP increased the average DTS of CPC from 8 MPa to 15 MPa as the fibres could resists the propagation of crack by deflecting the crack tip. Our study shows that biocompatible E-glass fibre in optimum proportion in CPC matrix can enhance the mechanical strength of CPC without affecting its biocompatibility.
Abstract: Cole-Cole parameters of 40 post-menopausal women
are compared with their DEXA bone mineral density measurements.
Impedance characteristics of four extremities are compared; left and
right extremities are statistically same, but lower extremities are
statistically different than upper ones due to their different fat
content. The correlation of Cole-Cole impedance parameters to bone
mineral density (BMD) is observed to be higher for dominant arm.
With the post-menopausal population, ANOVA tests of the dominant
arm characteristic frequency, as a predictor for DEXA classified
osteopenic and osteoporic population around lumbar spine, is
statistically very significant. When used for total lumbar spine
osteoporosis diagnosis, the area under the Receiver Operating Curve
of the characteristic frequency is 0.830, suggesting that the Cole-Cole
plot characteristic frequency could be a useful diagnostic parameter
when integrated into standard screening methods for osteoporosis.
Moreover, the characteristic frequency can be directly measured by
monitoring frequency driven angular behavior of the dominant arm
without performing any complex calculation.
Abstract: Mobile Ad hoc Network is a set of self-governing
nodes which communicate through wireless links. Dynamic topology
MANETs makes routing a challenging task. Various routing
protocols are there, but due to various fundamental characteristic
open medium, changing topology, distributed collaboration and
constrained capability, these protocols are tend to various types of
security attacks. Black hole is one among them. In this attack,
malicious node represents itself as having the shortest path to the
destination but that path not even exists. In this paper, we aim to
develop a routing protocol for detection and prevention of black hole
attack by modifying AODV routing protocol. This protocol is able to
detect and prevent the black hole attack. Simulation is done using
NS-2, which shows the improvement in network performance.
Abstract: The purpose of this study is the discrimination of 28
postmenopausal with osteoporotic femoral fractures from an agematched
control group of 28 women using texture analysis based on
fractals. Two pre-processing approaches are applied on radiographic
images; these techniques are compared to highlight the choice of the
pre-processing method. Furthermore, the values of the fractal
dimension are compared to those of the fractal signature in terms of
the classification of the two populations. In a second analysis, the
BMD measure at proximal femur was compared to the fractal
analysis, the latter, which is a non-invasive technique, allowed a
better discrimination; the results confirm that the fractal analysis of
texture on calcaneus radiographs is able to discriminate osteoporotic
patients with femoral fracture from controls. This discrimination was
efficient compared to that obtained by BMD alone. It was also
present in comparing subgroups with overlapping values of BMD.
Abstract: Typical load-bearing biological materials like bone,
mineralized tendon and shell, are biocomposites made from both
organic (collagen) and inorganic (biomineral) materials. This
amazing class of materials with intrinsic internally designed
hierarchical structures show superior mechanical properties with
regard to their weak components from which they are formed.
Extensive investigations concentrating on static loading conditions
have been done to study the biological materials failure. However,
most of the damage and failure mechanisms in load-bearing
biological materials will occur whenever their structures are exposed
to dynamic loading conditions. The main question needed to be
answered here is: What is the relation between the layout and
architecture of the load-bearing biological materials and their
dynamic behavior? In this work, a staggered model has been
developed based on the structure of natural materials at nanoscale and
Finite Element Analysis (FEA) has been used to study the dynamic
behavior of the structure of load-bearing biological materials to
answer why the staggered arrangement has been selected by nature to
make the nanocomposite structure of most of the biological materials.
The results showed that the staggered structures will efficiently
attenuate the stress wave rather than the layered structure.
Furthermore, such staggered architecture is effectively in charge of
utilizing the capacity of the biostructure to resist both normal and
shear loads. In this work, the geometrical parameters of the model
like the thickness and aspect ratio of the mineral inclusions selected
from the typical range of the experimentally observed feature sizes
and layout dimensions of the biological materials such as bone and
mineralized tendon. Furthermore, the numerical results validated with
existing theoretical solutions. Findings of the present work emphasize
on the significant effects of dynamic behavior on the natural
evolution of load-bearing biological materials and can help scientists
to design bioinspired materials in the laboratories.