Abstract: Pilot stages are one of the most common positioners and regulators in industry. In this paper, we present two novel concepts for pilot stages with low power consumption to regulate a pneumatic device. Pilot 1, first concept, is designed based on a conventional frame core electro-magnetic actuator and a leaf spring to control the air flow and pilot 2 has an axisymmetric actuator and spring made of non-oriented electrical steel. Concepts are simulated in a system modeling tool to study their dynamic behavior. Both concepts are prototyped and tested. Experimental results are comprehensively analyzed and compared. The most promising concept that consumes less than 8 mW is highlighted and presented.
Abstract: Typical load-bearing biological materials like bone,
mineralized tendon and shell, are biocomposites made from both
organic (collagen) and inorganic (biomineral) materials. This
amazing class of materials with intrinsic internally designed
hierarchical structures show superior mechanical properties with
regard to their weak components from which they are formed.
Extensive investigations concentrating on static loading conditions
have been done to study the biological materials failure. However,
most of the damage and failure mechanisms in load-bearing
biological materials will occur whenever their structures are exposed
to dynamic loading conditions. The main question needed to be
answered here is: What is the relation between the layout and
architecture of the load-bearing biological materials and their
dynamic behavior? In this work, a staggered model has been
developed based on the structure of natural materials at nanoscale and
Finite Element Analysis (FEA) has been used to study the dynamic
behavior of the structure of load-bearing biological materials to
answer why the staggered arrangement has been selected by nature to
make the nanocomposite structure of most of the biological materials.
The results showed that the staggered structures will efficiently
attenuate the stress wave rather than the layered structure.
Furthermore, such staggered architecture is effectively in charge of
utilizing the capacity of the biostructure to resist both normal and
shear loads. In this work, the geometrical parameters of the model
like the thickness and aspect ratio of the mineral inclusions selected
from the typical range of the experimentally observed feature sizes
and layout dimensions of the biological materials such as bone and
mineralized tendon. Furthermore, the numerical results validated with
existing theoretical solutions. Findings of the present work emphasize
on the significant effects of dynamic behavior on the natural
evolution of load-bearing biological materials and can help scientists
to design bioinspired materials in the laboratories.
Abstract: The compatibility of optical resonators with microfluidic systems may be relevant for chemical and biological applications. Here, a fluorescent-core microcavity (FCM) is investigated as a refractometric sensor for heavy oils. A high-index film of silicon quantum dots (QDs) was formed inside the capillary, supporting cylindrical fluorescence whispering gallery modes (WGMs). A set of standard refractive index oils was injected into a capillary, causing a shift of the WGM resonances toward longer wavelengths. A maximum sensitivity of 240 nm/RIU (refractive index unit) was found for a nominal oil index of 1.74. As well, a sensitivity of 22 nm/RIU was obtained for a lower index of 1.48, more typical of fuel hydrocarbons. Furthermore, the observed spectra and sensitivities were compared to theoretical predictions and reproduced via FDTD simulations, showing in general an excellent agreement. This work demonstrates the potential use of FCMs for oil sensing applications and the more generally for detecting liquid solutions with a high refractive index or high viscosity.