Abstract: This paper presents the results of a Finite Element
based vibration analysis of a solar powered Unmanned Aerial
Vehicle (UAV). The purpose of this paper was to quantify the free
vibration, forced vibration response due to differing point inputs in
order to predict the relative response magnitudes and frequencies at
various wing locations of vibration induced power generators
(magnet in coil) excited by gust and/or control surface pulse-decays
used to help power the flight of the electric UAV. A Fluid Structure
Interaction (FSI) study was performed in order to ascertain pertinent
design stresses and deflections as well as aerodynamic parameters of
the UAV airfoil. The 10 ft span airfoil is modeled using Mylar as the
primary material. Results show that the free mode in bending is 4.8
Hz while the first forced bending mode is on range of 16.2 to 16.7 Hz
depending on the location of excitation. The free torsional bending
mode is 28.3 Hz, and the first forced torsional mode is range of 26.4
to 27.8 Hz, depending on the location of excitation. The FSI results
predict the coefficients of aerodynamic drag and lift of 0.0052 and
0.077, respectively, which matches hand-calculations used to validate
the Finite Element based results. FSI based maximum von Mises
stresses and deflections were found to be 0.282 MPa and 3.4 mm,
respectively. Dynamic pressures on the airfoil range from 1.04 to
1.23 kPa corresponding to velocity magnitudes in range of 22 to 66
m/s.
Abstract: This paper investigates the thermal issue of permanent
magnet synchronous generator which is frequently used in direct
drive gearless small-scale wind turbine applications. Permanent
Magnet Synchronous Generator (PMSG) is designed with 2.5 kW
continuous and 6 kW peak power. Then considering generator
geometry, mechanical design of wind turbine is performed. Thermal
analysis and optimization is carried out considering all wind turbine
components to reach realistic results. This issue is extremely
important in research and development (R&D) process for wind
turbine applications.
Abstract: As per the statistical data, the Doubly-fed Induction
Generator (DFIG) based wind turbine with variable speed and
variable pitch control is the most common wind turbine in the
growing wind market. This machine is usually used on the grid
connected wind energy conversion system to satisfy grid code
requirements such as grid stability, Fault Ride Through (FRT), power
quality improvement, grid synchronization and power control etc.
Though the requirements are not fulfilled directly by the machine, the
control strategy is used in both the stator as well as rotor side along
with power electronic converters to fulfil the requirements stated
above. To satisfy the grid code requirements of wind turbine, usually
grid side converter is playing a major role. So in order to improve the
operation capacity of wind turbine under critical situation, the
intensive study of both machine side converter control and grid side
converter control is necessary In this paper DFIG is modeled using
power components as variables and the performance of the DFIG
system is analysed under grid voltage fluctuations. The voltage
fluctuations are made by lowering and raising the voltage values in
the utility grid intentionally for the purpose of simulation keeping in
view of different grid disturbances.
Abstract: This paper presents a novel algorithm for modeling
photovoltaic based distributed generators for the purpose of optimal
planning of distribution networks. The proposed algorithm utilizes
sequential Monte Carlo method in order to accurately consider the
stochastic nature of photovoltaic based distributed generators. The
proposed algorithm is implemented in MATLAB environment and
the results obtained are presented and discussed.
Abstract: This paper presents a power control for a Doubly Fed
Induction Generator (DFIG) using in Wind Energy Conversion
System (WECS) connected to the grid. The proposed control strategy
employs two nonlinear controllers, Backstipping (BSC) and slidingmode
controller (SMC) scheme to directly calculate the required
rotor control voltage so as to eliminate the instantaneous errors of
active and reactive powers. In this paper the advantages of BSC and
SMC are presented, the performance and robustness of this two
controller’s strategy are compared between them. First, we present a
model of wind turbine and DFIG machine, then a synthesis of the
controllers and their application in the DFIG power control.
Simulation results on a 1.5MW grid-connected DFIG system are
provided by MATLAB/Simulink.
Abstract: This article presents a vibration diagnostic method
designed for Permanent Magnets (PM) electrical machines–traction
motors and generators. Those machines are commonly used in traction
drives of electrical vehicles and small wind or water systems. The
described method is very innovative and unique. Specific structural
properties of machines excited by permanent magnets are used in this
method - electromotive force (EMF) generated due to vibrations. There
was analyzed number of publications, which describe vibration
diagnostic methods, and tests of electrical machines and there was no
method found to determine the technical condition of such machine
basing on their own signals. This work presents field-circuit model,
results of static tests, results of calculations and simulations.
Abstract: High Voltage Direct Current (HVDC) power
transmission is employed to move large amounts of electric power.
There are several possibilities to enhance the transient stability in a
power system. One adequate option is by using the high
controllability of the HVDC if HVDC is available in the system. This
paper presents a control technique for HVDC to enhance the transient
stability. The strategy controls the power through the HVDC to help
make the system more transient stable during disturbances. Loss of
synchronism is prevented by quickly producing sufficient
decelerating energy to counteract accelerating energy gained during.
In this study, the power flow in the HVDC link is modulated with the
addition of an auxiliary signal to the current reference of the rectifier
firing angle controller. This modulation control signal is derived from
speed deviation signal of the generator utilizing a PD controller; the
utilization of a PD controller is suitable because it has the property of
fast response. The effectiveness of the proposed controller is
demonstrated with a SMIB test system.
Abstract: Haynes 25 alloy (also known as L-605 alloy) is cobalt
based super alloy which has widely applications such as aerospace
industry, turbine and furnace parts, power generators and heat
exchangers and petroleum refining components due to its excellent
characteristics. However, the workability of this alloy is more
difficult compared to normal steels or even stainless. In present work,
an experimental investigation was performed under cryogenic
cooling to determine cutting tool wear patterns and obtain optimal
cutting parameters in turning of cobalt based superalloy Haynes 25.
In experiments, uncoated carbide tool was used and cutting speed (V)
and feed rate (f) were considered as test parameters. Tool wear
(VBmax) were measured for process performance indicators.
Analysis of variance (ANOVA) was performed to determine the
importance of machining parameters.
Abstract: This paper presents an application of Artificial Neural
Network (ANN) algorithm for improving power system voltage
stability. The training data is obtained by solving several normal and
abnormal conditions using the Linear Programming technique. The
selected objective function gives minimum deviation of the reactive
power control variables, which leads to the maximization of
minimum Eigen value of load flow Jacobian. The considered reactive
power control variables are switchable VAR compensators, OLTC
transformers and excitation of generators. The method has been
implemented on a modified IEEE 30-bus test system. The results
obtain from the test clearly show that the trained neural network is
capable of improving the voltage stability in power system with a
high level of precision and speed.
Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: Nowadays, the use of renewable energy sources has been increasingly great because of the cost increase and public demand for clean energy sources. One of the fastest growing sources is wind energy. In this paper, Wind Diesel Hybrid System (WDHS) comprising a Diesel Generator (DG), a Wind Turbine Generator (WTG), the Consumer Load, a Battery-based Energy Storage System (BESS), and a Dump Load (DL) is used. Voltage is controlled by Diesel Generator; the frequency is controlled by BESS and DL. The BESS elimination is an efficient way to reduce maintenance cost and increase the dynamic response. Simulation results with graphs for the frequency of Power System, active power, and the battery power are presented for load changes. The controlling parameters are optimized by using Imperialist Competitive Algorithm (ICA). The simulation results for the BESS/no BESS cases are compared. Results show that in no BESS case, the frequency control is more optimal than the BESS case by using ICA.
Abstract: In a practical power system, the power plants are not
located at the same distance from the center of loads and their fuel
costs are different. Also, under normal operating conditions, the
generation capacity is more than the total load demand and losses.
Thus, there are many options for scheduling generation. In an
interconnected power system, the objective is to find the real and
reactive power scheduling of each power plant in such a way as to
minimize the operating cost. This means that the generator’s real and
reactive powers are allowed to vary within certain limits so as to meet
a particular load demand with minimum fuel cost. This is called
optimal power flow problem. In this paper, Economic Load Dispatch
(ELD) of real power generation is considered. Economic Load
Dispatch (ELD) is the scheduling of generators to minimize total
operating cost of generator units subjected to equality constraint of
power balance within the minimum and maximum operating limits of
the generating units. In this paper, genetic algorithms are considered.
ELD solutions are found by solving the conventional load flow
equations while at the same time minimizing the fuel costs.
Abstract: Thousands of organisations store important and
confidential information related to them, their customers, and their
business partners in databases all across the world. The stored data
ranges from less sensitive (e.g. first name, last name, date of birth) to
more sensitive data (e.g. password, pin code, and credit card
information). Losing data, disclosing confidential information or
even changing the value of data are the severe damages that
Structured Query Language injection (SQLi) attack can cause on a
given database. It is a code injection technique where malicious SQL
statements are inserted into a given SQL database by simply using a
web browser. In this paper, we propose an effective pattern
recognition neural network model for detection and classification of
SQLi attacks. The proposed model is built from three main elements
of: a Uniform Resource Locator (URL) generator in order to generate
thousands of malicious and benign URLs, a URL classifier in order
to: 1) classify each generated URL to either a benign URL or a
malicious URL and 2) classify the malicious URLs into different
SQLi attack categories, and a NN model in order to: 1) detect either a
given URL is a malicious URL or a benign URL and 2) identify the
type of SQLi attack for each malicious URL. The model is first
trained and then evaluated by employing thousands of benign and
malicious URLs. The results of the experiments are presented in
order to demonstrate the effectiveness of the proposed approach.
Abstract: Due to the continuous increment of the load demand,
identification of weaker buses, improvement of voltage profile and
power losses in the context of the voltage stability problems has
become one of the major concerns for the larger, complex,
interconnected power systems. The objective of this paper is to
review the impact of Flexible AC Transmission System (FACTS)
controller in Wind generators connected electrical network for
maintaining voltage stability. Wind energy could be the growing
renewable energy due to several advantages. The influence of wind
generators on power quality is a significant issue; non uniform power
production causes variations in system voltage and frequency.
Therefore, wind farm requires high reactive power compensation; the
advances in high power semiconducting devices have led to the
development of FACTS. The FACTS devices such as for example
SVC inject reactive power into the system which helps in maintaining
a better voltage profile. The performance is evaluated on an IEEE 14
bus system, two wind generators are connected at low voltage buses
to meet the increased load demand and SVC devices are integrated at
the buses with wind generators to keep voltage stability. Power
flows, nodal voltage magnitudes and angles of the power network are
obtained by iterative solutions using MIPOWER.
Abstract: In this study, we proposed two techniques to track the
maximum power point (MPPT) of a photovoltaic system. The first is
an intelligent control technique, and the second is robust used for
variable structure system. In fact the characteristics I-V and P–V of
the photovoltaic generator depends on the solar irradiance and
temperature. These climate changes cause the fluctuation of
maximum power point; a maximum power point tracking technique
(MPPT) is required to maximize the output power. For this we have
adopted a control by fuzzy logic (FLC) famous for its stability and
robustness. And a Siding Mode Control (SMC) widely used for
variable structure system. The system comprises a photovoltaic panel
(PV), a DC-DC converter, which is considered as an adaptation stage
between the PV and the load. The modelling and simulation of the
system is developed using MATLAB/Simulink. SMC technique
provides a good tracking speed in fast changing irradiation and when
the irradiation changes slowly or it is constant the panel power of
FLC technique presents a much smoother signal with less
fluctuations.
Abstract: One of the crucial parameters of digital cryptographic
systems is the selection of the keys used and their distribution. The
randomness of the keys has a strong impact on the system’s security
strength being difficult to be predicted, guessed, reproduced, or
discovered by a cryptanalyst. Therefore, adequate key randomness
generation is still sought for the benefit of stronger cryptosystems.
This paper suggests an algorithm designed to generate and test
pseudo random number sequences intended for cryptographic
applications. This algorithm is based on mathematically manipulating
a publically agreed upon information between sender and receiver
over a public channel. This information is used as a seed for
performing some mathematical functions in order to generate a
sequence of pseudorandom numbers that will be used for
encryption/decryption purposes. This manipulation involves
permutations and substitutions that fulfill Shannon’s principle of
“confusion and diffusion”. ASCII code characters were utilized in the
generation process instead of using bit strings initially, which adds
more flexibility in testing different seed values. Finally, the obtained
results would indicate sound difficulty of guessing keys by attackers.
Abstract: Reflux condensation occurs in vertical channels and tubes when there is an upward core flow of vapour (or gas-vapour mixture) and a downward flow of the liquid film. The understanding of this condensation configuration is crucial in the design of reflux condensers, distillation columns, and in loss-of-coolant safety analyses in nuclear power plant steam generators. The unique feature of this flow is the upward flow of the vapour-gas mixture (or pure vapour) that retards the liquid flow via shear at the liquid-mixture interface. The present model solves the full, elliptic governing equations in both the film and the gas-vapour core flow. The computational mesh is non-orthogonal and adapts dynamically the phase interface, thus produces a sharp and accurate interface. Shear forces and heat and mass transfer at the interface are accounted for fundamentally. This modeling is a big step ahead of current capabilities by removing the limitations of previous reflux condensation models which inherently cannot account for the detailed local balances of shear, mass, and heat transfer at the interface. Discretisation has been done based on finite volume method and co-located variable storage scheme. An in-house computer code was developed to implement the numerical solution scheme. Detailed results are presented for laminar reflux condensation from steam-air mixtures flowing in vertical parallel plate channels. The results include velocity and gas mass fraction profiles, as well as axial variations of film thickness.
Abstract: This paper presents dynamic models of distributed
generators (DG) and investigates dynamic behavior of the DG units
in the micro grid system. The DG units include photovoltaic and fuel
cell sources. The voltage source inverter is adopted since the
electronic interface which can be equipped with its controller to keep
stability of the micro grid during small signal dynamics. This paper
also introduces power management strategies and implements the DG
load sharing concept to keep the micro grid operation in gridconnected
and islanding modes of operation. The results demonstrate
the operation and performance of the photovoltaic and fuel cell as
distributed generators in a micro grid. The entire control system in
the micro grid is developed by combining the benefits of the power
control and the voltage control strategies. Simulation results are all
reported, confirming the validity of the proposed control technique.
Abstract: A three-dimensional numerical model of
thermoelectric generator (TEG) modules attached to a large chimney
plate is proposed and solved numerically using a control volume based
finite difference formulation. The TEG module consists of a
thermoelectric generator, an elliptical pin-fin heat sink, and a cold
plate for water cooling. In the chimney, the temperature of flue gases is
450-650K. Although the TEG hot-side temperature and thus the
electric power output can be increased by inserting an elliptical pin-fin
heat sink into the chimney tunnel to increase the heat transfer area, the
pin fin heat sink would cause extra pumping power at the same time.
The main purpose of this study is to analyze the effects of geometrical
parameters on the electric power output and chimney pressure drop
characteristics. The effects of different operating conditions, including
various inlet velocities (Vin= 1, 3, 5 m/s), inlet temperatures (Tgas = 450,
550, 650K) and different fin height (0 to 150 mm) are discussed in
detail. The predicted numerical data for the power vs. current (P-I)
curve are in good agreement (within 11%) with the experimental data.
Abstract: In this paper, the exergy analysis of vapor absorption
refrigeration system using LiBr-H2O as working fluid is carried out
with the modified Gouy-Stodola approach rather than the classical
Gouy-Stodola equation and effect of varying input parameters is also
studied on the performance of the system. As the modified approach
uses the concept of effective temperature, the mathematical
expressions for effective temperature have been formulated and
calculated for each component of the system. Various constraints and
equations are used to develop program in EES to solve these
equations. The main aim of this analysis is to determine the
performance of the system and the components having major
irreversible loss. Results show that exergy destruction rate is
considerable in absorber and generator followed by evaporator and
condenser. There is an increase in exergy destruction in generator,
absorber and condenser and decrease in the evaporator by the
modified approach as compared to the conventional approach. The
value of exergy determined by the modified Gouy-Stodola equation
deviates maximum i.e. 26% in the generator as compared to the
exergy calculated by the classical Gouy-Stodola method.