Abstract: Two finite element (FEM) models are presented in
this paper to address the random nature of the response of glued
timber structures made of wood segments with variable elastic
moduli evaluated from 3600 indentation measurements. This total
database served to create the same number of ensembles as was the
number of segments in the tested beam. Statistics of these ensembles
were then assigned to given segments of beams and the Latin
Hypercube Sampling (LHS) method was called to perform 100
simulations resulting into the ensemble of 100 deflections subjected
to statistical evaluation. Here, a detailed geometrical arrangement of
individual segments in the laminated beam was considered in the
construction of two-dimensional FEM model subjected to in fourpoint
bending to comply with the laboratory tests. Since laboratory
measurements of local elastic moduli may in general suffer from a
significant experimental error, it appears advantageous to exploit the
full scale measurements of timber beams, i.e. deflections, to improve
their prior distributions with the help of the Bayesian statistical
method. This, however, requires an efficient computational model
when simulating the laboratory tests numerically. To this end, a
simplified model based on Mindlin’s beam theory was established.
The improved posterior distributions show that the most significant
change of the Young’s modulus distribution takes place in laminae in
the most strained zones, i.e. in the top and bottom layers within the
beam center region. Posterior distributions of moduli of elasticity
were subsequently utilized in the 2D FEM model and compared with
the original simulations.
Abstract: The thermal control in many systems is widely
accomplished applying mixed convection process due to its low cost,
reliability and easy maintenance. Typical applications include the
aircraft electronic equipment, rotating-disc heat exchangers, turbo
machinery, and nuclear reactors, etc. Natural convection in an inclined
square enclosure heated via wall heater has been studied numerically.
Finite volume method is used for solving momentum and energy
equations in the form of stream function–vorticity. The right and left
walls are kept at a constant temperature, while the other parts are
adiabatic. The range of the inclination angle covers a whole revolution.
The method is validated for a vertical cavity. A general power law
dependence of the Nusselt number with respect to the Rayleigh
number with the coefficient and exponent as functions of the
inclination angle is presented. For a fixed Rayleigh number, the
inclination angle increases or decreases is found.
Abstract: This paper proposes five level diode clamped Z source
Inverter. The existing PWM techniques used for ZSI are restricted for
two level. The two level Z Source Inverter have high harmonic
distortions which effects the performance of the grid connected PV
system. To improve the performance of the system the number of
voltage levels in the output waveform need to be increased. This
paper presents comparative analysis of a five level diode clamped Z
source Inverter with different carrier based Modified Pulse Width
Modulation techniques. The parameters considered for comparison
are output voltage, voltage gain, voltage stress across switch and total
harmonic distortion when powered by same DC supply. Analytical
results are verified using MATLAB.
Abstract: Most people today are aware that global climate
change is not just a scientific theory but also a fact with worldwide
consequences. Global climate change is due to rapid urbanization,
industrialization, high population growth and current vulnerability of
the climatic condition. Water is becoming scarce as a result of global
climate change. To mitigate the problem arising due to global climate
change and its drought effect, harvesting rainwater from green roofs,
an environmentally-friendly and versatile technology, is becoming
one of the best assessment criteria and gaining attention in Malaysia.
This paper addresses the sustainability of green roofs and examines
the quality of water harvested from green roofs in comparison to
rainwater. The factors that affect the quality of such water, taking
into account, for example, roofing materials, climatic conditions, the
frequency of rainfall frequency and the first flush. A green roof was
installed on the Humid Tropic Centre (HTC) is a place of the study
on monitoring program for urban Stormwater Management Manual
for Malaysia (MSMA), Eco-Hydrological Project in Kuala Lumpur,
and the rainwater was harvested and evaluated on the basis of four
parameters i.e., conductivity, dissolved oxygen (DO), pH and
temperature. These parameters were found to fall between Class I and
Class III of the Interim National Water Quality Standards (INWQS)
and the Water Quality Index (WQI). Some preliminary treatment
such as disinfection and filtration could likely to improve the value of
these parameters to class I. This review paper clearly indicates that
there is a need for more research to address other microbiological and
chemical quality parameters to ensure that the harvested water is
suitable for use potable water for domestic purposes. The change in
all physical, chemical and microbiological parameters with respect to
storage time will be a major focus of future studies in this field.
Abstract: The check-in area of airport terminal is one of the
busiest sections at airports at certain periods. The passengers are
subjected to queues and delays during the check-in process. These
delays and queues are due to constraints in the capacity of service
facilities. In this project, the airport terminal is decomposed into
several check-in areas. The airport check-in scheduling problem
requires both a deterministic (integer programming) and stochastic
(simulation) approach. Integer programming formulations are
provided to minimize the total number of counters in each check-in
area under the realistic constraint that counters for one and the same
flight should be adjacent and the desired number of counters
remaining in each area should be fixed during check-in operations.
By using simulation, the airport system can be modeled to study the
effects of various parameters such as number of passengers on a
flight and check-in counter opening and closing time.
Abstract: In this paper we present the efficient parallel
implementation of elastoplastic problems based on the TFETI (Total
Finite Element Tearing and Interconnecting) domain decomposition
method. This approach allow us to use parallel solution and compute
this nonlinear problem on the supercomputers and decrease the
solution time and compute problems with millions of DOFs. In
our approach we consider an associated elastoplastic model with
the von Mises plastic criterion and the combination of linear
isotropic-kinematic hardening law. This model is discretized by
the implicit Euler method in time and by the finite element
method in space. We consider the system of nonlinear equations
with a strongly semismooth and strongly monotone operator. The
semismooth Newton method is applied to solve this nonlinear
system. Corresponding linearized problems arising in the Newton
iterations are solved in parallel by the above mentioned TFETI. The
implementation of this problem is realized in our in-house MatSol
packages developed in MatLab.
Abstract: Advances in the use of health care technology have
resulted in increased adverse events (AEs) related to the use of
medical devices. The study focused on the existing reporting systems.
This study was conducted in a tertiary care public sector hospital.
Devices included Syringe infusion pumps, Cardiac monitors, Pulse
oximeters, Ventilators and Defibrillators. A total of 211 respondents
were recruited. Interviews were held with 30 key informants. Medical
records were scrutinized. Relevant statistical tests were used.
Resident doctors reported maximum frequency of AEs, followed
by nurses; and least by consultants. A significant association was
found between the cadre of health care personnel and awareness that
the patients and bystanders have a risk of sustaining AE. Awareness
regarding reporting of AEs was low, and it was generally done
verbally. Other critical findings are discussed in the light of the
barriers to reporting, reasons for non-compliance, recording system,
and so on.
Abstract: This paper discusses the design and analysis of a
hybrid PV-Fuel cell energy system destined to power a DC load. The
system is composed of a photovoltaic array, a fuel cell, an
electrolyzer and a hydrogen tank. HOMER software is used in this
study to calculate the optimum capacities of the power system
components that their combination allows an efficient use of solar
resource to cover the hourly load needs. The optimal system sizing
allows establishing the right balance between the daily electrical
energy produced by the power system and the daily electrical energy
consumed by the DC load using a 28 KW PV array, a 7.5 KW fuel
cell, a 40KW electrolyzer and a 270 Kg hydrogen tank. The variation
of powers involved into the DC bus of the hybrid PV-fuel cell system
has been computed and analyzed for each hour over one year: the
output powers of the PV array and the fuel cell, the input power of
the elctrolyzer system and the DC primary load. Equally, the annual
variation of stored hydrogen produced by the electrolyzer has been
assessed. The PV array contributes in the power system with 82%
whereas the fuel cell produces 18%. 38% of the total energy
consumption belongs to the DC primary load while the rest goes to
the electrolyzer.
Abstract: The building sector is responsible, in many
industrialized countries, for about 40% of the total energy
requirements, so it seems necessary to devote some efforts in this
area in order to achieve a significant reduction of energy
consumption and of greenhouse gases emissions.
The paper presents a study aiming at providing a design
methodology able to identify the best configuration of the system
building/plant, from a technical, economic and environmentally point
of view.
Normally, the classical approach involves a building's energy
loads analysis under steady state conditions, and subsequent selection
of measures aimed at improving the energy performance, based on
previous experience made by architects and engineers in the design
team. Instead, the proposed approach uses a sequence of two wellknown
scientifically validated calculation methods (TRNSYS and
RETScreen), that allow quite a detailed feasibility analysis.
To assess the validity of the calculation model, an existing,
historical building in Central Italy, that will be the object of
restoration and preservative redevelopment, was selected as a casestudy.
The building is made of a basement and three floors, with a
total floor area of about 3,000 square meters.
The first step has been the determination of the heating and
cooling energy loads of the building in a dynamic regime by means,
which allows simulating the real energy needs of the building in
function of its use. Traditional methodologies, based as they are on
steady-state conditions, cannot faithfully reproduce the effects of
varying climatic conditions and of inertial properties of the structure.
With this model is possible to obtain quite accurate and reliable
results that allow identifying effective combinations building-HVAC
system.
The second step has consisted of using output data obtained as
input to the calculation model, which enables to compare different
system configurations from the energy, environmental and financial
point of view, with an analysis of investment, and operation and
maintenance costs, so allowing determining the economic benefit of
possible interventions.
The classical methodology often leads to the choice of
conventional plant systems, while our calculation model provides a
financial-economic assessment for innovative energy systems and
low environmental impact.
Computational analysis can help in the design phase, particularly
in the case of complex structures with centralized plant systems, by
comparing the data returned by the calculation model for different
design options.
Abstract: Comparing other methods of waste water treatment,
constructed wetlands are one of the most fascinating practices
because being a natural process they are eco-friendly have low
construction and maintenance cost and have considerable capability
of wastewater treatment. The current research was focused mainly on
comparison of Ranunculus muricatus and Typha latifolia as wetland
plants for domestic wastewater treatment by designing and
constructing efficient pilot scale horizontal subsurface flow
mesocosms. Parameters like chemical oxygen demand, biological
oxygen demand, phosphates, sulphates, nitrites, nitrates, and
pathogenic indicator microbes were studied continuously with
successive treatments. Treatment efficiency of the system increases
with passage of time and with increase in temperature. Efficiency of
T. latifolia planted setups in open environment was fairly good for
parameters like COD and BOD5 which was showing reduction up to
82.5% for COD and 82.6% for BOD5 while DO was increased up to
125%. Efficiency of R. muricatus vegetated setup was also good but
lowers than that of T. latifolia planted showing 80.95% removal of
COD and BOD5. Ranunculus muricatus was found effective in
reducing bacterial count in wastewater. Both macrophytes were
found promising in wastewater treatment.
Abstract: Cemented carbide balls are usually implemented in
industry under the environment of high speed, high temperature,
corrosiveness and strong collisions. However, its application is limited
due to high fabrication cost, processing efficiency and quality. A novel
eccentric lapping method with two rotatable lapping plates was
proposed in this paper. A mathematical model was constructed to
analyze the influence of each design parameter on this lapping method.
To validate this new lapping method, an orthogonal experiment was
conducted with cemented carbide balls (YG6). The simulation model
was verified and the optimal lapping parameters were derived. The
results show that the surface roundness of the balls reaches to 0.65um
from 2um in 1 hour using this lapping method. So, using this novel
lapping method, it can effectively improve the machining precision
and efficiency of cemented carbide balls.
Abstract: This paper shows an experimental testing of a small
unit for combustion of solid fuels, such as charcoal and wood logs,
that can provide electricity. One of the concepts is that the unit does
not require qualified personnel for its operation. The unit itself is
composed of two main parts. The design requires a heat producing
stove and electricity producing thermoelectric generator. After the
construction the unit was tested and the results show that the
emission release is within the legislative requirements for emission
production and environmental protection. That qualifies such unit for
indoor application.
Abstract: Thin-walled elements with a matrix set on a base of
high-valuable Portland cement with dispersed reinforcement from
alkali-resistant glass fibres are used in a range of applications as
claddings of buildings and infrastructure constructions as well as
various architectural elements of residential buildings.
Even though their elementary thickness and therefore total weight
is quite low, architects and building companies demand on even
further decreasing of the bulk density of these fibre-cement elements
for the reason of loading elimination of connected superstructures
and easier assembling in demand conditions.
By the means of various kinds of light-weight aggregates it is
possible to achieve light-weighing of these composite elements.
From the range of possible fillers with different material properties
granulated expanded glass worked the best.
By the means of laboratory testing an effect of two fillers based on
expanded glass on the fibre reinforced cement composite was
verified.
Practical applicability was tested in the production of commonly
manufactured glass fibre reinforced concrete elements, such as
channels for electrical cable deposition, products for urban equipment
and especially various cladding elements.
Even though these are not structural elements, it is necessary to
evaluate also strength characteristics and resistance to environment
for their durability in certain applications.
Abstract: Pulmonary Function Tests are important non-invasive
diagnostic tests to assess respiratory impairments and provides
quantifiable measures of lung function. Spirometry is the most
frequently used measure of lung function and plays an essential role
in the diagnosis and management of pulmonary diseases. However,
the test requires considerable patient effort and cooperation,
markedly related to the age of patients resulting in incomplete data
sets. This paper presents, a nonlinear model built using Multivariate
adaptive regression splines and Random forest regression model to
predict the missing spirometric features. Random forest based feature
selection is used to enhance both the generalization capability and the
model interpretability. In the present study, flow-volume data are
recorded for N= 198 subjects. The ranked order of feature importance
index calculated by the random forests model shows that the
spirometric features FVC, FEF25, PEF, FEF25-75, FEF50 and the
demographic parameter height are the important descriptors. A
comparison of performance assessment of both models prove that, the
prediction ability of MARS with the `top two ranked features namely
the FVC and FEF25 is higher, yielding a model fit of R2= 0.96 and
R2= 0.99 for normal and abnormal subjects. The Root Mean Square
Error analysis of the RF model and the MARS model also shows that
the latter is capable of predicting the missing values of FEV1 with a
notably lower error value of 0.0191 (normal subjects) and 0.0106
(abnormal subjects) with the aforementioned input features. It is
concluded that combining feature selection with a prediction model
provides a minimum subset of predominant features to train the
model, as well as yielding better prediction performance. This
analysis can assist clinicians with a intelligence support system in the
medical diagnosis and improvement of clinical care.
Abstract: The development of allometric models is crucial to
accurate forest biomass/carbon stock assessment. The aim of this
study was to develop a set of biomass prediction models that will
enable the determination of total tree aboveground biomass for
savannah woodland area in Niger State, Nigeria. Based on the data
collected through biometric measurements of 1816 trees and
destructive sampling of 36 trees, five species specific and one site
specific models were developed. The sample size was distributed
equally between the five most dominant species in the study site
(Vitellaria paradoxa, Irvingia gabonensis, Parkia biglobosa,
Anogeissus leiocarpus, Pterocarpus erinaceous). Firstly, the
equations were developed for five individual species. Secondly these
five species were mixed and were used to develop an allometric
equation of mixed species. Overall, there was a strong positive
relationship between total tree biomass and the stem diameter. The
coefficient of determination (R2 values) ranging from 0.93 to 0.99 P
< 0.001 were realised for the models; with considerable low standard
error of the estimates (SEE) which confirms that the total tree above
ground biomass has a significant relationship with the dbh. F-test
values for the biomass prediction models were also significant at p
Abstract: Meeting the growth in demand for digital services
such as social media, telecommunications, and business and cloud
services requires large scale data centres, which has led to an increase
in their end use energy demand. Generally, over 30% of data centre
power is consumed by the necessary cooling overhead. Thus energy
can be reduced by improving the cooling efficiency. Air and liquid
can both be used as cooling media for the data centre. Traditional
data centre cooling systems use air, however liquid is recognised as a
promising method that can handle the more densely packed data
centres. Liquid cooling can be classified into three methods; rack heat
exchanger, on-chip heat exchanger and full immersion of the
microelectronics. This study quantifies the improvements of heat
transfer specifically for the case of immersed microelectronics by
varying the CPU and heat sink location. Immersion of the server is
achieved by filling the gap between the microelectronics and a water
jacket with a dielectric liquid which convects the heat from the CPU
to the water jacket on the opposite side. Heat transfer is governed by
two physical mechanisms, which is natural convection for the fixed
enclosure filled with dielectric liquid and forced convection for the
water that is pumped through the water jacket. The model in this
study is validated with published numerical and experimental work
and shows good agreement with previous work. The results show that
the heat transfer performance and Nusselt number (Nu) is improved
by 89% by placing the CPU and heat sink on the bottom of the
microelectronics enclosure.
Abstract: Presently, it is necessary to ensure the sustainable
development of passenger and freight transport. Increasing
performance of road freight has had a negative impact to environment
and society. It is therefore necessary to increase the competitiveness
of intermodal transport, which is more environmentally friendly. The
study describes the effectiveness of logistical centers realization for
companies and society and research how the partial internalization of
external costs reflected in the efficient use of these centers and
increase the competitiveness of intermodal transport to road freight.
In our research, we use the method of comparative analysis and
market research to describe the advantages of logistic centers for their
users as well as for society as a whole. Method normal costing is used
for calculation infrastructure and total costs, method of conversion
costing for determine the external costs. We modelled total society
costs for road freight transport and inter modal transport chain (we
assumed that most of the traffic is carried by rail) with different
loading schemes for condition in the Slovak Republic. Our research
has shown that higher utilization of inter modal transport chain do
good not only for society, but for companies providing freight
services too. Increase in use of inter modal transport chain can bring
many benefits to society that do not bring direct immediate financial
return. They often bring the multiplier effects, such as greater use of
environmentally friendly transport mode and reduce the total society
costs.
Abstract: The characteristics of temperature distribution and
electric field in a natural rubber glove (NRG) using microwave
energy during microwave heating process are investigated
numerically and experimentally. A three-dimensional model of NRG
and microwave oven are considered in this work. The influences of
position, heating time and rotation angle of NRG on temperature
distribution and electric field are presented in details. The coupled
equations of electromagnetic wave propagation and heat transfer are
solved using the finite element method (FEM). The numerical model
is validated with an experimental study at a frequency of 2.45 GHz.
The results show that the numerical results closely match the
experimental results. Furthermore, it is found that the temperature
distribution and electric field increases with increasing heating time.
The hot spot zone appears in NRG at the tip of middle finger while
the maximum temperature occurs in case of rotation angle of NRG =
60 degree. This investigation provides the essential aspects for a
fundamental understanding of heat transport of NRG using
microwave energy in industry.
Abstract: Natural hydrocarbon seepage has helped petroleum
exploration as a direct indicator of gas and/or oil subsurface
accumulations. Surface macro-seeps are generally an indication of a
fault in an active Petroleum Seepage System belonging to a Total
Petroleum System. This paper describes a case study in which
multiple analytical techniques were used to identify and characterize
trace petroleum-related hydrocarbons and other volatile organic
compounds in groundwater samples collected from Sousse aquifer
(Central Tunisia). The analytical techniques used for analyses of
water samples included gas chromatography-mass spectrometry (GCMS),
capillary GC with flame-ionization detection, Compound
Specific Isotope Analysis, Rock Eval Pyrolysis. The objective of the
study was to confirm the presence of gasoline and other petroleum
products or other volatile organic pollutants in those samples in order
to assess the respective implication of each of the potentially
responsible parties to the contamination of the aquifer. In addition,
the degree of contamination at different depths in the aquifer was also
of interest. The oil and gas seeps have been investigated using
biomarker and stable carbon isotope analyses to perform oil-oil and
oil-source rock correlations. The seepage gases are characterized by
high CH4 content, very low δ13CCH4 values (-71,9 ‰) and high
C1/C1–5 ratios (0.95–1.0), light deuterium–hydrogen isotope ratios (-
198 ‰) and light δ13CC2 and δ13CCO2 values (-23,8‰ and-23,8‰
respectively) indicating a thermogenic origin with the contribution of
the biogenic gas. An organic geochemistry study was carried out on
the more ten oil seep samples. This study includes light hydrocarbon
and biomarkers analyses (hopanes, steranes, n-alkanes, acyclic
isoprenoids, and aromatic steroids) using GC and GC-MS. The
studied samples show at least two distinct families, suggesting two
different types of crude oil origins: the first oil seeps appears to be
highly mature, showing evidence of chemical and/or biological
degradation and was derived from a clay-rich source rock deposited
in suboxic conditions. It has been sourced mainly by the lower
Fahdene (Albian) source rocks. The second oil seeps was derived
from a carbonate-rich source rock deposited in anoxic conditions,
well correlated with the Bahloul (Cenomanian-Turonian) source rock.
Abstract: Multi-Level Inverter technology has been developed in the area of high-power medium-voltage energy scheme, because of their advantages such as devices of lower rating can be used thereby enabling the schemes to be used for high voltage applications. Reduced Total Harmonic Distortion (THD).Since the dv/dt is low; the Electromagnetic Interference from the scheme is low. To avoid the switching losses Lower switching frequencies can be used. In this paper present a survey of various topologies, control strategy and modulation techniques used by these inverters. Here the regenerative and superior topologies are also discussed.