Abstract: Current air conditioning system is using refrigerant as
the cooling medium. The main purpose of this study is to develop an
air conditioning system using chill water as the cooling medium. In
this system, chill water used to replace refrigerant as the cooling
medium. This study is focus on the split type unit air conditioning
system only. It will be involving some renovation on the indoor unit
and freezer. The cooling capability of this system was validate by few
series of testing, which conducted at standard 36m3 office room.
Result of the testing found that 0.1 m3 of chill water is able to
maintain the room temperature within standard up to 4 ~ 8 hours. It
expected able to maintain room temperature up to 10 hour with some
improvement.
Abstract: Power system state estimation is the process of
calculating a reliable estimate of the power system state vector
composed of bus voltages' angles and magnitudes from telemetered
measurements on the system. This estimate of the state vector
provides the description of the system necessary for the operation
and security monitoring. Many methods are described in the
literature for solving the state estimation problem, the most important
of which are the classical weighted least squares method and the nondeterministic
genetic based method; however both showed
drawbacks. In this paper a modified version of the genetic
algorithm power system state estimation is introduced, Sensitivity of
the proposed algorithm to genetic operators is discussed, the
algorithm is applied to case studies and finally it is compared with
the classical weighted least squares method formulation.
Abstract: Building Sector is the major electricity consumer and
it is costly to building owners. Therefore the application of thermal
energy storage (TES) has gained attractive to reduce energy cost.
Many attractive tariff packages are being offered by the electricity
provider to promote TES. The tariff packages offered higher cost of
electricity during peak period and lower cost of electricity during off
peak period. This paper presented the return of initial investment by
implementing a centralized air-conditioning plant integrated with
thermal energy storage with partially operation strategies. Building
load profile will be calculated hourly according to building
specification and building usage trend. TES operation conditions will
be designed according to building load demand profile, storage
capacity, tariff packages and peak/off peak period. The Payback
Period analysis method was used to evaluate economic analysis. The
investment is considered a good investment where by the initial cost
is recovered less than ten than seven years.
Abstract: This research adapts experimental design to investigate
the effect of conditioning or not and pre-exposure or not on brand
attitude, so it is a 2×2=4 factorial design. The results show that the
brand attitude of conditioning group is significantly higher than that of
unconditioning group. The brand attitude with pre-exposure is
significantly higher than that without pre-exposure. Conditioning or
not and pre-exposure or not have significant interaction. No matter the
celebrity is pre-exposure or not, the brand attitude is higher under
conditioning process.
Abstract: Evaporator is an important and widely used heat
exchanger in air conditioning and refrigeration industries. Different
methods have been used by investigators to increase the heat transfer
rates in evaporators. One of the passive techniques to enhance heat
transfer coefficient is the application of microfin tubes. The
mechanism of heat transfer augmentation in microfin tubes is
dependent on the flow regime of two-phase flow. Therefore many
investigations of the flow patterns for in-tube evaporation have been
reported in literatures. The gravitational force, surface tension and
the vapor-liquid interfacial shear stress are known as three dominant
factors controlling the vapor and liquid distribution inside the tube. A
review of the existing literature reveals that the previous
investigations were concerned with the two-phase flow pattern for
flow boiling in horizontal tubes [12], [9]. Therefore, the objective of
the present investigation is to obtain information about the two-phase
flow patterns for evaporation of R-134a inside horizontal smooth and
microfin tubes. Also Investigation of heat transfer during flow
boiling of R-134a inside horizontal microfin and smooth tube have
been carried out experimentally The heat transfer coefficients for
annular flow in the smooth tube is shown to agree well with Gungor
and Winterton-s correlation [4]. All the flow patterns occurred in the
test can be divided into three dominant regimes, i.e., stratified-wavy
flow, wavy-annular flow and annular flow. Experimental data are
plotted in two kinds of flow maps, i.e., Weber number for the vapor
versus weber number for the liquid flow map and mass flux versus
vapor quality flow map. The transition from wavy-annular flow to
annular or stratified-wavy flow is identified in the flow maps.
Abstract: Drop-in of R-22 alternatives in refrigeration and air conditioning systems requires a redesign of system components to improve system performance and reliability with the alternative refrigerants. The present paper aims at design adiabatic capillary tubes for R-22 alternatives such as R-417A, R-422D and R-438A. A theoretical model has been developed and validated with the available experimental data from literature for R-22 over a wide range of both operating and geometrical parameters. Predicted lengths of adiabatic capillary tube are compared with the lengths of the capillary tube needed under similar experimental conditions and majority of predictions are found to be within 4.4% of the experimental data. Hence, the model has been applied for R-417A, R- 422D and R-438A and capillary tube selection charts and correlations have been computed. Finally a comparison between the selected refrigerants and R-22 has been introduced and the results showed that R-438A is the closest one to R-22.
Abstract: A novel circuit for generating a signal embedded with
features about data from three sensors is presented. This suggested
circuit is making use of a resistance-to-time converter employing a
bridge amplifier, an integrator and a comparator. The second resistive
sensor (Rz) is transformed into duty cycle. Another bridge with
varying resistor, (Ry) in the feedback of an OP AMP is added in
series to change the amplitude of the resulting signal in a proportional
relationship while keeping the same frequency and duty cycle
representing proportional changes in resistors Rx and Rz already
mentioned. The resultant output signal carries three types of
information embedded as variations of its frequency, duty cycle and
amplitude.
Abstract: The purpose of this study is to investigate the
efficiency of a double-layer roof in collecting solar energy as an
application to the areas such as raising high-end temperature of
organic Rankine cycle (ORC). The by-product of the solar roof is to
reduce building air-conditioning loads. The experimental apparatus
are arranged to evaluate the effects of the solar roof in absorbing solar
energy. The flow channel is basically formed by an aluminum plate on
top of a plywood plate. The geometric configurations in which the
effects of absorbing energy is analyzed include: a bare uncovered
aluminum plate, a glass-covered aluminum plate, a
glass-covered/black-painted aluminum plate, a plate with variable
lengths, a flow channel with stuffed material (in an attempt on
enhancement of heat conduction), and a flow channel with variable
slanted angles. The experimental results show that the efficiency of
energy collection varies from 0.6 % to 11 % for the geometric
configurations mentioned above. An additional study is carried out
using CFD simulation to investigate the effects of fins on the
aluminum plate. It shows that due to vastly enhanced heat conduction,
the efficiency can reach ~23 % if 50 fins are installed on the aluminum
plate. The study shows that a double-layer roof can efficiently absorb
solar energy and substantially reduce building air-conditioning
loads. On the high end of an organic Rankine cycle, a solar pond is
used to replace the warm surface water of the sea as OTEC (ocean
thermal energy conversion) is the driving energy for the ORC. The
energy collected from the double-layered solar roof can be pumped
into the pond and raise the pond temperature as the pond surface area is
equivalently increased by nearly one-fourth of the total area of the
double-layer solar roof. The effect of raising solar pond temperature is
especially prominent if the double-layer solar roofs are installed in a
community area.
Abstract: The present paper was concerned primarily with the
analysis, simulation of the air flow and thermal patterns in a lecture
room. The paper is devoted to numerically investigate the influence
of location and number of ventilation and air conditioning supply and
extracts openings on air flow properties in a lecture room. The work
focuses on air flow patterns, thermal behaviour in lecture room where
large number of students. The effectiveness of an air flow system is
commonly assessed by the successful removal of sensible and latent
loads from occupants with additional of attaining air pollutant at a
prescribed level to attain the human thermal comfort conditions and
to improve the indoor air quality; this is the main target during the
present paper. The study is carried out using computational fluid
dynamics (CFD) simulation techniques as embedded in the
commercially available CFD code (FLUENT 6.2). The CFD
modelling techniques solved the continuity, momentum and energy
conservation equations in addition to standard k – ε model equations
for turbulence closure.
Throughout the investigations, numerical validation is carried out by
way of comparisons of numerical and experimental results. Good
agreement is found among both predictions.
Abstract: The paper presents a computational tool developed for
the evaluation of technical and economic advantages of an innovative
cleaning and conditioning technology of fluidized bed steam/oxygen
gasifiers outlet product gas. This technology integrates into a single
unit the steam gasification of biomass and the hot gas cleaning and
conditioning system. Both components of the computational tool,
process flowsheet and economic evaluator, have been developed
under IPSEpro software. The economic model provides information
that can help potential users, especially small and medium size
enterprises acting in the regenerable energy field, to decide the
optimal scale of a plant and to better understand both potentiality and
limits of the system when applied to a wide range of conditions.
Abstract: The benefits of rooftop greenery systems (such as
energy savings, reduction of greenhouse gas emission for mitigating
climate change and maintaining sustainable development, indoor
temperature control etc.) in buildings are well recognized, however
there remains very little research conducted for quantifying the
benefits in subtropical climates such as in Australia. This study
mainly focuses on measuring/determining temperature profile and air
conditioning energy savings by implementing rooftop greenery
systems in subtropical Central Queensland in Australia. An
experimental set-up was installed at Rockhampton campus of Central
Queensland University, where two standard shipping containers (6m
x 2.4m x 2.4m) were converted into small offices, one with green
roof and one without. These were used for temperature, humidity and
energy consumption data collection. The study found that an energy
savings of up to 11.70% and temperature difference of up to 4°C can
be achieved in March in subtropical Central Queensland climate in
Australia. It is expected that more energy can be saved in peak
summer days (December/February) as temperature difference
between green roof and non-green roof is higher in December-
February.
Abstract: Certifications such as the Passive House Standard aim to reduce the final space heating energy demand of residential buildings. Space conditioning, notably heating, is responsible for nearly 70% of final residential energy consumption in Europe. There is therefore significant scope for the reduction of energy consumption through improvements to the energy efficiency of residential buildings. However, these certifications totally overlook the energy embodied in the building materials used to achieve this greater operational energy efficiency. The large amount of insulation and the triple-glazed high efficiency windows require a significant amount of energy to manufacture. While some previous studies have assessed the life cycle energy demand of passive houses, including their embodied energy, these rely on incomplete assessment techniques which greatly underestimate embodied energy and can lead to misleading conclusions. This paper analyses the embodied and operational energy demands of a case study passive house using a comprehensive hybrid analysis technique to quantify embodied energy. Results show that the embodied energy is much more significant than previously thought. Also, compared to a standard house with the same geometry, structure, finishes and number of people, a passive house can use more energy over 80 years, mainly due to the additional materials required. Current building energy efficiency certifications should widen their system boundaries to include embodied energy in order to reduce the life cycle energy demand of residential buildings.
Abstract: This paper reports work done to improve the modeling of complex processes when only small experimental data sets are available. Neural networks are used to capture the nonlinear underlying phenomena contained in the data set and to partly eliminate the burden of having to specify completely the structure of the model. Two different types of neural networks were used for the application of pulping problem. A three layer feed forward neural networks, using the Preconditioned Conjugate Gradient (PCG) methods were used in this investigation. Preconditioning is a method to improve convergence by lowering the condition number and increasing the eigenvalues clustering. The idea is to solve the modified odified problem M-1 Ax= M-1b where M is a positive-definite preconditioner that is closely related to A. We mainly focused on Preconditioned Conjugate Gradient- based training methods which originated from optimization theory, namely Preconditioned Conjugate Gradient with Fletcher-Reeves Update (PCGF), Preconditioned Conjugate Gradient with Polak-Ribiere Update (PCGP) and Preconditioned Conjugate Gradient with Powell-Beale Restarts (PCGB). The behavior of the PCG methods in the simulations proved to be robust against phenomenon such as oscillations due to large step size.
Abstract: Shortening of natural resources will impose greater
limitations of electric energy consumption in various fields including
water treatment technologies. Small water treatment installations
supplied with electric energy from solar sources are perfect example of
zero-emission technology. Possibility of solar energy application, as
one of the alternative energy resources for decontamination processes
is strongly dependent on geographical location. Various examples of
solar driven water purification systems are given and design of
solar-water treatment installation based on ozone for the geographical
conditions in Poland are presented.
Abstract: Over half of the total electricity consumption is used in buildings. Air-conditioning and electric lighting are the two main resources of electricity consumption in high rise buildings. One way to reduce electricity consumption would be to limit heat gain into buildings, therefore reduce the demand for air-conditioning during hot summer months especially in hot regions. On the other hand natural daylight can be used to reduce the use of electricity for artificial lighting. In this paper effective factors on minimizing heat gain and achieving required day light were reviewed .As daylight always accompanied by solar heat gain. Also interactions between heat gain and daylight were discussed through previous studies and equations which are related to heat gain and day lighting especially in high rise buildings. As a result importance of building-s form and its component on energy consumption in buildings were clarified.
Abstract: We present a simulation and realization of a battery
charge regulator (BCR) in microsatellite earth observation. The tests
were performed on battery pack 12volt, capacity 24Ah and the solar array open circuit voltage of 100 volt and optimum power of about
250 watt. The battery charge is made by solar module. The principle is to adapt the output voltage of the solar module to the battery by
using the technique of pulse width modulation (PWM). Among the different techniques of charge battery, we opted for the technique of
the controller ON/OFF is a standard technique and simple, it-s easy to
be board executed validation will be made by simulation "Proteus Isis
Professional software ". The circuit and the program of this prototype
are based on the PIC16F877 microcontroller, a serial interface connecting a PC is also realized, to view and save data and graphics
in real time, for visualization of data and graphs we develop an interface tool “visual basic.net (VB)--.
Abstract: The present work demonstrates the design and simulation of a fuzzy control of an air conditioning system at different pressures. The first order Sugeno fuzzy inference system is utilized to model the system and create the controller. In addition, an estimation of the heat transfer rate and water mass flow rate injection into or withdraw from the air conditioning system is determined by the fuzzy IF-THEN rules. The approach starts by generating the input/output data. Then, the subtractive clustering algorithm along with least square estimation (LSE) generates the fuzzy rules that describe the relationship between input/output data. The fuzzy rules are tuned by Adaptive Neuro-Fuzzy Inference System (ANFIS). The results show that when the pressure increases the amount of water flow rate and heat transfer rate decrease within the lower ranges of inlet dry bulb temperatures. On the other hand, and as pressure increases the amount of water flow rate and heat transfer rate increases within the higher ranges of inlet dry bulb temperatures. The inflection in the pressure effect trend occurs at lower temperatures as the inlet air humidity increases.
Abstract: This paper reports work done to improve the modeling of complex processes when only small experimental data sets are available. Neural networks are used to capture the nonlinear underlying phenomena contained in the data set and to partly eliminate the burden of having to specify completely the structure of the model. Two different types of neural networks were used for the application of Pulping of Sugar Maple problem. A three layer feed forward neural networks, using the Preconditioned Conjugate Gradient (PCG) methods were used in this investigation. Preconditioning is a method to improve convergence by lowering the condition number and increasing the eigenvalues clustering. The idea is to solve the modified problem where M is a positive-definite preconditioner that is closely related to A. We mainly focused on Preconditioned Conjugate Gradient- based training methods which originated from optimization theory, namely Preconditioned Conjugate Gradient with Fletcher-Reeves Update (PCGF), Preconditioned Conjugate Gradient with Polak-Ribiere Update (PCGP) and Preconditioned Conjugate Gradient with Powell-Beale Restarts (PCGB). The behavior of the PCG methods in the simulations proved to be robust against phenomenon such as oscillations due to large step size.
Abstract: A preconditioned Jacobi (PJ) method is provided for solving fuzzy linear systems whose coefficient matrices are crisp Mmatrices and the right-hand side columns are arbitrary fuzzy number vectors. The iterative algorithm is given for the preconditioned Jacobi method. The convergence is analyzed with convergence theorems. Numerical examples are given to illustrate the procedure and show the effectiveness and efficiency of the method.
Abstract: This paper presents a real time force sensing
instrument that is designed for human gait analysis purposes. It is
capable of recording and monitoring ground reaction forces exerted
by human foot during various activities such as walking, running and
jumping in real time. In overall, force sensing mat mainly consists of
three elements: the force sensing mat, signal conditioning circuit and
data acquisition device. Force sensing mat is the mat that contains an
array of force sensing elements. To control and process the incoming
signal from the force sensing mat, Force-Logger and Force-Reloader
are developed using National Instrument Labview. This paper
describes the architecture of the force sensing mat, signal
conditioning circuit and the real time streaming of the incoming data
from the force sensing mat. Additionally, a preliminary experiment
dataset is presented in this paper.