Abstract: Recently, there have been a lot of earthquakes in Japan.
It is necessary to promote seismic isolation devices for buildings. The
devices have been hardly diffused in attached houses, because the
devices are very expensive. We should develop a low-cost seismic
isolation device for detached houses. We suggested a new seismic
isolation device which uses a two-layer circular tube as a unit. If
hysteresis is produced in the two-layer circular tube under lateral
compression load, we think that the two-layer circular tube can have
energy absorbing capacity. It is necessary to contact the outer layer
and the inner layer to produce hysteresis. We have previously reported
how the inner layer comes in contact with the outer layer from a
perspective of analysis used mechanics of materials. We have clarified
that the inner layer comes in contact with the outer layer under a lateral
compression load. In this paper, we explored contact area between the
outer layer and the inner layer under a lateral compression load by
using FEA. We think that changing the inner layer’s thickness is
effective in increase the contact area. In order to change the inner
layer’s thickness, we changed the shape of the inner layer. As a result,
the contact area changes depending on the inner layer’s thickness.
Additionally, we experimented to check whether hysteresis occurs in
fact. As a consequence, we can reveal hysteresis in the two-layer
circular tube under the condition.
Abstract: This study has been presented which is a detailed
work of seismic microzonation of the city center. For seismic
microzonation area of 225 km2 has been selected as the study area.
MASW (Multichannel analysis of surface wave) and seismic
refraction methods have been used to generate one-dimensional shear
wave velocity profile at 250 locations and two-dimensional profile at
60 locations. These shear wave velocities are used to estimate
equivalent shear wave velocity in the study area at every 2 and 5 m
intervals up to a depth of 60 m. Levels of equivalent shear wave
velocity of soil are used the classified of the study area. After the
results of the study, it must be considered as components of urban
planning and building design of Denizli and the application and use
of these results should be required and enforced by municipal
authorities.
Abstract: The study area is Zaria, located in the basement
complex of northern Nigeria. The rock type forming the major part of
the Zaria batholith is granite. This research work was carried out to
compare the responses of seismic refraction tomography and
resistivity tomography in the same geologic environment and under
the same conditions. Hence, the choice of the site that has a visible
granitic outcrop that extends across a narrow stream channel and is
flanked by unconsolidated overburden, a neutral profile that was
covered by plain overburden and a site with thick lateritic cover
became necessary. The results of the seismic and resistivity
tomography models reveals that seismic velocity and resistivity does
not always simultaneously increase with depth, but their responses in
any geologic environment are determined by changes in the
mechanical and chemical content of the rock types rather than depth.
Abstract: A method is proposed for stable detection of
seismoacoustic sources in C-OTDR systems that guarantee given
upper bounds for probabilities of type I and type II errors. Properties
of the proposed method are rigorously proved. The results of
practical applications of the proposed method in a real C-OTDRsystem
are presented.
Abstract: High resolution seismic reflection has recently been carried out on Zaria batholith, with the aim of characterizing the granitic Zaria batholiths in terms of its lithology. The geology of the area has revealed that the older granite outcrops in the vicinity of Zaria are exposures of a syntectonics to late-tectonic granite batholiths which intruded a crystalline gneissic basement during the Pan-African Orogeny. During the data acquisition the geophone were placed at interval of 1 m, variable offset of 1 and 10 m was used. The common midpoint (CMP) method with 12 fold coverage was employed for the survey. Analysis of the generated 3D surface of the p wave velocities from different profiles for densities and bulk modulus revealed that the rock material is more consolidated in South East part of the batholith and less consolidated in the North Western part. This was in conformity with earlier identified geology of the area, with the South Eastern part majorly of granitic outcrop, while the North Western part is characterized with the exposure of gneisses and thick overburden cover. The difference in lithology was also confirmed by the difference in seismic sections and Arial satellite photograph. Hence two major lithologies were identified, the granitic and gneisses complex which are characterized by gradational boundaries.
Abstract: Tsunami early detection and warning systems have proved to be of ultimate importance, especially after the destructive tsunami that hit Japan in March 2012. Such systems are crucial to inform the authorities of any risk of a tsunami and of the degree of its danger in order to make the right decision and notify the public of the actions they need to take to save their lives. The purpose of this research is to enhance existing tsunami detection and warning systems. We first propose an automated and miniaturized model of an early tsunami detection and warning system. The model for the operation of a tsunami warning system is simulated using the data acquisition toolbox of Matlab and measurements acquired from specified internet pages due to the lack of the required real-life sensors, both seismic and hydrologic, and building a graphical user interface for the system. In the second phase of this work, we implement various satellite image filtering schemes to enhance the acquired synthetic aperture radar images of the tsunami affected region that are masked by speckle noise. This enables us to conduct a post-tsunami damage extent study and calculate the percentage damage. We conclude by proposing improvements to the existing telecommunication infrastructure of existing warning tsunami systems using a migration to IP-based networks and fiber optics links.
Abstract: There are several types of metal-based devices conceived as dampers for the seismic energy absorber whereby damages to the major structural components could be minimized for both new and existing structures. This paper aimed to develop and evaluate structural performance of slit circular shear panel damper for passive seismic energy protection by inelastic deformation. Structural evaluation was done using commercially available nonlinear FE simulation program. The main parameters considered are: diameter-to-thickness (D/t) ratio and slit length-to-width ratio (l/w). Depending on these parameters three different buckling mode and hysteretic behavior was found: yielding prior to buckling without strength degradation, yielding prior to buckling with strength degradation and yielding with buckling and strength degradation which forms pinching at initial displacement. The susceptible location at which the possible crack is initiated is also identified for selected specimens using rupture index.
Abstract: Seismic design criteria based on performance of
structures have recently been adopted by practicing engineers in
response to destructive earthquakes. A simple but efficient
structural-analysis tool capable of predicting both the strength and
ductility is needed to analyze reinforced concrete (RC) structures
under such event. A three-dimensional lattice model is developed in
this study to analyze torsions in high-strength RC members.
Optimization techniques for determining optimal variables in each
lattice model are introduced. Pure torsion tests of RC members are
performed to validate the proposed model. Correlation studies
between the numerical and experimental results confirm that the
proposed model is well capable of representing salient features of the
experimental results.
Abstract: The idea of adding metallic energy dissipaters to a structure to absorb a large part of the seismic energy began four decades ago. There are several types of metal-based devices conceived as dampers for the seismic energy absorber whereby damages to the major structural components could be minimized for both new and existing structures. This paper aimed to develop and evaluate structural performance of both stiffened and non stiffened circular shear panel damper for passive seismic energy protection by inelastic deformation. Structural evaluation was done using commercially available nonlinear FE simulation program. Diameter-to-thickness ratio is employed as main parameter to investigate the hysteresis performance of stiffened and unstiffened circular shear panel. Depending on these parameters three different buckling mode and hysteretic behavior was found: yielding prior to buckling without strength degradation, yielding prior to buckling with strength degradation and yielding with buckling and strength degradation which forms pinching at initial displacement. Hence, the hysteresis behavior is identified, specimens which deform without strength degradation so it will be used as passive energy dissipating device in civil engineering structures.
Abstract: Performance based design (PBD) is an iterative exercise in which a preliminary trial design of the building structure is selected and if the selected trial design of the building structure does not conform to the desired performance objective, the trial design is revised. In this context, development of a fundamental approach for performance based seismic design of masonry infilled frames with minimum number of trials is an important objective. The paper presents a plastic design procedure based on the energy balance concept for PBD of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames subjected to near-field earthquakes. The proposed energy based plastic design procedure was implemented for trial performance based seismic design of representative masonry infilled reinforced concrete frames with various practically relevant distributions of masonry infill panels over the frame elevation. Non-linear dynamic analyses of the trial PBD of masonry infilled R/C frames was performed under the action of near-field earthquake ground motions. The results of non-linear dynamic analyses demonstrate that the proposed energy method is effective for performance based design of masonry infilled R/C frames under near-field as well as far-field earthquakes.
Abstract: There are many researches on parameters affecting seismic behavior of steel moment frames. Great deal of these researches considers cover plate connections with or without haunch and direct beam to column connection for exterior columns. Also there are experimental results for interior connections with equal beam depth on both sides but not much research has been performed on the seismic behavior of joints with unequal beam depth. Based on previous experimental results, a series of companion analyses have been set up considering different beam height and connection detailing configuration to investigate the seismic behavior of the connections. Results of this study indicate that when the differences between beams height on both side increases, use of haunch connection system leads to significant improvement in the seismic response whereas other configurations did not provide satisfying results.
Abstract: Concentric bracing systems have been in practice for many years because of their effectiveness in reducing seismic response. Depending on concept, seismic design codes provide various response modification factors (R), which itself consists of different terms, for different types of lateral load bearing systems but configuration of these systems are often ignored in the proposed values. This study aims at considering the effect of different x-bracing diagonal configuration on values of ductility dependent term in R computation. 51 models were created and nonlinear push over analysis has been performed. The main variables of this study were the suitable location of X–bracing diagonal configurations, which establishes better nonlinear behavior in concentric braced steel frames. Results show that some x-bracing diagonal configurations improve the seismic performance of CBF significantly and explicit consideration of lateral load bearing systems seems necessary.
Abstract: Excavation of shallow tunnels such as subways in urban areas plays a significant role as a life line and investigation of the soil behavior against tunnel construction is one of the vital subjects studied in the geotechnical scope. Nowadays, urban tunnels are mostly drilled by T.B.Ms and changing the applied forces to tunnel lining is one of the most risky matters while drilling tunnels by these machines. Variation of soil cementation can change the behavior of these forces in the tunnel lining. Therefore, this article is designed to assess the impact of tunnel excavation in different soils and several amounts of cementation on applied loads to tunnel lining under static and dynamic loads. According to the obtained results, changing the cementation of soil will affect the applied loadings to the tunnel envelope significantly. It can be determined that axial force in tunnel lining decreases considerably when soil cementation increases. Also, bending moment and shear force in tunnel lining decreases as the soil cementation increases and causes bending and shear behavior of the segments to improve. Based on the dynamic analyses, as cohesion factor in soil increases, bending moment, axial and shear forces of segments decrease but lining behavior of the tunnel is the same as static state. The results show that decreasing the overburden applied to lining caused by cementation is different in two static and dynamic states.
Abstract: In this study, we estimated the seismic ground motion parameters based on microtremor measurements atPalu City. Several earthquakes have struck along the Palu-Koro Fault during recent years. The USGS epicenter, magnitude Mw 6.3 event that occurred on January 23, 2005 caused several casualties. We conducted a microtremor survey to estimate the strong ground motion distribution during the earthquake. From this surveywe produced a map of the peak ground acceleration, velocity, seismic vulnerability index and ground shear strain maps in Palu City. We performed single observations of microtremor at 151 sites in Palu City. We also conducted8-site microtremors array investigation to gain a representative determination of the soil condition of subsurface structures in Palu City.From the array observations, Palu City corresponds to relatively soil condition with Vs ≤ 300m/s, the predominant periods due to horizontal vertical ratios (HVSRs) are in the range of 0.4 to 1.8 s and the frequency are in the range of 0.7 to 3.3 Hz. Strong ground motions of the Palu area were predicted based on the empirical stochastic green’s function method. Peak ground acceleration and velocity becomes more than 400 gal and 30 kine in some areas, which causes severe damage for buildings in high probability. Microtremor survey results showed that in hilly areas had low seismic vulnerability index and ground shear strain, whereas in coastal alluvium was composed of material having a high seismic vulnerability and ground shear strain indication.
Abstract: This paper presents a comparative study of static analysis procedure for seismic performance based on UBC-1997 and SBC-301-2007(Saudi Arabia). These building codes define different ductility classes and corresponding response reduction factors based on material, configuration and detailing of reinforcements. Codes differ significantly in specifying the procedures to estimate base shear, drift and effective stiffness of structural members. One of the major improvements made in new SBC (based on IBC-2003) is ground motion parameters used for seismic design. In old SBC (based on UBC) maps have been based on seismic zones. However new SBC provide contour maps giving spectral response quantities. In this approach, a case study of RC frame building located in two different cities and with different ductility classes has been performed. Moreover, equivalent static method based on SBC-301 and UBC-1997 is used to explore the variation in results based on two codes, particularly design base shear, lateral loads and story drifts.
Abstract: The modern energy-efficient houses are often founded on a thermal insulation (TI) layer placed under the building’s RC foundation slab.The purpose of the paper is to identify the potential problems of the buildings founded on TI layer from the seismic point of view. The two main goals of the study were to assess the seismic behavior of such buildings, and to search for the critical structural parameters affecting the response of the superstructure as well as of the extruded polystyrene (XPS) layer. As a test building a multi-storeyed RC frame structure with and without the XPS layer under the foundation slab has been investigated utilizing nonlinear dynamic (time-history) and static (pushover) analyses. The structural response has been investigated with reference to the following performance parameters: i) Building’s lateral roof displacements, ii) Edge compressive and shear strains of the XPS, iii) Horizontal accelerations of the superstructure, iv) Plastic hinge patterns of the superstructure, v) Part of the foundation in compression, and vi) Deformations of the underlying soil and vertical displacements of the foundation slab (i.e. identifying the potential uplift). The results have shown that in the case of higher and stiff structures lying on firm soil the use of XPS under the foundation slab might induce amplified structural peak responses compared to the building models without XPS under the foundation slab. The analysis has revealed that the superstructure as well as the XPS response is substantially affected by the stiffness of the foundation slab.
Abstract: Building code-related literature provides
recommendations on normalizing approaches to the calculation of
the dynamic properties of structures. Most building codes make a
distinction among types of structural systems, construction material,
and configuration through a numerical coefficient in the
expression for the fundamental period. The period is then used in
normalized response spectra to compute base shear. The typical
parameter used in simplified code formulas for the fundamental
period is overall building height raised to a power determined from
analytical and experimental results. However, reinforced concrete
buildings which constitute the majority of built space in less
developed countries pose additional challenges to the ones built with
homogeneous material such as steel, or with concrete under stricter
quality control. In the present paper, the particularities of reinforced
concrete buildings are explored and related to current methods of
equivalent static analysis. A comparative study is presented between
the Uniform Building Code, commonly used for buildings within
and outside the USA, and data from the Middle East used to model
151 reinforced concrete buildings of varying number of bays, number
of floors, overall building height, and individual story height. The
fundamental period was calculated using eigenvalue matrix
computation. The results were also used in a separate regression
analysis where the computed period serves as dependent variable,
while five building properties serve as independent variables. The
statistical analysis shed light on important parameters that simplified
code formulas need to account for including individual story height,
overall building height, floor plan, number of bays, and concrete
properties. Such inclusions are important for reinforced concrete
buildings of special conditions due to the level of concrete damage,
aging, or materials quality control during construction.
Overall results of the present analysis show that simplified code
formulas for fundamental period and base shear may be applied but
they require revisions to account for multiple parameters. The
conclusion above is confirmed by the analytical model where
fundamental periods were computed using numerical techniques and
eigenvalue solutions. This recommendation is particularly relevant
to code upgrades in less developed countries where it is customary to
adopt, and mildly adapt international codes.
We also note the necessity of further research using empirical data
from buildings in Lebanon that were subjected to severe damage due
to impulse loading or accelerated aging. However, we excluded this
study from the present paper and left it for future research as it has its
own peculiarities and requires a different type of analysis.
Abstract: Seismic retrofitting of important structures is essential in seismological active zones. The importance is doubled when it comes to some buildings like schools, hospitals, bridges etc. because they are required to continue their serviceability even after a major earthquake. Generally, seismic retrofitting codes have paid little attention to retrofitting of foundations due to its construction complexity. In this paper different methods for seismic retrofitting of tall buildings’ foundations will be discussed and evaluated. Foundations are considered in three different categories. First, foundations those are in danger of liquefaction of their underlying soil. Second, foundations located on slopes in seismological active regions. Third, foundations designed according to former design codes and may show structural defects under earthquake loads. After describing different methods used in different countries for retrofitting of the existing foundations in seismological active regions, comprehensive comparison between these methods with regard to the above mentioned categories is carried out. This paper gives some guidelines to choose the best method for seismic retrofitting of tall buildings’ foundations in retrofitting projects.
Abstract: A scheme integrated with deterministic–stochastic subspace system identification and the method of damage localization vector is proposed in this study for damage detection of structures based on seismic response data. A series of shaking table tests using a five-storey steel frame has been conducted in National Center for Research on Earthquake Engineering (NCREE), Taiwan. Damage condition is simulated by reducing the cross-sectional area of some of the columns at the bottom. Both single and combinations of multiple damage conditions at various locations have been considered. In the system identification analysis, either full or partial observation conditions have been taken into account. It has been shown that the damaged stories can be identified from global responses of the structure to earthquakes if sufficiently observed. In addition to detecting damage(s) with respect to the intact structure, identification of new or extended damages of the as-damaged (ill-conditioned) counterpart has also been studied. The proposed scheme proves to be effective.
Abstract: This paper focuses on assessing sloshing-induced overflow of the seismically-isolated nuclear tanks based on Fluid-Structure Interaction (FSI) analysis. Typically, fluid motion in the seismically-isolated nuclear tank systems may be rather amplified and even overflowed under earthquake. Sloshing-induced overflow in those structures has to be reliably assessed and predicted since it can often cause critical damages to humans and environments. FSI analysis is herein performed to compute the total cumulative overflowed water volume more accurately, by coupling ANSYS with CFX for structural and fluid analyses, respectively. The approach is illustrated on a nuclear liquid storage tank, Spent Fuel Pool (SFP), forgiven conditions under consideration: different liquid levels, Peak Ground Accelerations (PGAs), and post earthquakes.