Abstract: The counter flow solar air heaters, with four
transverse fins and wire mesh layers are constructed and investigated
experimentally for thermal efficiency at a geographic location of
Cyprus in the city of Famagusta. The absorber plate is replaced by
sixteen steel wire mesh layers, 0.18 x 0.18cm in cross section
opening and a 0.02cm in diameter. The wire mesh layers arranged in
three groups, first and second include 6 layers, while the third include
4 layers. All layers fixed in the duct parallel to the glazing and each
group separated from the others by wood frame thickness of 0.5cm to
reduce the pressure drop. The transverse fins arranged in a way to
force the air to flow through the bed like eight letter path with flow
depth 3cm. The proposed design has increased the heat transfer rate,
but on other hand causes a high pressure drop. The obtained results
show that, for air mass flow rate range between 0.011-0.036kg/s, the
thermal efficiency increases with increasing the air mass flow. The
maximum efficiency obtained is 65.6% for the mass flow rate of
0.036kg/s. Moreover, the temperature difference between the outlet
flow and the ambient temperature, ΔT, reduces as the air mass flow
rate increase. The maximum difference between the outlet and
ambient temperature obtained was 43°C for double pass for minimum
mass flow rate of 0.011kg/s. Comparison with a conventional solar
air heater collector shows a significantly development in the thermal
efficiency.
Abstract: The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.
Abstract: In this paper, design, fabrication and coupled
multifield analysis of hollow out-of-plane silicon microneedle array
with piezoelectrically actuated microfluidic device for transdermal
drug delivery (TDD) applications is presented. The fabrication
process of silicon microneedle array is first done by series of
combined isotropic and anisotropic etching processes using
inductively coupled plasma (ICP) etching technology. Then coupled
multifield analysis of MEMS based piezoelectrically actuated device
with integrated 2×2 silicon microneedle array is presented. To predict
the stress distribution and model fluid flow in coupled field analysis,
finite element (FE) and computational fluid dynamic (CFD) analysis
using ANSYS rather than analytical systems has been performed.
Static analysis and transient CFD analysis were performed to predict
the fluid flow through the microneedle array. The inlet pressure from
10 kPa to 150 kPa was considered for static CFD analysis. In the
lumen region fluid flow rate 3.2946 μL/min is obtained at 150 V for
2×2 microneedle array. In the present study the authors have
performed simulation of structural, piezoelectric and CFD analysis
on three dimensional model of the piezoelectrically actuated
mcirofluidic device integrated with 2×2 microneedle array.
Abstract: The possibility of producing drinking water from
brackish ground water using Vacuum membrane distillation (VMD)
process was studied. It is a rising technology for seawater or brine
desalination process. The process simply consists of a flat sheet
hydrophobic micro porous PTFE membrane and diaphragm vacuum
pump without a condenser for the water recovery or trap. In this
work, VMD performance was investigated for aqueous NaCl solution
and natural ground water. The influence of operational parameters
such as feed flow rate (30 to 55 l/h), feed temperature (313 to 333 K),
feed salt concentration (5000 to 7000 mg/l) and permeate pressure
(1.5 to 6 kPa) on the membrane distillation (MD) permeation flux
have been investigated. The maximum flux reached to 28.34 kg/m2 h
at feed temperature, 333 K; vacuum pressure, 1.5 kPa; feed flow rate,
55 l/h and feed salt concentration, 7000 mg/l. The negligible effects
in the reduction of permeate flux found over 150 h experimental run
for salt water. But for the natural ground water application over 75 h,
scale deposits observed on the membrane surface and 29% reduction
in the permeate flux over 75 h. This reduction can be eliminated by
acidification of feed water. Hence, promote the research attention in
apply of VMD for the ground water purification over today-s
conventional RO operation.
Abstract: The article deals with pneumatic and hot wire
anemometry measurement on subsonic axi-symmetric air ejector.
Performances of the ejector with and without pulsations of primary
flow are compared, measuring of characteristic pressures and mass
flow rates are performed and ejector efficiency is evaluated. The
pulsations of primary flow are produced by a synthetic jet generator,
which is placed in the supply line of the primary flow just in front of
the primary nozzle. The aim of the pulsation is to intensify the
mixing process. In the article we present: Pressure measuring of
pulsation on the mixing chamber wall, behind the mixing chamber
and behind the diffuser measured by fast pressure transducers and
results of hot wire anemometry measurement. It was found out that
using of primary flow pulsations yields higher back pressure behind
the ejector and higher efficiency. The processes in this ejector and
influences of primary flow pulsations on the mixing processes are
described.
Abstract: This study investigates the electrical performance of a
planar solid oxide fuel cell unit with cross-flow configuration when the fuel utilization gets higher and the fuel inlet flow are non-uniform.
A software package in this study solves two-dimensional,
simultaneous, partial differential equations of mass, energy, and
electro-chemistry, without considering stack direction variation. The
results show that the fuel utilization increases with a decrease in the molar flow rate, and the average current density decreases when the
molar flow rate drops. In addition, non-uniform Pattern A will induce more severe happening of non-reaction area in the corner of the fuel
exit and the air inlet. This non-reaction area deteriorates the average
current density and then deteriorates the electrical performance to –7%.
Abstract: Vacuum membrane distillation (VMD) process can be
used for water purification or the desalination of salt water. The
process simply consists of a flat sheet hydrophobic micro porous
PTFE membrane and diaphragm vacuum pump without a condenser
for the water recovery or trap. The feed was used aqueous NaCl
solution. The VMD experiments were performed to evaluate the heat
and mass transfer coefficient of the boundary layer in a membrane
module. The only operating parameters are feed inlet temperature,
and feed flow rate were investigated. The permeate flux was strongly
affected by the feed inlet temperature, feed flow rate, and boundary
layer heat transfer coefficient. Since lowering the temperature
polarization coefficient is essential enhance the process performance
considerable and maximizing the heat transfer coefficient for
maximizes the mass flux of distillate water. In this paper, the results
of VMD experiments are used to measure the boundary layer heat
transfer coefficient, and the experimental results are used to reevaluate
the empirical constants in the Dittus- Boelter equation.
Abstract: The utilize of renewable energy sources becomes
more crucial and fascinatingly, wider application of renewable
energy devices at domestic, commercial and industrial levels is not
only affect to stronger awareness but also significantly installed
capacities. Moreover, biomass principally is in form of woods and
converts to be energy for using by humans for a long time.
Gasification is a process of conversion of solid carbonaceous fuel
into combustible gas by partial combustion. Many gasified models
have various operating conditions because the parameters kept in
each model are differentiated. This study applied the experimental
data including three inputs variables including biomass consumption;
temperature at combustion zone and ash discharge rate and gas flow
rate as only one output variable. In this paper, response surface
methods were applied for identification of the gasified system
equation suitable for experimental data. The result showed that linear
model gave superlative results.
Abstract: Roundabout work on the principle of circulation and
entry flows, where the maximum entry flow rates depend largely on
circulating flow bearing in mind that entry flows must give away to
circulating flows. Where an existing roundabout has a road hump
installed at the entry arm, it can be hypothesized that the kinematics
of vehicles may prevent the entry arm from achieving optimum
performance. Road humps are traffic calming devices placed across
road width solely as speed reduction mechanism. They are the
preferred traffic calming option in Malaysia and often used on single
and dual carriageway local routes. The speed limit on local routes is
30mph (50 km/hr). Road humps in their various forms achieved the
biggest mean speed reduction (based on a mean speed before traffic
calming of 30mph) of up to 10mph or 16 km/hr according to the UK
Department of Transport. The underlying aim of reduced speed
should be to achieve a 'safe' distribution of speeds which reflects the
function of the road and the impacts on the local community.
Constraining safe distribution of speeds may lead to poor drivers
timing and delayed reflex reaction that can probably cause accident.
Previous studies on road hump impact have focused mainly on speed
reduction, traffic volume, noise and vibrations, discomfort and delay
from the use of road humps. The paper is aimed at optimal entry and
circulating flow induced by road humps. Results show that
roundabout entry and circulating flow perform better in
circumstances where there is no road hump at entrance.
Abstract: In designing of condensers, the prediction of pressure
drop is as important as the prediction of heat transfer coefficient.
Modeling of two phase flow, particularly liquid – vapor flow under
diabatic conditions inside a horizontal tube using CFD analysis is
difficult with the available two phase models in FLUENT due to
continuously changing flow patterns. In the present analysis, CFD
analysis of two phase flow of refrigerants inside a horizontal tube of
inner diameter, 0.0085 m and 1.2 m length is carried out using
homogeneous model under adiabatic conditions. The refrigerants
considered are R22, R134a and R407C. The analysis is performed at
different saturation temperatures and at different flow rates to
evaluate the local frictional pressure drop. Using Homogeneous
model, average properties are obtained for each of the refrigerants
that is considered as single phase pseudo fluid. The so obtained
pressure drop data is compared with the separated flow models
available in literature.
Abstract: The operation performance of a valveless micro-pump
is strongly dependent on the shape of connected nozzle/diffuser and
Reynolds number. The aims of present work are to compare the
performance curves of micropump with the original straight
nozzle/diffuser and contoured nozzle/diffuser under different back
pressure conditions. The tested valveless micropumps are assembled
of five pieces of patterned PMMA plates with hot-embracing
technique. The structures of central chamber, the inlet/outlet
reservoirs and the connected nozzle/diffuser are fabricated with laser
cutting machine. The micropump is actuated with circular-type PZT
film embraced on the bottom of central chamber. The deformation of
PZT membrane with various input voltages is measured with a
displacement laser probe. A simple testing facility is also constructed
to evaluate the performance curves for comparison.
In order to observe the evaluation of low Reynolds number
multiple vortex flow patterns within the micropump during suction
and pumping modes, the unsteady, incompressible laminar
three-dimensional Reynolds-averaged Navier-Stokes equations are
solved. The working fluid is DI water with constant thermo-physical
properties. The oscillating behavior of PZT film is modeled with the
moving boundary wall in way of UDF program. With the dynamic
mesh method, the instants pressure and velocity fields are obtained
and discussed.Results indicated that the volume flow rate is not
monotony increased with the oscillating frequency of PZT film,
regardless of the shapes of nozzle/diffuser. The present micropump
can generate the maximum volume flow rate of 13.53 ml/min when
the operation frequency is 64Hz and the input voltage is 140 volts.
The micropump with contoured nozzle/diffuser can provide 7ml/min
flow rate even when the back pressure is up to 400 mm-H2O. CFD
results revealed that the flow central chamber was occupied with
multiple pairs of counter-rotating vortices during suction and
pumping modes. The net volume flow rate over a complete
oscillating periodic of PZT
Abstract: Three sulphonic acid-doped polyanilines were
synthesized through chemical oxidation at low temperature (0-5 oC)
and potential of these polymers as sensing agent for O2 gas detection
in terms of fluorescence quenching was studied. Sulphuric acid,
dodecylbenzene sulphonic acid (DBSA) and camphor sulphonic acid
(CSA) were used as doping agents. All polymers obtained were dark
green powder. Polymers obtained were characterized by Fourier
transform infrared spectroscopy, ultraviolet-visible absorption
spectroscopy, thermogravimetry analysis, elemental analysis,
differential scanning calorimeter and gel permeation
chromatography. Characterizations carried out showed that polymers
were successfully synthesized with mass recovery for sulphuric aciddoped
polyaniline (SPAN), DBSA-doped polyaniline (DBSA-doped
PANI) and CSA-doped polyaniline (CSA-doped PANI) of 71.40%,
75.00% and 39.96%, respectively. Doping level of SPAN, DBSAdoped
PANI and CSA-doped PANI were 32.86%, 33.13% and
53.96%, respectively as determined based on elemental analysis.
Sensing test was carried out on polymer sample in the form of
solution and film by using fluorescence spectrophotometer. Samples
of polymer solution and polymer film showed positive response
towards O2 exposure. All polymer solutions and films were fully
regenerated by using N2 gas within 1 hour period. Photostability
study showed that all samples of polymer solutions and films were
stable towards light when continuously exposed to xenon lamp for 9
hours. The relative standard deviation (RSD) values for SPAN
solution, DBSA-doped PANI solution and CSA-doped PANI
solution for repeatability were 0.23%, 0.64% and 0.76%,
respectively. Meanwhile RSD values for reproducibility were 2.36%,
6.98% and 1.27%, respectively. Results for SPAN film, DBSAdoped
PANI film and CSA-doped PANI film showed the same
pattern with RSD values for repeatability of 0.52%, 4.05% and
0.90%, respectively. Meanwhile RSD values for reproducibility were
2.91%, 10.05% and 7.42%, respectively. The study on effect of the
flow rate on response time was carried out using 3 different rates
which were 0.25 mL/s, 1.00 mL/s and 2.00 mL/s. Results obtained
showed that the higher the flow rate, the shorter the response time.
Abstract: The quantitative determination of several trace
elements (Cr, As, Se, Cd, Hg, Pb) existing as inorganic impurities in
some oriental herb-products such as Lingzhi Mushroom capsules,
Philamin powder, etc using ICP-MS has been studied. Various
instrumental parameters such as power, gas flow rate, sample depth, as
well as the concentration of nitric acid and thick background due to
high concentration of possible interferences on the determination of
these above-mentioned elements was investigated and the optimum
working conditions of the sample measurement on ICP-MS
(Agilent-7500a) were reported. Appropriate isotope internal standards
were also used to improve the accuracy of mercury determination.
Optimal parameters for sampling digestion were also investigated. The
recovery of analytical procedure was examined by using a Certified
Reference Material (IAEA-CRM 359). The recommended procedure
was then applied for the quantitative determination of Cr, As, Se, Cd,
Hg, Pb in Lingzhi Mushroom capsule, and Philamine powder samples.
The reproducibility of sample measurement (average value between
94 and 102%) and the uncertainty of analytical data (less than 20%)
are acceptable.
Abstract: Observations show that power plant efficiency
decreases in hot summer days. Water droplet injection in air
condensers is suggested in order to decrease the inlet air temperature.
Nozzle arrangement, injected water flow rate and droplets diameter
effects on evaporation rate and the resulting air temperature are
investigated using numerical simulation. Decreasing the diameter of
injected droplets and increasing the number of injecting nozzles,
decreases the outlet air temperature. Also a more uniform air
temperature can be obtained using more injecting nozzles. Numerical
results are in good agreement with analytical results.
Abstract: Natural ventilation is an important means to improve indoor thermal comfort and reduce the energy consumption. A solar chimney system is an enhancing natural draft device, which uses solar radiation to heat the air inside the chimney, thereby converting the thermal energy into kinetic energy. The present study considered some parameters such as chimney width and solar intensity, which were believed to have a significant effect on space ventilation. Fluent CFD software was used to predict buoyant air flow and flow rates in the cavities. The results were compared with available published experimental and theoretical data from the literature. There was an acceptable trend match between the present results and the published data for the room air change per hour, ACH. Further, it was noticed that the solar intensity has a more significant effect on ACH.
Abstract: A steady two-phase flow model has been developed to simulate the drying process of porous particle in a pneumatic conveying dryer. The model takes into account the momentum, heat and mass transfer between the continuous phase and the dispersed phase. A single particle model was employed to calculate the evaporation rate. In this model the pore structure is simplified to allow the dominant evaporation mechanism to be readily identified at all points within the duct. The predominant mechanism at any time depends upon the pressure, temperature and the diameter of pore from which evaporating is occurring. The model was validated against experimental studies of pneumatic transport at low and high speeds as well as pneumatic drying. The effects of operating conditions on the dryer parameters are studied numerically. The present results show that the drying rate is enhanced as the inlet gas temperature and the gas flow rate increase and as the solid mass flow rate deceases. The present results also demonstrate the necessity of measuring the inlet gas velocity or the solid concentration in any experimental analysis.
Abstract: Subcritical water extraction was investigated as a
novel and alternative technology in the food and pharmaceutical
industry for the separation of Mannitol from olive leaves and its
results was compared with those of Soxhlet extraction. The effects of
temperature, pressure, and flow rate of water and also momentum
and mass transfer dimensionless variables such as Reynolds and
Peclet Numbers on extraction yield and equilibrium partition
coefficient were investigated. The 30-110 bars, 60-150°C, and flow
rates of 0.2-2 mL/min were the water operating conditions. The
results revealed that the highest Mannitol yield was obtained at
100°C and 50 bars. However, extraction of Mannitol was not
influenced by the variations of flow rate. The mathematical modeling
of experimental measurements was also investigated and the model is
capable of predicting the experimental measurements very well. In
addition, the results indicated higher extraction yield for the
subcritical water extraction in contrast to Soxhlet method.
Abstract: Adhesion strength of exterior or interior coating of
steel pipes is too important. Increasing of coating adhesion on
surfaces can increase the life time of coating, safety factor of
transmitting line pipe and decreasing the rate of corrosion and costs.
Preparation of steel pipe surfaces before doing the coating process is
done by shot and grit blasting. This is a mechanical way to do it.
Some effective parameters on that process, are particle size of
abrasives, distance to surface, rate of abrasive flow, abrasive physical
properties, shapes, selection of abrasive, kind of machine and its
power, standard of surface cleanness degree, roughness, time of
blasting and weather humidity. This search intended to find some
better conditions which improve the surface preparation, adhesion
strength and corrosion resistance of coating. So, this paper has
studied the effect of varying abrasive flow rate, changing the
abrasive particle size, time of surface blasting on steel surface
roughness and over blasting on it by using the centrifugal blasting
machine. After preparation of numbers of steel samples (according to
API 5L X52) and applying epoxy powder coating on them, to
compare strength adhesion of coating by Pull-Off test. The results
have shown that, increasing the abrasive particles size and flow rate,
can increase the steel surface roughness and coating adhesion
strength but increasing the blasting time can do surface over blasting
and increasing surface temperature and hardness too, change,
decreasing steel surface roughness and coating adhesion strength.
Abstract: The new semi-experimental method for simulation of
the turbine flow meters rotation in the transitional flow has been
developed. The method is based on the experimentally established
exponential low of changing of dimensionless relative turbine gas
meter rotation frequency and meter inertia time constant. For
experimental evaluation of the meter time constant special facility
has been developed. The facility ensures instant switching of turbine
meter under test from one channel to the other channel with different
flow rate and measuring the meter response. The developed method
can be used for evaluation and predication of the turbine meters
response and dynamic error in the transitional flow with any arbitrary
law of flow rate changing. The examples of the method application
are presented.
Abstract: Natural pozzolan (NP) is one of the potential
prehistoric alternative binders in the construction industry. It has
been investigated as cement replacement in ordinary concrete by
several researchers for many purposes. Various supplementary
cementitious materials (SCMs) such as fly ash, limestone dust and
silica fume are widely used in the production of SCC; however,
limited studies to address the effect of NP on the properties of SCC
are documented. The current research is composed of different SCC
paste and concrete mixtures containing different replacement levels
of local NP as an alternative SCM. The effect of volume of paste
containing different amounts of local NP related to W/B ratio and
cement content on SCC fresh properties was assessed. The variations
in the fresh properties of SCC paste and concrete represented by
slump flow (flowability) and the flow rate were determined and
discussed. The results indicated that the flow properties of SCC paste
and concrete mixtures, at their optimized superplasticizer dosages,
were affected by the binder content of local NP and the total volume
fraction of SCC paste.