The New Semi-Experimental Method for Simulation of Turbine Flow Meters Rotation in the Transitional Flow
The new semi-experimental method for simulation of
the turbine flow meters rotation in the transitional flow has been
developed. The method is based on the experimentally established
exponential low of changing of dimensionless relative turbine gas
meter rotation frequency and meter inertia time constant. For
experimental evaluation of the meter time constant special facility
has been developed. The facility ensures instant switching of turbine
meter under test from one channel to the other channel with different
flow rate and measuring the meter response. The developed method
can be used for evaluation and predication of the turbine meters
response and dynamic error in the transitional flow with any arbitrary
law of flow rate changing. The examples of the method application
are presented.
[1] W.F.Z. Lee, M.J.Kirik, B.Millington. Gas turbine flow meter
measurement in pulsating flow. Eng. Power, Trans. ASME. 1975,
October, pp 531-539.
[2] N. Lehmann. Dynamisches Verhalten von Turbinenradgaszahlern, Das
Gas und Wasserfach -GWF- 131 1990 Nr.4 Gas Erdgas, s 160-167.
[3] Technische Richtlinien Messgeräte für Gas (PTB) G13, 1994-12.
[4] N. Atkinson K. A software tool to calculate the overregistration error of
a turbine meter in pulsating flow, Flow Meas. Instrum. 1992, 3 No 3, pp
167-172.
[5] ISO/TR 3313:1998(E) Measurement of fluid flow in closed conduits -
Guidelines on the effects of flow pulsations on flow-measurement
instruments.
[6] R. J. McKee. Pulsation effects on single- and two rotor turbine meters,
Flow Meas. Instrum. 1992, 3 No 3, pp 151-166.
[7] B. Lee, R. Cheesewright, C. Clark The dynamic response of small
turbine flow meters in liquid flows, Flow Meas. Instrum. 2004, 15 No 5-
6, pp 239-248.
[8] A. G. Guchmð░n, A.A. Guchmð░n, ðÉ. ðÉ. Zaitsev. Generalized analysis. -
M.: Factorial Press, 1998.- pp.304
[9] C. R. Sparks R. J. McKee. Method and apparatus for assessing and
quantifying pulsation induced error in gas turbine flow meters. - US
patent Number 5,481,924, Jan.9, 1998.- pp.304
[10] P. P. Kremlevskiy. Flow meters and substance quantity meters.
Reference book. Part One. - S.-Pb.: Politechnika, 2002.- p.297.
[1] W.F.Z. Lee, M.J.Kirik, B.Millington. Gas turbine flow meter
measurement in pulsating flow. Eng. Power, Trans. ASME. 1975,
October, pp 531-539.
[2] N. Lehmann. Dynamisches Verhalten von Turbinenradgaszahlern, Das
Gas und Wasserfach -GWF- 131 1990 Nr.4 Gas Erdgas, s 160-167.
[3] Technische Richtlinien Messgeräte für Gas (PTB) G13, 1994-12.
[4] N. Atkinson K. A software tool to calculate the overregistration error of
a turbine meter in pulsating flow, Flow Meas. Instrum. 1992, 3 No 3, pp
167-172.
[5] ISO/TR 3313:1998(E) Measurement of fluid flow in closed conduits -
Guidelines on the effects of flow pulsations on flow-measurement
instruments.
[6] R. J. McKee. Pulsation effects on single- and two rotor turbine meters,
Flow Meas. Instrum. 1992, 3 No 3, pp 151-166.
[7] B. Lee, R. Cheesewright, C. Clark The dynamic response of small
turbine flow meters in liquid flows, Flow Meas. Instrum. 2004, 15 No 5-
6, pp 239-248.
[8] A. G. Guchmð░n, A.A. Guchmð░n, ðÉ. ðÉ. Zaitsev. Generalized analysis. -
M.: Factorial Press, 1998.- pp.304
[9] C. R. Sparks R. J. McKee. Method and apparatus for assessing and
quantifying pulsation induced error in gas turbine flow meters. - US
patent Number 5,481,924, Jan.9, 1998.- pp.304
[10] P. P. Kremlevskiy. Flow meters and substance quantity meters.
Reference book. Part One. - S.-Pb.: Politechnika, 2002.- p.297.
@article{"International Journal of Mechanical, Industrial and Aerospace Sciences:55132", author = "J. Tonkonogij and A. Pedišius and A. Stankevičius", title = "The New Semi-Experimental Method for Simulation of Turbine Flow Meters Rotation in the Transitional Flow", abstract = "The new semi-experimental method for simulation of
the turbine flow meters rotation in the transitional flow has been
developed. The method is based on the experimentally established
exponential low of changing of dimensionless relative turbine gas
meter rotation frequency and meter inertia time constant. For
experimental evaluation of the meter time constant special facility
has been developed. The facility ensures instant switching of turbine
meter under test from one channel to the other channel with different
flow rate and measuring the meter response. The developed method
can be used for evaluation and predication of the turbine meters
response and dynamic error in the transitional flow with any arbitrary
law of flow rate changing. The examples of the method application
are presented.", keywords = "Dynamic error, pulsing flow, numerical simulation,response, turbine gas meters.", volume = "2", number = "4", pages = "452-6", }