Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: In this paper, synchronization of multiple chaotic
semiconductor lasers is achieved by appealing to complex system
theory. In particular, we consider dynamical networks composed by
semiconductor laser, as interconnected nodes, where the interaction
in the networks are defined by coupling the first state of each node.
An interest case is synchronized with master-slave configuration in
star topology. Nodes of these networks are modeled for the laser and
simulate by Matlab. These results are applicable to private
communication.
Abstract: There are a number of Distributed Generations (DGs)
installed in microgrid, which may have diverse path and direction of
power flow or fault current. The overcurrent protection scheme for the
traditional radial type distribution system will no longer meet the
needs of microgrid protection. Integrating the Intelligent Electronic
Device (IED) and a Supervisory Control and Data Acquisition
(SCADA) with IEC 61850 communication protocol, the paper
proposes a Microgrid Protection Management System (MPMS) to
protect power system from the fault. In the proposed method, the
MPMS performs logic programming of each IED to coordinate their
tripping sequence. The GOOSE message defined in IEC 61850 is used
as the transmission information medium among IEDs. Moreover, to
cope with the difference in fault current of microgrid between
grid-connected mode and islanded mode, the proposed MPMS applies
the group setting feature of IED to protect system and robust
adaptability. Once the microgrid topology varies, the MPMS will
recalculate the fault current and update the group setting of IED.
Provided there is a fault, IEDs will isolate the fault at once. Finally, the
Matlab/Simulink and Elipse Power Studio software are used to
simulate and demonstrate the feasibility of the proposed method.
Abstract: This paper presents a novel algorithm for modeling
photovoltaic based distributed generators for the purpose of optimal
planning of distribution networks. The proposed algorithm utilizes
sequential Monte Carlo method in order to accurately consider the
stochastic nature of photovoltaic based distributed generators. The
proposed algorithm is implemented in MATLAB environment and
the results obtained are presented and discussed.
Abstract: This paper introduces a method to optimal design of a
hybrid Wind/Photovoltaic/Fuel cell generation system for a typical
domestic load that is not located near the electricity grid. In this
configuration the combination of a battery, an electrolyser, and a
hydrogen storage tank are used as the energy storage system. The aim
of this design is minimization of overall cost of generation scheme
over 20 years of operation. The Matlab/Simulink is applied for
choosing the appropriate structure and the optimization of system
sizing. A teaching learning based optimization is used to optimize the
cost function. An overall power management strategy is designed for
the proposed system to manage power flows among the different
energy sources and the storage unit in the system. The results have
been analyzed in terms of technical and economic. The simulation
results indicate that the proposed hybrid system would be a feasible
solution for stand-alone applications at remote locations.
Abstract: Electrohydraulic servo system have been used in
industry in a wide number of applications. Its dynamics are highly
nonlinear and also have large extent of model uncertainties and
external disturbances. In this paper, a robust back-stepping control
(RBSC) scheme is proposed to overcome the problem of disturbances
and system uncertainties effectively and to improve the tracking
performance of EHS systems. In order to implement the proposed
control scheme, the system uncertainties in EHS systems are
considered as total leakage coefficient and effective oil volume. In
addition, in order to obtain the virtual controls for stabilizing system,
the update rule for the system uncertainty term is induced by
the Lyapunov control function (LCF). To verify the performance and
robustness of the proposed control system, computer simulation of
the proposed control system using Matlab/Simulink Software
is executed. From the computer simulation, it was found that the
RBSC system produces the desired tracking performance and has
robustness to the disturbances and system uncertainties of EHS
systems.
Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: Speaker Identification (SI) is the task of establishing
identity of an individual based on his/her voice characteristics. The SI
task is typically achieved by two-stage signal processing: training and
testing. The training process calculates speaker specific feature
parameters from the speech and generates speaker models
accordingly. In the testing phase, speech samples from unknown
speakers are compared with the models and classified. Even though
performance of speaker identification systems has improved due to
recent advances in speech processing techniques, there is still need of
improvement. In this paper, a Closed-Set Tex-Independent Speaker
Identification System (CISI) based on a Multiple Classifier System
(MCS) is proposed, using Mel Frequency Cepstrum Coefficient
(MFCC) as feature extraction and suitable combination of vector
quantization (VQ) and Gaussian Mixture Model (GMM) together
with Expectation Maximization algorithm (EM) for speaker
modeling. The use of Voice Activity Detector (VAD) with a hybrid
approach based on Short Time Energy (STE) and Statistical
Modeling of Background Noise in the pre-processing step of the
feature extraction yields a better and more robust automatic speaker
identification system. Also investigation of Linde-Buzo-Gray (LBG)
clustering algorithm for initialization of GMM, for estimating the
underlying parameters, in the EM step improved the convergence rate
and systems performance. It also uses relative index as confidence
measures in case of contradiction in identification process by GMM
and VQ as well. Simulation results carried out on voxforge.org
speech database using MATLAB highlight the efficacy of the
proposed method compared to earlier work.
Abstract: The recent interest in alternative and renewable
energy systems results in increased installed capacity ratio of such
systems in total energy production of the world. Specifically, Wind
Energy Conversion Systems (WECS) draw significant attention
among possible alternative energy options, recently. On the contrary
of the positive points of penetrating WECS in all over the world in
terms of environment protection, energy independence of the
countries, etc., there are significant problems to be solved for the grid
connection of large scale WECS. The reactive power regulation,
voltage variation suppression, etc. can be presented as major issues to
be considered in this regard. Thus, this paper evaluates the
application of a Static VAr Compensator (SVC) unit for the reactive
power regulation and operation continuity of WECS during a fault
condition. The system is modeled employing the IEEE 13 node test
system. Thus, it is possible to evaluate the system performance with
an overall grid simulation model close to real grid systems. The
overall simulation model is developed in
MATLAB/Simulink/SimPowerSystems® environments and the
obtained results effectively match the target of the provided study.
Abstract: This paper presents a power control for a Doubly Fed
Induction Generator (DFIG) using in Wind Energy Conversion
System (WECS) connected to the grid. The proposed control strategy
employs two nonlinear controllers, Backstipping (BSC) and slidingmode
controller (SMC) scheme to directly calculate the required
rotor control voltage so as to eliminate the instantaneous errors of
active and reactive powers. In this paper the advantages of BSC and
SMC are presented, the performance and robustness of this two
controller’s strategy are compared between them. First, we present a
model of wind turbine and DFIG machine, then a synthesis of the
controllers and their application in the DFIG power control.
Simulation results on a 1.5MW grid-connected DFIG system are
provided by MATLAB/Simulink.
Abstract: This paper is focused on the reference current
calculation in the compensation mode of the active DC traction
substations. The so-called p-q theory of the instantaneous reactive
power is used as theoretical foundation. The compensation goal of
total compensation is taken into consideration for the operation under
both sinusoidal and nonsinusoidal voltage conditions, through the
two objectives of unity power factor and perfect harmonic
cancelation. Four blocks of reference current generation implement
the conceived algorithms and they are included in a specific Simulink
library, which is useful in a DSP dSPACE-based platform working
under Matlab/Simulink. The simulation results validate the
correctness of the implementation and fulfillment of the
compensation tasks.
Abstract: Greenhouses offer us suitable conditions which can
be controlled easily for the growth of the plant and they are made by
using a covering material that allows the sun light entering into the
system. Covering material can be glass, fiber glass, plastic or another
transparent element. This study investigates the solar energy usability
rates and solar energy benefitting rates of a semi-spherical (modified
arch) type greenhouse system according to different orientations and
positions which exists under climatic conditions of Bayburt. In the
concept of this study it is tried to determine the best direction and
best sizes of a semi-spherical greenhouse to get best solar benefit
from the sun. To achieve this aim a modeling study is made by using
MATLAB. However, this modeling study is run for some determined
shapes and greenhouses it can be used for different shaped
greenhouses or buildings. The basic parameters are determined as
greenhouse azimuth angle, the rate of size of long edge to short and
seasonal solar energy gaining of greenhouse. The optimum azimuth
angles of 400, 300, 250, 200, 150, 100, 50 m2 modified arch
greenhouse are 90o, 90o, 35o, 35o, 34o, 33o and 22o while their
optimum k values (ratio of length to width) are 10, 10, 10, 10, 6, 4
and 4 respectively. Positioning the buildings in order to get more
solar heat energy in winter and less in summer brings out energy and
money savings and increases the comfort.
Abstract: Implementation of advanced technologies requires
sophisticated instruments that deal with the operation, control,
restoration and protection of rapidly growing power system network
under normal and abnormal conditions. Presently, the applications of
Phasor Measurement Unit (PMU) are widely found in real time
operation, monitoring, controlling and analysis of power system
network as it eliminates the various limitations of supervisory control
and data acquisition system (SCADA) conventionally used in power
system. The use of PMU data is very rapidly increasing its
importance for online and offline analysis. Wide area measurement
system (WAMS) is developed as new technology by use of multiple
PMUs in power system. The present paper proposes a model of
Matlab based PMU using Discrete Fourier Transform (DFT)
algorithm and evaluation of its operation under different
contingencies. In this paper, PMU based two bus system having
WAMS network is presented as a case study.
Abstract: A novel method is presented for obtaining the stress
field induced by an edge dislocation in a multilayered composite. To
demonstrate the applications of the obtained solution, we consider the
problem of an interfacial crack in a periodically layered bimaterial
medium. The crack is modelled as a continuous distribution of edge
dislocations and the Distributed Dislocation Technique (DDT) is
utilized to obtain numerical results for the energy release rate (ERR).
The numerical implementation of the dislocation solution in
MATLAB is also provided.
Abstract: This paper proposes a novel heuristic algorithm that aims to determine the best size and location of distributed generators in unbalanced distribution networks. The proposed heuristic algorithm can deal with the planning cases where power loss is to be optimized without violating the system practical constraints. The distributed generation units in the proposed algorithm is modeled as voltage controlled node with the flexibility to be converted to constant power factor node in case of reactive power limit violation. The proposed algorithm is implemented in MATLAB and tested on the IEEE 37 -node feeder. The results obtained show the effectiveness of the proposed algorithm.
Abstract: Electrohydraulic servo system have been used in industry in a wide number of applications. Its dynamics are highly nonlinear and also have large extent of model uncertainties and external disturbances. In this paper, a robust back-stepping control (RBSC) scheme is proposed to overcome the problem of disturbances and system uncertainties effectively and to improve the tracking performance of EHS systems. In order to implement the proposed control scheme, the system uncertainties in EHS systems are considered as total leakage coefficient and effective oil volume. In addition, in order to obtain the virtual controls for stabilizing system, the update rule for the system uncertainty term is induced by the Lyapunov control function (LCF). To verify the performance and robustness of the proposed control system, computer simulation of the proposed control system using Matlab/Simulink Software is executed. From the computer simulation, it was found that the RBSC system produces the desired tracking performance and has robustness to the disturbances and system uncertainties of EHS systems.
Abstract: To solve these problems, we investigated the management system of heating enterprise, including strategic planning based on the balanced scorecard (BSC), quality management in accordance with the standards of the Quality Management System (QMS) ISO 9001 and analysis of the system based on expert judgment using fuzzy inference. To carry out our work we used the theory of fuzzy sets, the QMS in accordance with ISO 9001, BSC, method of construction of business processes according to the notation IDEF0, theory of modeling using Matlab software simulation tools and graphical programming LabVIEW. The results of the work are as follows: We determined possibilities of improving the management of heat-supply plant-based on QMS; after the justification and adaptation of software tool it has been used to automate a series of functions for the management and reduction of resources and for the maintenance of the system up to date; an application for the analysis of the QMS based on fuzzy inference has been created with novel organization of communication software with the application enabling the analysis of relevant data of enterprise management system.
Abstract: In dynamic system theory a mathematical model is
often used to describe their properties. In order to find a transfer
matrix of a dynamic system we need to calculate an inverse matrix.
The paper contains the fusion of the classical theory and the
procedures used in the theory of automated control for calculating the
inverse matrix. The final part of the paper models the given problem
by the Matlab.
Abstract: Among various active filters, shunt active filter is a
viable solution for reactive power and harmonics compensation. In
this paper, the SRF plan is used to generate current reference for
compensation and conventional PI controllers were used as the
controller to compensate the reactive power. The design of the closed
loop controllers is reserved simple by modeling them as first order
systems. Computationally uncomplicated and efficient SVM system
is used in the present work for better utilization of dc bus voltage.
The rating of shunt active filter has been finalized based on the
reactive power demand of the selected reactive load. The proposed
control and SVM technique are validated by simulating in MATLAB
software.