Abstract: Renewable energy sources and distributed power generation units already have an important role in electrical power generation. A mixture of different technologies penetrating the electrical grid, adds complexity in the management of distribution networks. High penetration of distributed power generation units creates node over-voltages, huge power losses, unreliable power management, reverse power flow and congestion. This paper presents an optimization algorithm capable of reducing congestion and power losses, both described as a function of weighted sum. Two factors that describe congestion are being proposed. An upgraded selective particle swarm optimization algorithm (SPSO) is used as a solution tool focusing on the technique of network reconfiguration. The upgraded SPSO algorithm is achieved with the addition of a heuristic algorithm specializing in reduction of power losses, with several scenarios being tested. Results show significant improvement in minimization of losses and congestion while achieving very small calculation times.
Abstract: The field of wireless sensor networks (WSN) engages a lot of associates in the research community as an interdisciplinary field of interest. This type of network is inexpensive, multifunctionally attributable to advances in micro-electromechanical systems and conjointly the explosion and expansion of wireless communications. A mobile ad hoc network is a wireless network without fastened infrastructure or federal management. Due to the infrastructure-less mode of operation, mobile ad-hoc networks are gaining quality. During this work, we have performed an efficient performance study of the two major routing protocols: Ad hoc On-Demand Distance Vector Routing (AODV) and Dynamic Source Routing (DSR) protocols. We have used an accurate simulation model supported NS2 for this purpose. Our simulation results showed that AODV mitigates the drawbacks of the DSDV and provides better performance as compared to DSDV.
Abstract: Intrusion detection systems (IDS) are the main components of network security. These systems analyze the network events for intrusion detection. The design of an IDS is through the training of normal traffic data or attack. The methods of machine learning are the best ways to design IDSs. In the method presented in this article, the pruning algorithm of C5.0 decision tree is being used to reduce the features of traffic data used and training IDS by the least square vector algorithm (LS-SVM). Then, the remaining features are arranged according to the predictor importance criterion. The least important features are eliminated in the order. The remaining features of this stage, which have created the highest level of accuracy in LS-SVM, are selected as the final features. The features obtained, compared to other similar articles which have examined the selected features in the least squared support vector machine model, are better in the accuracy, true positive rate, and false positive. The results are tested by the UNSW-NB15 dataset.
Abstract: In this paper, a proper approach is taken to assess a set of the most effective rotor design parameters for an external-rotor permanent magnet assisted synchronous reluctance motor (PMaSynRM) and therefore to tackle the design complexity of the rotor structure. There are different advantages for introducing permanent magnets into the rotor flux barriers, some of which are to saturate the rotor iron ribs, to increase the motor torque density and to improve the power factor. Moreover, the d-axis and q-axis inductances are of great importance to simultaneously achieve maximum developed torque and low torque ripple. Therefore, sensitivity analysis of the rotor geometry of an 8-pole external-rotor permanent magnet assisted synchronous reluctance motor is performed. Several magnetically accurate finite element analyses (FEA) are conducted to characterize the electromagnetic performance of the motor. The analyses validate torque and power factor equations for the proposed external-rotor motor. Based upon the obtained results and due to an additional term, permanent magnet torque, added to the reluctance torque, the electromagnetic torque of the PMaSynRM increases.
Abstract: Electricity prices have sophisticated features such as
high volatility, nonlinearity and high frequency that make forecasting
quite difficult. Electricity price has a volatile and non-random
character so that, it is possible to identify the patterns based on the
historical data. Intelligent decision-making requires accurate price
forecasting for market traders, retailers, and generation companies.
So far, many shallow-ANN (artificial neural networks) models have
been published in the literature and showed adequate forecasting
results. During the last years, neural networks with many hidden
layers, which are referred to as DNN (deep neural networks) have
been using in the machine learning community. The goal of this
study is to investigate electricity price forecasting performance of the
shallow-ANN and DNN models for the Turkish day-ahead electricity
market. The forecasting accuracy of the models has been evaluated
with publicly available data from the Turkish day-ahead electricity
market. Both shallow-ANN and DNN approach would give successful
result in forecasting problems. Historical load, price and weather
temperature data are used as the input variables for the models.
The data set includes power consumption measurements gathered
between January 2016 and December 2017 with one-hour resolution.
In this regard, forecasting studies have been carried out comparatively
with shallow-ANN and DNN models for Turkish electricity markets
in the related time period. The main contribution of this study
is the investigation of different shallow-ANN and DNN models
in the field of electricity price forecast. All models are compared
regarding their MAE (Mean Absolute Error) and MSE (Mean Square)
results. DNN models give better forecasting performance compare to
shallow-ANN. Best five MAE results for DNN models are 0.346,
0.372, 0.392, 0,402 and 0.409.
Abstract: Load forecasting has become crucial in recent years
and become popular in forecasting area. Many different power
forecasting models have been tried out for this purpose. Electricity
load forecasting is necessary for energy policies, healthy and reliable
grid systems. Effective power forecasting of renewable energy load
leads the decision makers to minimize the costs of electric utilities
and power plants. Forecasting tools are required that can be used
to predict how much renewable energy can be utilized. The purpose
of this study is to explore the effectiveness of LSTM-based neural
networks for estimating renewable energy loads. In this study, we
present models for predicting renewable energy loads based on
deep neural networks, especially the Long Term Memory (LSTM)
algorithms. Deep learning allows multiple layers of models to learn
representation of data. LSTM algorithms are able to store information
for long periods of time. Deep learning models have recently been
used to forecast the renewable energy sources such as predicting
wind and solar energy power. Historical load and weather information
represent the most important variables for the inputs within the
power forecasting models. The dataset contained power consumption
measurements are gathered between January 2016 and December
2017 with one-hour resolution. Models use publicly available data
from the Turkish Renewable Energy Resources Support Mechanism.
Forecasting studies have been carried out with these data via deep
neural networks approach including LSTM technique for Turkish
electricity markets. 432 different models are created by changing
layers cell count and dropout. The adaptive moment estimation
(ADAM) algorithm is used for training as a gradient-based optimizer
instead of SGD (stochastic gradient). ADAM performed better than
SGD in terms of faster convergence and lower error rates. Models
performance is compared according to MAE (Mean Absolute Error)
and MSE (Mean Squared Error). Best five MAE results out of
432 tested models are 0.66, 0.74, 0.85 and 1.09. The forecasting
performance of the proposed LSTM models gives successful results
compared to literature searches.
Abstract: In this paper, a planar monopole antenna for multi band applications is proposed. The antenna structure operates at three operating frequencies at 3.7, 6.2, and 13.5 GHz which cover different communication frequency ranges. The antenna consists of a quasi-modified rectangular radiating patch with a partial ground plane and two parasitic elements (open-loop-ring resonators) to serve as coupling-bridges. A stepped cut at lower corners of the radiating patch and the partial ground plane are used, to achieve the multiband features. The proposed antenna is manufactured on the FR4 substrate and is simulated and optimized using High Frequency Simulation System (HFSS). The antenna topology possesses an area of 30.5 x 30 x 1.6 mm3. The measured results demonstrate that the candidate antenna has impedance bandwidths for 10 dB return loss and operates from 3.80 – 3.90 GHz, 4.10 – 5.20 GHz, 11.2 – 11.5 GHz and from 12.5 – 14.0 GHz, which meet the requirements of the wireless local area network (WLAN), worldwide interoperability for microwave access (WiMAX), C- (Uplink) and Ku- (Uplink) band applications. Acceptable agreement is obtained between measurement and simulation results. Experimental results show that the antenna is successfully simulated and measured, and the tri-band antenna can be achieved by adjusting the lengths of the three elements and it gives good gains across all the operation bands.
Abstract: Green microgrids using mostly renewable energy (RE) for generation, are complex systems with inherent nonlinear dynamics. Among a variety of different optimization tools there are only a few ones that adequately consider this complexity. This paper evaluates applicability of two somewhat similar optimization tools tailored for standalone RE microgrids and also assesses a machine learning tool for performance prediction that can enhance the reliability of any chosen optimization tool. It shows that one of these microgrid optimization tools has certain advantages over another and presents a detailed routine of preparing input data to simulate RE microgrid behavior. The paper also shows how neural-network-based predictive modeling can be used to validate and forecast solar power generation based on weather time series data, which improves the overall quality of standalone RE microgrid analysis.
Abstract: The method of moments combined with the method
of symmetrical components is used for the analysis of interstitial
hyperthermia applicators. The basis and testing functions are both
piecewise sinusoids, qualifying our technique as a Galerkin one. The
dielectric coatings are modeled by equivalent volume polarization
currents, which are simply related to the conduction current
distribution, avoiding in that way the introduction of additional
unknowns or numerical integrations. The results of our method
for a four dipole circular array, are in agreement with those
already published in literature for a same hyperthermia configuration.
Apart from being accurate, our approach is more general, more
computationally efficient and takes into account the coupling between
the antennas.
Abstract: Applications of reversible logic gates in the design of complex integrated circuits provide power optimization. This technique finds a great use in low power CMOS design, optical computing, quantum computing and nanotechnology. This paper proposes a reversible signed division circuit that can divide an n-bit signed dividend with an n-bit signed divisor using non-restoration division logic. The proposed design adequately addresses the ‘delay’ there by improving the efficiency of the circuit. An attempt is made to design a reversible signed division circuit. This paper provides a threshold to build more complex arithmetic systems using reversible logic, thus increasing the performance of computing systems.
Abstract: Energy consumption schedule (ECS) technique shifts usage of loads from on peak hours and redistributes them throughout the day according to residents’ operating time preferences. This technique is used as form of indirect control from utility to improve the load curve and hence its load factor and reduce customer’s total electric bill as well. Similarly, load shifting technique achieves ECS purposes but as direct control form applied from utility. In this paper, ECS is simulated twice as optimal constrained mathematical formula, solved by using CVX program in MATLAB® R2013b. First, it is utilized for single residential building with ten apartments to determine max allowable energy consumption per hour for each residential apartment. Then, it is used for single apartment with number of shiftable domestic devices, where operating schedule is deduced using previous simulation output results as constraints. The paper ends by giving differences between ECS technique and load shifting technique via literature and simulation. Based on results assessment, it will be shown whether using ECS or load shifting is more beneficial to both customer and utility.
Abstract: This paper presents the design and performance evaluation of multiband metamaterial based antenna operating in the 3.6 GHz (4G), 14.33 GHz, and 28.86 GHz (5G) frequency bands, for future mobile and handheld devices. The radiating element of the proposed design is made up of a conductive material supported by a 1.524 mm thicker Rogers-4003 substrate, having a relative dielectric constant and loss tangent of 3.55 and 0.0027, respectively. The substrate is backed by truncated ground plane. The future mobile communication system is based on higher frequencies, which are highly affected by the atmospheric conditions. Therefore, to overcome the path loss problem, essential enhancements and improvements must be made in the overall performance of the antenna. The traditional ground plane does not provide the in-phase reflection and surface wave suppression due to which side and back lobes are produced. This will affect the antenna performance in terms of gain and efficiency. To enhance the overall performance of the antenna, a metamaterial acting as a high impedance surface (HIS) is used as a reflector in the proposed design. The simulated gain of the metamaterial based antenna is enhanced from {2.76-6.47, 4.83-6.71 and 7.52-7.73} dB at 3.6, 14.33 and 28.89 GHz, respectively relative to the gain of the antenna backed by a traditional ground plane. The proposed antenna radiated efficiently with a radiated efficiency (>85 %) in all the three frequency bands with and without metamaterial surface. The total volume of the antenna is (L x W x h=45 x 40 x 1.524) mm3. The antenna can be potentially used for wireless handheld devices and mobile terminal. All the simulations have been performed using the Computer Simulation Technology (CST) software.
Abstract: The main goal of this paper is to develop a switching amplifier with optimized power efficiency for analog signals with a very high crest factor such as audio or DSL signals. Theoretical calculations show that a switching amplifier architecture based on multi-level pulse width modulation outperforms all other types of linear or switching amplifiers in that respect. Simulations on a 2 W multi-level switching audio amplifier, designed in a 50 V 0.35 mm IC technology, confirm its superior performance in terms of power efficiency. A real silicon implementation of this audio amplifier design is currently underway to provide experimental validation.
Abstract: Flexible AC transmission system controllers play an important role in controlling the line power flow and in improving voltage profiles of the power system network. They can be used to increase the reliability and efficiency of transmission and distribution system. The modeling of these FACTS controllers in power flow calculations have become a challenging research problem. This paper presents a simple and systematic approach for a steady state power flow calculations of power system with STATCOM (Static Synchronous Compensator). It shows how systematically STATCOM can be implemented in conventional power flow calculations. The main contribution of this paper is to investigate this approach for two special conditions i.e. consideration of load increase pattern incorporating load change (active, reactive and both active and reactive) at all load buses simultaneously and the line contingencies under such load change. Such investigation proves to be relevant for determination of strategy for the optimal placement of STATCOM to enhance the voltage stability. The performance has been evaluated on many standard IEEE test systems. The results for standard IEEE-30 bus test system are presented here.
Abstract: We develop a periodically-poled LiNbO3 (PPLN)
device for highly-efficient third-harmonic generation (THG), where
the THG efficiency is enhanced with a cavity. THG can usually be
produced via χ(3)-nonlinear materials by optical pumping with very
high pump-power. Instead, we here propose THG by moderate-power
pumping through a specially-designed PPLN device containing
only χ(2)-nonlinearity, where sum-frequency generation in the χ(2)
process is employed for the mixing of a pump beam and a
second-harmonic-generation (SHG) beam produced from the pump
beam. The cavity is designed to increase the SHG power with dichroic
mirrors attached to both ends of the device that perfectly reflect
the SHG beam back to the device and yet let the pump and THG
beams pass through the mirrors. This brings about a THG-power
enhancement because of THG power proportional to the enhanced
SHG power. We examine the THG-efficiency dependence on the
mirror reflectance and show that very high THG-efficiency is obtained
at moderate pump-power when compared with that of a cavity-free
PPLN device.
Abstract: The multi-level inverters present an important novelty in the field of energy control with high voltage and power. The major advantage of all multi-level inverters is the improvement and spectral quality of its generated output signals. In recent years, various pulse width modulation techniques have been developed. From these technics we have: Sinusoidal Pulse Width Modulation (SPWM) and Space Vector Pulse Width Modulation (SVPWM). This work presents a detailed analysis of the comparative advantage of space vector pulse width modulation (SVPWM) and the standard SPWM technique for Three Level Diode Clamped Inverter fed Induction Motor. The comparison is based on the evaluation of harmonic distortion THD.
Abstract: Wireless sensor network finds role in environmental monitoring, industrial applications, surveillance applications, health monitoring and other supervisory applications. Sensing devices form the basic operational unit of the network that is self-battery powered with limited life time. Sensor node spends its limited energy for transmission, reception, routing and sensing information. Frequent energy utilization for the above mentioned process leads to network lifetime degradation. To enhance energy efficiency and network lifetime, we propose a modified energy optimization and node recovery post failure method, Energy-Link Failure Recovery Routing (E-LFRR) algorithm. In our E-LFRR algorithm, two phases namely, Monitored Transmission phase and Replaced Transmission phase are devised to combat worst case link failure conditions. In Monitored Transmission phase, the Actuator Node monitors and identifies suitable nodes for shortest path transmission. The Replaced Transmission phase dispatches the energy draining node at early stage from the active link and replaces it with the new node that has sufficient energy. Simulation results illustrate that this combined methodology reduces overhead, energy consumption, delay and maintains considerable amount of alive nodes thereby enhancing the network performance.
Abstract: In this article, Optimal Control for Coordinated Control (COC) of Series Vectorial Compensator (SVeC) and Power System Stabilizer (PSS) in order to damp Low Frequency Oscillations (LFO) is proposed. SVeC is a series Flexible Alternating Current Transmission System (FACTS) device. The Optimal Control strategy based on state feedback control for coordination of PSS and SVeC controllers under different loading conditions has not been developed. So, the Optimal State Feedback Controller (OSFC) for incorporating of PSS and SVeC controllers in COC manner has been developed in this paper. The performance of the proposed controller is checked through eigenvalue analysis and nonlinear time domain simulation results. The proposed Optimal Controller design for the COC of SVeC and PSS results will be analyzed without controller. The comparative results show that Optimal Controller for COC of SVeC and PSSs improve greatly the system damping LFO than without controller.
Abstract: This paper presents the closed form nonlinear
expressions of bipolar junction transistor (BJT) differential amplifier
(DA) using perturbation method. Circuit equations have been derived
using Kirchhoff’s voltage law (KVL) and Kirchhoff’s current law
(KCL). The perturbation method has been applied to state variables
for obtaining the linear and nonlinear terms. The implementation
of the proposed method is simple. The closed form nonlinear
expressions provide better insights of physical systems. The derived
equations can be used for signal processing applications.
Abstract: This paper proposes empirical mode decomposition
(EMD) together with wavelet transform (WT) based analytic signal
for power quality (PQ) events assessment. EMD decomposes the
complex signals into several intrinsic mode functions (IMF). As
the PQ events are non stationary, instantaneous parameters have
been calculated from these IMFs using analytic signal obtained
form WT. We obtained three parameters from IMFs and then used
KNN classifier for classification of PQ disturbance. We compared
the classification of proposed method for PQ events by obtaining
the features using Hilbert transform (HT) method. The classification
efficiency using WT based analytic method is 97.5% and using HT
based analytic signal is 95.5%.