Abstract: The one of most important objects in implementation
of damage analysis observations is manner of dam break wave
propagation. In this paper velocity and wave height due dam break in
with and without tailwater states for appointment hazardous lands
and flood radius are investigate. In order to modeling above
phenomenon finite volume method of Roe type for solving shallow
water equations is used. Results indicated that in the dry bed state
risk radius due to dam break is too high. While in the wet bed risk
radius has a less wide. Therefore in the first state constructions and
storage facilities are encountered with destruction risk. Further
velocity due to dam break in the second state is more comparing to
the first state. Hence erosion and scour the river bed in the dry bed is
too more compare to the wet bed.
Abstract: Cylindrical concrete reservoirs are appropriate choice
for storing liquids as water, oil and etc. By using of the pre-cast
concrete reservoirs instead of the in-situ constructed reservoirs, the
speed and precision of the construction would considerably increase.
In this construction method, wall and roof panels would make in
factory with high quality materials and precise controlling. Then,
pre-cast wall and roof panels would carry out to the construction site
for assembling. This method has a few faults such as: the existing
weeks in connection of wall panels together and wall panels to
foundation. Therefore, these have to be resisted under applied loads
such as seismic load. One of the innovative methods which was
successfully applied for seismic retrofitting of numerous pre-cast
cylindrical water reservoirs in New Zealand, using of the high tensile
cables around the reservoirs and post-tensioning them. In this paper,
analytical modeling of wall and roof panels and post-tensioned
cables are carried out with finite element method and the effect of
height to diameter ratio, post-tensioning force value, liquid level in
reservoir, installing position of tendons on seismic response of
reservoirs are investigated.
Abstract: Ten simply supported grossly underreinforced
tapered concrete beams of full size were tested upto complete
collapse under flexural effect .Out of 10 beams, 5 beams were
nonfibrous and the remaining beams contained fibres. The beams
had a variation in the tapered angle as 2°, 4°, 6°, 8° and 10°. The
concrete mix, conventional steel and the type of fibre used were
held constant. Flat corrugated steel fibres were utilized as
secondary reinforcement. The strength and stability parameters
were measured. It is established that the fibrous tapered beams can
be used economically in earthquake prone areas.
Abstract: The increasing demand for sufficient and clean
energy forces industrial and service companies to align their strategies towards efficient consumption. This trend refers also to the
residential building sector. There, large amounts of energy consumption are caused by house and facility heating. Many of the
operated hot water heating systems lack hydraulic balanced working
conditions for heat distribution and –transmission and lead to
inefficient heating. Through hydraulic balancing of heating systems,
significant energy savings for primary and secondary energy can be
achieved. This paper addresses the use of KNX-technology (Smart
Buildings) in residential buildings to ensure a dynamic adaption of
hydraulic system's performance, in order to increase the heating
system's efficiency. In this paper, the procedure of heating system
segmentation into hydraulically independent units (meshes) is
presented. Within these meshes, the heating valve are addressed and
controlled by a central facility server. Feasibility criteria towards
such drivers will be named. The dynamic hydraulic balance is
achieved by positioning these valves according to heating loads, that
are generated from the temperature settings in the corresponding
rooms. The energetic advantages of single room heating control
procedures, based on the application FacilityManager, is presented.
Abstract: The paper investigates the potential of support vector
machines and Gaussian process based regression approaches to
model the oxygen–transfer capacity from experimental data of
multiple plunging jets oxygenation systems. The results suggest the
utility of both the modeling techniques in the prediction of the
overall volumetric oxygen transfer coefficient (KLa) from operational
parameters of multiple plunging jets oxygenation system. The
correlation coefficient root mean square error and coefficient of
determination values of 0.971, 0.002 and 0.945 respectively were
achieved by support vector machine in comparison to values of
0.960, 0.002 and 0.920 respectively achieved by Gaussian process
regression. Further, the performances of both these regression
approaches in predicting the overall volumetric oxygen transfer
coefficient was compared with the empirical relationship for multiple
plunging jets. A comparison of results suggests that support vector
machines approach works well in comparison to both empirical
relationship and Gaussian process approaches, and could successfully
be employed in modeling oxygen-transfer.
Abstract: In this paper a polymer electrolyte membrane (PEM)
fuel cell power system including burner, steam reformer, heat
exchanger and water heater has been considered to meet the
electrical, heating, cooling and domestic hot water loads of
residential building which in Tehran. The system uses natural gas as
fuel and works in CHP mode. Design and operating conditions of a
PEM fuel cell system is considered in this study. The energy
requirements of residential building and the number of fuel cell
stacks to meet them have been estimated. The method involved
exergy analysis and entropy generation thorough the months of the
year. Results show that all the energy needs of the building can be
met with 12 fuel cell stacks at a nominal capacity of 8.5 kW. Exergy
analysis of the CHP system shows that the increase in the ambient air
temperature from 1oC to 40oC, will have an increase of entropy
generation by 5.73%.Maximum entropy generates for 15 hour in 15th
of June and 15th of July is estimated to amount at 12624 (kW/K).
Entropy generation of this system through a year is estimated to
amount to 1004.54 GJ/k.year.
Abstract: Over half of the total electricity consumption is used in buildings. Air-conditioning and electric lighting are the two main resources of electricity consumption in high rise buildings. One way to reduce electricity consumption would be to limit heat gain into buildings, therefore reduce the demand for air-conditioning during hot summer months especially in hot regions. On the other hand natural daylight can be used to reduce the use of electricity for artificial lighting. In this paper effective factors on minimizing heat gain and achieving required day light were reviewed .As daylight always accompanied by solar heat gain. Also interactions between heat gain and daylight were discussed through previous studies and equations which are related to heat gain and day lighting especially in high rise buildings. As a result importance of building-s form and its component on energy consumption in buildings were clarified.
Abstract: Firstly, this study briefly presents the current situation that there exists a vast gap between current Chinese and Japanese seismic design specification for bridge pile foundation in liquefiable and liquefaction-induced lateral spreading ground; The Chinese and Japanese seismic design method and technical detail for bridge pile foundation in liquefying and lateral spreading ground are described and compared systematically and comprehensively, the methods of determining coefficient of subgrade reaction and its reduction factor as well as the computing mode of the applied force on pile foundation due to liquefaction-induced lateral spreading soil in Japanese design specification are especially introduced. Subsequently, the comparison indicates that the content of Chinese seismic design specification for bridge pile foundation in liquefiable and liquefaction-induced lateral spreading ground, just presenting some qualitative items, is too general and lacks systematicness and maneuverability. Finally, some defects of seismic design specification in China are summarized, so the improvement and revision of specification in the field turns out to be imperative for China, some key problems of current Chinese specifications are generalized and the corresponding improvement suggestions are proposed.
Abstract: In the real application of active control systems to
mitigate the response of structures subjected to sever external
excitations such as earthquake and wind induced vibrations, since the
capacity of actuators is limited then the actuators saturate. Hence, in
designing controllers for linear and nonlinear structures under sever
earthquakes, the actuator saturation should be considered as a
constraint. In this paper optimal design of active controllers for
nonlinear structures by considering the actuator saturation has been
studied. To this end a method has been proposed based on defining
an optimization problem which considers the minimizing of the
maximum displacement of the structure as objective when a limited
capacity for actuator has been used as a constraint in optimization
problem. To evaluate the effectiveness of the proposed method, a
single degree of freedom (SDF) structure with a bilinear hysteretic
behavior has been simulated under a white noise ground acceleration
of different amplitudes. Active tendon control mechanism, comprised
of pre-stressed tendons and an actuator, and extended nonlinear
Newmark method based instantaneous optimal control algorithm
have been used as active control mechanism and algorithm. To
enhance the efficiency of the controllers, the weights corresponding
to displacement, velocity, acceleration and control force in the
performance index have been found by using the Distributed Genetic
Algorithm (DGA). According to the results it has been concluded
that the proposed method has been effective in considering the
actuator saturation in designing optimal controllers for nonlinear
frames. Also it has been shown that the actuator capacity and the
average value of required control force are two important factors in
designing nonlinear controllers for considering the actuator
saturation.
Abstract: In spite of the advent of new materials, clay bricks
remain, arguably, the most popular construction materials today.
Nevertheless the low cost and versatility of clay bricks cannot always
be associated with high environmental and sustainable values,
especially in terms of raw material sources and manufacturing
processes. At the same time, the worldwide agricultural footprint is
fast growing, with vast agricultural land cultivation and active
expansion of the agro-based industry. The resulting large quantities of
agricultural wastes, unfortunately, are not always well managed or
utilised. These wastes can be recycled, such as by retrieving fibres
from disposed leaves and fruit bunches, and then incorporated in
brick-making. This way the clay bricks are made a 'greener' building
material and the discarded natural wastes can be reutilised, avoiding
otherwise wasteful landfill and harmful open incineration. This study
examined the physical and mechanical properties of clay bricks made
by adding two natural fibres to a clay-water mixture, with baked and
non-baked conditions. The fibres were sourced from pineapple leaves
(PF) and oil palm fruit bunch (OF), and added within the range of
0.25-0.75 %. Cement was added as a binder to the mixture at 5-15 %.
Although the two fibres had different effects on the bricks produced,
cement appeared to dominate the compressive strength. The
non-baked bricks disintegrated when submerged in water, while the
baked ones displayed cement-dependent characteristics in
water-absorption and density changes. Interestingly, further increase
in fibre content did not cause significant density decrease in both the
baked and non-baked bricks.
Abstract: The main objectives of this study are to inspect and
identify any damage of jaimusi highway prestressed concrete bridge
after repair and strengthening of damaged structural members and to
evaluate the performance of the bridge structural members by
adopting static load test. Inspection program after repair and
strengthening includes identifying and evaluating the structural
members of bridge such as T-shape cantilever structure, hanging
beams, corbels, external tendons, anchor beams, sticking steel plate,
and piers. The results of inspection show that the overall state of the
bridge structural member after repair and strengthening is good. The
results of rebound test of concrete strength show that the average
strength of concrete is 46.31Mpa. Whereas, the average value of
concrete strength of anchor beam is 49.82Mpa. According to the
results of static load test, the experimental values are less than
theoretical values of internal forces, deflection, and strain, indicating
that the stiffness of the experimental structure, overall deformation
and integrity satisfy the designed standard and the working
performance is good, and the undertaking capacity has a certain
surplus. There is not visible change in the length and width of cracks
and there are not new cracks under experimental load.