Abstract: This paper aims to study performance of a thermosiphon solar water heating system with the help of the proposed analytical model. This proposed model predicts the temperature and mass flow rate in a thermosiphon solar water heating system depending on radiation intensity and ambient temperature. The performance of the thermosiphon solar water heating system is evaluated in the Indian context. For this, eight cities in India are selected considering radiation intensity and geographical positions. Predicted performance at various cities reveals the potential for thermosiphon solar water in India.
Abstract: The purpose of this paper is to present an active solar energy system to supply heating demands of the teaching staff dormitory of the Islamic Azad University of Ramhormoz. The design takes into account the solar radiations and climate data of Ramhormoz town and is based on the daily warm water consumption for health demands of 450 residents of the dormitory, which is equal to 27000 lit of 50-C° water, and building heating requirements with an area of 3500 m² well-protected by heatproof materials. First, heating demands of the building were calculated, then a hybrid system made up of solar and fossil energies was developed and finally, the design was economically evaluated. Since there is only roof space for using 110 flat solar water heaters, the calculations were made to hybridize solar water heating system with heat pumping system in which solar energy contributes 67% of the heat generated. According to calculations, the net present value “N.P.V.” of revenue stream exceeds “N.P.V.” of cash paid off in this project over three years, which makes economically quite promising. The return of investment and payback period of the project is 4 years. Also, the internal rate of return (IRR) of the project was 25%, which exceeds bank rate of interest in Iran and emphasizes the desirability of the project.
Abstract: Renewable energy resources, which can supplement space and water heating for residential buildings, can have a noticeable impact on natural gas consumption and air pollution. This study considers a technical analysis of a combined solar water heating system with evacuated tube solar collectors for different solar coverage, ranging from 20% to 100% of the total roof area of a typical residential building located in Edmonton, Alberta, Canada. The alternative heating systems were conventional (non-condensing) and condensing tankless water heaters and condensing boilers that were coupled to solar water heating systems. The performance of the alternative heating systems was compared to a traditional heating system, consisting of a conventional boiler, applied to houses of various gross floor areas. A comparison among the annual natural gas consumption, carbon dioxide (CO2) mitigation, and emissions for the various house sizes indicated that the combined solar heating system can reduce the natural gas consumption and CO2 emissions, and increase CO2 mitigation for all the systems that were studied. The results suggest that solar water heating systems are potentially beneficial for residential heating system applications in terms of energy savings and CO2 mitigation.
Abstract: Solar water heating is a thermodynamic process of
heating water using sunlight with the help of solar water heater. Thus,
solar water heater is a device used to harness solar energy. In this
paper, a modified solar water heating system (MSWHS) has been
proposed over flat plate collector (FPC) and Evacuated tube collector
(ETC). The modifications include selection of materials other than
glass, and glass wool which are conventionally used for fabricating
FPC and ETC. Some modifications in design have also been
proposed. Its collector is made of double layer of semi-cylindrical
acrylic tubes and fibre reinforced plastic (FRP) insulation base. Water
tank is made of double layer of acrylic sheet except base and north
wall. FRP is used in base and north wall of the water tank. A concept
of equivalent thickness has been utilised for calculating the
dimensions of collector plate, acrylic tube and tank. A thermal model for the proposed design of MSWHS is developed
and simulation is carried out on MATLAB for the capacity of 200L
MSWHS having collector area of 1.6 m2, length of acrylic tubes of
2m at an inclination angle 25° which is taken nearly equal to the
latitude of the given location. Latitude of Allahabad is 24.45° N. The
results show that the maximum temperature of water in tank and tube
has been found to be 71.2°C and 73.3°C at 17:00hr and 16:00hr
respectively in March for the climatic data of Allahabad. Theoretical performance analysis has been carried out by varying
number of tubes of collector, the tank capacity and climatic data for
given months of winter and summer.
Abstract: The thermal performance of a solar water heating with
1.00 m2 flat plate collectors in Cascavel - PR, is which presented in
this article, paper presents the solution to leverage the marketing of
solar heating systems through detailed constituent materials of the
solar collector studies, these abundant materials in construction, such
as expanded polyethylene, PVC, aluminum and glass tubes, mixing
them with new materials to minimize loss of efficiency while
decreasing its cost. The system was tested during months and the
collector obtained maximum recorded temperature of outlet fluid of
55°C, while the maximum temperature of the water at the bottom of
the hot water tank was 35°C. The average daily energy collected was
19.6 MJ/d; the energy supplied by the solar plate was 16.2 MJ/d; the
loss in the feed pipe was 3.2 MJ/d; the solar fraction was 32.2%, the
efficiency of the collector was 45.6% and the efficiency of the system
was 37.8%.
Abstract: A single-phase closed thermosyphon has been
fabricated and experimented to utilize solar energy for water heating.
The working fluid of the closed thermosyphon is heated at the flatplate
collector and the hot water goes to the water tank due to density
gradient caused by temperature differences. This experimental work
was done using insulated water tank and insulated connecting pipe
between the tank and the flat-plate collector. From the collected data,
performance parameters such as instantaneous collector efficiency
and heat removal factor are calculated. In this study, the effects of
glazing were also observed. The water temperature rise and the
maximum instantaneous efficiency obtained from this experiment
with glazing using insulated water tank and insulated connecting pipe
are 17°C in a period of 5 hours and 60% respectively. Whereas the
water temperature rise and the maximum instantaneous efficiency
obtained from this experiment with glazing using non-insulated water
tank and non-insulated connecting pipe are 14°C in a period of 5
hours and 39% respectively.
Abstract: Solar water heating (SWH) systems are gaining popularity in ASEAN in the midst of increasing number of affluent population in society and environmental concerns from seemingly unchanged reliance on fossil-based fuels. The penetration of these systems and technologies into ASEAN markets is a welcome development; however there is a need for the method of assessment of their thermal performances. This paper discusses the reasons for this need and a suitable method for thermal performance evaluation of SWH systems in ASEAN. The paper also calls on research to be focused on the establishment of reliable data to be entered into the performance rating software. The establishment of accredited solar systems testing facilities can help boost the competitiveness of ASEAN solar industry.