Abstract: Water is essential for life and fresh water is a finite
resource that is becoming scarce day by day even though it is
recycled by hydrological cycle. The fresh water reserves are being
polluted due to expanding irrigation, industries, urban population and
its development. Contaminated water leads to several health
problems. With the increasing demand of fresh water, solar
distillation is an alternate solution which uses solar energy to
evaporate water and then to condense it, thereby collecting distilled
water within or outside the same system to use it as potable water.
The structure that houses the process is known as a 'solar still'. In this
paper, ‘Modified double slope solar still (MDSSS)’ & 'Modified
double slope basin type multiwick solar still (MDSBMSS)' have been
designed to convert saline, brackish water into drinking water. In this
work two different modified solar stills are fabricated to study the
performance of these solar stills. For modification of solar stills,
Fibre Reinforced Plastic (FRP) and Acrylic sheets are used. The
experiments in MDSBMSS and MDSSS was carried on 10
September 2015 & 5 November 2015 respectively. Performances of
the stills were investigated. The amount of distillate has been found
3624 Ml/day in MDSBMSS on 10 September 2015 and 2400 Ml/day
in MDSSS on 5 November 2015.
Abstract: Solar water heating is a thermodynamic process of
heating water using sunlight with the help of solar water heater. Thus,
solar water heater is a device used to harness solar energy. In this
paper, a modified solar water heating system (MSWHS) has been
proposed over flat plate collector (FPC) and Evacuated tube collector
(ETC). The modifications include selection of materials other than
glass, and glass wool which are conventionally used for fabricating
FPC and ETC. Some modifications in design have also been
proposed. Its collector is made of double layer of semi-cylindrical
acrylic tubes and fibre reinforced plastic (FRP) insulation base. Water
tank is made of double layer of acrylic sheet except base and north
wall. FRP is used in base and north wall of the water tank. A concept
of equivalent thickness has been utilised for calculating the
dimensions of collector plate, acrylic tube and tank. A thermal model for the proposed design of MSWHS is developed
and simulation is carried out on MATLAB for the capacity of 200L
MSWHS having collector area of 1.6 m2, length of acrylic tubes of
2m at an inclination angle 25° which is taken nearly equal to the
latitude of the given location. Latitude of Allahabad is 24.45° N. The
results show that the maximum temperature of water in tank and tube
has been found to be 71.2°C and 73.3°C at 17:00hr and 16:00hr
respectively in March for the climatic data of Allahabad. Theoretical performance analysis has been carried out by varying
number of tubes of collector, the tank capacity and climatic data for
given months of winter and summer.